Please read this manual before switching the unit on.
Important safety information inside.
Page 2
Contents Page
1. Introduction
2. Features
3. Front Panel and Bottom Description
4. Specifications
5. Power on or Power off
6. Measurement Mode
7. Setup mode
8. Shortcut keys
9. Product Maintenance
10. Cautions
...........................................
................................................
.........................................
..............................
.................................
...........................................
7-1. Date/Time setup 7-2. Alarm setup 7-3. Sample Time 7-4. Unit(°C/°F)setup 7-5. Memory View 7-6. Mass/Particle setup 7-7. Auto Power Off setup
.......................................
............................................
...........................................
......................................
..........................................
.................................
.........................................
................................
..............................................
...............................
..............
4 4 5 6 7 7 8 8 8 9 9 9 10 10 11 11 11
Page 3
1. Introduction
Thank you for purchasing this Mini Par ticle Counter P C E - M P C 10. The PCE-MPC 10 with 2.0 color TFT LCD display provides fast, easy and accurate readings for par ticle counter, par ticle mass concentration, Air temperature and relative humid ity. The series pro ducts i s a delica te a nd pract ical hand-held instrument, the real scene and time can b e displayed on color TFT LCD. memory readings can be recorded in me ter. It Wo uld be
Any
the best instr ument for environment protection and energy save.
"
2. Features
2.0 TFT Color LCD display
"
220*176 pixels
Simultaneously measure PM2.5 and Pm10
Air temperature and humidity
Real time clock display
Analog bar indicator
Auto Power
Page 4
3. Front Panel and Bottom Description
1-Particle Sensor 2-LCD Display 3-Page up and Setup button 4-Page down and ESC button 5-Power ON/OFF button 6-Measure and Enter button 7-Memory View button 8-USB charge interface 9-Air-bleed hole 10-Bracket fixing hole
1
2
3
5
6
8
4
7
9
10
Page 5
4. Specications
Particle Counter PCE-MPC 10 Channel Mass Concentration
Resolution Air Temperature Measure Air Temp Range Resolution Basic Accuracy Humidity Range Resolution Basic Accuracy
2.5um, 10um PM2.5: 0~2000ug/m PM10: 0~2000ug/m 1ug/m
0 ~ 50°C/32~122°F
0.1°C/°F ±1°C/2°F 0 to 100%RH
0.1%RH ±5%RH
±3.5%RH
3
3
3
0 ~ 20%RH 80~100%RH 20~80%RH
Page 6
5. Power on or Power off
On the power off mode, press and hold button, until the LCD is on,
then the unit will power on.
On the power on mode, press and hold button, until the LCD is off,
then the unit will power off.
6. Measurement Mode
On the p ower o n mode, you can press the button to start measuring PM2.5 and PM10, the top left corner of the LCD display “Counting”, the top right corner of the LCD display count down, LCD maindisplay PM2.5 and PM10 data and temperature & humidity readings are at the bottom of LCD.
Press the button again to stop the measurement, the top left corner of the LCD display “Stopped”, The LCD display the last measurement data. Data will be automatically saved to the instrument memory, which canstore up to 5000 data.
2015-10-08 16:24
Counting wait5
size
2.5um 0 1 0um 0
o
AT C RH %33.4 45.2
ug/m
3
2015-10-08 16:24
Stopped
size
2.5um 28 1 0um 58
o
AT C RH %33.4 42.8
ug/m
3
Page 7
7. Setup mode
Powering on the instrument, Long press button to enter into the system setup mode when not do measurement operation, as shown below:
2015-10-08 16:24
System Set
Date/Time
Alarm Set
Sample Mode
oo
Unit( C/ F)
Memory View
Mass/Particle
Auto Power off
Press the button and the button to select the menu option needed, then press button to enter into the appropriate settings page.
7-1.Date/Time setup
After entering into Date/Time setup mode, press button and
button to select the value, press button to set next value. After finished the setup, please press button to exit time setting mode and returns to the system settings mode.
2015-10-08 16:24
Date Set
Date 2015-10-08
24Hour 16:24
7-2.Alarm setup
Press button and button to activat e or deactivate alarm
function.
2015-10-08 16:24
Alarm Set
ON
OFF
Page 8
7-3.Sample Time
Press button and thes button to select the sampling time,
sampling time can be select by 30s,1min,2min or 5min.
2015-10-08 16:24
Sample Time
30S
1Min
2Min
5Min
7-4.Unit(°C/°F)setup
Press button and the button to select the temperature unit
(°C/°F).
2015-10-08 16:24
Unit Set
o
C
o
F
7-5.Memory View
Press button and button to select storage catalog, press
button to view data in selected storage catalog.
5000 sets of data can be stored in the instrument.
2015-10-08 16:37
Memory View
00001
2015-10-08 16:26
2015-10-08 16:2
2015-10-08 16:2
2015-10-08 16:2
2015-10-08 16:2
2015-10-08 16:
2015-10-08 16:
7
8
9
9
30
31
Page 9
7-6.Mass/Particle setup
Press button and the but ton to se lect the mod e par ticle
concentration and mass concentration mode.
2015-10-08 16:25
Mass/particle
Mass
Particle
7-7.Auto Power Off setup
Press button and button to set the auto-off time. Disable: Power off function is deactivated. 3MIN: Automatically shutdown in 3 minutes without any operations. 10MIN: Automatically shutdown in 10 minutes without any operations. 30MIN: Automatically shutdown in 30 minutes without any o
2015-10-08 16:25
Auto Pow off
Disable
3MIN
10MIN
30MIN
perations.
Page 10
8. Shortcut keys
Press the button to quickly enter the storage data directory view,
select the directory button to view the specific data.
In the main LCD interface, pressing and hold the button then press
the button until the sound of a buzzer delete the stored data.
9. Product Maintenance
Maintenance or service is not included in this manual, the product must
be repaired by professionals
It must use the required replacement parts in maintenance
If the operating manual is changed, please instruments prevail without
notice
10. Cautions
Do not use in over dir ty or dusty environment. Inhalation of too many
particles will damage the product.
To ensure the measure accuracy, please do not use in an over fogged
environment.
Do not use in explosive environment.
Follow the instructions to use the product, privately take apart the unit
is not allowed.
Page 11
Rev.160421