PCE Instruments PCE-HPT 1 Users guide

Page 1
Manual
Data Logger
PCE-HPT 1
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@industrial-needs.com
Page 2
CONTENTS
TITLE PAGE
1. Introduction………………………………………………………………….……………. 1
2. Specifications……………………………………………………………………………...
3. Symbol Definition and Button Location………......................................................
4. Operation Instructions……………………….…………………..................................
4.1 Power-Up……………...........................................................................................3
4.2 Connection the Temperature Probe………..........................................................
4.3 Selecting the Temperature Scale……………..……………………………………..
4.4 Data-Hold Operation…………………………………………………………………..3
4.5 Back light Operation………………………………………………………………….. 3
4.6 Relative Operation……………………………………………………………............
4.7 Record Operation………………………………………………………….................
4.8 MAX/MIN Operation………………………….……………………………................
4.9 Auto Power Off…………………………………………………………………………
4.10 Low Battery Condition………………………………………..... …………………..
5. Temperature Measurement……………………………………....... ………………….. 4
6. Setting the Time…………………………………………………………........................
7. Changing the Logging Interval…………………………………………………………
8. Clearing Memory………………………………………………………………………….
9. Temperature Meter Calibration Setup ……….………………………………………..
10. Communicating with a PC……………………………………………………………..
Testlink PCE-HPT 1 Software……………………………………………………………
11. Power Preparation……………………………………………………………………..
12. Maintenance .…….…………………………………………………………………….
13. Temperature Probe.……………………………………………………………..........
1
2
3
3
3
3 3 3
4
4
5
5
5
6
7
7
12
12
12
Page 3
PCE-HPT 1 THERMOME TER
1. INSTRUCTION
This instrument is a digital thermometer for use with platinum-type temperature sensor. Temperature indication follows IEC751 temperature table for PT-type sensor.
2. SPECIFICA TIONS
Numerical Display: 5 digital liquid crystal displays Measurement Range: -100°C ~ 400°C; -148°F ~ 752°F Resolution: 0.01°C; 0.02°F; Sensor types:
Platinum resistance temperature sensor for pt-100 4 wires. ALPHA=0.00385
Environmental:
Operating Temperature and Humidity: 0°C ~50°C (32°F ~ 122°F) ; 0 ~ 80% RH
Storage Temperature:
-10°C to 60°C (14°F ~ 140°F); 0 ~ 80% RH
Altitude up to 2000 meters.
Accuracy: at ( 23 ± 5°C )
Range Accuracy
-100°C ~ 400°C ±(0.05% reading + 0.1°C)
-148°F ~ 752°F ±(0.05% reading + 0.2°F)
Temperature Coefficient:
For ambient temperatures from 0°C ~ 18°C and 28°C ~ 50°C, for each °C ambient below 18°C or above 28°C add the following tolerance into the accuracy spec.
0.005% of reading + 0.01°C ( 0.005% of reading + 0.02°F )
Note:
The basic accuracy Specification does not include the error of the probe pl ease refer to the probe accuracy specification for additional details.
Sample Rate: 2 times per second Dimension: 185 x 65 x 36 mm(meter only) Weight: 360g Approx. Power requirement:
9V Battery;
AC adapter: 9V DC(7~10V Max.)/20mA Min (Plug Diameter: 3.5mmx1.35mm)
Battery Life: Approx. 100hours Standar d A cce ssory :
Pt-100 Probe(class A), Instruction manual, 9V Battery, windows software, carrying case, USB cable.
Optional Acce ssor ies : AC adapter, RS-232 Cable.
1
Page 4
3. SYMBOL DEFINITION & BUTTON LOCATION
MIN : The Minimum value is now being displayed
MAX
HOLD : This indicates that the display data is being hold.
REC : Readings are being logged. REL : The reading is now under Relative Mode.
°C °F : Centigrade and Fahrenheit indication.
- : This indicates that the minus temperature is sensed.
h:m
: The Battery is not sufficient for proper operation.
: The Maximum value is now being displayed
: This indicates Auto Power Off is enabled.
: hours; minute
PCE-HPT 1 THERMO METER
○1 Pt type temperature sensor connector ○7 HOLD button
○2 LCD display ○8 °C , °F control button
3
Power ON/OFF and Back light button
4
Relative readout button
5
REC button
6
MAX MIN control button
9
PC Interface
10
External DC 9V power supply jack
11
Tilt stand
12
Battery Compartment
2
Page 5
PCE-HPT 1 THERMOME TER
4. OPERATION INSTRUCTIONS
4.1 Power-Up
Press the “ to OFF.
” key to turn ON the thermometer and Press and hold “
4.2 Connection the Temperature Probe
For measurement, plug the temperature probe into the input connectors.
4.3 Selecting the Temperature Scale
When the meter was first power on, the default scale setting is set at Celsius (°C) scale. The user may change it to Fahrenheit (°F) by pressing
default scale.
button and vice versa to Celsius and change
4.4 Data-Hold Operation
The user may hold the present reading and keep it on the display by pressing the When the hold data is no longer needed, one may release the data-hold operation by pressing
button again.
When the meter is under Data Hold operation, the
, and
4.5 Back light Operation:
Press the button will turn back light on and Press it once again will turn off. The meter will turn back light off if there is no push
button for 30 seconds.
4.6 Relative Operation:
When one press the button, the meter will memorize the present reading and the difference between the new reading and the memorized data will be shown on the display. Press the button again to exit the Relative operation.
4.7 Record Operation:
Starting and Stopping Logging Setup, memory clear, and PC communications are inaccessible
during logging. Set the logging interval. (See “Changing the Logging Interval.”) Press
Press
button to start logging. The display shows “REC”. button again to stop logging.
4.8 MAX/MIN Operation:
When one press the button the meter will enter the MAXMIN mode. Under this mode the
maximum value, minimum value is kept in the memory simultaneously and updated with every new
data.
When the MAX symbol is display, the Maximum is shown on the display.
3
” buttons for 3 seconds
button are disabled.
button.
Page 6
Press
Press
updated in the memory and the reading is the present temperature.
One may press
When the meter is under MAXMIN operation,
To exit the MAX/MIN mode, one may press and hold
button again, then the MIN symbol is on the display and also the minimum reading. button again, MAX and MIN will blink together. This means that all these data is
to circulate the display mode among these options.
and button are disabled.
button for two seconds.
PCE-HPT 1 THERMOME TER
4.9 Auto Power Off:
By default, when the meter is powered on, it is under auto power off mode. The meter will power
itself off after 30 minutes if no key operation.
One may press and hold
successive beeps to indicate that auto power off is disabled.
button and then power on the meter and there will be two
4.10 Low Battery Condition:
The temperature meter low battery indication as follows:
Low battery. Replace the batteries.
5. TEMPERATURE MEASUREMENT
5.1 Correct Measurement Method:
The temperature sensor is located at the end of the metal sheath of the sheath type TEMPERATURE PROBE. To accurately test internal temperature insert the probe into the item you want to measure to a distance at least 15 times the diameter of the sheath.
5.2 Connector Configuration:
4
Page 7
6. SETTING THE TIME
PCE-HPT 1 THERMOME TER
6.1 Press and hold
button and then power on the meter to enter setup mode.
6.2 Press button to enter Time setting mode. The right two digits blink.
6.3 Press or button until the display shows the correct year, and then press button
to select. The left two digits blink.
6.4 Press or button until the display shows the correct month, and then press
button to select. The right two digits blink.
6.5 Press or button until the display shows the correct day, and then press
button to select. The left two digits blink.
6.6 Press or button until the display shows the correct hour (24-hour format), and then
press
button to select. The right two digits blink.
6.7 Press or button until the display shows the correct minutes, and then press
button to store the time in memory.
Note:
Holding down “REC” or “°C/°F” causes the number to change more quickly.
7. CHANGING THE LOGGING INTERVAL
The logging interval determines how often the thermometer stores logged readings in memory.
7.1 Press and hold
7.2 Press
7.3 Press or
press
button to select. The right two digits blink.
7.4 Press or
button to store the time in memory.
button and then power on the meter to enter setup mode.
button to enter Interval setting mode. The left two digits blink.
button until the display shows the correct hour (24-hour format), and then
button until the display shows the correct minutes, and then press
Note:
Holding down “REC” or “°C/°F” causes the number to change more quickly.
8. CLEARING MEMORY
When memory is full, REC appears and blinks on the display and logging stops.
You can clear memory in next power on the meter to enter clear memory mode.
Press and hold logged readings from memory. The display shows the number from 5 decreases to 0.
button and then power on the meter to enter clear memory mode to delete
5
Page 8
PCE-HPT 1 THERMOME TER
9. TEMPERATURE METER CALIBRATION SETUP
Below table diagram shows each button function when user enter into calibration mode.
Note:
Tu rn the Power “OFF” before attempting following SETUP. Setup mode is cancelled during below procedure if “POWER” button is pressed.
9.1 Temperature Calibration
Place the temperature probe in a known, stable temperature environment. Allow the readings to stabilize. In Setup change the offset until the display reading matches the calibration temperature.
Press and hold
Press
Press
Press
Press Note: To abort during the process, press
button to enter calibration mode.(in 3 seconds)
button to enter calibration mode. (in 3 seconds)
or button to confirm present Temperature value.
9.2 Recall Default factory setting value
+
buttons and then power on the meter to enter setup mode.
button twice to confirm selection.
button to exit calibration mode.
Press and hold
Press
Press
+ buttons and then power on the meter to enter setup mode.
button to enter calibration mode. (in 3 seconds)
button to enter recall mode. (in 3 seconds)
6
Page 9
PCE-HPT 1 THERMOME TER
Press
Press Note: To abort during the process, press
button to confirm revert back to “Default factory setting value”
button to confirm selection.
button to exit calibration mode.
10. COMMUNICATION WITH A PC
Users can transfer data from the built-in memory on the instrument to a PC through PCE-HPT 1 software. The communication requires a USB or RS-232 serial connection.
TESTLINK PCE-HPT 1 SOFTW ARE
(1)The PCE-HPT 1 package contains:
80mm CD
Custom designed USB cable for PCE-HPT 1
(2)System Required:
Windows NT 4.0/ NT2000/ XP/ VISTA/ Windows 7
(3)Minimum Hardware Required:
PC or NoteBook with Pentium 800MHz or higher, 128 MB RAM
At least 50 MB hard disk space available to install PCE-HPT 1
Recommended screen resolution 1024X768 or above
(4) Install PCE-HPT 1 and USB-120 connector driver:
1. We recommend close all other application before installing PCE-HPT 1.
2. Insert setup CD disk to CD disk drive to display install screen. You may also run
MainSetup.exe in the directory of the CD.
3. Click Install to begin installation.
4. It will install USB-120 connector driver first:
5. While installing, it will show this window below, just click “next” to continue.(see Fig.1)
6. Select “Launch the CP210x VCP Driver Installer” option, and then click Finish. (see Fig.2)
(Fig.1) (Fig.2)
7
Page 10
PCE-HPT 1 THERMOME TER
7. Click Install.
8. After finish installing USB-120 connector driver, it
will install PCE-HPT 1 software automatically
copy PCE-HPT 1.exe
to your hard disk ( default is c:\program
files\PCE-HPT 1.
9. After finish installation, plug USB-120 connector
to PC usb port, execute.
10. ”start”My Computer”, then choose “View
System Information” on the left top of the window,
the window below will show up.
11. Choose “Hardware” option and click “Device Manager” button, click “+” symbol on the left side of Ports(COM &LPT), if the device “CP2101 USB to UART Bridge Controller(COMx)” is in the list, the connector is ready to work.
(executable file) and help file
. it will
(5)Main menu and buttons:
Open - Retrieve files from the disk
Save - Save the present data to the disk
Print - Send data in the present table to the printer
Pause - Stop data recording
8
Page 11
PCE-HPT 1 THERMOMETER
Run - Start data recording Output To Graph - Send tabular data to another graph
New - Reset all the data
ption - Setup dialog to set attributions of graph. (You can also double click on the graph.)
O Sampling Rate - Time interval between each data to be recorded. If you want to change it,
move mouse cursor to the digit you want to change and click, then input the new sampling rate. The change will be effective immediately. It will keep up to 5000 data points, when data points exceed this limit, the oldest 100 points will be replaced sequentially.
(6)Real Time Graph:
You can Zoom this graph by using mouse:
To Zoom:
1. Press and hold the Shift key
2. Press the left mouse button and drag the cursor to select the new extents
3. Release the mouse button
To Undo the Zoom:
Press the Alt+U key or click Undo Zoom button Note: Zooming method is not allowed in Real Time Graph Window.
9
Page 12
PCE-HPT 1 THERMOMETER
(7)Tabular:
The Tabular window can be used to record real time data in a table format. The maximum number of records that the Tabular window can keep will be depending on how many available memory and hard disk space of the connected computer.
(8)Data Logger
When you have thermometer connected to computer, select "Load Data" to start loading the recorded data from the thermometer. There will be a progress indicator to show the loading progress.
If error occurs, just click "Load Data" again. After the data has been successfully loaded to computer, the left side window shows how many
data sets were loaded and their detailed information (start date, start time, recording rate, and record numbers).
For example:
10
Page 13
PCE-HPT 1 THERMOMETER
It will transfer the first data set to graph and tabular on the right side window once you finish loading recorded data from the thermometer. You can click on at any data set to show its graph and tabular on the right side window.
You can choose a rectangle area on the graph to zoom in for detail. The vertical dash line in the graph will match the highlight row in the tabular. When clicking on
another row in the tabular, the vertical dash line will move to the corresponding position to match the time.
(9)Frequently Asked Question:
Q: I have connected thermometer to computer serial port and turned thermome ter o n, but it still
shows "NO CONNECTION" ?
A: It could be caused by that all serial port are occupied by other applications. Close all
application, restart your computer, and run PCE-HPT 1 again.
Q: In TABULAR window, I saved a file. Can I use EXCEL to open this file? A: If the decimal separator is comma (,) in yo ur area, you cannot use CSV file because CSV
file use comma to separate data. This will cause confusion (for example 23,6,C,24.6,C). However, you can use TXT files instead. It uses tab to separate to data. (For example: 23.6 C 24.6 C) and it can be accepted in EXCEL.
Q: How to uninstall PCE-HPT 1? A:
Uninstall PCE-HPT 1 by launching the Add/Remove Programs applet out of the Control Panel, highlighting the PCE-HPT 1, and clicking on the Add/Remove... button, then it will remove the PCE-HPT 1 folder and files from your computer.
11
Page 14
PCE-HPT 1 THERMOME TER
11. POWER PREPARATION
11.1 Battery Loading
Remove the battery cover on the back and insert one 9V battery.
11.2 Battery Replacement
When the battery voltage drops below the operating voltage, Low battery indicator
9 Volt battery immediately to ensure the unit functions properly.
will appear. Replace a
11.3 A C Adapter Connection
When the AC adapter is used, insert the plugs of the adapter into the DC9V connector on the side panel.
Note:
When the AC adapter is connected while battery is in serted, the unit will be powered from the adapter (the AC adapter has priority).
12. Maintenance
In order to ensure the accuracy of the thermometer for a longer period of time you should calibrate it once a year.
Clean the device and the window of the display with a clean, lint-free, antistatic and dry cleaning cloth.
Do no use cleaning agents that conta in ca rbo n or benzenes, alcohol or anything similar to clean
the product since these substances damage the surface of the measuring instrument. Moreover, these fumes are hazardous to health and explosive. Do not use tools with sharp edges, screwdrivers, metal brushes or anything similar to clean the device.
13. Temperature Probe
13.1 Piercing type temperature probe.
13.2 Piercing type temperature probe Specification:
Sensor Type Platinum resistance thermometer sensor Pt 100(4 wires)
Accuracy IEC751, class A (t: measurement temperature)
Measurement Range -100 to 400°C
Temperature Sensor Dimensions Approx. ∅5.0mm(∅0.2”)
Temperature Sensor Length Approx. 230mm(9.05”)
Cable Length Approx. 1500mm(59.0”)
12
Loading...