PCE-ITF 5 Infrared Thermometer
User manuals in various languages (français,
italiano, español, português, nederlands, türk, polski,
русский, 中文) can be found by using our
product search on: www.pce-instruments.com
Last change: 31 March 2020
v1.0

Contents
1 Safety notes ........................................................................................... 1
2 Delivery contents .................................................................................. 2
3 Specifications ........................................................................................ 2
4 Device description ................................................................................ 3
4.1 Display description ........................................................................................................... 4
5 Before making a measurement ............................................................ 4
5.1 Cleaning ........................................................................................................................... 4
6 Turning the meter on/off ...................................................................... 4
7 How to make a measurement .............................................................. 4
8 Settings .................................................................................................. 5
9 Laser ring ............................................................................................... 5
10 Distance-to-spot ratio ........................................................................... 6
11 Emissivity .............................................................................................. 6
12 Replacing the batteries ........................................................................ 7
13 Contact ................................................................................................. 7
14 Disposal ................................................................................................. 7
© PCE Instruments

© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The
device may only be used by qualified personnel and repaired by PCE Instruments personnel.
Damage or injuries caused by non-observance of the manual are excluded from our liability and
not covered by our warranty.
• The device must only be used as described in this instruction manual. If used otherwise,
this can cause dangerous situations for the user and damage to the meter.
• The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
• Do not expose the device to shocks or strong vibrations.
• The case should only be opened by qualified PCE Instruments personnel.
• Never use the instrument when your hands are wet.
• You must not make any technical changes to the device.
• The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
• The device must only be used with accessories from PCE Instruments or equivalent.
• Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
• Do not use the instrument in explosive atmospheres.
• The measurement range as stated in the specifications must not be exceeded under
any circumstances.
• Non-observance of the safety notes can cause damage to the device and injuries to
the user.
• Never target persons or animals with the laser beam.
• Never look into the laser beam directly.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of
business.
If you have any questions please contact PCE Instruments. The contact details can be found at
the end of this manual.

© PCE Instruments
2
2 Delivery contents
1 x infrared thermometer PCE-ITF 5
2 x 1.5 V AAA battery
1 x user manual
3 Specifications
-50 ... 550 °C /
-58 … +1022 °F
0 ... 550 °C / 32 … 1022 °F:
±(1.5 % of rdg. +2 °C / 4 °F)
Rest of range.: ±3 °C / 5.4 °F
-45 ... 60 °C /
-49 ... 140 °F
0 ... 45 °C / 32 … 113 °F:
±1 °C / 2 °F
Rest of range: ±1.5 °C / 3 °F
20 ... 80 % RH: ±4 % RH
Rest of range: ±5 % RH

© PCE Instruments
3
4 Device description
Humidity sensor and alarm LED

© PCE Instruments
4
4.1 Display description
Reading in degrees Fahrenheit
Reading in degrees Celsius
Batteries have insufficient voltage to operate meter properly
Laser active during a measurement
Lowest set limit value fallen below
Highest set limit value exceeded
Readings held. No measurement is taking place
5 Before making a measurement
In order to obtain a measurement result that is as accurate as possible, it is advisable to give the
measuring instrument at least 30 minutes to acclimatize in the event of strong ambient
temperature fluctuations.
Avoid strong electromagnetic fields (EFM).
Do not place the meter on heated surfaces. Always keep the meter clean.
5.1 Cleaning
In order to clean the sensor system, a mild and cleaned air pressure, for example from a
compressor, can be used to remove coarse dirt. A cotton cloth can then be used to remove any
dirt that is stuck.
6 Turning the meter on/off
To turn on the meter, apply the trigger. The meter will turn off automatically after 30 minutes.
7 How to make a measurement
To make a measurement, start by targeting the surface to be measured with the meter. Then
press and hold the trigger until the readings have stabilised. You can then read out the measured
values from the display.

© PCE Instruments
5
8 Settings
Various further settings can be made in the meter. Turn on the meter if you want to make any
settings. Now press and hold the “MODE“ key fror approx. 2 seconds. You are now in settings
mode. To leave the menu, press and hold the “MODE“ key again for approx. two seconds or press
and release the trigger. Use the arrow keys to change values. The menu hast he following levels:
Here you can set the alarm limit for the highest reading. When this set value is
exceeded, “Hi“ will be displayed and the alarm LED will glow.
Here you can set the alarm limit for the lowest reading. When this set value is fallen
below, “LOW“ will be displayed and the alarm LED will glow.
Here you can set the emissivity for the surface temperature measurement. Each
surface has its specific emissivity.
Here you can choose the temperature unit – either degrees Celsius or degrees
Fahrenheit.
To get to the desired function, press the “MODE“ key repeatedly.
9 Laser ring
The meter has a built-in laser for orientation purposes. To activate the laser, briefly press the
"MODE" key when you are in measurement view. The warning signal for the laser appears in the
display. If you now press the trigger for a measurement, the laser will be activated. As soon as
the measurement is finished, the laser will also be switched off.

© PCE Instruments
6
10 Distance-to-spot ratio
The distance-to-spot ratio of this meter is 12:1. This means that the distance between the surface
and the meter is 12 times larger than the measuring surface itself.
The farther the meter is away from the surface to be measured, the more space will be
measured. If the distance-to-spot ratio is too large, undesired surfaces may be included in the
measurement. This will cause incorrect readings.
11 Emissivity
Each surface has its own emissivity. In the following, you can find a rough list of different surfaces
and their emissivities.

12 Replacing the batteries
When the battery icon appears, the batteries must be replaced. To do so, first open the battery
compartment at the handle. Now replace the batteries by two new 1.5 V AAA batteries. Observe
correct polarity.
13 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact
us. You will find the relevant contact information at the end of this user manual.
14 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European
Parliament applies. Due to the contained pollutants, batteries must not be disposed of as
household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either reuse them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance
with your local waste regulations.
If you have any questions, please contact PCE Instruments.
© PCE Instruments
7

© PCE Instruments
8
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH
PCE Instruments France EURL
PCE Ibérica S.L.
Im Langel 4
23, rue de Strasbourg
Calle Mayor, 53
D-59872 Meschede
67250 Soultz-Sous-Forets
02500 Tobarra (Albacete)
Deutschland
France
España
Tel.: +49 (0) 2903 976 99 0
Téléphone: +33 (0) 972 3537 17
Tel. : +34 967 543 548
Fax: +49 (0) 2903 976 99 29
Numéro de fax: +33 (0) 972 3537 18
Fax: +34 967 543 542
[email protected] [email protected] [email protected]
www.pce-instruments.com/deutsch
www.pce-instruments.com/french
www.pce-instruments.com/espanol
Germany United Kingdom Italy
PCE Produktions- und
PCE Instruments UK Ltd
PCE Italia s.r.l.
Entwicklungsgesellschaft mbH
Unit 11 Southpoint Business Park
Via Pesciatina 878 / B-Interno 6
Im Langel 26
Ensign Way, Southampton
55010 Loc. Gragnano
D-59872 Meschede
Hampshire
Capannori (Lucca)
Deutschland
United Kingdom, SO31 4RF
Italia
Tel.: +49 (0) 2903 976 99 471
Tel: +44 (0) 2380 98703 0
Telefono: +39 0583 975 114
Fax: +49 (0) 2903 976 99 9971
Fax: +44 (0) 2380 98703 9
Fax: +39 0583 974 824
[email protected] [email protected] [email protected]
www.pce-instruments.com/deutsch
www.pce-instruments.com/english
www.pce-instruments.com/italiano
The Netherlands China Hong Kong
PCE Brookhuis B.V.
PCE (Beijing) Technology Co., Limited
PCE Instruments HK Ltd.
Institutenweg 15
1519 Room, 6 Building
Unit J, 21/F., COS Centre
7521 PH Enschede
Zhong Ang Times Plaza
56 Tsun Yip Street
Nederland
No. 9 Mentougou Road, Tou Gou District
Kwun Tong
Telefoon: +31 (0)53 737 01 92
102300 Beijing, China
Kowloon, Hong Kong
[email protected] Tel: +86 (10) 8893 9660
Tel: +852-301-84912
www.pce-instruments.com/dutch
[email protected] [email protected]
www.pce-instruments.cn
www.pce-instruments.cn
United States of America Turkey
PCE Americas Inc.
PCE Teknik Cihazları Ltd.Şti.
711 Commerce Way suite 8
Halkalı Merkez Mah.
Jupiter / Palm Beach
Pehlivan Sok. No.6/C
33458 FL
34303 Küçükçekmece -
İstanbul
USA
Türkiye
Tel: +1 (561) 320-9162
Tel: 0212 471 11 47
Fax: +1 (561) 320-9176
Faks: 0212 705 53 93
[email protected] [email protected]
www.pce-instruments.com/us
www.pce-instruments.com/turkish