PCE Instruments PCE-ILD 10 Users guide

Page 1
© PCE Instruments
PCE-ILD 10 Infrared Thermometer
User Manual
Last change: 10 May 2024
v1.0
English
Page 2
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Specifications ........................................................................................ 2
3 Delivery scope ....................................................................................... 2
4 Device description ................................................................................ 3
4.1 Display description ........................................................................................................... 4
5 Making a measurement ........................................................................ 5
6 Settings .................................................................................................. 5
7 Additional display ................................................................................. 6
8 Replace batteries .................................................................................. 6
9 Contact ................................................................................................... 7
10 Disposal ................................................................................................. 7
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business.
Page 4
© PCE Instruments
2
2 Specifications
Measurement range
-50 ... 500 °C / -58 ... 932 °F
Resolution
0.1 °C / 0.1 °F
Accuracy
±3 °C / ±5.4 °F at -50 ... 20 °C / -58 ... 68 °F ±2 or ±2°C / ±3.6 °F at 20 ... 500 °C / 68 ... 932 °F
Repeatability
±1 °C / 1.8 °F
Distance-to-target ratio
12:1
Emissivity
0.10 ... 1.00
Sampling rate
2 Hz
Spectral range
8 ... 14 µm
Measurement range exceeded
Display " - - - -"
Laser output power
<1 mW
Wavelength
630 ... 670 nm
Laser class
2
Illuminated ring
5 x white LED 5 x blue LED
Power supply
2 x 1.5 V AA batteries
Operating conditions
0 ... 50 °C / 32 ... 122 °F, 10 ... 90 % RH, non-condensing
Storage conditions
-10 ... 60 °C / 14 ... 140 °F, 10 ... 90 % RH, non-condensing
Dimensions
180 x 100 x 55 mm / / 7.0 x 3.9 x 2.1"
Weight
329 g / 11.6 oz with batteries
3 Delivery scope
1 x infrared thermometer PCE-ILD 10 2 x 1.5 AA battery 1 x transport bag 1 x user manual
Page 5
© PCE Instruments
3
4 Device description
No.
Description
1
Display
2
Operating toggle
3
Laser
4
LED ring
5
Infrared sensor
6
Measurement key
7
Battery compartment
Page 6
© PCE Instruments
4
4.1 Display description
No.
Description
1
Measurement is carried out
2
Display frozen
3
Laser is activated
4
Blue illuminated ring is active
5
Limit value alarm
6
Measured value
7
White illuminated ring is active
8
Temperature units
9
Additional display for the maximum, minimum, average and differential value
10
Set emissivity
11
Automatic power off
12
Battery status display
Page 7
© PCE Instruments
5
5 Making a measurement
Hold the meter firmly in your hand and point the sensor at the surface to be checked. Now press and hold the measurement key. The device will switch on automatically and start the measurement. "SCAN" is displayed.
The infrared sensor has a measuring spot ratio of 12:1, which means that at a distance of 12 metres, for example, the measuring spot has a diameter of 1 metre.
If you release the key, the measurement is interrupted and the display is frozen. "HOLD" is displayed.
6 Settings
To open or close the settings, move the operating toggle to the left. Press the operating toggle up or down to change the displayed parameter. The setting is applied directly. To go to the next setting, press the operating toggle to the right or inwards. The menu is organised as follows.
Display
Function
Switch the white illuminated ring on or off UV
Switch the blue illuminated ring on or off
Set the emissivity
°C / °F
Set the temperature unit
Switch the laser on or off
HI (ON/OFF)
Switch the upper limit alarm on or off As soon as the set limit value is exceeded, an audible and visual alarm is triggered.
HI [COUNT]
Set the upper alarm limit value
LO (ON/OFF)
Switch the lower limit alarm on or off As soon as the value falls below the set limit value, an audible and visual alarm is triggered.
LO [NUMBER]
Set the lower alarm limit value
MAX/MIN/AVG/DIFF
Switch the additional display on or off
APO
Set the automatic power off time in seconds
Page 8
© PCE Instruments
6
7 Additional display
If the additional display is activated, you can select between the individual functions in the measurement window by pressing the operating toggle up or down. The display is reset after pressing the measurement key.
Display
Function
MAX
Highest measured value
MIN
Lowest measured value
AVG
Average measured value
DIFF
Difference between MAX and MIN
8 Replace batteries
The battery compartment is located underneath the handle. To insert or replace the batteries as soon as they are discharged, first remove the battery compartment. Now insert new batteries. Ensure that the polarity is correct. You can then reinsert the battery compartment and resume measurement. Only use 2 x 1.5 V AA batteries. Note: As soon as the battery compartment is removed, all settings will be reset.
Page 9
© PCE Instruments
7
9 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
10 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 10
© PCE Instruments
8
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mula, 8 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Trafford House Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Chester Rd, Old Trafford 55010 Loc. Gragnano Pehlivan Sok. No.6/C Manchester M32 0RS Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom Italia Türkiye Tel: +44 (0) 161 464902 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 161 464902 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America Denmark
PCE Brookhuis B.V. PCE Americas Inc. PCE Instruments Denmark ApS Institutenweg 15 1201 Jupiter Park Drive, Suite 8 Birk Centerpark 40 7521 PH Enschede Jupiter / Palm Beach 7400 Herning Nederland 33458 FL Denmark Telefoon: +31 (0)53 737 01 92 USA Tel.: +45 70 30 53 08 info@pcebenelux.nl Tel: +1 (561) 320-9162 kontakt@pce-instruments.com www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 www.pce-instruments.com/dansk info@pce-americas.com www.pce-instruments.com/us
Loading...