User manuals in various languages (français,
italiano, español, português, nederlands, türk, polski,
русский, 中文) can be found by using our
product search on: www.pce-instruments.com
Last change: 29 December 2021
v1.0

Contents
1 Safety notes ........................................................................................... 1
2 Specifications ........................................................................................ 2
3 Delivery scope ....................................................................................... 2
4 Device description ................................................................................ 3
4.1 Display description ........................................................................................................... 6
5 Battery information ............................................................................... 6
6 Switching on and off ............................................................................. 7
7 Backlight ................................................................................................ 7
8 Making a measurement ........................................................................ 7
9 Zeroing ................................................................................................... 7
10 Contact ................................................................................................. 8
11 Disposal ................................................................................................. 8
© PCE Instruments

© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The
device may only be used by qualified personnel and repaired by PCE Instruments personnel.
Damage or injuries caused by non-observance of the manual are excluded from our liability and
not covered by our warranty.
• The device must only be used as described in this instruction manual. If used otherwise,
this can cause dangerous situations for the user and damage to the meter.
• The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
• Do not expose the device to shocks or strong vibrations.
• The case should only be opened by qualified PCE Instruments personnel.
• Never use the instrument when your hands are wet.
• You must not make any technical changes to the device.
• The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
• The device must only be used with accessories from PCE Instruments or equivalent.
• Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
• Do not use the instrument in explosive atmospheres.
• The measurement range as stated in the specifications must not be exceeded under
any circumstances.
• Non-observance of the safety notes can cause damage to the device and injuries to
the user.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of
business.
If you have any questions please contact PCE Instruments. The contact details can be found at
the end of this manual.

© PCE Instruments
2
2 Specifications
±20 kV DC: 0.01 kV DC
-60 ... -20 kV DC / +20 ... +60 kV DC:
0.1 kV DC
when the meter is switched on, 5 seconds
before automatic power off,
when measurement range is exceeded
0 ... 40 °C, 0 ... 60 % RH, non-condensing
3 Delivery scope
1 x gauss meter PCE-SFS 10
1 x earthing cable
1 x carrying bag
1 x 9 V block battery
1 x user manual

© PCE Instruments
3
4 Device description
"HOLD" key to freeze the display
"ECO" key for switching the backlight on and off

Temperature and humidity sensor

"Zero" key for setting the zero point

© PCE Instruments
6
4.1 Display description
Polarity of the magnetic field
"HOLD" - display is frozen
5 Battery information
The battery life is a maximum of 20 hours. The battery status is continuously shown on the display.
Battery is fully charged.
Battery is partially discharged.
Battery almost discharged. The battery should be replaced
promptly.
Battery is discharged. The battery must be replaced for further
use.
To replace the battery, first switch off the meter and remove the earthing cable from the meter.
Then open the battery compartment and replace the battery with a new 9 V block battery. Then
close the battery compartment. The measurement can be resumed.

© PCE Instruments
7
6 Switching on and off
To switch the meter on and off, press the on/off switch. The measurement is made after a few
seconds. To switch the meter off again, press the on/off switch again.
7 Backlight
When the meter is switched on, the backlight is activated. To switch off the backlight, press and
hold the "ECO" key for two seconds. To switch the backlight back on, press and hold the "ECO"
key again for two seconds.
8 Making a measurement
To make a measurement, first connect the earthing cable to the meter and to an earthed
conductor. Then switch on the meter. The measurement will start after a short time. Point the
measuring device at the object to be measured. You have reached the correct distance as soon
as the lasers cross. Now you can read the measured value.
9 Zeroing
To zero the meter, first ground it with the earthing cable. Then switch on the meter and wait until
the reading has stabilised. Then press the zero key to set the displayed reading to zero.
NOTE:
Make sure that there is no static charge on the sensor side. This can influence zeroing.

10 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact
us. You will find the relevant contact information at the end of this user manual.
11 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European
Parliament applies. Due to the contained pollutants, batteries must not be disposed of as
household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either reuse them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance
with your local waste regulations.
If you have any questions, please contact PCE Instruments.
© PCE Instruments
8

© PCE Instruments
9
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L.
Im Langel 26 23, rue de Strasbourg Calle Mayor, 53
D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete)
Deutschland France España
Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548
Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542
info@pce-instruments.com info@pce-france.fr info@pce-iberica.es
www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti.
Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah.
Ensign Way, Southampton 55010 Loc. Gragnano Pehlivan Sok. No.6/C
Hampshire Capannori (Lucca) 34303 Küçükçekmece - İstanbul
United Kingdom, SO31 4RF Italia Türkiye
Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47
Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93
info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr
www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America
PCE Brookhuis B.V. PCE Americas Inc.
Institutenweg 15 1201 Jupiter Park Drive, Suite 8
7521 PH Enschede Jupiter / Palm Beach
Nederland 33458 FL
Telefoon: +31 (0)53 737 01 92 USA
info@pcebenelux.nl Tel: +1 (561) 320-9162
www.pce-instruments.com/dutch Fax: +1 (561) 320-9176
info@pce-americas.com