PCE Instruments PCE-GMM 10 Users guide

Page 1
© PCE Instruments
PCE-GMM 10 Grain Moisture Meter
User Manual
Last change: 11 July 2024
v1.2
English
Page 2
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Specifications ........................................................................................ 2
3 Meter Overview ...................................................................................... 3
4 Operation Instructions ......................................................................... 3
5 Moisture Value Correction ................................................................... 4
6 Maintenance .......................................................................................... 4
7 Contact ................................................................................................... 5
8 Disposal ................................................................................................. 5
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
• The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
• The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
• Do not expose the device to shocks or strong vibrations.
• The case should only be opened by qualified PCE Instruments personnel.
• Never use the instrument when your hands are wet.
• You must not make any technical changes to the device.
• The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
• The device must only be used with accessories from PCE Instruments or equivalent.
• Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
• Do not use the instrument in explosive atmospheres.
• The measurement range as stated in the specifications must not be exceeded under
any circumstances.
• Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business.
Page 4
© PCE Instruments
2
2 Specifications
Cereal
Measuring range
Resolution
Accuracy
Wheat
9 ... 38%
0.1%
± 0.5%
Corn
9 ... 39%
0.1%
± 0.5%
Japonica rice
8.5 ... 40%
0.1%
± 0.5%
Indian rice
8.9 ... 30.4%
0.1%
± 0.5%
Soybeans
8.9 ... 33.4%
0.1%
± 0.5%
Rice
10.4 ... 26.4%
0.1%
± 0.5%
Sorghum
8 ... 35%
0.1%
± 0.5%
Rapeseed
6.4 ... 25.4%
0.1%
± 0.5%
Millet
9.4 ... 28.4%
0.1%
± 0.5%
Peanuts
5.4 ... 18.9%
0.1%
± 0.5%
Barley
9.4 ... 26.4%
0.1%
± 0.5%
Sunflower seeds
7.9 ... 24.4%
0.1%
± 0.5%
Coffee beans
10 ... 30%
0.1%
± 0.5%
Cocoa beans
4.5 ... 17%
0.1%
± 0.5%
Parchment Coffee
8.8 … 40%
0,1%
± 0.5%
Sesame
6 ... 18%
0.1%
± 0.5%
Flaxseed
4.5 … 18.0%
0.1%
± 0.5%
Almonds
4.5 … 21.0 %
0.1%
± 0.5%
Cashew
4,5 ... 15,0%
0.1%
± 0.5%
Jute Seed
6.6 … 32 %
0.1%
± 0.5%
Raspberry Seed
9.5 … 32 %
0.1%
± 0.5%
Red Bean (small)
12.1 … 30 %
0.1%
± 0.5%
Repeatability
0.2%
Adjustment range
± 9.9%
Sample size
About 65 ml
Operating temperature range
0 ... 40°C / 32 ... 104°F
Temperature compensation
Automatically
Power supply
9V block battery
Automatic shutdown
After 3 minutes
Dimensions
160 x 95 x 125 mm
Weight
823 g
Page 5
© PCE Instruments
3
3 Meter Overview
1
Cover
2
Measuring Cup
3
Display
4
Operation Buttons
4 Operation Instructions
1. Press the power button to turn the meter on.
2. Press the set button; the meter will now display “Select kind” and “Adjust moisture”.
3. Press set again to select “Select kind”
4. Use the + and – buttons to navigate the menu
5. Press set to select the desired grain type; the meter will now return to measurement mode.
Important!
6. Fill the measuring cup ½ full with grain. Gently shake the meter to settle the grains. Full the measuring cup to the top.
7. Gently press the cover down during measurement to ensure accurate results. If the grains settle further after pressing the cover down, refill again to the top and measure again.
8. Remove the cover and replace the sample grains with a new sample.
9. Pressing the set button after 2 or more measurement will display the average value of the measurement results.
Using the + and – buttons in measurement mode will adjust the display brightness. The meter will display “LOW” of the battery runs low.
Page 6
© PCE Instruments
4
5 Moisture Value Correction
Depending on the environment, a grain may have varied moisture. This can be adjusted for each grain type individually.
1. Press the set button; the meter will now display “Select kind” and “Adjust moisture”.
2. Press set again to select “Select kind
3. Use the + or – button to navigate the menu
4. Press set to select the desired grain type; the meter will now return to measurement mode.
5. Press set again, but this time select “Adjust moisture”
6. Use the + and – buttons to adjust the moisture value.
7. Press and hold the set button to save the value and return to the measurement mode.
6 Maintenance
• Before use, please place the grains and the meter in the same location and under the same temperature to ensure measurement accuracy.
• Handle the meter with care.
• Ensure the battery is in good condition. Battery leakage can cause damage to the
meter.
• Use the provided brush to gently clean the measuring cup after use.
Page 7
© PCE Instruments
5
7 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
8 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
Page 8
© PCE Instruments
6
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 26 23, rue de Strasbourg Calle Mula, 8 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 [email protected] [email protected] [email protected] www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Trafford House Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Chester Rd, Old Trafford 55010 Loc. Gragnano Pehlivan Sok. No.6/C Manchester M32 0RS Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom Italia Türkiye Tel: +44 (0) 161 464902 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 161 464902 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 [email protected] [email protected] [email protected] www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands United States of America Denmark
PCE Brookhuis B.V. PCE Americas Inc. PCE Instruments Denmark ApS Institutenweg 15 1201 Jupiter Park Drive, Suite 8 Birk Centerpark 40 7521 PH Enschede Jupiter / Palm Beach 7400 Herning Nederland 33458 FL Denmark Telefoon: +31 (0)53 737 01 92 USA Tel.: +45 70 30 53 08 [email protected] Tel: +1 (561) 320-9162 [email protected] www.pce-instruments.com/dutch Fax: +1 (561) 320-9176 www.pce-instruments.com/dansk [email protected] www.pce-instruments.com/us
Loading...