PCE-MIR 20 Infrared Thermometer
User Manual
Last change: 22 January 2024
v1.0
English
Page 2
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Specifications ........................................................................................ 2
3 Delivery scope ....................................................................................... 2
4 Device description ................................................................................ 3
4.1 Display description ........................................................................................................... 3
5 Making a measurement ........................................................................ 4
5.1 Measuring spot ratio ......................................................................................................... 4
5.2 Highest, lowest, average and difference value.................................................................. 4
6 Settings .................................................................................................. 5
6.1 Set emissivity ................................................................................................................... 5
6.2 Set unit ............................................................................................................................. 5
6.3 Limit value setting: highest measured value - switch alarm on and off .............................. 5
6.4 Limit value setting: highest measured value - limit value setting ....................................... 5
6.5 Limit value setting: lowest measured value - switch alarm on and off ............................... 5
6.6 Limit value setting: lowest measured value - limit value setting......................................... 5
7 Laser pointer ......................................................................................... 6
8 Replace / insert battery ........................................................................ 6
9 Contact ................................................................................................... 7
10 Disposal ................................................................................................. 7
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to the user.
Never point the laser beam at people or animals.
Never look directly into the laser beam.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business.
Page 4
© PCE Instruments
2
2 Specifications
Measurement range
-50 ... 760 °C / -58 ... 1400 °F
Resolution
0.1 °C / 0.1 °F
Accuracy
±3 °C / 5.4 °F at -50 ... +20 °C / -58 ... +68 °F ±2 % ±2 °C / 3.6 °F at 20 ... 760 °C / 68 ... 1400 °F
Repeatability
±1 °C / ±1.8 °F
Measuring spot ratio
12:1
Emissivity
0.10 ... 1.00
Measuring rate
2 Hz
Spectral range
8 ... 14 µm
Overload indication
" - - - - "
Laser
Output power: <1 mW Wavelength: 630 ... 670 mm; Laser class: 2
Power supply
9 V block battery
Operating conditions
0 ... 50 °C / 32 ... 122 °F, <90 % RH
Storage conditions
-10 ... 60 °C / 14 ... 140 °F, <80 % RH
Dimensions
175 x 75 x 35 mm
Weight
114 g (without battery)
3 Delivery scope
1 x PCE-MIR 20 infrared thermometer 1 x transport bag 1 x 9 V block battery 1 x user manual
Page 5
© PCE Instruments
3
4 Device description
No.
Description of the
1
Laser pointer
2
Infrared sensor
3
Display
4
arrow up key / switching the laser pointer on and off
5
arrow down key
6
MODE key
7
Key for switching on the meter and starting the measurement
8
Battery compartment cover
4.1 Display description
No.
Description
1
SCAN display: measurement is active
2
Displayed measured value is frozen
3
Laser pointer is active
4
Display when limit value is exceeded
5
Temperature unit
6
Battery status display
7
Set emissivity
8
Display of the highest, lowest, average measured value or difference
9
Measured value
Page 6
© PCE Instruments
4
5 Making a measurement
To carry out a measurement, press and hold the switch-on key. The measuring device switches on and makes a measurement. Release the key to interrupt the measurement. To switch off the meter, wait 10 seconds. The measuring device switches itself off.
5.1 Measuring spot ratio
The measuring spot ratio must be observed during the measurement. The measuring spot ratio is 12:1, which means that the size of the measuring spot is 1/12 of the distance of the measuring surface. The measured value is the average of the measuring spot.
5.2 Highest, lowest, average and difference value
The following values are shown at the bottom of the display: maximum (MAX), minimum (MIN), average (AVG) and difference (DIF). To switch between the maximum, minimum, average and difference values, press and release the MODE key once until the desired function is reached.
Note The function is reset with every new measurement.
Page 7
© PCE Instruments
5
6 Settings
To make settings, press and hold the MODE key for two seconds. The settings are applied immediately.
6.1 Set emissivity
To set the emissivity, go to the settings. The emissivity is set in the first menu item. This can be recognised by the flashing ε icon on the display. The emissivity can be set using the arrow keys.
6.2 Set unit
Press and release the MODE key to set the temperature unit. The currently set temperature unit flashes on the display. The temperature unit can be set using the arrow keys. You can choose between °C and °F.
6.3 Limit value setting: highest measured value - switch alarm on and off
Press and release the MODE key. The alarm for the highest measured value can now be switched on and off. Use the arrow keys to switch the alarm on and off. On = alarm is switched on, OFF = alarm is switched off
6.4 Limit value setting: highest measured value - limit value setting
Press and release the MODE key. Once the alarm has been activated, the limit value can be set. The temperature value can be set using the arrow keys.
6.5 Limit value setting: lowest measured value - switch alarm on and off
Press and release the MODE key. The alarm for the lowest measured value can now be switched on and off. Use the arrow keys to switch the alarm on and off. On = alarm is switched on, OFF = alarm is switched off
6.6 Limit value setting: lowest measured value - limit value setting
Press and release the MODE key. Once the alarm has been activated, the limit value can be set. The temperature value can be set using the arrow keys.
Press and release the MODE key to exit the settings.
Page 8
© PCE Instruments
6
7 Laser pointer
To switch the laser pointer on and off for better orientation, press and release the key once.
8 Replace / insert battery
To insert the battery or replace it if necessary, open the battery compartment. Now insert a 9 V block battery. Ensure that the polarity is correct.
Note If the battery indicator appears on the display, the battery is discharged and must
be replaced to ensure proper function.
Page 9
© PCE Instruments
7
9 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
10 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 10
© PCE Instruments
8
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mula, 8 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Trafford House Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Chester Rd, Old Trafford 55010 Loc. Gragnano Pehlivan Sok. No.6/C Manchester M32 0RS Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom Italia Türkiye Tel: +44 (0) 161 464902 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 161 464902 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America Denmark
PCE Brookhuis B.V. PCE Americas Inc. PCE Instruments Denmark ApS Institutenweg 15 1201 Jupiter Park Drive, Suite 8 Birk Centerpark 40 7521 PH Enschede Jupiter / Palm Beach 7400 Herning Nederland 33458 FL Denmark Telefoon: +31 (0)53 737 01 92 USA Tel.: +45 70 30 53 08 info@pcebenelux.nl Tel: +1 (561) 320-9162 kontakt@pce-instruments.com www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 www.pce-instruments.com/dansk info@pce-americas.com www.pce-instruments.com/us
Loading...