PCE Instruments PCE-VE 330N, PCE-VE 340N, PCE-VE 360N, PCE-VE 320N, PCE-VE 380N Users guide

...
Page 1
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com
PCE Instruments UK Ltd.
Unit 11
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.co.uk
www.pce-instruments.com/english
www.pce-instruments.com
Manual
Video endoscope PCE-VE 3xxN Series
Version 2.3
Date of creation: 21.04.2016
Date of last change: 09.08.2021
Page 2
Manual
2
Contents
1 Safety notes......................................................................................................................................... 3
2 Specifications...................................................................................................................................... 4
2.1 Technical specifications .............................................................................................................. 4
2.2 Delivery contents ........................................................................................................................ 6
3 System description ............................................................................................................................. 6
4 Getting started .................................................................................................................................... 7
5 Operation ............................................................................................................................................. 7
5.1 Take a picture ............................................................................................................................. 7
5.2 Record a video ........................................................................................................................... 7
5.3 View data .................................................................................................................................... 7
5.4 Settings ....................................................................................................................................... 8
6 HR camera cable (PCE-VE 3xxHR or optional) ................................................................................ 9
7 Articulating camera cable (PCE-VE 350N / HR / N3 / HR3 only or optional) ............................... 15
8 HR camera cable with 360° articulating camera head (PCE-VE 370HR3 or optional) ............... 18
9 PCE-VE 380N ..................................................................................................................................... 22
9.1 Safety notes .............................................................................................................................. 22
9.2 Technical specifications ............................................................................................................ 22
9.3 System description ................................................................................................................... 23
9.4 Getting started .......................................................................................................................... 24
9.5 Operation .................................................................................................................................. 26
9.6 Locator PCE-VE-LOC (optional or PCE-VE 380N-LOC) ......................................................... 29
10 PCE-VE 390N ..................................................................................................................................... 34
10.1 Safety instructions .................................................................................................................... 34
10.2 Technical specifications ............................................................................................................ 35
10.3 System description ................................................................................................................... 36
10.4 Getting started .......................................................................................................................... 36
11 Disposal ............................................................................................................................................. 38
12 Contact ............................................................................................................................................... 38
12.1 PCE Instruments UK ................................................................................................................ 38
12.2 PCE Americas .......................................................................................................................... 38
Page 3
Manual
3
Thank you for purchasing a video endoscope from PCE Instruments.
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no warranty of damages or injuries caused by non-observance of the manual.
This device may only be used in the way specified in this manual. If used otherwise, this may cause dangerous situations.
Do not expose the device to extreme temperatures, direct sunlight, extreme air humidity or moisture.
The case should only be opened by qualified personnel of PCE Instruments.
Do not touch the instrument with wet hands.
Do not expose the device to shocks or strong vibrations.
You should not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner without
solvents or abrasives.
The device must only be used with original PCE accessories or equivalent.
Before each use, please inspect the case for damage. In case of any visible damage, please do
not use the device.
The device must not be used be used when the environmental conditions (temperature, air humidity,…) are outside the limit values stated in the specifications.
Do not expose the instrument to explosive atmospheres.
Do not use the endoscope near uninsulated current-carrying conductors.
The instrument should never be placed with the user interface facing an object (e. g. keyboard
side on a table).
This product has been produced for industrial use only. Do not use it for medical or any other biological purposes.
This user's handbook is published by PCE Instruments without any guarantee. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments.
Page 4
Manual
4
2 Specifications
2.1 Technical specifications General specifications
Sensor
CMOS
Resolution videos / pictures
640 x 480
Frame rate
30 fps
Lighting
Automatic
White balance
Fixed
Field of view
67 ° PCE-VE 380N / PCE-VE 390N: 150.8 °
Depth of field
1.5 … 10 cm PCE-VE 380N / PCE-VE 390N:10 … mm
Bending radius
90 mm PCE-VE 380N / PCE-VE 390N: Ø 30 cm
Display
3.5 “ (88.9 mm) TFT display
Interface
Mini-USB 1.1 AV out
Memory
8 GB SD card
Compression format
MPEG4
Video format
ASF
Video output system
NTSC / PAL
Picture format
JPEG
Power supply
Rechargeable 3.7 V Li-ion battery
Environmental conditions
0 … +60 °C PCE-VE 350N: -10 … +50 °C PCE-VE 380N: -10 … +60 °C
Weight
450 g (incl. carrying case)
Page 5
Manual
5
Camera cable specifications
Model
Cable
length
Cable type
Cable
Ø
Boost
function*
Lighting
Articulation
camera head
PCE-VE 320N
1000 mm
Semi-
flexible
5.5 mm
No
4 LEDs
Front view only
PCE-VE 320HR
1000 mm
Semi-
flexible
5.5 mm
Yes
4 LEDs on the front 2 LEDs on the side
Front view only PCE-VE 330N
2000 mm
Semi-
flexible
5.5 mm
No
4 LEDs
Front view only
PCE-VE 333HR
3000 mm
Semi-
flexible
5.5 mm
Yes
4 LEDs on the front 2 LEDs on the side
Front view only PCE-VE 340N
10000
mm
Flexible
5.5 mm
No
3 LEDs
Front view only
PCE-VE 350N
1000 mm
Flexible
6.0 mm
No
4 LEDs
2-way articulation
PCE-VE 350N3**
3000 mm
Flexible
6.0 mm
No
4 LEDs
2-way articulation
PCE-VE 350HR
1000 mm
Flexible
6.0 mm
Yes
4 LEDs on the front 2 LEDs on the side
2-way articulation
PCE-VE 350HR3
3000 mm
Flexible
6.0 mm
Yes
4 LEDs on the front 2 LEDs on the side
2-way articulation
PCE-VE 355N
1500 mm
Flexible
4.5 mm
No
5 LEDs
2-way articulation
PCE-VE 355N3
3000 mm
Flexible
4.5 mm
No
5 LEDs
2-way articulation
PCE-VE 360N
1000 mm
Semi-
flexible
3.9 mm
No
3 LEDs
Front view only
PCE-VE 370HR
1000 mm
Semi-
flexible
6.0 mm
Yes
3 LEDs
4-way articulation
PCE-VE 370HR3
3000 mm
Flexible
6.0 mm
Yes
3 LEDs
4-way articulation
PCE-VE 380N
30000
mm
Semi-
flexible
28 mm
No
8 LEDs
Front view only
PCE-VE 390N
10000
mm
Semi-
flexible
28 mm
No
8 LEDs
Front view only
*The boost function improves the quality of pictures and videos in dark environments. **This model is no longer available.
Page 6
Manual
6
2.2 Delivery contents
1 x endoscope PCE-VE 3xxN or HR (one of the models) 1 x 8 GB SD card 1 x USB cable 1 x mains adaptor 1 x carrying case (PCE-VE 390 N: + carrying belts) 1 x instruction manual
3 System description
Function keys
A power button B photo button C video button
D up button E down button F OK button OK G escape button ESC
H illumination switch I SD card slot J AV out K USB interface
L mains connection M Display N camera cable/tube O reset button
Page 7
Manual
7
4 Getting started
Connect the camera cable to the display unit and screw it tightly. Make sure that the indication on the connector is on the upper side (see picture above).
After that, press and hold the power button for approx. 5 seconds to turn on the device. Now the display shows the following:
SD card capacity
Battery status
To turn off the device, press and hold the power button for 3 to 5 seconds.
5 Operation
5.1 Take a picture
To take a picture of the current image on the display, simply press the photo button . The picture is stored on the SD card. After saving the picture, the device returns to the standard viewing mode. You can press the escape button ESC to zoom in (2x digital zoom). If you press and hold the escape button ESC for a few seconds, the image on the screens gets mirrored.
5.2 Record a video
To start recording a video, press the video button . An indication appears on the display showing that video recording is in progress. Press the video button again to stop the recording. The video is stored
on the SD card automatically. You can press the escape button ESC to zoom in (2x digital zoom). If you press and hold the escape button ESC for a few seconds, the image on the screens gets mirrored.
5.3 View data
To view the stored pictures and videos, press the up or down button in standard viewing mode. Now you can use these buttons to navigate through all pictures and videos. The data is sorted by date of recording. To delete a file, select it and press the OK button. A confirmation window appears on the display. Use the up ▲ or down ▼button to choose “Yes” if you want to delete the file or choose “No” to cancel. After selecting the desired option, press the OK button to confirm.
Page 8
Manual
8
5.4 Settings
Press the OK button in standard viewing mode to enter the settings menu. Here you have the following options:
DELETE ALL FILES
AV OUTPUT
DATE / TIME
LANGUAGE
TV SYSTEM
AUTO POWER OFF
Reset
To set the device back to factory default settings, press the reset button on the back of the device.
Delete all files
To delete all files, select the “DELETE ALL FILES” option in the settings and press the OK button. After that, use the up and down button to select “Yes” if you want to delete all files or select “No” to cancel. After selecting the desired option, press the OK button to confirm.
AV output
Connect the AV out to an external display unit, choose the “AV OUTPUT” option and press the OK button. The display of the endoscope turns black and the image is shown on the external display unit. To exit this mode, press the OK button again.
Date / Time
To adjust the time and date settings, select the “DATE / TIME” option and press the OK button. Now you can use the up and down button to move between the parameters year, month and day, as well as
hours, minutes and seconds. Move to the desired parameter and use the photo and video button to adjust the value.
If you want the date and time to be displayed on each picture and video, move to the “Display” option and
choose “Yes”. Choose “no” if you do not want date and time to be shown on each picture and video.
Language
To change the language of the device, select the “LANGUAGE” option and press the OK button. Now you are in the language selection screen. Use the up and down button to select the desired language and press the OK button to confirm.
TV system
To change the TV system / video output format, select the “TV SYSTEM” option and press the OK button. Here you can choose between “PAL” and “NTSC”. Use the up ▲ and down button to select the
desired option and press the OK button to confirm. Auto power off
To adjust the auto power off settings, select the “AUTO POWER OFF” option and press the OK button. Now you can choose between different time settings. Select the desired option by using the up and down button and press the OK button to confirm.
Page 9
Manual
9
6 HR camera cable (PCE-VE 3xxHR or optional)
6.1 Safety notes
In addition to the general safety notes of the PCE-VE 3xxN device, please mind the following safety notes to prevent damage and injuries when using the HR camera cable.
To avoid dangerous situations, make sure that the probe does not get in touch with inflammable liquids or gases.
The HR cable includes various small cables which control the optics and electronics of the camera tip. To ensure high reliability, do not bend the cable to an angle of more than 90 ° and store the cable as little bent as possible.
Do not disassemble the device as this can cause damage and electric shocks.
Do not expose the device to direct sunlight and store it in a cool, dry, sufficiently ventilated
place.
To protect the camera module, make sure the protection ring is on the camera head as long as no accessories are in use.
Do not apply force to the end of the cable and do not bend it. This can deteriorate your vision and even damage the probe.
When you roll up the cable, the inner diameter must be at least 15 cm.
Put the protection ring back on and tighten it when not using the device for a longer period of time.
Page 10
Manual
10
Do not crash the probe head.
Make sure that the camera does not get in
contact with the following liquids: lead-free petrol, diesel oil, machine oil, brake fluid, transmission oil and water.
Do not screw the accessories on too tightly. Only screw it slightly until it is fixed.
To clean the camera head, use the cleaning liquid and the swabs provided in the cleaning kit.
6.2 Technical specifications
Length of camera head
20 mm
Diameter with protection ring
6 mm
Depth of field
10 … 60 mm
Field of view
60.7 °
Protection class
IP67
Page 11
Manual
11
6.3 System description
1. Probe: to guide the camera
2. Camera head: for illumination and capturing
3. Assembly ring: to attach accessories
4. Protection ring: to protect the thread
5. Red cap: protects the camera when not in use
6. Boost key: for better illumination in dark environments
7. Rotation key: Press once to turn the display counter-clockwise by 90 °. The red LED will light up. The LED will stop glowing when the original position has been reached.
8. Light key: This key activates a mirror which enables particle-free vision.
9. Connector
Page 12
Manual
12
6.4 Getting started Connection
Step 1: Connect the main unit with the connector and fix it with the screw mechanism. Step 2: Switch on the system. You should now see a picture in the display.
Attachment of the accessories Mirror
Step 1: Unscrew the thread protection ring. Step 2: Screw the assembly ring down to the bottom. Step 3: Screw the mirror attachment onto the thread until the thread is completely covered.
Step 4: Align the lateral LED opening of the mirror attachment in a way that the LEDs are uncovered. Step 5: Turn the assembly ring upwards in order to fix the mirror attachment.
Step 6: Press the light key to activate the lateral light. Step 7: Adjust the light intensity as required to ensure ideal vision to the side.
(Steps 4-5 must be repeated until the right position is reached)
Page 13
Manual
13
Magnetic hook
Step 1: Turn the assembly ring down to the bottom. Step 2: Screw the magnetic hook on until it snaps in.
Climbing ball
Step 1: Remove the assembly ring. Step 2: Screw the climbing ball on until it snaps in.
6.5 Operation
Boost key
Use this key in a dark environment. The red LED indicates that the Boost function has been activated. The image will be lightened up. Note: Hold the probe steady.
Before “boosting”
After “boosting”
Page 14
Manual
14
Rotation key
You can use this key to turn the image by 90 ° four times, for instance, when trying to read an inscription completely.
Light key
When using the mirror attachment, this key improves the vision which will not be impeded by particles, dust, etc.
Without “particle free” function
With “particle free” function
Page 15
Manual
15
7 Articulating camera cable (PCE-VE 350N / HR / N3 / HR3 only or optional)
7.1 Safety notes
In addition to the general safety notes of the PCE-VE 3xxN device, please mind the following safety notes to prevent damage and injuries when using the pivoting camera head.
Do not bend the pivoting camera head by hand. Only use the rotary switch to adjust the angle.
Do not try to rotate the rotary switch any further when it has already been rotated all the way to
the stop.
Do not expose the device to extreme temperatures, direct sunlight, extreme air humidity or moisture. Only use the pivoting camera head at temperatures between 0 and +55 °C.
If you coil up the camera cable for storing, make sure the diameter is at least 15 cm and that the camera head is in a straight position.
Do not expose the camera head to mechanical strains and stresses.
Page 16
Manual
16
7.2 System description
1. Camera cable
2. Camera head
3. Gooseneck
4. Operating unit
5. Rotary switch for gooseneck
6. Connecting cable
7. Connector
8. Locking lever
7.3 Getting started
Connect the connecting cable to the display unit of the endoscope and screw it tightly. Make sure that the indication on the connector is on the upper side.
Page 17
Manual
17
7.4 Operation
1. By using the rotary switch, you can pivot the camera head. Turn the switch in a clockwise motion to pivot the camera head to the right or in a counter-clockwise motion to pivot the camera head to the left.
2. You can lock the pivoting angle of the camera head by using the red locking lever. To lock the camera head, carefully push the lever clockwise all the way to the stop. To unlock the camera head carefully push the lever counter-clockwise, until it reaches its starting point.
Page 18
Manual
18
8 HR camera cable with 360° articulating camera head (PCE-VE 370HR3 or
optional)
8.1 Safety notes
In addition to the general safety notes of the PCE-VE 3xxN device, please mind the following safety notes to prevent damage and injuries when using the HR camera cable with 360° articulating camera head.
To avoid dangerous situations, make sure that the probe does not get in touch with inflammable liquids or gases.
Do not disassemble the device as this can cause damage and electric shocks.
To protect the camera module, make sure the protection ring is on the camera head as long as
no accessories are in use.
Do not bend the articulating camera head by hand. Only use the joystick to adjust the angle.
Do not expose the device to extreme temperatures, direct sunlight, extreme air humidity or
moisture. Only use the device at temperatures between 0 and +60 °C. Store it in a cool, dry,
sufficiently ventilated place.
If you coil up the camera cable for storing, make sure the diameter is at least 15 cm and that the camera head is in a straight position.
Do not expose the camera head to mechanical strains and stresses.
8.2 Technical specifications
Camera head diameter
6 mm
Camera cable
Length: 3 m; water proof
Swivel mechanism
Camera head can be swivelled by 110° in all directions
Illumination
3 LEDs
Operating and storing temperature
0 … +60 °C
Weight
800 g
8.3 System description
1. Joystick
2. Rotation key
3. Light key
4. Boost key
Page 19
Manual
19
8.4 Getting started Attachment of the accessories
Mirror
Step 1: Unscrew the thread protection ring. Step 2: Screw the assembly ring down to the bottom. Step 3: Screw the mirror attachment onto the thread until the thread is completely covered.
Step 4: Align the lateral LED opening of the mirror attachment in a way that the LEDs are uncovered. Step 5: Turn the assembly ring upwards in order to fix the mirror attachment.
Step 6: Press the light key to activate the lateral light.
(Steps 4-5 must be repeated until the right position is reached)
Page 20
Manual
20
8.5 Operation
Hold the device with one hand and use your thumb for operating the joystick and the function keys. With your index finger, you can use the boost key.
Use the joystick to adjust the swivelling angle and direction of the camera head.
Boost key
Use this key in dark environments to lighten up the image. Note: Hold the camera cable steady to get a clear image.
before “boosting” after “boosting”
Page 21
Manual
21
Rotation key
Use this key to rotate the image by 90 °, for instance, when trying to read an inscription completely.
Light key
Use this key in combination with the mirror attachment to improve the vision which will not be impeded by particles, dust, etc.
without “particle free” function with “particle free” function
Page 22
Manual
22
9 PCE-VE 380N
9.1 Safety notes
In addition to the general safety notes of the PCE-VE 3xxN device, please mind the following safety notes to prevent damage and injuries when using the camera cable and the accessories of the PCE-VE 380N.
When rolling the camera cable out or in, be very careful to prevent mechanical damage due to tensile or compressive strain.
You can move the camera cable around corners from 90° upwards. If the corner is narrower than 90°, this might interfere your measurement and even cause damage to the product.
Do not use the camera cable to inspect fuel tanks or other environments with explosive or inflammable atmospheres.
To clean the whole set, wash it with water and dry it with a cloth or let it dry. Do not sluice it with a hose or a high-pressure cleaner.
Do not expose the device to direct sunlight and store it in a cool, dry, sufficiently ventilated place.
9.2 Technical specifications Cable drum
Diameter
300 mm
Operating temperature
-10 … +60 °C
Weight
3.5 kg
Cable
Diameter
6 mm
Length
30 m
Bending radius
150 mm
Weight
100 g/m
Camera head
Camera diameter
28 mm
Camera length
24.3 mm
Depth of field
10 mm …
Field of view
150.8 ° (diagonal)
Lighting
8 LEDs (white)
Operating temperature
-10 … +60 °C
Fitting pipe diameters
Ø 40 … 100 mm
Cable measuring device
Measuring units
m / ft
Counting
Forward / backward
Accuracy
±0.4 m (±1.3 ft)
Display
3 digits (1 decimal place)
Protection class
IP 55
Power supply
2 x 1.5 V AAA batteries
Battery life
90 hours
Dimensions
62 x 110 x 24 mm
Page 23
Manual
23
9.3 System description
PCE-VE 380N
1. Connection to display unit
2. Support for display unit
3. Handle
4. Camera head
5. Support for camera head
6. Cable measuring device
7. Power button for transmitter
Cable measuring device
1. ON/OFF/RESET button
2. m/ft button
3. Display backlight button
4. Battery compartment
Page 24
Manual
24
Camera cable
1. Camera head
2. Semi-flexible camera cable
3. Connection
4. Camera cable
5. Mounting ring
9.4 Getting started
Battery replacement Transmitting unit
The battery compartment of the transmitting unit is located at the back of the unit. To open it, you have to loosen a screw first. After that, you can open the battery compartment and replace the batteries.
Page 25
Manual
25
Cable measuring device
The battery compartment of the cable measuring device is located at the front, right below the function keys. To open it, you have to loosen a screw first. After that, you can open the battery compartment and replace the batteries.
Installation
1. Place the display unit in the support.
2. Connect the camera cable to the display unit and screw it tightly.
You can adjust the angle of the display support at any time, but do not use angles smaller than 90° cause this might damage the support.
Page 26
Manual
26
The PCE-VE 380N can also be used in horizontal position.
9.5 Operation
Pulling out the cable
1. Before pulling out the camera cable, loosen the cable drum fixing first.
2. Pull out the camera cable horizontally. Do not pull it out in an angle larger than 45° to the camera head support.
Page 27
Manual
27
3. Once you have reached the desired cable length, fix the cable drum to prevent it from rolling out any further.
Coiling up the cable
1. Hold the camera head horizontally and carefully coil up the cable.
2. When the camera cable is coiled up completely, place the camera head in the camera head support.
4. Fix the cable drum to prevent the cable from rolling out.
Page 28
Manual
28
Cable measuring device
To turn on the device, press and hold the OF/OFF button for 3 seconds. You can reset/restart the device at any time by pressing and holding the ON/OFF button for 1 second.
To switch the measuring unit between m and ft, press the “m/ft” button.
Press the backlight button to activate the display backlight. The display backlight is active for 10 seconds.
To turn off the device, press and hold the ON/OFF button for 3 seconds. The device also has an automatic power-off function which turns it off automatically after 1 hour of idling time.
If the display shows a battery indication , please replace the batteries.
Centring star
1. Put the camera head in the centring star attachment and align the mounting ring with the screw holes.
2. Put the screws in the screw holes and fasten the camera head.
Screw hole
Page 29
Manual
29
Cleaning
1. Remove the display unit from the support.
2. Put the protecting hood on the connector of the camera cable.
3. Wash the cable drum with water and let it dry for a few minutes.
4. If necessary, dry the cable drum with a dry cloth before putting it back into the carrying case.
9.6 Locator PCE-VE-LOC (optional or PCE-VE 380N-LOC) Safety notes
This product is designed for industrial use only. Do not use the system for human or biological inspection.
Do not use the camera cable to inspect fuel tanks or other environments with explosive or inflammable atmospheres.
Do not try to disassemble this product to avoid damage or electric shocks.
Only use original or recommended components or accessories. Unapproved accessories and
components may cause damage.
Page 30
Manual
30
Product description
1 DC jack 5 Depth measurement key 2 Backlight key 6 On / Off key 3 Reset key 7 Buzzer key 4 Handle 8 Unit key (m / ft)
1
2
4
5
6 7 8
Page 31
Manual
31
DC jack
To connect mains adaptor for charging
Backlight key
Backlight can be switched on or off
Reset key
Reset, e. g. when depth measurement failed
Handle
Depth measurement key
To identify the depth of the transmitter On / Off key
To switch on / off
Buzzer key
To switch on / off buzzer sound that occurs when locator is switched on and when moving closer to the transmitter
Unit key (m / ft)
To switch the units of depth measurement
Mounting
1 Main system connector 4 Camera head stopper 2 Handle 5 Meter 3 Camera head 6 Power button for transmitter
Page 32
Manual
32
Display
1 Detection icon 2 Signal strength 3 Low battery alert The battery must be charged whenever the low battery alert appears on the screen.
Icon
Description
Weak signal, hard to verify directions
You can follow the directions of the arrow to move on
Depth measurement icon: appears when you are within the measurable range (horizontal 4.5 m / 15 f, vertical 1.8 m / 5.9 f), i. e. a depth measurement can be made and the reading is displayed along with peak signal strength
Depth measurement failed. Reset and wait a few seconds for the reading to stabilise. A stable reading is indicated by an icon.
Operation
Turn on the borescope as well as the locator.
Before placing the transmitter in the target location, move the locator to check the signal strength
(see “Quick calibration”). Also check the depth measurement icon as well as the battery level.
The lamp next to the power button for the transmitter should glow in green. If the lamp glows in red, the battery voltage is insufficient and the instrument is not ready to work. The battery will last no longer than 15 minutes when the red lamp starts glowing.
Page 33
Manual
33
Move the locator carefully and do not change the height, if possible.
Localisation every 5 m is recommended.
To find the best signal strength, follow the arrows on the screen.
When you come closer to the transmitter, the intervals of the beeping sound will become shorter.
When you have reached the signal peak, turn the locator counterclockwise until the depth
measurement icon pops up. Then press the depth measurement key to get the result.
Page 34
Manual
34
Quick calibration
Place the antenna of the locator approx. 100 cm / 3 f away from the transmitter.
Check the signal strength.
If the signal strength is below 60 %, press the reset key. Repeat these steps until the signal
strength is sufficient.
Technical specifications
Locator PCE-VE-LOC
Dimensions
L : 293.5 mm W : 144 mm H : 486.5 mm
Weight
2 kg
Power supply
3.7 V / 2000 mA Li battery
Power consumption
282 mA
Charging duration
3 … 4 h
Battery life
6 … 7 h
Power adaptor
5.5 V, 1.8 A
Humidity
95 % RH, non-condensing
Working temperature
-10 … 60 °C
Storage temperature
-20 … 80 °C
Drop resistance
60 cm
IP protection
IP55
Transmitter
Power supply
2 x AAA batteries
Power consumption
3.4 V / 230 mA
Battery life
Approx. 3 … 4 h
10 PCE-VE 390N
10.1 Safety instructions
Do not use the camera cable to inspect fuel tanks or other environments with explosive or inflammable atmospheres.
When bending or rolling up the camera tube make sure that the bending diameter is more than 30 cm. Otherwise it can cause damage to the tube.
Pay attention when pushing the camera tube in the object to be inspected or when pulling it back out. The camera tube is a high-strength structure which can be used for pushing obstacles in pipes. However, due to its rigidity, it might unwind from the carrying system when pulling it out.
Do not expose the device to direct sunlight and store it in a cool, dry, sufficiently ventilated place.
The display unit is not waterproof. Remove the display unit and the connector before cleaning the
camera tube and the carrying system.
Page 35
Manual
35
10.2 Technical specifications Carrying system
Dimensions
490 x 450 x 60 mm
Weight
1222 g (without display unit and camera tube)
Camera tube
Length
10 m
Diameter
6 mm
Bending diameter
30 cm
Weight
100 g / meter
Camera head
Diameter
28 mm
Length
24.3 mm
Depth of field
10 mm … ∞
Field of view
150.8 °
Illumination
8 LEDs (white)
Environmental temperature
-10 … +70 °C
Protection class
IP 68 (10 m)
Pipe diameter
Ø 40 mm … Ø 100 mm
Page 36
Manual
36
10.3 System description
Carrying system
1. Neck strap
2. Carrying system
3. Hip belt
10.4 Getting started
Inserting the display unit
Insert the display unit into the carrying system as seen in the picture above. Use the connecting cable to connect the display unit to the camera tube, Roll up the camera tube on the carrying system.
Attaching and wearing the carrying straps
Page 37
Manual
37
Step 1 / 2:
Attach the neck strap to one of the upper supports, put it around your neck and attach the other end to the other upper support of the carrying system.
Attach the hip belt to one of the lower supports, put it around your hip and attach the other end to the other lower support of the carrying system.
Step 3:
Turn on the device.
Step 4:
Unwind the camera tube until you have reached the desired length.
Page 38
Manual
38
11 Disposal
For the disposal of batteries, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
If you have any questions, please contact PCE Instruments.
12 Contact
If you have any questions about our range of products or measuring instruments please contact PCE Instruments.
12.1 PCE Instruments UK By post:
PCE Instruments UK Ltd. Unit 11 Southpoint Business Park Ensign Way, Southampton Hampshire
United Kingdom, SO31 4RF By phone:
02380 987 035
12.2 PCE Americas By post:
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter 33458 FL USA
By phone: 561 3209162
Loading...