PCE Instruments PCE-TSM 5 Users guide

Page 1
Sound Level Meter
PCE-TSM 5
User's Manual
Please read this user manual thoroughly before using this unit
and keep it properly for your future reference.
Page 2
1
Catalogue
2Applications.............................................................. 2
3Features .................................................................... 3
4Specifications ........................................................... 4
5Meter Description ..................................................... 6
6Display Description .................................................. 7
7Function Operation Description ............................... 7
8Notes ........................................................................11
9Accessories ............................................................. 13
9、Disposal ................................................................... 13
Page 3
2
1 Safety
Read the following safety information carefully before attempting to operate the meter.
Environment conditions
1RH≤90%(Non-Condensation 2Operating Temperature: -2060℃/-4140
Maintenance
1Repairs or servicing should only be performed
by qualified personnel.
2Wipe the unit with a dry soft cloth. Do not use
abrasives or solvents on this instrument
Comply with EMC
2Applications
This instrument adopts the capacitive microphone as the sensor, and is equipped with high-configuration MCU
Page 4
3
calculation, with high measurement accuracy and quick response. Suitable for noise engineering, quality control, health prevention and control and various environmental sound measurement, such as construction engineering, factory, school, hospital, library, office, home
3Features
large HD color LCD display Wide frequency response range and high accuracy Light and voice alarm functions Alarm value can be set Preset six countries warning language optional 15S Self defined recording broadcast duration 15S Screen locking function Remote control and remote operation Audio output function
Page 5
4
4Specifications
Measuring range
35dB 135dB
Dynamic range
50dB
Frequency response
31.5Hz 8KHz
Accuracy
±2.0dB
Frequency weighting
A weighted network
Microphone
1/2 inch electret condenser microphone
Value update
500ms
six Languages
English, Spanish, French, German, Japanese, Chinese
Recording function
15S
Over range prompt
135DB, "Hi" symbol is displayed; 35 DB, "LO" symbol is displayed
High alarm value setting
Audio output function
Volume adjustment
Remote control
Page 6
5
Battery life
60hours
Power
AdapterDC 9V/1Aouter diameter
5.5mm, inner diameter 2.0mm, central positive pole
AA LR6 1.5V × 6
Operating temperature and humidity
-20℃60℃/-4℉ 140℉,10%RH 90%RH
Storage temperature and humidity
-20℃60℃/-4℉ 140℉,10%RH 75%RH
Size
197*176*49mm
Weight
623g
Page 7
6
5Meter Description
Display screenRecording holeFunction keysHornInfrared receiving holeFunction keysNoise detection sensorNoise correction fine adjustment holeAudio output holeAdapter jackHanging holeBattery compartment
Page 8
7
6Display Description
Volume identification symbolAdapter access prompt symbolLow voltage prompt symbolNoise value display areaNoise unit symbolScreen lock symbol
7Function Operation Description
1) On/off function;Press the " " button to start
the meter, and press the " " button for 3 seconds to shut down the machine
Page 9
8
2) Alarm function
a. Yellow light alarm, in the measurement mode, when the measurement value is greater than the reported value, the yellow light flashes continuously. b. Red light alarm. in measurement mode, when the measurement value is greater than the alarm value set by the red light, the red light is continuously flashing and the voice is reported (please be quiet).
3) Screen lock function; in the measurement state,
press the " " key, the "HOLD" symbol appears at the top of the screen to indicate that the instrument locks the
current screen display, and again, the " " key to cancel the function
4) Recording function; in measurement mode, press
Page 10
9
the " " button, and hear the "drop", indicating that
the recording begins, release" "the key, and hear
the two sounds of "drop" and "drop", indicating the end of the recording.The instrument will automatically broadcast a recording content.
5) Volume adjustment function; in measurement
mode, press " " to increase the volume and " "
to reduce the volume.
6) Alarm value adjustment function; in the
measurement mode, press the " " button, the instrument can enter the "Yellow Light Alarm Value
Adjustment", "Red Light Alarm Value Adjustment", "Green Light Self Test", "Yellow Light Self Test", "Red
Page 11
10
Light" mode, and press the " " button again to return to the measurement mode. In the alarm value adjustment
mode, press " " key to adjust the large value and
press " " key to adjust the small value.
7) Broadcast voice selection; in measurement mode,
press " " to select the required broadcast language, then select in English, Spanish, French, German,
Japanese, Chinese, homemade recording content.
Note: After pressing the " " key, a voice will be
broadcast. After the voice is played, press the " " key within 3 seconds to jump to the next voice play. If more
than 3 seconds, play the selected voice
Page 12
11
8Correction method; Open the power switch of the standard sound source (94 dB @ 1 KHZ), close the standard source to the induction hole of the noise detection sensor, and rotate the potentiometer in the adjustment hole on the right side of the instrument to display the LCD as 94.0dB.
8Notes
The instrument has been calibrated before leaving the factory. Without any professional equipment and personnel, please do not easily modify the calibration parameters [Note] The instrument has been corrected before leaving the factory, and the recommended correction period is one year.
1) Repairs or servicing should only be performed by
Page 13
12
qualified personnel.
2) Wipe the unit with a dry soft cloth. Do not use
abrasives or solvents on this instrument
3) Remove the battery when the meter is to be stored
for long periods of time to avoid battery leakage.
4) When the battery runs out, the LCD displays the
" " symbol, and the new battery must be replaced.
5) Use adapters to power as much as possible
6) Do not use it in places with high temperature and
high humidity
7) Do not tap the microphone head and remain dry.
Page 14
13
9Accessories
1 x PCE-TSM 5 sound level meter 1 x 9 V 1 A plug-in mains adaptor 1 x remote control 1 x screwdriver 6 x 1.5 V AA battery 1 x user manual 1 x mounting material
Disposal
9
For the disposal of batteries in the EU, the
006/66/EC directive of the European Parliament
2 applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 15
PCE Instruments contact information
Germany
PCE Deutschland GmbH Im Langel 26 D-59872 Meschede Deutschland Tel.: +49 (0) 2903 976 99 0 Fax: +49 (0) 2903 976 99 29 info@pce-instruments.com www.pce-instruments.com/deutsch
United Kingdom
PCE Instruments UK Ltd Trafford House Chester Rd, Old Trafford Manchester M32 0RS United Kingdom Tel: +44 (0) 161 464902 0 Fax: +44 (0) 161 464902 9 info@pce-instruments.co.uk www.pce-instruments.com/english
The Netherlands
PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31 (0)53 737 01 92 info@pcebenelux.nl www.pce-instruments.com/dutch
France
PCE Instruments France EURL 23, rue de Strasbourg 67250 Soultz-Sous-Forets France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 info@pce-france.fr www.pce-instruments.com/french
Italy
PCE Italia s.r.l. Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano Capannori (Lucca) Italia Telefono: +39 0583 975 114 Fax: +39 0583 974 824 info@pce-italia.it www.pce-instruments.com/italiano
United States of America
PCE Americas Inc. 1201 Jupiter Park Drive, Suite 8 Jupiter / Palm Beach 33458 FL USA Tel: +1 (561) 320-9162 Fax: +1 (561) 320-9176 info@pce-americas.com www.pce-instruments.com/us
Spain
PCE Ibérica S.L. Calle Mula, 8 02500 Tobarra (Albacete) España Tel. : +34 967 543 548 Fax: +34 967 543 542 info@pce-iberica.es www.pce-instruments.com/espanol
Turkey
PCE Teknik Cihazları Ltd.Şti. Halkalı Merkez Mah. Pehlivan Sok. No.6/C 34303 Küçükçekmece - İstanbul Türkiye Tel: 0212 471 11 47 Faks: 0212 705 53 93 info@pce-cihazlari.com.tr www.pce-instruments.com/turkish
Denmark
PCE Instruments Denmark ApS Birk Centerpark 40 7400 Herning Denmark Tel.: +45 70 30 53 08 kontakt@pce-instruments.com www.pce-instruments.com/dansk
14