PCE Instruments PCE-HT 300 Users guide

Page 1
© PCE Instruments
PCE-HT 300 Thermo Hygrometer
User Manual
Last change: 20 July 2020
v1.0
English
Page 2
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Device description ................................................................................ 2
3 Delivery contents .................................................................................. 2
4 Specifications ........................................................................................ 2
5 Device overview .................................................................................... 3
6 Operation ............................................................................................... 4
6.1 Main surface .................................................................................................................... 4
6.2 Main menu ....................................................................................................................... 5
7 Warranty ............................................................................................... 11
8 Disposal ............................................................................................... 11
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualified PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specifications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business. If you have any questions please contact PCE Instruments. The contact details can be found at
the end of this manual.
Page 4
© PCE Instruments
2
2 Device description
The PCE-HT 300 is a data logger for temperature, humidity and dew point temperature. It can record, display and store ambient temperature and humidity. Readings are displayed as a curve and as a digital value. The data are stored directly to the device to enable continuous recording of temperature and humidity.
3 Delivery contents
1 x temperature and humidity data logger 1 x wall mounting frame 1 x USB cable 1 x extension cable for the probe 1 x temperature and humidity probe 1 x mains adaptor 5V/2A
4 Specifications
Measurement function
Measurement range
Resolution
Accuracy
Temperature
-10 ... 80 °C
0.1 °C
±0.5 °C
Dew point
-10 ... 80 °C
0.1 °C
±0.5 °C
Air humidity
0 ... 100 % RH
0.1 % RH
<80 % RH: ±2 % >80 % RH: ±2.5 %
Display
7" touch screen
Memory
16 GB
Memory format
CSV
Power supply
3000 mAh Li-Ion battery 5 V / 2 A mains adaptor
Battery life
approx. 5 years
Dimensions
180 x 115 x 18 mm
Weight
approx. 450 g
Page 5
© PCE Instruments
3
5 Device overview
Touch screen Probe (shown with extension cable) Table stand (built-in) and wall mounting frame Slot (socket) for the probe or extension cable ON/OFF switch USB interface for charging and data transfer to the PC
NOTE: Before using the instrument, insert the probe into the slot on the back side. Then press the ON/OFF switch to turn on the unit.
Page 6
© PCE Instruments
4
6 Operation
6.1 Main surface
1. Memory usage, "Free" shows the remaining memory space
2. Date (month/day/year) and time
3. Battery level
4. Menu function
5. Vertical axis - scale for temperature (in the diagram on the right for relative humidity)
6. Curves with the time course of temperature, humidity and dew point
7. Horizontal axis - scale for date and time
8. Max/Min
9. Current value for temperature (temperature), humidity and dew point
If no entry is made, the data logger automatically switches to the large display of the current values after 1 minute. This display shows: Humidity, temperature and dew point.
You can return to the main interface by touching the screen.
Page 7
© PCE Instruments
5
6.1.1 Graphical part of the main interface
The red curve shows the temperature curve.
The green curve shows the temporal course of the air humidity.
The yellow curve shows the course of the dew point temperature.
The vertical axes show the values for temperature and relative humidity.
The horizontal axes show the value for date and time.
The vertical yellow line marks the value at a certain time. It appears when you tap a part of
the curve. The line can be moved with "<<" or ">>".
6.1.2 Digital part of the main interface
"Temperature" shows the value of the temperature.
"Humidity" shows the value of the air humidity.
"Dew Point" shows the value of the dew point temperature.
By touching one of the three circles, you can access the large display of the current values.
6.2 Main menu
By clicking on the menu icon (top right in the main interface), you can access the menu interface.
Page 8
© PCE Instruments
6
6.2.1 Settings
You can make the following settings (a) Unit of temperature Unit degrees Fahrenheit or degrees Celsius b) Alarm Touch the display field to switch the alarm on or off (c) Maximum and minimum temperature and humidity The alarm must be enabled before values can be entered. Enter the values using the keypad and confirm with OK. d) Sample rate Here you can define how often the alarm data are saved. H: for hours, M: for minutes, S: for seconds
Tap on "Save" to accept the settings. Note:
When the alarm is triggered, the instrument beeps and the large display shows the temperature alarm icon or humidity alarm icon or both in the upper right corner.
Page 9
© PCE Instruments
7
6.2.2 Alarms
Here you can display the saved alarm values sorted by date or by value. There is only space for 3 values in the display window. You can see the other values by moving the list up or down.
Sorted by date:
Sorted by value:
Page 10
© PCE Instruments
8
6.2.3 History
The temperature and humidity data are saved here.
Via "Delete", you can delete all selected data.
If you select a saved record by tapping on it, you can open or delete it.
Page 11
© PCE Instruments
9
After opening the data record, you can view its values graphically and digitally, displayed as during the measurement.
With the back arrow in the upper left corner, you can return to the menu interface with the list of data records.
6.2.4 Delete Files
CSV files are automatically created and can be transferred to the PC. You can delete individual files or all files here.
Page 12
© PCE Instruments
10
6.2.5 Display
Here you can adjust the screen brightness.
Move the dot on the line to the left or right to increase or decrease the brightness.
6.2.6 Date & Time
To change the values, tap on the range.
Page 13
© PCE Instruments
11
You can adjust the values for year, month, day, hour, minute individually by sliding them up or down. Confirm the changes with "Yes".
7 Warranty
You can read our warranty terms in our General Business Terms which you can find here:
https://www.pce-instruments.com/english/terms.
8 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 14
© PCE Instruments
12
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 4 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 info@pce-instruments.com info@pce-france.fr info@pce-iberica.es www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Ensign Way, Southampton 55010 Loc. Gragnano Pehlivan Sok. No.6/C Hampshire Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom, SO31 4RF Italia Türkiye Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 info@pce-instruments.co.uk info@pce-italia.it info@pce-cihazlari.com.tr www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands China Hong Kong
PCE Brookhuis B.V. PCE (Beijing) Technology Co., Limited PCE Instruments HK Ltd. Institutenweg 15 1519 Room, 6 Building Unit J, 21/F., COS Centre 7521 PH Enschede Zhong Ang Times Plaza 56 Tsun Yip Street Nederland No. 9 Mentougou Road, Tou Gou District Kwun Tong Telefoon: +31 (0)53 737 01 92 102300 Beijing, China Kowloon, Hong Kong info@pcebenelux.nl Tel: +86 (10) 8893 9660 Tel: +852-301-84912 www.pce-instruments.com/dutch info@pce-instruments.cn jyi@pce-instruments.com www.pce-instruments.cn www.pce-instruments.cn
United States of America
PCE Americas Inc. 711 Commerce Way suite 8 Jupiter / Palm Beach 33458 FL USA Tel: +1 (561) 320-9162 Fax: +1 (561) 320-9176 info@pce-americas.com www.pce-instruments.com/us
Loading...