Your purchase of this
VIBRATION DATA
RECORDER marks a
step forward for you
into the eld of
precision measurement.
Although this Meter is a
complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.
OPERATION
10. SYSTEM RESET...............................................................................................19
11
12
1
2
5
6
9
9
11. RS232 PC serial interface.................................................................................20
Page 3
1. FEATURES
* Applications for industrial vibration monitoring :
All industrial machinery vibrates. The level of vibration is
a useful guide to machine condition. Poor balance,
misalignment & looseness of the structure will cause the
vibration level increase, it is a sure sign that the
maintenance is needed.
* Frequency range 10 Hz – 1kHz, sensitivity relative meet
IOS 2954.
* Profressional vibration meter supply with vibration sensor
& magnetic base, full set.
* Metric & Imperial display unit.
* Acceleration, Velocity measurement.
* RMS, Max hold , Peak value measurement.
* Max. Hold reset button, Zero button.
* Wide frequency range.
* Data hold button to freeze the desired reading.
* Memory function to record maximum and minimum
reading with recall.
* Separate vibration probe with magnetic base, easy operation.
* Real time SD memory card Datalogger, it Built-in Clock
And Calendar,real time data recorder, sampling time set
From 5 second to 3600 seconds.
* Innovation and easy operation, computer is not need
to setup extra software, after execute datalogger, just
take away the SD card from the meter and plug in the
SD card into the computer, it can down load the all the
measured value with the time information(
year/month/date/hour/minute/second) to the Excel
directly, then user can make the further data or graphic
analysis by themselves.
* SD card capacity : 1 GB to 16 GB.
1
Page 4
* LCD with green light backlight, easy reading.
* Can default auto power off or manual power off.
* Data hold, record max. and min. reading.
* Microcomputer circuit, high accuracy.
* Power by UM4/AAA( 1.5V ) x 6 batteries or DC 9V adapter.
* RS232/USB PC COMPUTER interface.
2. SPECIFICATIONS
2-1 General Specifications
CircuitCustom one-chip of microprocessor LSI
circuit.
DisplayLCD size : 60 mm x 50 mm
Measurement
Memory CardSD memory card. 1 GB to 16 GB.
Datalogger5/10/30/60/120/300/600/1800/3600 seconds
Sampling Time
Acceleration,Velocity
Data error no.
Advanced
setting
≦ 0.1 % no. of total saved data typically.
* Set clock time ( Year/Month/Date, Hour/Minute/
Second )
* Set sampling time
* Set Auto Power OFF
* Set beeper sound ON/OFF
* Set SD card Decimal character
* SD memory card Format
* Set UNIT
Update TimeApprox. 1 second if measuring data
of Displayis changed.
Temperature
Operating Less than 85% R.H.
Humidity
Power Supply* DC 9V adapter input. ( AC/DC power
* Meter &adapter is included ).
probe
Power Supply* Alkaline or heavy duty DC 1.5 V battery
* Clock backup( UM4, AAA ) x 6 PCs, or equivalent.
battery
Weight199 g/0.44 LB.
Dimension132 x 80 x 32 mm
( 5.2 x 3.1 x 1.3 inch )
Accessories*
Included*
Optional
Accessories
*
* SD Card ( 2 GB )
* 2 wires pressure transmitter, TR-PS2W
* USB cab
* RS232 cable, UPCB-02.
* Data Acquisition software, SW-U801-WIN.
* Excel Data Acquisition software, SW-E802.
le, USB-01.
1 pcs.
1 pcs.
1 pcs.
* AC-AP9VA (AC to DC 9V adapter)
Page 6
3
2-2 Electrical Specifications (23±5 ℃℃℃℃ )
FunctionUnitRange and ResolutionAccuracy
Acceleration m/s20.5 to 199.9 m/s2
g0.05 to 20.39 G± ( 5%rdg + 2 d )
ft/s22 to 656 ft/s2@ 80 and 160Hz
Calibration Point: 50 m/S^2 ( 160 Hz )
Velocitymm/s0.5 to 199.9 mm/s
cm/s0.05 to 19.99 cm/s± ( 5%rdg + 2 d )
inch/s0.02 to 7.87 inch/s@ 80 and 160Hz
Calibration Point: 50 mm/s ( 160 Hz )
Above specification tests under the environment RF Field Strength
less than 3 V/M & frequency less than 30 MHz only and 23°C ±0.5°C
Page 7
4
3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Display3-12
3-2 Power button ( Backlight button )3-13 Screw of the battery cover
3-3 ▲ Button ( Unit Button )
3-4 REC Button ( HOLD Button )3-15 Reset Button
3-5 SET Button ( Time Button )3-16 RS-232 Output Terminal
3-6 ▼ Button ( Function Button )
3-7 Logger button ( Enter button )3-18 4-20 mA Output Terminal
3-8 Vibration Sensor input BNC socket 3-19 Reset Button
3-9 DC 9V power adapter input socket 3-20 Vibration Sensor
3-10 Hanging holes3-21 Vibration Sensor BNC
3-11 Stand
Battery cover/Battery compartment
3-14 Hanging unit ( with sticker )
3-17 SD card socket
Page 8
5
AC to DC adapter
4. MEASURING PROCEDURE
1) Power supply installation :
* The
* The batteries are the power of " Clock ".
Batteries
Install the batteries into the battery compartment :
* Loose the " Screw of the battery cover " ( 3-13, Fig. 1 )
* Replace with DC 1.5 V battery ( UM4/AAA, Alkaline/Heavy
* Make sure the battery cover is secured after changing
* The " AC to DC adapter " is the standard accessory.
* Plug the output plug of " AC to DC adapter " into
2) Vibration Sensor
Connect the vibration pickup to the cable supplied
Make sure it is firmly attached. Connect the cable
to the meter by attaching it to the "BNC connector( 3-8, Fig. 1 )
on the Bottom of the meter.If the surface to be tested is magnetic,
attach the magnetic base to the vibration pickup and attach the
pickup to a flat surface.If the surface to be tested is not magnetic,
hold the pickup against the surface. Do not hold the cable while
making measurements.
meter's power supply should install the batteries
and connect " AC to DC adapter " together.
and take away the " Battery Cover " ( 3-12, Fig. 1 ) from
the meter.
duty type ) x 6 PCs, and reinstate the cover.
the battery.
the " DC 9V power adapter input socket " ( 3-9, Fig. 1 )
Page 9
3) Vibration unit
The currently selected unit of measure is shown on the
meter’s LCD. To change the unit of measure, press and hold
the ▲ Button " Unit Button ( 3-3, Fig. 1 )" until the desired unit
of measure appears and then release the button.
if want change metric or imperial please refer chapter 7-7 (page 18 ).
4) Function Selection
The currently selected function is shown on the meter’s
LCD. To change the function, press and hold the button.
"FUNCTION button( 3-6, Fig. 1 )" until the desired function
appears, then release the FUNCTION .
The available functions are:
RMS: Typical selection for Acceleration and Velocity
PEAK: Displays the peak value of the vibration
MAX HOLD: Displays and holds the max value measured
MAX HOLD Reset:
Press and hold the ▲ and ▼ buttons for > 3 seconds to clear the
Max. Hold reading.
Page 10
7
5) Data Hold:
To freeze a displayed reading on the LCD, momentarily press
the"HOLD button ( 3-4, Fig. 1 )" (the HOLD icon will appear
above the reading). To exit HOLD, press the HOLD button again.
6) ZERO Adjustment
The ZERO function is used to remove any small offset caused
by temperature changes or other environmental changes.
The zero will only work for a display of 10 or less digits.
1. Connect the vibration sensor to the meter
2. Set the measurement function to Acceleration
3. Make sure the sensor is motionless and not subject to
any vibrations.
4. Press and Hold the ▼ and ▲buttons for 3 seconds and the
meter will show zero .
7) REC ( Record):
For a given measurement session, this meter can record the
highest (MAX) and the lowest (MIN) readings for later recall.
1. Press the REC button momentarily to access this mode
of operation (REC icon appears)
2. The meter is now recording the MAX and MIN readings.
3. Press the REC button again to view the current
MAX readings (MAX icon appears). The readings on the
display are now the highest readings encountered since
the REC icon wasswitched on (when the MAX-MIN button
was first pressed).
4. Press the REC button again to view the current MIN
readings (MIN icon appears). The readings on the display
are now the lowest readings encountered since the REC icon
was switched on (when the REC button was first pressed).
5. To exit the MAX-MIN mode, press and hold the REC
button for 3 seconds. The meter will beep, the REC-MAX-MIN
icons will switch off, the MAX-MIN memory will clear,
and the meter will return to the normal operating mode.
Page 11
8
8) Time check :
Press the "Time button ( 3-5, Fig. 1 )" once,display will be show
Year/Month/Date, Hour/Minute/ Second and samling time
information.
9) 4-20 mA output :
connect anather mA meter in to the viberation data recorder
(3-18 Fig. 4-20 mA Output Terminal) socket,At this time the
viberation data recorder will be output 4 - 20 mA analog signal
( display show 0 = 4.00mA out, show full scale = 20.00 mA out).
5. DATALOGGER
5-1 Preparation before execute datalogger function
Insert the SD card
Prepa
re a " SD memory card " ( 1 GB to 16 GB, optional ),
insert the SD card into the " SD card socket " ( 3-17, Fig. 1)
with the correct direction exactly.
*
It recommend use memory card's capacity is ≦≦≦≦ 4 GB.
* It recommend strongly, do not use memory cards
tha
t have been formatted by other meter or by
other installation ( such as camera... ). Reformat
the memory card with your meter.
* If the SD memory card exist the trouble during
format by the meter, use the Computer to
reformat again can fix the problem.
Page 12
c. Time setting
If the meter is used at first time, it should to adjust the
clock time exactly, please refer chapter 7-1 ( page 15 ).
d. Decimal format setting
The numerical data structure of SD card is
default used the " . " as the decimal, for
example "20.6" "1000.53" . But in certain
countries ( Europe ...) is used the " , " as the
decimal point, for example " 20, 6 " ,
"1000,53". Under such situation, it should
change the Decimal character at first, details
of setting the Decimal point, refer to Chapter
7-5, page 17
e. 3 Information of LCD display
* If the Display show :
It means that the SD card exist the problem
CHANGE
SD CARD
or the SD card memory is full, it should
change SD memory card.
uously, until the Display show the indicator "
DATALOGGER ", release the " Logger Button " ( 3-7, Fig.
1 ), then the measuring data along the time information
will be saved into the memory circuit.
Remark :
*
How to set the sampling time, refer to Chapter 7-2,
page
15.
*
How to set the beeper sound is enable, refer to
Chapt
er 7-4, page 16.
b. Finish the Datalogger
During execute the Datalogger function ( Display show the
" Datalogger " indicator ), press the " Logger button " ( 3-7,
Fig. 1 ) > 2 seconds continuously, until the Display
indicator " DATALOGGER " is disappeared, release the
" Logger Button " will finish the Datalogger function.
Before take away the SD card from the
meter, it should execute the
procedures of " Finish the Datalogger ",
( It should wait for the Display counter to count
do
wn to zero value. )
otherwise some existing recent save
data
may loss.
11
Page 14
5-3 Check time information
1) WhentheSDcardisusedintothemeter,theSDcard
2)
3)
4)
Press " Time button " ( 3-5, Fig. 1 ) > 2 seconds
continuously, the LCD display will present the time
information of Year/Month/Date, Hour/Minute/Second and
the sampling value.
5-4 SD Card Data structure
When the first time, the SD card is used into the meter,
the SD card will generate a folder :
VBC01
If the first time to execute the Datalogger, under the
route VBC01\, will generate a new file name
VBC01001.XLS.
After exist the Datalogger, then execute again, the data
will save to the VBC01001.XLS until Data column reach
to 30,000 columns, then will generate a new file, for
example VBC01002.XLS
Under the folder VBC01\, if the total files more
than 99 files, will generate anew route, such as
VBC02\ ........
The file's route structure :
VBC01\
VBC01001.XLS
VBC01002.XLS
.....................
VBC01099.XLS
VBC02\
VBC02001.XLS
VBC02002.XLS
.....................
VBC02099.XLS
VBCXX\
.....................
Remark :
XX : Max. value is 10.
12
Page 15
6. Saving data from the SD card
to the computer ( EXCEL software )
1) After execute the Data Logger function, take away the
SD c
ard out from the " SD card socket " ( 3-17, Fig. 1 ).
2) Plug in the SD card into the Computer's SD card slot
( if your computer build in this installation ) or
insert the SD card into the " SD card adapter ". then
connect the " SD card adapter " into the computer.
3) Power ON the computer and run the " EXCEL software ".
Down load the saving data file ( for example the file
name : VBC01001.XLS, VBC01002.XLS ) from the SD
card to the computer. The saving data will present into
the EXCEL software screen ( for example as following
EXCEL data screens ) , then user can use those EXCEL
data to make the further Data or Graphic analysis
usefully.
EXCEL data screen ( for example )
13
Page 16
EXCEL graphic screen ( for example )
SET DATE......
POFF........
UNIT……..
7. ADVANCED SETTING
Under do not execute the Datalogger function, press the
"
SET bu
enter the " Setting " mode., then release the " SET button ".
Following press the " SET button " (3-5, Fig. 1 ) once a
while in sequence to select the seven main function, the
display will show :
Second )
Set sampling time
Set Power Auto OFF
Set beeper sound ON/OFF
Set SD card Decimal character USA/EURO
METRIC / IMPERIAL
14
Page 17
Remark :
During execute the " Setting " function, if within
5 seconds , do not press any buttons further, the
LCD Display will return to normal screen.
7-1 Set clock time ( Year/Month/Date,
Hour/Minute/ Second )
When the Display show " SET DATE "
1)
Use the " ▲ Button " ( 3-3, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to adjust the value ( Setting start from
Year value ). After the desired value is set, press the
" Enter button " ( 3-7, Fig. 1 ) once will going to
next value adjustment ( for example, first setting
value is Year then next to adjust Month, Date, Hour,
Minute, Second value ).
Remark :
The adjusted unit will be flashed.
2) After set all the time value ( Year, Month, Date, Hour,
Minute, Second ), press the " SET button " ( 3-5, Fig.
1 ) once will save the time value, then the screen will
jump to Sampling time " setting screen ( Chapter 7-2 ).
Remark :
After the time value is setting, the internal clock will
run precisely even Power off if the battery is under
normal condition ( No low battery power ).
7-2 Set sampling time
When the Display show " SP-T "
1)
Use the " ▲ Button " ( 3-3, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to adjust the sampling value :
After the desired value is set, press the " Enter Button "
( 3-7, Fig. 1 ) to save the adjusting value with default.
7-3 SET POFF ON/OFF
When the Display show " POFF "
1)
Use the " ▲ Button " ( 3-3, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to select the text to " yES " or " no ".
YES - Meter's will be Auto power off .
NO - Meter's Auto power off Will be disable.
2) After select the upper text to " YES " or " NO ", press the
" Enter Button " ( 3-7, Fig. 1 ) will save the setting
function with default.
7-4 Set beeper sound ON/OFF
When the Display show " BEEP "
1)
Use the " ▲ Button " ( 3-3, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to select the text to " YES " or "NO ".
YES - Meter's beep sound will be ON with default.
NO - Meter's beep sound will be OFF with default.
2) After select the upper text to " YES " or " NO ", press the
" Enter Button " ( 3-7, Fig. 1 ) will save the setting
function with default.
16
Page 19
7-5 Decimal point of SD card setting
When the Display show " DEC "
The numerical data structure of SD card is used the " . "
as the decimal with default, for example "20.6"
"1000.53" . But in certain countries ( Europe ...) is
used the " , " as the decimal point, for example " 20,6 "
"1000,53". Under such situation, it should change the
Decimal character at rst.
1)
Use the "
( 3-6, Fig. 1 ) to select the upper text to " USA " or
" EURO ".
USA - Use " . " as the Decimal point with default.
EURO - Use " , " as the Decimal point with default.
2) After select the text to " USA " or " EURO ",
press the " Enter Button " ( 3-7, Fig. 1 ) will save the
setting function with default.
Button " ( 3-3, Fig. 1 ) or " Button "
17
Page 20
7-6 Set UNIT
When the Display show "UNIT METRIC "
1)
Use the " ▲ Button " ( 3-3, Fig. 1 ) or " ▼ Button "
( 3-6, Fig. 1 ) to select the upper Display text to METRIC
or IMPERIAL
2) press the " Enter Button " ( 3-7,
Fig. 1 ) will save the setting METRIC or IMPERIAL with default.
18
Page 21
8. POWER SUPPLY from DC
ADAPTER
The meter also can supply the power supply from the DC
9V Power
" DC 9V Power Adapter Input Socket " ( 3-9, Fig. 1 ).
Adapter. Insert the plug of Power Adapter into
9. BATTERY REPLACEMENT
1) When the left corner of LCD display show " ", it
is nece
measurement may still be made for several hours after
low battery indicator appears before the instrument
become inaccurate.
2) Loose the " Screw of the battery cover " ( 3-13, Fig. 1 )
and take away the " Battery Cover " ( 3-12 Fig. 1 ) from
the instrument and remove the battery.
3) Replace with DC 1.5 V battery ( UM4/AAA,
Alkaline/heavy duty ) x 6 PCs, and reinstate the cover.
4) Make sure the battery cover is secured after changing
the battery.
ssary to replace the battery. However, in-spec.
10. SYSTEM RESET
If the meter happen the troubles such as :
CPU sys
not be operated... ).
Then make the system RESET will fix the problem.
The system RESET procedures will be either following
method :
During the power on, use a pin to press the " Reset
Button " ( 3-15, Fig. 1 ) once a while will reset the
circuit system.
tem is hold ( for example, the key button can
19
Page 22
11. RS232 PC SERIAL INTERFACE
Center Pin............................................