PCE Instruments PCE-MIR 10 Users guide

Page 1
© PCE Instruments
PCE-MIR 10 Infrared Thermometer
User Manual
Last change: 6 May 2024
v1.0
English
Page 2
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Technical specifications ...................................................................... 2
3 Delivery contents .................................................................................. 2
4 Device description ................................................................................ 3
4.1 Display description ........................................................................................................... 3
5 Making a measurement ........................................................................ 4
5.1 Distance-to-target-ratio ..................................................................................................... 4
6 Setting the temperature unit ................................................................ 4
7 Highest and lowest measured value ................................................... 4
8 Backlight ................................................................................................ 4
9 Laser pointer ......................................................................................... 4
10 Replacing / insertig the battery ........................................................... 5
11 Contact ................................................................................................... 6
12 Disposal ................................................................................................. 6
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to the user.
Never point the laser at persons or animals.
Never look into the laser beam directly-
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business.
Page 4
© PCE Instruments
2
2 Technical specifications
3 Delivery contents
1 x PCE-MIR 10 1 x carrying bag 1 x 9 V block battery 1 x user manual
Model
PCE-MIR 10
Measurement range
-50 … 500 °C / -58 … 932 °F
Reslution
0.1 °C / 0.1 °F
Accuracy
±3 °C / 5.4 °F at -50 … +20 °C / -58 … +68 °F
±2 % ±2 °C / 3.6 °F at 20 … 500 °C / 68 … 932 °F
Repeatability
±1 °C / ±1.8 °F
Distance-to-target-ratio
12:1
Emissivity
0.95 fixed
Measurement rate
2 Hz
Spectral range
8 … 14 µm
Overload indication
- - - -
Laser
output power: <1 mW wavelength: 630 … 670 mm; laser class: 2
Power supply
9 V block battery
Operating conditions
0 … 50 °C / 32 … 122 °F, <90 % RH
Storage conditions
-10 … 60 °C / 14 … 140 °F, <80 % RH
Dimensions
175 x 75 x 35 mm
Weight
132 g
Page 5
© PCE Instruments
3
4 Device description
No.
Description
1
Laser pointer
2
Infrared sensor
3
Display
4
°C / °F key to set temperature unit
5
Key to (de)activate backlight and laser pointer
6
MAX / MIN key to display highest and lowest measured value
7
Power key to witch on meter and to start the measurement
8
Battery compartment cover
4.1 Display description
No.
Description
1
SCAN: ongoing measurement
2
Measured value
3
Displayed temperature is the highest or lowest measured
4
Displayed reading is held
5
Laser pointer is active
6
Sound function not available
7
Battery status display
8
Temperature unit
Page 6
© PCE Instruments
4
5 Making a measurement
To carry out a measurement, press and hold the power key during the measurement. The meter switches on. Release the key to interrupt the measurement. To switch the meter off, wait 10 seconds. The device switches itself off.
5.1 Distance-to-target-ratio
The distance-to-target-ratio must be observed during the measurement. The distance-to-target­ratio is 12:1, which means that the size of the measuring spot is 1/12 of the distance of the measuring surface. The measured value is the average of the measuring spot.
6 Setting the temperature unit
To set the temperature unit, press the °C/°F key. The display will change immediately. You can choose between °C and °F.
7 Highest and lowest measured value
The highest and the lowest measured value are shown at the bottom of the display. To select between the highest and lowest values, press the MAX/MIN key. The display changes immediately. Note: The highest and lowest measured value are reset whenever a new measurement is started. This function cannot be deactivated.
8 Backlight
To (de)activate the backlight, press and release the key.
9 Laser pointer
To activate the laser pointer for better orientation or to deactivate it, press and hold the key for several seconds.
Page 7
© PCE Instruments
5
10 Replacing / insertig the battery
To insert or replace the battery, open the battery compartment. Now insert a 9 V block battery. Ensure that the polarity is correct. Note: If the battery indicator appears on the display, the battery is flat and must be replaced to ensure proper function.
Page 8
© PCE Instruments
6
11 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
12 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 9
© PCE Instruments
7
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mula, 8 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Trafford House Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Chester Rd, Old Trafford 55010 Loc. Gragnano Pehlivan Sok. No.6/C Manchester M32 0RS Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom Italia Türkiye Tel: +44 (0) 161 464902 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 161 464902 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America Denmark
PCE Brookhuis B.V. PCE Americas Inc. PCE Instruments Denmark ApS Institutenweg 15 1201 Jupiter Park Drive, Suite 8 Birk Centerpark 40 7521 PH Enschede Jupiter / Palm Beach 7400 Herning Nederland 33458 FL Denmark Telefoon: +31 (0)53 737 01 92 USA Tel.: +45 70 30 53 08 info@pcebenelux.nl Tel: +1 (561) 320-9162 kontakt@pce-instruments.com www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 www.pce-instruments.com/dansk info@pce-americas.com www.pce-instruments.com/us
Loading...