PCE Instruments PCE-MCM 10, PCE-MCM 10-ICA Users guide

Page 1
© PCE Instruments
PCE-MCM 10 Clamp Meter
User Manual
Last change: 7 June 2023
v1.0
English
Page 2
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Specifications ........................................................................................ 2
3 Delivery scope ....................................................................................... 2
4 Device description ................................................................................ 3
4.1 Display description ........................................................................................................... 4
4.2 Icons ................................................................................................................................ 4
5 Switching the meter on and off ........................................................... 5
5.1 Automatic power off.......................................................................................................... 5
6 Making a measurement ........................................................................ 5
6.1 Carry out zeroing .............................................................................................................. 5
6.2 Freeze measured value .................................................................................................... 6
7 Torch ...................................................................................................... 6
8 Replace / insert batteries ..................................................................... 6
9 Contact ................................................................................................... 7
10 Disposal ................................................................................................. 7
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to the user.
Never touch live components when measuring. There is a danger to life.
Before replacing the batteries or the fuses, all test leads must be removed from the
meter.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business.
Page 4
© PCE Instruments
2
2 Specifications
Measurement range 1
±20.99 mA DC
Resolution
0.01 mA
Accuracy
±0.3 % of rdg. +8 digits
Measurement range 2
±21.0 ... ±99.9 mA DC
Resolution
0.1 mA
Accuracy
±1 % of rdg. + 8 digits
Influence of the earth's magnetic field on the measured value
max. 0.25 mA DC Current clamp aperture
5 mm
Automatic power off
after 10 minutes (can be deactivated)
Operating voltage
3 V via 2 AA batteries
Battery life
approx. 40 hours
Protection class
IP40
Overvoltage category
CAT II 300 V
Operating conditions
-10 ... +50 °C / 14 ... 122 °F
Storage conditions
-15 ... +60 °C / / 5 ... 140 °F
Environmental humidity
<90 % RH at <30 °C / 86 °F <75 % RH at 30 ... 50 °C / 86 ... 122 °F
Working height
0 ... 2000 m above sea level
Dimensions
handheld: 180 x 55 x 39 mm / 7.1 x 2.2 x 1.5 in current clamp: 90 x 40 x 1.5 mm / 3.5 x 1.6 x 0.06 in cable length: approx. 1 m / 3.3 ft
Weight
268 g / 0.6 lbs with batteries inserted
3 Delivery scope
1 x PCE-MCM 10 1 x transport bag 2 x 1.5 V AA battery 1 x user manual
Page 5
© PCE Instruments
3
4 Device description
No.
Description
1
Current clamp
2
Current clamp compartment / removed current clamp
3
On and off key
4
On/off key for automatic power off
5
On and off key for the torch
6
Freeze measured value (HOLD)
7
Zero display
8
LC display
9
Torch
10
Battery compartment
Page 6
© PCE Instruments
4
4.1 Display description
The lower part of the display shows the current measured value. The upper part of the display shows the measured value scaled as a percentage. The scaling values can be taken from the following chart.
Measured value
Percentage display
0 mA
-25.0 %
2 mA
-12.5 %
3.2 mA
-5.0 %
3.6 mA
-2.5 %
4 mA
0 %
8 mA
25.0 %
12 mA
50.0 %
16 mA
75.0 %
20 mA
100.0 %
Formula: displayed percentage = 6.25 x measured value - 25
4.2 Icons
Icon
Description
Keep away from dangerous live wires
Important information
Risk of electric shock
Meter insulated according to class 2
Batteries
Direct current
Page 7
© PCE Instruments
5
5 Switching the meter on and off
To switch the meter on, press and hold the on/off key for three seconds. To switch the meter off again, press and hold the key again for three seconds.
5.1 Automatic power off
If the automatic power off function is active, the meter switches itself off within 10 minutes. To deactivate automatic power off, press and hold the key for two seconds. To reactivate
automatic power off, press and hold the key again.
Note: After restarting the meter, automatic power off is reactivated.
6 Making a measurement
To make a measurement, remove the measuring clamp from the meter and unwind the cable completely. Clamp the current clamp around the cable to be measured. Pay attention to the direction of current flow. This is marked on the current clamp. Only one cable must be in the current clamp at a time. If there are more than one, the measured values may be incorrect. The measured value is displayed directly.
Important: No measurement must be carried out on uninsulated lines.
6.1 Carry out zeroing
Before the measurement is made, the measured value should be zeroed to prevent an incorrect measured value from being displayed. The cable should not be connected during this. To perform zeroing, press and hold the "ZERO" key for two seconds until "ZERO" lights up once briefly on the display. The measured value is now zeroed Note: Zeroing does not increase the measurement range. When zeroing, the current clamp must not be wrapped around a test lead.
Page 8
© PCE Instruments
6
6.2 Freeze measured value
To freeze the displayed reading, press and hold the HOLD key for two seconds. HOLD" appears on the display. To resume the measurement, press and hold the HOLD key again for two seconds.
7 Torch
To activate the torch, press the key for two seconds. To deactivate the torch, press and hold the key again for two seconds.
8 Replace / insert batteries
If the battery voltage is too low, the batteries must be replaced with new ones. Otherwise, incorrect measurements may occur. To replace or insert the batteries, first switch off the meter and disconnect the clamp from the test lead. Then open the battery compartment on the back. Insert new batteries and close the battery compartment again. The measuring device can now be used again.
Page 9
© PCE Instruments
7
9 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
10 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 10
© PCE Instruments
8
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Trafford House Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Chester Rd, Old Trafford 55010 Loc. Gragnano Pehlivan Sok. No.6/C Manchester M32 0RS Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom Italia Türkiye Tel: +44 (0) 161 464902 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 161 464902 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America Denmark
PCE Brookhuis B.V. PCE Americas Inc. PCE Instruments Denmark ApS Institutenweg 15 1201 Jupiter Park Drive, Suite 8 Birk Centerpark 40 7521 PH Enschede Jupiter / Palm Beach 7400 Herning Nederland 33458 FL Denmark Telefoon: +31 (0)53 737 01 92 USA Tel.: +45 70 30 53 08 info@pcebenelux.nl Tel: +1 (561) 320-9162 kontakt@pce-instruments.com www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 www.pce-instruments.com/dansk info@pce-americas.com www.pce-instruments.com/us