PCE Instruments PCE-LCM 50 User Manual

© PCE Instruments
PCE-LCM 50 Digital Microscope
User Manual
Last change: 17 December 2019
v1.0
English
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Delivery scope ....................................................................................... 1
3 Specifications ........................................................................................ 2
4 Device description ................................................................................ 3
5 Illumination ............................................................................................ 3
6 Description of user interface ............................................................... 4
7 Troubleshooting .................................................................................... 7
8 Warranty ................................................................................................. 8
9 Disposal ................................................................................................. 8
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Do not touch the lenses.
Use the dust cover when the microscope is not in use.
Non-observance of the safety notes can cause damage to the device and injuries to
the user.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business. If you have any questions please contact PCE Instruments. The contact details can be found at
the end of this manual.
2 Delivery scope
1 x Digital microscope PCE-LCM 50 1 x USB mouse 1 x Micro SD card 1 x Protective cover 1 x Contrast disc black / white 1 x Translucent lens 1 x Power supply 1 x Protective film 1 x User manual
© PCE Instruments
2
3 Specifications
Optical zoom
8.1 ... 32.4x
Optical lens
1 ... 4x
Barlow
0.3 times
Digital zoom
1 ... 10x
Max. object height
4 cm
Fixed working distance
90.5 mm
Image sensor
1/3", 3MP
White balance
Automatically or by pressing a button
Display resolution
1024 x 600 pixels
Frame rate
30 fps
Pixel size
2.75 x 2.75 μm
Interface
USB 2.0
Power supply mains adaptor Primary: 100 ... 240V
Secondary: 12V, 1A
Illumination reflected light
Ring with 21 x 2- mA LEDs, 5 levels adjustable
Illumination transmitted light
7 x 20-mA LEDs, 5 levels adjustable
Environmental conditions
-5 ... 40°C / 23 ... 104°F, 45 ... 85% rh
Dimensions
300 x 225 x 270 mm / 11.8 x 8.9 x 10.6 in
Weight
About 2.3 kg / 5.1 lbs
© PCE Instruments
3
4 Device description
1.
9“ display
2.
SD card slot
3.
Display on/off switch (standby)
4.
USB 3.0 interface
5.
Focusing wheel
6.
Illumination setting
7.
Connection for power supply (rear side)
8.
Display on/off switch
9.
Illumination for transmitted light microscopy
10.
Stage
11.
LED ring
12.
Mechanically adjustable zoom
5 Illumination
The microscope is equipped with an incident light illuminator and a transmitted light illuminator with 5 different brightness levels. To set the illumination, use the keys “INC“ for incident light and ”TRA“ for transmitted light.
© PCE Instruments
4
6 Description of user interface
The microscope has a user interface that opens as soon as the mouse touches the right-hand edge and closes as soon as the mouse leaves this area.
© PCE Instruments
5
Automatic exposure time
Manual setting of exposure time
White balance Automatic or by keystroke
Setting of image frequency (50 / 60 Hz)
Reset settings
Contrast setting
Setting the colour brightness
Setting the brightness
Setting the contrast of the image edges
Setting of noise suppression Setting of primary colour red
Setting of primary colour blue
Setting of colour temperature
Image zoom Flipping image horizontally
© PCE Instruments
6
Activating black/white mode
Activating/deactivating HDR
Image zoom out
Flipping image vertically
Image hold
Comparison of two live samples
Measurement lines memory: Up to 8 groups of measurement lines can be saved here.
Enable/disable all measurement lines
Reset measurement line settings
Save measurement line settings made
Shows the selected measurement line. Possible selections: 8 vertical and horizontal measurement lines, 1 centre point
© PCE Instruments
7
Enables/disables the measurement line last selected
Changes the colour of the measurement line last used
Changes the thickness of the measurement line last used
Time indication and setting
7 Troubleshooting
Error
Cause
Solution
The field of view is dirty Dirt is on the sample
Clean your sample.
Dirt is on the lenses
Clean the lenses.
Image unclear
Dirt is on the lenses
Clean the lenses.
Illumination does not work when supply voltage is connected
No voltage supply
Examine the mains adaptor.
Illumination defective
Contact PCE Instruments.
Dark image
Brightness setting too low
Increase brightness setting.
White balance inefficient
Set white balance manually.
Angle between display and microscope too wide
Change the angle.
No image displayed No voltage supply
Examine the mains adaptor and connection.
Display switch is in off position
Change the display switch position to on.
© PCE Instruments
8
8 Warranty
You can read our warranty terms in our General Business Terms which you can find here:
https://www.pce-instruments.com/english/terms.
9 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
© PCE Instruments
9
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 4 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
Germany United Kingdom Italy
PCE Produktions- und PCE Instruments UK Ltd PCE Italia s.r.l. Entwicklungsgesellschaft mbH Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6 Im Langel 26 Ensign Way, Southampton 55010 Loc. Gragnano D-59872 Meschede Hampshire Capannori (Lucca) Deutschland United Kingdom, SO31 4RF Italia Tel.: +49 (0) 2903 976 99 471 Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114 Fax: +49 (0) 2903 976 99 9971 Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824 info@pce-instruments.com info@industrial-needs.com info@pce-italia.it www.pce-instruments.com/deutsch www.pce-instruments.com/english www.pce-instruments.com/italiano
The Netherlands China Hong Kong
PCE Brookhuis B.V. PCE (Beijing) Technology Co., Limited PCE Instruments HK Ltd. Institutenweg 15 1519 Room, 6 Building Unit J, 21/F., COS Centre 7521 PH Enschede Zhong Ang Times Plaza 56 Tsun Yip Street Nederland No. 9 Mentougou Road, Tou Gou District Kwun Tong Telefoon: +31 (0)53 737 01 92 102300 Beijing, China Kowloon, Hong Kong info@pcebenelux.nl Tel: +86 (10) 8893 9660 Tel: +852-301-84912 www.pce-instruments.com/dutch info@pce-instruments.cn jyi@pce-instruments.com www.pce-instruments.cn www.pce-instruments.cn
United States of America Turkey
PCE Americas Inc. PCE Teknik Cihazları Ltd.Şti. 711 Commerce Way suite 8 Halkalı Merkez Mah. Jupiter / Palm Beach Pehlivan Sok. No.6/C 33458 FL 34303 Küçükçekmece - İstanbul USA Türkiye Tel: +1 (561) 320-9162 Tel: 0212 471 11 47 Fax: +1 (561) 320-9176 Faks: 0212 705 53 93 info@pce-americas.com info@pce-cihazlari.com.tr www.pce-instruments.com/us www.pce-instruments.com/turkish
Loading...