PCE Instruments PCE-HTS 50, PCE-VTS 50, PCE-VTS 50-DFG N 500-KIT, PCE-VTS 50-PFG 500-KIT Users guide

Page 1
© PCE Instruments
PCE-VTS 50, PCE-HTS 50 Force Test Stand
User Manual
Last change: 6 March 2023
v1.0
English
Page 2
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Specifications ........................................................................................ 2
3 Scope of delivery .................................................................................. 2
4 Instrument description and dimensions............................................. 3
5 Display description ............................................................................... 4
6 User interface ........................................................................................ 5
7 Automatic and manual mode ............................................................... 6
8 Set travel distance ................................................................................ 6
9 Establish connection with a force gauge ........................................... 6
10 Contact ................................................................................................... 6
11 Disposal ................................................................................................. 6
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to the user.
It is recommended to wear eye protection during a compression or tensile test due to possible splinters from torn samples.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business.
Page 4
© PCE Instruments
2
2 Specifications
Force range
500 N / 50 kg / 110 lb
Travel distance
270 mm / 10.6"
Resolution of distance display
0.02 mm
Speed
1 ... 500 mm/min
Resolution
1 mm/min
Speed accuracy
2 %
Power supply
220 ... 240 V AC, 1.5 A
Fuse
2 A
Environmental conditions
20 °C ±10 °C, 15 ... 80 % RH, non-condensing
Dimensions
45 x 26 x 68 cm / 17.7 x 10.2 x 26.7"
Weight
35 kg / 77 lb
3 Scope of delivery
1 x motorised tension-compression test stand PCE-VTS 50 or PCE-HTS 50 1 x pulse cable for PCE-PFG series 4 x rubber foot 2 x Allen key 1 x power cable 1 x user manual
Page 5
© PCE Instruments
3
4 Instrument description and dimensions
PCE-VTS 50
PCE-VTS 50
Page 6
© PCE Instruments
4
5 Display description
No.
Description
1
Upper limit (limit switch)
2
Travel distance
3
Lower limit (limit switch)
4
User interface
5
Emergency switch
6
Cold-device connection for power supply
No.
Description
1
Status
2
Measuring mode
3
Unit
4
Unit for travel speed
5
Lowest set speed
6
Set speed
7
Highest set speed
8
Indicator whether lowest or highest speed has been selected
9
Travel distance
Page 7
© PCE Instruments
5
6 User interface
Key
Description
Switch between manual and automatic mode
Stop automatic mode
Start upward travel (PCE-VTS 50) or travel to the left (PCE-HTS 50)
Start downward travel (PCE-VTS 50) or travel to the right (PCE-HTS 50)
Switch to low speed (1 ... 99 mm/min)
Switch to full speed range
Switch to high speed (100 ... 500 mm/min)
Reset displayed travel distance
Increase speed
Reduce speed
Page 8
© PCE Instruments
6
7 Automatic and manual mode
In manual mode, the force gauge moves by pressing the arrow key for the direction of travel. In automatic mode, this is initiated via a keystroke. The force gauge stops as soon as it receives a stop commans, for example by pressing a key or from the limit switch.
8 Set travel distance
For the travel distance, both the upper and the lower limit can be set individually. When the slide reaches the limit, the motor stops directly.
9 Establish connection with a force gauge
To establish a connection with a force gauge of the PCE-PGF series, use the pulse cable included in the delivery. As soon as a pulse is sent from the force gauge, the force test stand stops. All settings for this can be found in the PCE-PFG series manual.
10 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
11 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 9
© PCE Instruments
7
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Ensign Way, Southampton 55010 Loc. Gragnano Pehlivan Sok. No.6/C Hampshire Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom, SO31 4RF Italia Türkiye Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America Denmark
PCE Brookhuis B.V. PCE Americas Inc. PCE Instruments Denmark ApS Institutenweg 15 1201 Jupiter Park Drive, Suite 8 Birk Centerpark 40 7521 PH Enschede Jupiter / Palm Beach 7400 Herning Nederland 33458 FL Denmark Telefoon: +31 (0)53 737 01 92 USA Tel.: +45 70 30 53 08 info@pcebenelux.nl Tel: +1 (561) 320-9162 kontakt@pce-instruments.com www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 www.pce-instruments.com/dansk info@pce-americas.com www.pce-instruments.com/us
Loading...