PCE Instruments PCE-HT-225A Users guide

Page 1
OPERATION MANUAL
Sino Age Development Techtrade Ltd.
-
User Manual
Page 2
03
Table of contents
Chapter1 - General Description ........................................................................................................... 4
1.1. Applications ....................................................................................................................... 4
1.2. Basic principle ................................................................................................................... 4
1.3. Structure of Concrete Test Hammer .................................................................................. 4
1.4. Main technical specifications ............................................................................................ 5
Chapter2 - Operating and Testing Methods of Concrete Test Hammer .............................................. 6
2.1. Operating method of Concrete Test Hammer ................................................................... 6
2.2. Testing method of Concrete Hammer ............................................................................... 7
2.2.1. Preparatory process of test ................................................................................................ 7
2.2.2. Rules for resilience test ..................................................................................................... 8
2.2.3. Determination of carburized depth .................................................................................. 10
Chapter3 - Processing of test data ..................................................................................................... 12
3.1. Calculation of resilience value ........................................................................................ 12
3.2. Calculation of carburized depth ...................................................................................... 14
3.3. Evaluation of concrete strength ....................................................................................... 14
Chapter4 - Maintenance of Concrete Test Hammer .......................................................................... 17
Appendix 1 - Common faults of the Concrete Test Hammer and the analysis on their causes ......... 18
Appendix 2 - Conversion table of concrete strength value of test zone ............................................. 20
Page 3
04
Chapter 1 - General Description
1.1. Applications
With the merits of simple structure, easy correction, maintenance and repair, and portability, the Concrete Test Hammer is widely used in civil engineering and construction industry for testing the strength of concrete. Compared to other nondestructive testers, the Concrete Test Hammer is an economical and practical nondestructive testing instrument. HT-225A is a medium Concrete Test Hammer, its kinetic energy of impact is 2207J(0.225kgfm).It is extensively used for testing the strength of various concrete members (slab, beam, column) of normal building strength and bridge.
1.2. Basic principle
When testing the strength of concrete, Concrete Hammer uses a certain elastic force to transit the impact force of an impact hammer to the surface of concrete, its initial kinetic energy redistributes, a part of energy in the form of plastic deformation or residual deformation is absorbed by the concrete, and another part of energy which is proportional to the surface hardness is transmitted to the impact hammer, making the hammer resile to a certain height, then the strength of the concrete is derived from the proportional relation between the height of resilience and the concrete strength
1.3. Structure of Concrete Test Hammer
The Concrete Test Hammer is mainly composed of flip system, value-indicating system and shell component.Its structure is shown in Fig.1. The diagram shows the state that the impact hammer has finished impact in the test and the pushbutton has locked the movementieretaining state of resilience value
Page 4
05
1Flip rod 2Test surface 3Shell 4Pointer block 5Dividing rule 6Pushbutton 7Center guide rod 8Guide flange 9Cap 10Clasp 11Tail hood 12Pressure spring 13Hanger 14Impact hammer 15Buffer pressure spring 16Flip tension spring 17Tension spring seat 18Felt ring 19Bolt 20Nut 21Pointer piece 22Pointer shaft 23Hanger 24Hanger dowel
Fig(1)
1.4. Main technical specifications
The main performance indicators of HT-225A Concrete Test Hammer are as follows
1) Nominal kinetic energy: 2.207J(0.225kgfm)
2) Mean value of steel-anvil ratings of Concrete Test Hammer: 80±2
3) Overall dimension: φ66×280mm
4) Weight: 1kg
5) Test thickness: 70cm
Page 5
06
Chapter 2 - Operating and Testing Methods of
Concrete Test Hammer
2.1. Operating method of Concrete Test Hammer
To use and operate the correctly can give better play to its efficiency and improve the accuracy of testTherefore, the operating personnel of the instrument must carry out operation according to the stipulated operating rules and requirementIn the whole process of the instrument, it is necessary to pay attention to the correct gesture of holding the instrumentThe correct gesture of holding the instrument is that one hand holds the middle portion of the instrument, and which also plays the function of straightening up in the whole processanother hand holds and presses the tail hood of the instrument, and which is mainly for exerting pressure on the instrument while also playing the auxiliary function of straightening up The basic points of the operation of the Concrete Test Hammer are that the force used must be even and slow, the Concrete Test Hammer should be straightened up to vertically aiming at the test surface, and should not be swayed The operating procedures of the Concrete Test Hammer are as follows
2.1.1. Make the flip rod 1 of the Concrete Test Hammer press against the surface of concrete,
lightly press the tail hood 11 to make push-button 6 release guide flange 8, under the action of pressure spring 12,the guide flange brings along the pointer block to move downward to “0” position;at that time, hanger 13 links with the tail of impact hammer, the flip rod extends out from the shell of instrument, then test can be carried out During this process of operation, when the pushbutton releases the guide flange, the operator’s two hands should raise the Concrete Test Hammer to leave the test surface of concrete which it originally pressed against, the speed of raising should be quick so as to make it easier for the hanger to link with the impact hammer
2.1.2. Maker the extended flip rod aiming at the test point of the test surface of the test
specimen of concrete and keep the center axis of the Concrete Test Hammer to be perpendicular to the test surfacethen use one hand to hold the instrument shell 3, and other hand to slowly and evenly hold and press the tail hood 11, at that time flip tension spring 16 is stretched, the flip rod is pressed into the instrument shell,i.e.the impact hammer 14 obtains the energy from the flip tension spring. When being pushed and pressed to a certain position, the back of hanger 13 touches the bolt 19 on the tail hood, at that time flip tension spring should be stretched by 75mm, the impact hammer 14 has obtained an energy of 2.207J specified by the design of the
Page 6
07
instrument, and is at position ready to be set off at a touch. During this process of operation, care must be taken not to use too much strength to result in an impact, and the center axis of the instrument should always be kept perpendicular to the test surface without sway
2.1.3. The impact hammer will be disconnected with the hanger when continuing to exert
pressure on the tail hood.Owing to the action of the flip tension spring 16,the impact hammer rapidly impacts along the center guide rod 7 toward the flip rod 1, the kinetic energy is transmitted to the concrete test specimen through the flip rod During this process of operation, the impact hammer collides with the flip rod many times, therefore the operator must hold the Concrete Hammer firmly swaying, and make the axis of the instrument keeping perpendicular to the test surface
2.1.4. After resiling, the impact hammer brings the pointer block 4 to a certain position, then
the operator should continue holding and pressing the Concrete Hammer to keep the flip rod against the test surface, and read from the dividing ruler the value N corresponding to the dividing line on the pointer block 4If the light is dim or it is inconvenient to read, the operator can, after finishing flip, press down the pushbutton 6 to lock the guide flange, making the pointer block 4 keep in position, then take the instrument to a place where it is convenient to observe, so as to read the value N and make a record The abovementioned is the whole process of one flip test and the operator can obtain a resilience value, and by repeating this process the required resilience value of the test point can be obtained
2.2. Testing method of Concrete Hammer
To strictly execute the technical rules of Concrete Hammer and skillfully master the testing technology of the Concrete Hammer, the basic performance and operating method of the instrument are the prerequisites for smoothly carrying on the test of strength by the resilience method As for the provinces and cities that have established regional resilience curves and the regional technical rules of resilience method, they can also adopt regional curves or execute regional rulesThose provinces and cities that have not established resilience curves or rules should theTechnical Rules for the Evaluation of Compression Resistance of Concrete by Using JGJ123-85 resilience method".
2.2.1. Preparatory process of test
1) Selection of test zone
Page 7
08
In accordance with the requirement of technical rules of resilience methods, the test zone should be selected on the representative member according to the quality condition of the member AThe test zone should be selected on the lateral face of the concreting ( the side of laidon shutter board that is perpendicular to the concreting direction)If it is impossible to meet this requirement, it can be selected on the concreting surface or bottom BThe test zone should be selected on the surface of the exposed part of the member where it is easy to measure the resilience value and the carburized depth CThe test zone should be selected on the two basically symmetrical test surfaces (hereinafter referred to test surface ) on two relative surfaces of the memberIf it is impossible to meet this requirement, it is allowed to have only one test surface DThe surface of test zone should be clean, flat and dry, and must not have joint, finishing coat, rendering coat, laitance, oil stain, and voids and pits, the grinding wheel provided with the machine can be used to clean the surface impurity substances and polish the rough places if necessary, and the surface should not have any residual powder or debris
2) The number of test zones on every test member should be no less than 10, and
they should be evenly distributed on the test surface, and should bypass the reinforcing bar and embedded iron parts within the concrete or set up nearby
3) The spacing between two adjoining test zones should not be greater than 2m
4) It is desirable that the size of test zone can hold 16 resilience test points, usually is
about 400cm2
5) Test points should be evenly distributed within the scope of test zone, the spacing
between two adjoining test points should not be less than 3cm, the distance between the test point and the edge of member or exposed reinforcing bar and iron parts should not be less than 5cmTest points should bypass reinforcing bar, air hole and exposed stone
2.2.2. Rules for resilience test
1) According to the standard condition of Concrete hammer, test the instrument and
it should measure up to the standard
2) According to the technical rules of resilience method, select and arrange test zones,
test surfaces and test points and they should have clear numbering marks
3) All the smallsized and lowrigidity members or those with the test location
less than 10cm thick, should be provided with support to fix it securely, then test can be carried out
4) If the test surface layer of the concrete has been wetted for a short term, test
should not be carried out until the surface layer is dried by air.
Page 8
09
5) Steamcured concrete should not be tested until that the member has undergone a
natural curing for 14 days after being taken out from the curing pit
6) The reading accuracy of the resilience value should be up to 1 in the test, and the
measured resilience value should be noted on the test record sheet
7) Each test point can be tested only once, no repeated resiliences and tests on the
same point are allowed
8) The two relative test surfaces of each test zone should be tested on 8 points each,
and 16 points in totalIf tests can only be carried out on one test surface, then test on 16 points should be carried out on that surface(The test surface can be expanded appropriately if permitted)
9) To the nonhorizontally tested surface, the included angle between the center axis
of Concrete Test Hammer and the horizontal line should be determined, and the +or"-"angle value and the corresponding resilience value should be notedThe positive and negative included angles are shown Fig2
10) When tests are carried out on concreting surface, the measured resilience values
should be noted withbottom,toporlateral face".
11) Whether the test surface is carburized or not should be timely judged, and should
be noted for the measured resilience value
12) The dry and wet degree of the test surface should be judged and should be noted
with dry surface or wet surface and their respective resiliences values
13) If the surface layer and the interior of the test location of the concrete are not of
the same quality and show obvious difference, or there are serious defects in concrete, they are not suitable for resilience tests
14) Concrete that has suffered chemical corrosion, fire, cold injury during hardening
period, hightemperature or humid environment for a long period of time or has been impregnated with water is not suitable for resilience tests
Page 9
10
Fig2 Diagram of test angle α
15) When the ambient temperature is lower then 5 or higher than 35, it is not
suitable to carry out resilience tests
16) If the radius of curvature of the test location is small than 23cm, it is not suitable
to carry out resilience tests
2.2.3. Determination of carburized depth
Carburization is the main factor of affecting the test of concrete strength by resilience method, therefore it is necessary to carry out the measurement of carburized depth immediately after the resilience tests, and the measurement result should be taken as the basis of the determination of concrete strengthThe measuring method is as follows
1) Use a proper tool to make a hole of 15mm diameter in the location,the hole depth
is slightly greater than the carburized depth of the concrete
2) Clean away powder and debris in the hole, but it is forbidden to wash by liquid
3) After the cleaning, immediately drip 1% alcoholic phenothalin solution on the
hole wall.The uncarburized concrete will change color to a purplish red while the carburized concrete will not change color
Page 10
11
4) Use steel ruler to measure once or twice the vertical distance from the test surface
to the place on the hole wall where color is unchanged, the accuracy is to
0.5mmThat distance is the very carburized depth of that test zone
5) For determination of the value of carburized depth, it is necessary to select one
test point for one test zoneIf the concrete qualities or resilience values of two adjoining test zones are basically similar, then the value of the adjoining carburized depth can be used as representative
Page 11
Nα
Test angleα
90O
+90O
+60O
+45O
+30O
30O
45O
60O
20
60
50
40
30
+2.5
+3.0
+3.5
+4.5
30
50
40
35
25
+2.0
+2.5
+3.0
+3.5
12
Chapter 3 - Processing of test data
3.1. Calculation of resilience value
When the Concrete Test Hammer is used to test the lateral face of concreting in the horizontal direction, the three greatest values and three smallest values in the 16 resilience values should be rejected, take the remaining 10 resilience values and calculate the mean resilience value of the test zone by the following formula
(1)
WhereN――mean resilience value of the test zone, the calculated value keeps valid up to one digit after decimal point Ni――resilience value of the i test point. When the Concrete Hammer is used to test the lateral face of concreting in nonhorizontal direction, the measured data should data should be used first to calculate the mean resilience value Nα of the test zone by formula (1) according to the angle α between the axis of Concrete Hammer and the horizontal direction, then convert it by the following formula into the mean resilience value of the test zone tested in horizontal direction
N=Nα+△N Where, N――mean resilience value of the test zone tested when the Concrete Hammer and the horizontal direction are in an α angle, the calculated value keeps valid up to one digit after decimal point Nα ―― the correction values of resilience values at different test angles consulted from Table 1, the value keeps valid up to one digit after decimal point The correction values Nα of resilience values tested in nonhorizontal state
Correction values Nαof resilience values at different test angles α Tab.1
(2
S
Page 12
40
-4.0
35
-3.0
20
+1.5
+2.0
+2.5
+3.0
50
-3.5
-3.0
-2.0
-1.5
+1.0
+1.5
+2.0
+2.5
Ns Ns
surface
bottom
20
25
30
25
20
25
30
15
20
35
10
15
40
05
10
45
0
05
50 0 0
13
Note:The Nα correction values corresponding to Nα that have not been listed in the table can be obtained by using interpolation, with an accuracy to one digit after point When the Concrete Hammer is used to test the concreting surface or bottom in nonhorizontal direction, they should be converted into the mean resilience value of the test zone of the lateral face of concreting respectively according to the following formula N=Ns+Ns (3) Where, Ns――the mean resilience value of the test zone of the concreting surface or bottom, the calculated value keeps valid up to one digit after decimal point Ns―― correction value of concreting surface or bottom, consulted from the table, keeping valid up to one digit after decimal point Correction values of resilience values of different concreting surfaces(See Tab2)
Correction values Ns of resilience values of different test surfaces Tab2
Note (1) The Ns correction values corresponding to Ns that have not been listed in the table can be obtained by using interpolation, with an accuracy to one digit after decimal point (2) In the table, the correction values related to the concreting surface refer to the correction values after ordinary mortar rendering (3) In the table, the correction values related to the concreting bottom refer to the correction values under normal concreting condition when the surface and bottom of a structure or a member adopt same kind of shuttering (4) In the test, if neither the Concrete Hammer is in horizontal direction nor the test zone is the lateral face of concreting, an angle correction for the resilience value should be carried out first , then the revision of concreting surface is carried out
Page 13
3.2. Calculation of carburized depth
14
The mean value of carburized depth of each test zone should be calculated according to the following formula
(4) Where, L――the mean value of carburized depth (mm) of the test zone, the calculated value keeps valid up to one digit after decimal point Li――The value of carburized depth(mm) measured at i time; n――Times of measurement of carburized depth of test zone If the mean value of carburized depth L calculated according to formula (4) is smaller than or equal to 0.4 mm, then it should be treated as uncarburized, i.e.L is 6mm, then it should be calculated according to a mean value of carburized depth L =6mm
3.3. Evaluation of concrete strength
The determination of concrete strength can be divided into individual evaluation and sampling evaluationThe usual sequence is as followsfirst set the strength of test zone, then the strength of test specimen, and then the strength of member and the strength of the whole structureOn general condition, individual members are used as the basic units for evaluating the strength of concrete.On the basis of evaluating the strength of the sampled members respectively, the strength evaluation for whole structure can be carried out Determination of the strength Rni of test zone On the basis of the mean resilience value N of each test zone (after calculation and correction, keep valid up to one digit after decimal point) and the mean carburized depth L, find out the strength value Rni of the corresponding test zone by referring to the data listed in the conversion tableThe conversion table is seen in Appendix 2 Determination of the strength Rn of test specimens The mean strength value Rn of the concrete specimens should be calculated according to the following formula
(5) Where, Rn――the mean strength value of the concrete specimen(MPa),keeping valid up to one digit after decimal point n――for the structure or member evaluated individually, take the number of test zone of a test specimen;for structure or member evaluated by sampling, take the sum of the numbers of the test zones of the sampled specimens
Page 14
n
1014
1524
25
k
17
165
16
15
The strength values of the concrete specimens under the first condition and under the second condition can be calculated according to the following formulas
Rn1= 18 (Rn-KSn) (6) Rn2= 18 (Rni) min (7) Where , Rn1―― the strength value of the concrete specimen under first condition MPa, accuracy keeping valid to one digit after decimal point Rn2―― the strength value of the concrete specimen under second condition (MPa), accuracy keeping valid to one digit after decimal point Sn―― the strength standard difference of the concrete specimens (MPa), calculated on formula (8), accuracy keeping valid to two digits after decimal point
(8)
(Rni) minFor the structure or member evaluated individually, take the lowest concrete strength value (MPa) in a test specimen of the test zone for the structure or member evaluated by sampling, take the lowest concrete strength value (MPa) in every sampled specimen of the test zone KThe acceptance coefficient values should be taken from Table 3 nFor the structure or member evaluated individually, take the number of the test zones of a test specimenfor the structure or member evaluated by sampling, take the sum of the numbers of the test zones of the sampled specimens
The acceptance coefficient values Tab3
To determine the evaluated strength value of the concrete specimen, the following rules should be observedFor the structure or member evaluated individually, take the smaller value in formula (6) or (7);for the structure or member evaluated by sampling, take the smaller value in formula (6) or (7) in the sampled specimens The evaluation of the strength Rn of a structure or a member The evaluated concrete strength value Rn of a structure or a member should be taken according to the following rules
1) Individual evaluation For the structure or member evaluated individually, the evaluated strength value of the concrete specimen is the very evaluated strength value of the concrete of an individual structure or member
2) Sampling evaluation
Page 15
16
For the structure or member evaluated by sampling, the evaluated strength value of the concrete specimen is the very evaluated strength value of the concrete of the structure or member equivalent to those in the same acceptance batch and with similar age and under the same condition of production process
Page 16
17
Chapter 4 - Maintenance of Concrete Test Hammer
To improve the testing accuracy of the resilience method, besides the correct operation and use of instrument and the mastery of the testing technology, always keeping the instrument in a sound and standard state is an important aspect Besides that the instrument should be used and kept by the specific personnel, the following rules should be observed
1) After use of the Concrete Test Hammer, it should be timely put into the leather
case to prevent dust from entering the interior of the instrument
2) Do not dismantle and try the instrument ad lib, or its service life and accuracy will
be impaired
3) The instrument should be maintained periodicallyAfter is has been used for a
certain period of time, it should be wiped clean, but the assembling relation between the parts and components and the whole machine should not be altered
4) Except for doing the necessary steelanvil rating, the instrument should be
avoided to try flip on substances that have a higher hardness than concrete
Page 17
No
State of faults
Analysis on causes
1
When concrete hammer flips in test, the pointer block stays at the starting position and will not move
The field angle of the pointer piece on pointer block relative to pointer shaft is too small The pointer piece is fractured
2
In the process of flipping, pointer block sways and rises step by step
The field angle of pointer piece on pointer block is somewhat small The fitting between pointer block and pointer shaft is too loose Pointer block touches and rubs with dividing ruler locally or the local friction between pointer block and the groove of machine shell is too great
3
Pointer block is carried up before flipping, making reading impossible
The field angle of pointer piece on pointer block is too large
4
Impact hammer strikes too early
he hook end of hanger has become a small obtuse angle 2The tail end of impact hammer is locally broken
18
Appendix 1 - Common faults of the Concrete Test Hammer and the analysis on their causes
Page 18
5
Incapable of flipping
1Hanger spring has dropped 2The hook end of hanger is fractured or has become an obtuse angle owing to friction 3 The flipping tension spring has been fractured
6
The flipping rod cannot extend out, thus being useless
Pushbutton will not act
7
The flipping rod is easy dropping
The fitting between the end of center guide rod and the inner hole of flipping rod is not tight
8
The rated value of the instrument in normal state is on the low side
1There are dirts on the impact plane of impact hammer and flipping rod 2.There are dirts between impact hammer and center guide rod, so the friction has augmented 3.The contact of impact faces between impact hammer and flipping rod is uneven 4.Partial claw at the end of center guide rod is fractured 5The movement is damaged
19
Page 19
20
Rebound
value
MPa
Impact direction
Horizontal
Impact direction
90°
60°
45°
30°
-30°
-45°
-60°
-90°
20
10.3
10.3
10.3
10.3
10.3
13.1
13.7
14.3
14.9
21
10.3
10.3
10.3
10.3
11.4
14.3
14.9
15.5
16.2
22
10.3
10.3
10.3
10.3
12.5
15.4
16.0
16.7
17.4
23
10.3
10.3
10.3
10.4
13.7
16.7
17.4
18.0
18.8
24
10.3
10.3
10.5
11.6
14.9
17.9
18.6
19.3
20.0
25
10.3
10.8
11.6
12.7
16.2
19.2
20.0
20.8
21.5
26
11.0
12.0
12.8
14.0
17.5
20.6
21.4
22.1
22.8
27
11.9
13.3
14.0
15.3
18.9
22.1
22.8
23.6
24.5
28
13.4
14.6
15.4
16.7
20.3
23.5
24.3
25.0
25.9
29
14.8
16.0
16.7
18.0
21.8
25.0
25.9
26.7
27.6
30
16.2
17.5
18.2
19.6
23.3
26.5
27.4
28.2
29.1
31
17.6
18.9
19.6
21.0
24.9
28.2
29.1
30.0
30.9
32
19.1
20.8
21.2
22.7
26.5
29.8
30.7
31.6
32.5
33
20.8
22.0
22.7
24.3
28.2
31.6
32.5
33.5
34.4
34
22.4
23.6
24.5
26.0
30.0
33.3
34.2
35.2
36.1
35
24.1
25.2
26.0
27.8
31.8
35.2
36.1
37.1
38.2
36
25.9
27.1
27.9
29.6
33.6
36.9
37.9
38.9
39.9
37
27.8
28.8
29.6
31.4
35.5
38.9
39.9
41.0
42.0
38
29.6
30.7
31.6
33.5
37.5
40.7
41.8
42.8
43.9
39
31.6
32.5
33.5
35.4
39.5
42.8
43.9
45.0
46.1
40
33.6
34.6
35.5
37.5
41.6
44.8
45.9
47.0
48.1
41
35.5
36.5
37.5
39.5
43.7
47.0
48.1
49.2
50.4
42
37.7
38.7
39.7
41.8
45.9
49.0
50.2
51.3
52.5
43
39.7
40.7
41.8
43.9
48.1
51.3
52.5
53.6
52.5
44
42.0
43.0
44.1
46.3
50.4
53.4
54.6
55.8
57.0
45
44.1
45.2
46.3
48.5
52.7
55.8
57.0
58.2
59.5
46
46.5
47.6
48.7
51.0
55.0
58.0
59.2
60.0
47
48.7
49.9
51.0
53.4
57.5
48
51.3
52.5
53.6
56.0
60.0
49
53.6
54.8
56.0
58.5
50
56.8
57.5
58.8
60.0
20
Appendix 2 - Conversion table of concrete strength value of test zone
Loading...