INDEX
1. INTRODUCTION.............................
2. SAFETY NOTES.............................
3. FEATURES.....................................
4. SPECIFICATIONS..........................
5. GENERAL.......................................
6. INSTRUMENT LAYOUT..................
7. MEASUREMENT.............................
8. MAINTENANCE..............................
9.
INTERFACE
CONNECTION
AND
OPERATION.............................
10. Contact..........................................
11. Disposal.........................................
PAGE
1
2
3
4
5
6-7
8-12
13

NOTE
This meter has been designed and tested According
to CE Safety Requirements for Electronic Measuring
Apparatus, IEC / EN 61010-1 and other safety
standards. Follow all warnings to ensure safe
operation.
WARNING
READ "SAFETY NOTES" (NEXT PAGE) BEFORE
USING THE METER.
Is for measurements performed at the
source of the low-voltage installation.
Is for measurements performed in the
building Installation.
Is for measurements performed on circuits
directly connected to the low-voltage
installation.

2. SAFETY NOTES
● Read the following safety information carefully
Before attempting to operate or service the meter.
● Use the meter only as specified in this manual.
Otherwise, the protection provided by the meter
may be impaired.
● Rated environmental conditions :
(1) Indoor Use.
(2) Installation Category III.
(2) Pollution Degree 2.
(3) Altitude up to 2000 meters.
(4) Relative humidity 80% max.
(5) Ambient temperature 0~40°C.
● Observe the International Electrical Symbols listed
below :
Meter is protected throughout by double
insulation or reinforced insulation.
Warning ! Risk of electric shock.
Caution ! Refer to this manual before using
the meter.

3. FEATURES
● Maximum testing current of 10A
● Ranges:
200.0μΩ / 2000μΩ
20.00mΩ / 200.0mΩ
2.000Ω / 20.00Ω
200.0Ω
● Maximum resolution of 0.1μΩ at 10A
● Four terminal measurement
● 4 Lines × 20 Characters LCD
● Optical USB to RS-232 data transmission
● Well isolated from contact
● 2 built-in optical LEDs for data transfer
● Memory function (200 measurement results)
● Auto power off
● Low battery indication
● Power source:
Rechargeable battery DC14.8V 5200mAh 76.96Wh
● Safety Standard:
IEC/EN 61010-1 CAT III 300V
EN 61326-1

4. SPECIFICATIONS
4-wire method measurement
Measuring ranges
/ resolution
200.0μΩ / 0.1μΩ
2000μΩ / 1μΩ
20.00mΩ / 0.01mΩ
200.0mΩ / 0.1mΩ
2.000Ω / 1mΩ
20.00Ω / 0.01Ω
200.0Ω / 0.1Ω
200.0μΩ ~ 2000μΩ: ±(2% + 8dgt)
20.00mΩ ~ 200.0Ω: ±(1% + 4dgt)
10A: 200.0μΩ / 2000μΩ
1A: 20.00mΩ / 200.0mΩ
100mA: 2.000Ω / 20.00Ω
10mA: 200.0Ω

5. GENERAL
● Operating temperature: 0~40°C.
● Operating humidity: 80% RH.
● Dimensions:
322(L) × 260(W) × 135(D)mm
● Weight:
Approx. 3137g (battery included)
● Power source:
Rechargeable battery DC14.8V 5200mAh 79.69Wh
● Accessories:
Instruction manual
Test leads
Data transmission cable
Software for PC interface
Shoulder belt
Charger
● Safety Standard:
IEC/EN 61010-1 CAT III 300V
EN 61326-1

Optical Adapter for
Data Transmission
-6- (1) 4 Lines × 20 characters LCD

(2) 10A Button
(3) 1A Button
(4) 100mA Button
(5) 10mA Button
(6) ▲ Button
(7) ▼ Button
(8) ESC / SEL Button
(9) ENTER / SAVE Button
(10) ON / OFF Button
(11) TEST / STOP Button
(12) C1 Terminal
(13) P1 Terminal
(14) P2 Terminal
(15) C2 Terminal
(16) Charge LED
(17) Charge Socket
(18) Optical Adapter for
Data Transmission

7. MEASUREMENT
1. Power On :
Press "ON/OFF" button to turn the power on or off.
Hold the "ON/OFF" button that can display the
voltage of battery.
The system will be auto off when it has no operation
after 3 minutes.
2.Before testing, you must make sure that the
resistance under test does not have any voltage.
When the voltage exceeds approx. 5 volts or the
probe is connected to a power supply of more
than approx. 5 volts,a warning message will be
displayed.
3.Select test current & scale range :
There are 4 buttons "10mA", "100mA", "1A" and
"10A" which can choose the operation current and
the scale range.
"10mA" button for 200.0 Ω only.
"100mA" button can choose 20.00 Ω & 2.000 Ω.
"1A" button can choose 200.0 mΩ & 20.00 mΩ.
"10A" button can choose 2000μΩ & 200.0μΩ.
The screen will display date, time, test current and
maximum resistance.
-8-

4.The measurement function
Press "TEST/STOP" button to measure the
resistance value.
It needs a few seconds to complete the
measurement, so press "TEST/STOP" button again
that can interrupt the measurement.
4-wire method
C
1 P1 CAT III 300V P2 C2
When the measurement is finished, the screen will
display the resistance value and testing current.

5.Record saving function
When the measurement is finished, press
"SAVE/ENTER" button to save the result of
measurement.
At the same time, the last line will display the
number of records.
The memory can record up to 200 records.
6.Minor function
Press "ESC/SEL" button and hold over 1 second to
enter the minor function.
Use the "UP" and "DOWN" button to move the
function selection cursor, and press "SAVE/ENTER"
to enter the minor function, and press "ESC/SEL"
button to return back to the main page.
● Date/Time ADJ

Press "ESC/SEL" button to leave the Date/Time
ADJ.
Press "UP" or "DOWN" button to set the correct
number.
Press "TEST/STOP" button to switch to the next
unit of date or time and go on the required
adjustment.
After all adjustments are completed, press "SAVE/
ENTER" button to confirm and save the date and
time.
Press "ESC/SEL" button to return back to the
minor function menu.
● RECORD DISPLAY
Press "UP" or "DOWN" button to reach the record
that you want to look up.
Press "ESC/SEL" button to return back to the
minor function menu.

Press "SAVE/ENTER" button to clear all records
in the memory.
Press "ESC/SEL" button to return back to the
minor function menu.
REMEMBER TO CHARGE THE BATTERY!
ALWAYS recharge the battery when the Low
Battery info appears on the display. Leaving
the battery uncharged for a long period of
time may affect the lifespan of the battery.

8. MAINTENANCE
Charge:
When low battery warning information "LoBAT"
appears, please charge the battery.
1. Plug one end of charger into the charge socket
and the other end into the ACV power socket.
2. If ACV plug socket is energized, the charge
LED is lit on indicating that charge is underway.
If the ACV plug socket isn’t energized, remove
to another power-energized one making power
charge.
3. After the voltage reaches approx. 16.0V~16.5V,
charge process is complete.
(It can be observed on LCD display.)
No measurement can be performed during the
charging process.

9. INTERFACE CONNECTION AND OPERATION
(A) Microohm Meter Setup Installation:
1. Install the "Micoohm Setup" on the personal
computer.
2. Click the "Next" button.
3. To install into a different folder, click Browse
and Select another folder. If it's not necessary,
click the "Next" button.

4. Click the "Next" button.
5. All the files are installing to your personal
computer.

6. The Microohm Meter program has been
successfully installed and then click "Finish"
button.
7. The software driver file:
"CDM 2.08.24 WHQL Certified x64-64bit" and
"CDM 2.08.24 WHQL Certified x86-32bit" files.
(Note: New Windows system will install the
software driver automatically. It's
necessary to install the software driver
only if it is the old windows system)

(B) Windows Comm Port setting:
1. Plug CA-232 data transmission cable into the
personal computer USB port.
2. On the windows system, right click the
"This PC" icon to find manager.
3. Click the "Device Manager" to find ports
(COM & LPT).
Ports(COM & LPT)
②Click "Device Manger"

4. Click the Ports (COM & LPT) to find USB
Serial Port (COM6).
(Note: USB Serial Port will indicate
automatically different "COM" port)
③Click Ports(COM &LPT) USB Serial Port(COM6)

(C) Microohm Meter Software Comm Ports
Setting:
1. Connect CA-232 data transmission cable to
the Insulation Tester.
2. Click the "Microohm Meter" icon to the
personal computer.
3. On the Microohm Meter windows, select the
correct "Comm Port" and click the "connect
button".
①Comm Ports Selection
②Click connect button

4. The Comm Port selection is workable when
the red signal turns green signal.
5. Click the "Download Log from Device" button
can show the data.
①Click the Download
Log from Device

6. Click the "Save Log" button to save the data
records to the personal computer.
Microohm Meter Windows Interface
Introduction:

Periodically wipe the case with a damp cloth and
detergent. Do not use abrasives or solvents.
Due to our policy of constant improvement and development, we
reserve the right to change specifications without notice.
WARNING
To avoid electrical shock or damage to the
instrument, do not get water inside the case.

10 Contact
If you have any questions, suggestions or technical
problems, please do not hesitate to contact us. You will
find the relevant contact information at the end of this
user manual.
11 Disposal
For the disposal of batteries in the EU, the 2006/66/EC
directive of the European Parliament applies. Due to the
contained pollutants, batteries must not be disposed of
as household waste. They must be given to collection
points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we
take our devices back. We either re-use them or give
them to a recycling company which disposes of the
devices in line with law.
For countries outside the EU, batteries and devices
should be disposed of in accordance with your local
waste regulations.
If you have any questions, please contact PCE
Instruments.
Pb
Pb
Cd
Hg
www.pce-instruments.com

PCE Instruments contact information
Germany
PCE Deutschland GmbH
Im Langel 26
D-59872 Meschede
Deutschland
Tel.: +49 (0) 2903 976 99 0
Fax: +49 (0) 2903 976 99 29
info@pce-instruments.com
www.pce-instruments.com/deutsch
France
PCE Instruments France EURL
23, rue de Strasbourg
67250 Soultz -Sous -Forets
France
Téléphone: +33 (0) 972 3537 17
Numéro de fax: +33 (0) 972 3537 18
info@pce -france.fr
www.pce -instruments.com/french
Spain
PCE Ibérica S.L.
Calle Mula, 8
02500 Tobarra (Albacete)
España
Tel. : +34 967 543 548
Fax: +34 967 543 542
info@pce-iberica.es
www.pce-instruments.com/espanol
United Kingdom
PCE Instruments UK Ltd
Trafford House
Chester Rd, Old Trafford
Manchester M32 0RS
United Kingdom
Tel: +44 (0) 161 464902 0
Fax: +44 (0) 161 464902 9
info@pce-instruments.co.uk
www.pce-instruments.com/english
Italy
PCE Italia s.r.l.
Via Pesciatina 878 / B -Interno 6
55010 Loc. Gragnano
Capannori (Lucca)
Italia
Telefono: +39 0583 975 114
Fax: +39 0583 974 824
info@pce -italia.it
www.pce -instruments.com/italiano
Turkey
PCE Teknik Cihazları Ltd.Şti.
Halkalı Merkez Mah.
Pehlivan Sok. No.6/C
34303 Küçükçekmece - İstanbul
Türkiye
Tel: 0212 471 11 47
Faks: 0212 705 53 93
info@pce-cihazlari.com.tr
www.pce-instruments.com/turkish
The Netherlands
PCE Brookhuis B.V.
Institutenweg 15
7521 PH Enschede
Nederland
Telefoon: +31 (0)53 737 01 92
info@pcebenelux.nl
www.pce-instruments.com/dutch
United States of America Denmark
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter / Palm Beach
33458 FL
USA
Tel: +1 (561) 320-9162
Fax: +1 (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/us
PCE Instruments Denmark ApS Birk
Centerpark 40
7400 Herning
Denmark
Tel.: +45 70 30 53 08
kontakt@pceinstruments.com
www.pce-instruments.com/dansk