PCE Instruments PCE-HT 110 User Manual

Manual
Hygrometer
PCE-HT 110
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
Y
our purcha
se of this HUMIDITY/B
AROMETER/TEMP. Monitor wi
th SD CAR
D dat
alogger
ma
rks
a
step forward fo
r y
ou into th
e field of precis
ion measureme
nt. Although thi
s da
talogger
is
a
complex
and delica
te instrume
nt, its dur
abl
e structure w
ill allo
w many years of use if prop
er
operating
techniques are deve
loped. Please re
ad th
e f
ollowing in
struct
ion
s caref
ully and alwa
ys
kee
p thi
s m
anual with
in ea
sy reac
h.
TABLE OF CONTENTS
1. FEATURES..................................................................
1
2. SPECIF
ICATIONS.........................................................1
3. FRONT PANEL DESCRIPTION.......................................
4
3-1 Display..................................................................4
3-2 Logger button, Enter button...................................4
3-3 button, Time button........................................... 4
3-4 button............................................................... 4
3-5 SET button............................................................4
3-6 Humidity/Temp. sensor..........................................4
3-7 Hanging holes........................................................4
3-8 Stand....................................................................4
3-9 Battery cover/Battery compartment.........................4
3-10 Screw of the battery cover....................................4
3-11 Reset button........................................................4
3-12 RS-232 output terminal........................................ 4
3-13 SD card socket.....................................................4
3-14 DC 9V power adapter input socket........................4
3-15 Hanging unit ( with sticker )................................. 4
4. MEASURING PROCEDURE............................................5
5. DATALOGGER.............................................................5
5-1 Preparation before execute datalogger function.......5
5-2 Datalogger........................................................... 7
5-3 Check time information.......................................... 7
5-4 SD Card Data structure.......................................... 8
6. Saving data from the SD card to the computer..............9
7. ADVANCED SETTING...................................................10
7-1 SD memory card Format.........................................11
7-2 Set clock time ( Year/Month/Date, Hour/Minute/
Second ).............................................................. 11
7-3 Set sampling time..................................................12
7-4 Set beeper sound ON/OFF......................................12
7-5 Set SD card Decimal character................................13
7-6 Select the Temp. unit to or ............................℃℉ 14
7-7 Set RS232 data output ON/OFF...............................14
8. POWER SUPPLY from DC ADAPTER..............................15
9. BATTERY REPLACEMENT.............................................15
10. SYSTEM RESET.........................................................15
11. RS232 PC serial interface...........................................16
12. PATENT....................................................................17
1. FEATURES
*
Monitor with real time data logger, save the measuring data along the time information ( year, month, date, minute, second ) into the SD memory card and can be down load to the Excel, extra software is no need. User can make the further data or graphic analysis by themselves.
*
Show Humidity and Temperature value in the same LCD.
*
0.1 %RH resolution for the humidity reading,
0.1 degree resolution for the Temp. reading.
* Used the precision capacitance type humidity sensor,
professional and high accuracy. * SD card capacity : 1 GB to 16 GB. * Sampling adjustment : 5/10/30/60/120/300 seconds
and auto function. * Large LCD display, easy readout. * Microcomputer circuit, high reliability. * Low power consumption and long battery life when
use battery power. * DC 1.5V ( UM-4, AAA ) battery x 6 PCs or DC 9V
adapter in. * RS232/USB computer interface available. *Patented
2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor LSI
circuit. Display LCD size : 60 mm x 50 mm Measurement Humidity and Temperature Memory Card SD memory card, 1 GB to 16 GB.
Datalogger
5
/10/30/60/120/300/600 seconds
Sampling Time
or Auto. *
Default sampling time is 60 seconds.
*
The " Auto " sampling . means when the measuring value is changed ( > ± 1 %RH or > ±
1 ) will save the
data one time only.
Advanced
* SD
memory card Format
setting
* Set clock time ( Year/Month/Date, Hour/Minute/
Se
cond ) * Set sampling time * Set beeper sound ON/OFF * Set SD card Decimal character * Select the Temp. unit to or ℃℉ * Set RS232 data output ON/OFF
Update Time Approx. 1 second if measuring data of Display i
s changed.
Data Output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
*
Connect the optional USB cable USB-01 will get the USB plug.
Operating 0 to 50 . Temperature Operating Less than 85% R.H. Humidity Power Supply
*
A
Alkaline or heavy duty DC 1.5 V battery ( UM4, AAA ) x 6 PCs, or equivalent.
*
A
DC 9V adapter input. ( AC/DC power adapter is optional ).
Battery life
I
f use the new battery ( alkaline type ) and sampling time set to 60 seconds, the battery life will be > one month typically.
Weight 282 g/0.62 LB. Dimension 132 x 80 x 32 mm
( 5.2 x 3.1 x 1.3 inch )
Accessories Instruction manual...........................1 PC
Included
Hanging unit ( with sticker ).............
.
1 PC Optional SD Card ( 2 GB ). Accessories AC to DC 9V adapter.
USB cable, USB-01. RS232 cable, UPCB-02. Data Acquisition software, SW-U801-WIN.
2-2 Electrical Specifications (23±5 )
Humidity
Range 10 % to 95 % R.H. Resolution
0.1 % R.H.
Accuracy 70% RH :
± (3% reading + 1% RH).
< 70% RH :
± 3% RH.
Temperature
Range 0
to 50 ,32 to 122 .℃℃℉ ℉ Resolution 0.1 degree Accuracy - 0.8 .℃℃
- 1.5
.℉℉
@ Above specification tests under the environment RF Field Strength
less than 3 V/M & frequency less than 30 MHz only.
3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Display 3-2 Logger button, Enter button 3-3 button, Time button 3-4 button 3-5 SET button 3-6 Humidity/Temp. sensor 3-7 Hanging holes 3-8 Stand 3-9 Battery cover/Battery compartment 3-10 Screw of the battery cover 3-11 Reset button 3-12 RS-232 output terminal 3-13 SD card socket 3-14 DC 9V power adapter input socket 3-15 Hanging unit ( with sticker )
4. MEASURING PROCEDURE
1)Install the batteries into the battery compartment : * L
oose the " Screw of the battery cover " ( 3-10, Fig. 1 ) and take away the " Battery Cover " ( 3-9, Fig. 1 ) from the meter.
* Replace with DC 1.5 V battery ( UM4/AAA, Alkaline/Heavy
duty type ) x 6 PCs, and reinstate the cover.
* Make sure the battery cover is secured after changing
the battery.
2)The " Display " ( 3-1, Fig. 1 ) will show both the humidity and the temperature value that sensing from Humidity/Temp. sensor " ( 3-6, Fig. 1 ).
5. DATALOGGER
5-1 Preparation before execute datalogger function
a. Insert the SD card Prepare a " SD memory card " ( 1 GB to 16 GB, optional ), insert the SD card into the " SD card socket " ( 3-13, Fig. 1) with the correct direction exactly.
b. SD card Format If SD card just the first time use into the meter, it recommend to make the " SD card Format " at first, please refer chapter 7-1 ( page 11 ).
c. Time setting If the meter is used at first time, it should to adjust the clock time exactly, please refer chapter 7-2 ( page 11 ).
d. Decimal format setting
The numerical data structure of SD card is default used the " . " as the decimal, for example "20.6" "1000.53" . But in certain countries ( Europe ...) is used the " , " as the decimal point, for example " 20, 6 " "1000,53". Under such situation, it should change the Decimal character at first, details of setting the Decimal point, refer to Chapter
7-5, page 13. e. 3 Information of LCD display *If the Display show :
It means that the SD card exist the problem
CH- or the SD card memory is full, it should CArd change SD memory card.
* If the Display show :
It means that the battery is low voltage.
LobAt Under such condition, the Datalogger
function is disable.
* If the Display show :
It means that the SD card is not plugged
no into the meter. CArd
5-2 Datalogger
a. Start the datalogger
Press the " Logger button ( 3-2, Fig. 1 ) > 2 seconds continuously, until the Display show the indicator " DATALOGGER ", release the " Logger Button " ( 3-2, Fig. 1 ), then the measuring data along the time information will be saved into the memory circuit.
Remark :
*
How to set the sampling time, refer to Chapter 7-3, page 12.
*
How to set the beeper sound is enable, refer to Chapter 7-4, page 12.
c.. Finish the Datalogger During execute the Datalogger function ( Display show the
" Datalogger " indicator ), press the " Logger button " ( 3-2, Fig. 1 ) > 2 seconds continuously, until the Display indicator " DATALOGGER " is disappeared, release the " Logger Button " will finish the Datalogger function.
Before take away the SD card from the meter, it should execute the procedures of " Finish the Datalogger ", otherwise some existing recent save data may loss.
5-3 Check time information
Press " Time button " ( 3-3, Fig. 1 ) > 2 seconds continuously, the LCD display will present the time information of Year/Month/Date, Hour/Minute/Second and the sampling value.
5-4 SD Card Data structure
1)When the first time, the SD card is used into the meter, the SD card will generate a folder :
HTC01
2)If the first time to execute the Datalogger, under the route HTC01\, will generate a new file name HTC01001.XLS. After exist the Datalogger, then execute again, the data will save to the HTC01001.XLS until Data column reach to 30,000 columns, then will generate a new file, for example HTC01002.XLS
3)Under the folder HTC01\, if the total files more than 99 files, will generate anew route, such as
HTC02\ ........
4)
The file's route structure : HTC01\
HTC01001.XLS HTC01002.XLS
.....................
HTC01099.XLS
HTC02\
HTC02001.XLS HTC02002.XLS
.....................
HTC02099.XLS
HTCXX\
.....................
.....................
Remark : XX : Max. value is 10.
6. Saving data from the SD card to the computer ( EXCEL software )
1)After execute the Data Logger function, take away the SD card out from the " SD card socket " ( 3-13, Fig. 1 ).
2)Plug in the SD card into the Computer's SD card slot ( if your computer build in this installation ) or insert the SD card into the " SD card adapter ". then connect the " SD card adapter " into the computer.
3)
Power ON the computer and run the " EXCEL software ". Down load the saving data file ( for example the file name : HTA01001.XLS, HTA01002.XLS ) from the SD card to the computer. The saving data will present into the EXCEL software screen ( for example as following EXCEL data screens ) , then user can use those EXCEL data to make the further Data or Graphic analysis usefully.
EXCEL data screen
(
for example
)
EXCEL graphic screen ( for example )
7. ADVANCED SETTING
Under do not execute the Datalogger function, press the " SET button " ( 3-5, Fig. 1 ) > 2 seconds continuously will enter the " Setting " mode., then release the " SET button ". Following press the " SET button " (3-5, Fig. 1 ) once a while in sequence to select the seven main function, the display will show :
Sd F..... SD memory card Format
dAtE.....
.
Set clock time ( Year/Month/Date, Hour/Minute/ Second )
SP-t......Set sampling time
bEEP....
.
Set beeper sound ON/OFF
dEC......
.
Set SD card Decimal character
t-CF......Select the Temp. unit to or ℃℉
rS232...
.
Set RS232 data output ON/OFF
Remark : During execute the " Setting " function, if within 5 seconds , do not press any buttons further, the LCD Display will return to normal screen.
7-1 SD memory card Format
When the Display show " Sd F "
1)Use the " Button " ( 3-3, Fig. 1 ) or "
Button " (▲▼ 3-4, Fig. 1 ) to select the upper value to " yES " or " no ".
yES - Intend to format the SD memory card no - Not execute the SD memory card format
2)If select the upper to " yES ", press the " Enter Button " ( 3-2, Fig. 1 ) once again, the Display will show text " yES Enter " to confirm again, if make sure to do the SD memory card format, then press " Enter Button " once will format the SD memory clear all the existing data that already saving into the SD card.
7-2 Set clock time ( Year/Month/Date, Hour/Minute/ Second )
When the Display show " dAtE "
1)Use the " Button " ( 3-3, Fig. 1 ) or "
Button " ▲▼ ( 3-4, Fig. 1 ) to adjust the value ( Setting start from Year value ). After the desired value is set, press the " Enter button " ( 3-2, Fig. 1 ) once will going to next value adjustment ( for example, first setting value is Year then next to adjust Month, Date, Hour, Minute, Second value ).
Remark : The adjusted unit will be flashed.
2)After set all the time value ( Year, Month, Date, Hour, Minute, Second ), press the " SET button " ( 3-5, Fig. 1 ) once will save the time value, then the screen will jump to Sampling time " setting screen ( Chapter 7-3 ).
Remark : After the time value is setting, the internal clock will run precisely even Power off if the battery is under normal condition ( No low battery power ).
7-3 Set sampling time
When the Display show " SP-t "
1)Use the " Button " ( 3-3, Fig. 1 ) or "
Button " ▲▼
( 3-4, Fig. 1 ) to adjust the sampling value :
5 seconds, 10 seconds, 30 seconds, 60 second, 120 seconds, 300 seconds, 600 seconds Auto.
After the desired value is set, press the " Enter Button " ( 3-2, Fig. 1 ) to save the adjusting value with default.
Remark : The " Auto " sampling time means when the measuring value is changed ( > ±
1 %RH or > ± 1
) will save
the data to the memory circuit one time.
7-4 Set beeper sound ON/OFF
When the Display show " bEEP "
1)Use the " Button " ( 3-3, Fig. 1 ) or "
Button " ▲▼
( 3-4, Fig. 1 ) to select the data to " yES " or " no ".
yES - Meter's beep sound will be ON with default when save each data. no - Meter's beep sound will be OFF with default. when save each data.
2)
After select the upper text to " yES " or " no ", press the " Enter Button " ( 3-2, Fig. 1 ) will save the setting function with default.
7-5 Decimal point of SD card setting
When the Display show " dEC " The numerical data structure of SD card is used the " . "
as the decimal with default, for example "20.6" "1000.53" . But in certain countries ( Europe ...) is used the " , " as the decimal point, for example " 20,6 " "1000,53". Under such situation, it should change the Decimal character at first.
1)
Use the " Button " ( 3-3, Fig. 1 ) or "
Button " ▲▼ ( 3-4, Fig. 1 ) to select the upper text to " USA " or " Euro ".
USA - Use " . " as the Decimal point with default. Euro - Use " , " as the Decimal point with default.
2)After select the text to " USA " or " Euro ", press the " Enter Button " ( 3-2, Fig. 1 ) will save the setting function with default.
7-6 Select the Temp. unit to or ℃℉
When the Display show " t-CF "
1)Use the " Button " ( 3-3, Fig. 1 ) or "
Button " ▲▼ ( 3-4, Fig. 1 ) to select the upper Display text to " C " or " F ".
C - Temperature unit is F - Temperature unit is
2)After Display unit is selected to " C " or " F ", press the " Enter Button " ( 3-2, Fig. 1 ) will save the setting function with default.
7-7 Set RS232 data output ON/OFF
When the Display show " rS232 "
1)Use the " Button " ( 3-3, Fig. 1 ) or "
Button " ▲▼ ( 3-4, Fig. 1 ) to select the upper Display text to "yES " or " no ".
yES - RS-232 output terminal ( 3-12, Fig. 1 ) will send the RS232 signal output. no - RS-232 output terminal ( 3-12, Fig. 1 ) will not send the RS232 signal output.
2)After Display text is selected to " yES " or " no ", press the " Enter Button " ( 3-2, Fig. 1 ) will save the setting function with default.
8. POWER SUPPLY from DC ADAPTER
The meter also can supply the power supply from the DC 9V Power Adapter ( optional ). Insert the plug of Power Adapter into " DC 9V Power Adapter Input Socket " ( 3-14, Fig. 1 ).
9. BATTERY REPLACEMENT
1)When the left corner of LCD display show " ", it
is necessary to replace the battery. However, in-spec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate.
2)
Loose the " Screw of the battery cover " ( 3-10, Fig. 1 ) and take away the " Battery Cover " ( 3-9, Fig. 1 ) from the instrument and remove the battery.
3)Replace with DC 1.5 V battery ( UM4/AAA, Alkaline/heavy duty ) x 6 PCs, and reinstate the cover.
4)
Make sure the battery cover is secured after changing the battery.
10. SYSTEM RESET
If the meter happen the troubles such as :
CPU system is hold ( for example, the key button can not be operated... ).
Then make the system RESET will fix the problem. The system RESET procedures will be either following method :
During the power on, use a pin to press the " Reset Button " ( 3-11, Fig. 1 ) once a while will reset the circuit system.
11. RS232 PC SERIAL INTERFACE
The instrument has RS232 PC serial interface via a 3.5 mm terminal ( 3-12, Fig. 1 ) if the RS232 function already select to " ON ", refer to chapter 7-7, page 14.
The data output is a 16 digit stream which can be utilized for user's specific application.
A RS232 lead with the following connection will be required to link the instrument with the PC serial port.
Meter PC
(9W 'D" Connector)
Center Pin..........................Pin 4
(3.5 mm jack plug)
Ground/shield.......................Pin 2
2.2 K resistor
Pin 5
The 16 digits data stream will be displayed in the following format :
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
Each digit indicates the following status :
D0 End Word D1 & D8 Display reading, D1 = LSD, D8 = MSD
For example :
If the display reading is 1234, then D8 to D1 is : 00001234
D9 Decimal Point(DP), position from right to the
left 0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP
D10 Polarity
0 = Positive
1 = Negative
D11 & D12 Annunciator for Display
= 01 = 02 % RH = 04
D13 When send the upper display data = 1
When send the lower display data = 2 D14 4 D15
S
tart Word
RS232 FORMAT : 9600, N, 8, 1
Baud rate 9600 Parity No parity Data bit no.
8
Data bits
Stop bit 1 Stop bit
12. PATENT
The meter ( SD card structure ) already get patent or patent pending in following countries :
Germany Nr. 20 2008 016 337.4 JAPAN 3151214 TAIWAN M 358970
M 359043
CHINA ZL 2008 2 0189918.5
ZL 2008 2 0189917.0
USA Patent pending
Loading...