Contents
1 Safety notes ........................................................................................... 1
2 Specifications ........................................................................................ 2
3 Delivery scope ....................................................................................... 2
4 Device description ................................................................................ 3
5 Display description ............................................................................... 4
6 Switching the meter on and off ........................................................... 4
7 Set units ................................................................................................. 4
8 MIN / MAX / normal measuring mode.................................................. 5
9 Insert or replace battery ....................................................................... 5
10 Contact ................................................................................................. 5
11 Disposal ................................................................................................. 5
© PCE Instruments
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business. If you have any questions please contact PCE Instruments. The contact details can be found at
the end of this manual.
Page 4
© PCE Instruments
2
2 Specifications
Temperature
Measurement range
-10 ... 50 °C / 14 ... 122 °F
Resolution
0.1 °C / 32.18 °F
Measurement accuracy
±1.0 °C / 33.8 °F
Humidity
Measurement range
20 ... 90 % RH
Resolution
1 % RH
Measurement accuracy
±15 % RH
Further specifications
Units
°C, °F
Functions
Normal measuring mode, MIN / MAX
Measurement rate
1 value every seconds 10
Power supply
1.5 V, LR44, battery
Power consumption
<10 µA
Operating conditions
-10 ... 50 °C / 14 ... 122 °F, <90 % RH, non-condensing
Storage conditions
-10 ... 60 °C / 14 ... 140 °F, <90 % RH, non-condensing
Dimensions
138 x 27 x 19 mm / 5.4 x 1.0 x 0.7"
Weight
40 g / 1.4 oz
3 Delivery scope
1 x thermo-hygrometer PCE-PTH 10 1 x 1.5 V LR44 battery 1 x user manual
Page 5
© PCE Instruments
3
4 Device description
Front view
Rear view
No.
Description
1
Temperature and humidity sensor
2
Display
3
Unit key to select between °C and °F
4
MIN / MAX key to display the highest and lowest measured value
5
Battery compartment and retaining clip
6
On and off switch
Page 6
© PCE Instruments
4
5 Display description
No.
Description
1
Temperature reading
2
Humidity reading
Display
Description
RH
Relative humidity
%
Unit for relative humidity
MAX
The values displayed are the highest measured values
MIN
The values displayed are the lowest measured values
°C
Unit for degrees Celsius
°F
Unit for degrees Fahrenheit
6 Switching the meter on and off
To turn the meter on and off, press the switch on the back of the meter.
7 Set units
To select between the units °C and °F, press the unit key.
Page 7
8 MIN / MAX / normal measuring mode
After switching on the meter, the measurement is recorded directly. At the same time, the highest and lowest measured values are saved in the background. To see these values, repeatedly press the "MIN / MAX" key on the meter until "MAX" is displayed for the highest measured value or "MIN" for the lowest measured value. If nothing is displayed, you are in normal measuring mode.
Note:
If no entry is made, the meter automatically switches back to normal measuring mode after 8 seconds. As soon as the meter is switched off, the memory is cleared.
9 Insert or replace battery
To insert or replace the battery, first switch off the meter. Open the battery compartment on the back with a Phillips screwdriver. Now insert a 1.5 V LR44 battery into the meter. Make sure that the polarity is correct when inserting the battery. Then close the battery compartment. The meter is ready for use again.
10 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact
us. You will find the relevant contact information at the end of this user manual.
11 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re­use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
© PCE Instruments
5
Page 8
© PCE Instruments
6
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Ensign Way, Southampton 55010 Loc. Gragnano Pehlivan Sok. No.6/C Hampshire Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom, SO31 4RF Italia Türkiye Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America
PCE Brookhuis B.V. PCE Americas Inc. Institutenweg 15 1201 Jupiter Park Drive, Suite 8 7521 PH Enschede Jupiter / Palm Beach Nederland 33458 FL Telefoon: +31 (0)53 737 01 92 USA info@pcebenelux.nl Tel: +1 (561) 320-9162 www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 info@pce-americas.com www.pce-instruments.com/us
Loading...