PCE Instruments PCE-DDM 20WI-ICA, PCE-DDM 3WI-ICA, PCE-DDM 5WI-ICA, PCE-DDM 10WI-ICA, PCE-DDM 3-ICA Users guide

...
Page 1
PCE Americas Inc.
PCE Instruments UK Ltd.
www.pce-instruments.com/english
www.pce-instruments.com
Manual
Crane Scales PCE-DDM seri es
Date of last change: 07.01.2015
711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561 ) 320 -9176 info@pce-americas.com
Southpoint Business Park
Hampshire / Southampton
United Kingdom, SO31 4RF
From Outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 23 80 987 03 9
info@pce-instruments.com
Units 12/13 Ensign way
Version 1.0
Date of creation: 15/12/2014
Page 2
Contents
1 Introduction ............................................................................................................. 3
2 Safety notes ............................................................................................................. 3
2.1 General ....................................................................................................................................... 3
2.2 Maintenance and inspection ....................................................................................................... 4
3 Specifications .......................................................................................................... 5
4 System description ................................................................................................. 6
5 Instructions .............................................................................................................. 7
5.1 Display and keys ........................................................................................................................ 7
5.1.1 LCD display .................................................................................................................................... 7
5.1.2 Keypad ........................................................................................................................................... 7
5.2 Wireless hand-held display unit .................................................................................................. 8
5.3 Function guide ............................................................................................................................ 9
5.3.1 ON / OFF ........................................................................................................................................ 9
5.3.2 Zero ................................................................................................................................................ 9
5.3.3 TARE .............................................................................................................................................. 9
5.3.4 PEAK HOLD ................................................................................................................................... 9
5.3.5 Data memory .................................................................................................................................. 9
5.3.6 Data search .................................................................................................................................... 9
5.3.7 Delete memory ............................................................................................................................. 10
5.3.8 Battery voltage ............................................................................................................................. 10
5.3.9 To change the unit ....................................................................................................................... 10
5.3.10 To return to measurement mode ................................................................................................. 10
5.4 Parameter selection and calibration ......................................................................................... 10
5.4.1 Key functions ................................................................................................................................ 10
5.4.2 Parameter settings ....................................................................................................................... 10
5.4.3 Calibration .................................................................................................................................... 12
5.5 Display explanations ................................................................................................................. 12
5.6 Troubleshooting ........................................................................................................................ 13
6 Disposal ................................................................................................................. 14
7 Contact ................................................................................................................... 14
7.1 PCE Instruments UK ................................................................................................................ 14
7.2 PCE Americas .......................................................................................................................... 14
Page 3
Manual

1 Introduction

Thank you for purchasing PCE-DDM series crane scales from PCE Instruments. These crane scales which are made of high-quality materials are perfectly suitable for mobile tension measurements, e. g. as carried out by consultants. They have a high measurement capacity but are also compactly constructed with a low net weight.

2 Safety notes

2.1 General

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no warranty of damage or injuries caused by non-observance of the manual.
- The device may only be used in approved temperature ranges as laid down in the specifications. Exposure to extreme temperatures, direct sunlight, extreme atmospheric humidity or wetness (e. g. wet hands) must be avoided.
- The case must only be opened by qualified personnel of PCE Instruments.
- The instrument should never be placed with the user interface facing an objec t (e.g. keyboard side on a table).
- You should not make any technical changes to the device.
- The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner, no abrasives or solvents.
- If you do not use the device for a longer period of time, remove the batteries.
- The device may only be used with PCE access or ies or equival ent.
- Do not use the device in potentially explosive atmospheres.
- Do not weigh more than the maximum capacity.
- To avoid hazards arising from load lifting, the producer as well as the user have to comply with certain duties. The use of the measuring equipment may at no time be hazardous.
- The person responsible for the measuring equipment as well as the user must observe and fulfill the national regulations, e. g. regulations for accident prevention, safety regulations, work protection regulations and all other regulations applicable for the use of the measuring eq uip ment.
- Other directives such as regulations and safety information for the use of the measuring equipment must be borne in mind, for example those of the crane producer, of the load suspension device producer and of the shackle producer.
- In this relation, the measurement equipment may only be mounted, put into service, maintained and operated by qualified personnel using appropriate protective equipment.
- The measuring equipment must not be changed and may only be used for intended purposes.
- The measuring equipment as well as all other equipment (e. g. the crane, the load suspension devices etc.) must be maintained, serviced and accordingly recorded regularly. Before each use of this equipment, you should at least visually inspect it. In case the equipment is incomplete or damaged (e. g. cracks, deformations, split-offs) the equipment must be taken out of service. It is urgently necessary to get advice from your company’s responsible safety representative regarding this matter.
- Repairs may only be carried out by qualified personnel and only quality-tested spare parts must be used. All repairs, maintenance work and spare parts must be documented by the service partner.
- The manual as well as the safety notes should always be with the measuring equipment.
- The measuring equipment is not ex-protected and may not be used in potentially explosive atmospheres. The environmental conditions such as the temperature ranges can be seen from the manual and must be adhered to. Aggressive or corrosive areas of application must be avoided. When the temperature fluctuates severely, an acclimatization period must be included.
- The measuring equipment is only approved for lifting and weighing freely-moveable loads. Torsion (torsional stress) of the load is not allowed. Carrying persons, pulling, tearing, towing etc. of loads is prohibited.
- The permissible nominal load [MAX] of the measuring equipment and other equipment in use (e. g. crane, lifting fixation device etc.) may under no circumstances be exceeded.
- When you use the equipment, you must always observe the possible danger zone. Do not enter the danger zone during use. This does not only include the area directly under the load but also the areas which can be dangerous due to e. g. swinging ropes or other load suspension devices.
3
Page 4
Manual
Every 3 months or 12500 measurements,
- Control the wear and tear of the attachment
- Make sure that all parts work properly.
Every 12 months or 50000 measurements,
- Inspect all load-bearing parts, e. g. check for by qualified personnel.
Every 5 years or 250000 measurements, whatever happens first.
- All load-bearing parts must be replaced.
Every 10 years or 500000 measurem ents , whatever happens first.
- Service life of the equipment is over. Equipment must be replaced.
This manual is published b y PCE Instruments without any guarantee. We expressly refer to our general guarantee terms, they can be found in our general terms of business. If you have any questions please contact PCE Instruments.

2.2 Maintenance and inspection

- Inspection ahead of each use of the measuring equipment
When inspecting the equipment before starting work, the user must make sure that
- there are no visible deformations or other damage such as cracks,
- all attachment parts are complete and in good condition (e. g. safety splits etc.)
- the existing complete system does not inherit any hazards (e. g. faulty mounting etc.)
- the environment does not inherit any hazards and if so, that counter measures are taken.
- Regular inspection / maintenance
whatever happens first.
whatever happens first.
Only the owner or user is responsible for damage and injuries resulting from improper use or non­observance of the regulations. The producer assumes no liability for improper use. The safety notes are extracts from the valid norms and regulations along with some notes and tips. These do not replace the valid regulations and norms but must be seen as assistance for safe use of the equipment. Please read the valid national norms and regulations.
If you have any questions, please contact PCE.
parts.
- Control all dimensions.
- Consider all possible deformations and damage.
hairline cracks etc. Have maintenance carried out
4
Page 5
accuracy
± 0,1 % of measurement range
taring range
max. 20 % of measurement range
display
25 mm (1 ”), 5 digits, LCD with 22 mm digit height
unit of measurement
kg / t / lbs / N / kN
wireless range
approx. 80 m
sampling rate
2.5 Hz
operating conditions
-10 ... +40 °C, ≤ 85 % RH
power supply
3 x 1.5 V AA batteries
operation time
approx. 50 h
battery life
≤ 40 hours
model
range
resolution
minimum load
weight
with shackle
3000 kg / 30 kN
5000 kg / 50 kN
10000 kg / 100 kN
20000 kg / 200 kN
50000 kg / 500 kN

3 Specifications

Manual
PCE-DDM 3 PCE-DDM 5 PCE-DDM 10 PCE-DDM 20 PCE-DDM 50
Delivery contents
1 x crane scales PCE-DDM 1 x hand-held display unit 2 x shackle 1 x carrying case + batteries and manual
1 kg / 10 N 10 kg 2 kg 5 kg 2 kg / 20 N 40 kg 3 kg 6 kg 5 kg / 50 N 100 kg 11 kg 25 kg 10 kg / 100 N 200 kg 18 kg 49 kg 20 kg / 200 N 400 kg 39 kg 128 kg
5
Page 6
Model
A
(mm)
B (mm)
C (mm)
D (mm)
Ø (mm)
H (mm)
Material
PCE-DDM 3
260
123
37
195
51
365
aluminium
PCE-DDM 5
285
123
57
210
58
405
aluminium
PCE-DDM 10
320
120
57
230
92
535
steel
PCE-DDM 20
375
128
74
260
127
660
steel
PCE-DDM 50
465
150
104
305
184
930
steel

4 System description

Manual
6
Page 7
Manual

5 Instructions

5.1 Display and keys

5.1.1 LCD display

a) 25 mm (1“) 5-digit LCD display with all functions and units b)
: Wireless connection signal. Symbol means that the signal is stable. It disappears when no signal is
received and it flashes when the signal is weak .
battery indication. : full, : low, : flat.
c) d) PEAK: current value is the maximum value. e) MEM: appears once when the value is saved in the parameter or calibration memory. When it appears for a longer period of time, the values are saved in the data memory. f) STB: stable condition. g) kN: “kilonewton”, N: “newton”, in taring mode the “N” flashes. h) t: “tonne”. i) lb: “lbs”. k) kg: “kilogrammes”.

5.1.2 Keypad

a) ON / OFF
1. Press the “ON / OFF” key to s witc h the de vice on.
2. When the device is switched on, press the “ON / OFF” key for 3 seconds to switch the device off. b) ZERO: When the device is switched on without any load attached to the hook and the display still shows numbers, press this key to set the device to 0. c) UNIT: Press the “UNIT” key to change the unit: “kg” → “lb” → “N” → “kN” → “t” → “kg”. d) PEAK: When you attach a new weight and press the PEAK key, the device will show the maximum value of this new weight and freezes it into the display. By pressing the key again, you return to normal measurement.
7
Page 8

5.2 Wireless hand-held display unit

Manual
1) “Zero” a) When the device is switched on without any load attached to the hook and the display still shows numbers, press this key to set the device to 0. b) In the settings this key is used as the up key.
2) “Tare” a) Attach a loop or a container to the hook and press this key when the device displays a stable value. The display will now show “0” and “N” flashes. b) Pour the products into the container. The device will now show the net weight of the product. c) When you remove the products and the container from the hook, the device will display negative values. d) In the settings this key is used to switch between the digits.
3) “Mode” Press “MODE” to switch the backlight off and “ENTER” to confirm this. Press “MODE” twice to get to the setup and “ENTER” to get to the parameter settings. Press “MODE” to return to measurement mode. Press “MODE” 3 times. The display will show “dC”. Then press the “ENTER” key to check the battery level. Press “MODE” to return to measurement mode. Press “MODE” 4 times. The display will show “Unit”. Then press “ENTER” to get to the mode in which you can select the unit. Press “Zero” to select the unit and “Mode” to return to measurement mode. Press “MODE” 5 times. The display will show “ACCU”. Then press “ENTER” to check the memory status. Press “MODE” to return to measurement mode. Press “MODE” 6 times. The display will show “SACCU”. Press “ENTER” to search within the memory. Press “MODE” to return to measurement mode. Press “MODE” 7 times. The display will show “CLEAr”. Press “ENTER” to delete the memory. Press “MODE” to return to measurement mode. Press “MODE” 8 times. The display will show “CLIBr”. Press “ENTER” and hold it for 3 seconds to check the calibration process. Press “ENTER” and hold I for fewer than 3 seconds to return to measurement mode. Press “MODE” 9 times. The display will show “ESC”. Press “ENTER” and “Peak” to return to the default settings.
4) “Enter” Is used to select a function, normally in combination with the “MODE” key.
5) “Peak” When you attach a new weight and press the PEAK key, the device will show the maximum value of this new weight and freezes it into the display. By pressing the key again, you return to normal measurement.
8
Page 9
Manual
OPERATION
DISPLAY
Description
ON / OFF
displayed twice, self-diagnostic
programme
displayed twice, shows capacity
current battery voltage is 3.98 V
current software version
stabilisation
capacity (5 t in this case)
1
manual switch-off
Press the “ON / OFF” key for 3 seconds.
2
remote switch-off
Press the “MODE” key on the hand-held display unit to select “Power Off
and hold “Enter” to confirm and switch off the device.
3
automatic switch-off
and switches off automatically after 60 minutes.
OPERATION
DISPLAY
When the device is switched on, it normally
numbers, press this key.
1
Press “ZERO”
2
Press “ZERO”
OPERATION
DISPLAY
Attach the tare weight
weight from now on
1
Press “Tare”
OPERATION
Description
Press “PEAK”
shows the maximum value
Press “PEAK” again
measured values change again
OPERATION
DISPLAY
Description
Press the “MODE” key 5 times
current saving time
first 4 digits of the entire weight
last 4 digits of the entire weight
OPERATION
DISPLAY
Description
Press “Mode” 6 times. Then
current saving time
current weight
first 4 digits of the entire weight
last 4 digits of the entire weight
Press the “Mode” key again.
back

5.3 Function guide

5.3.1 ON / OFF

To switch on: Press “ON / OFF” and hold it for 3 seconds. The display will show the following:
Switch-off
Select “switch-off” in the parameter settings. is displayed. When the
device is not operated for 15 minutes it changes into the energy saver mode

5.3.2 Zero

5.3.3 TARE

5.3.4 PEAK HOLD

5.3.5 Data memory

and confirm with “Enter”.
displays . In case it shows small
after switching the
device on and press this
key. “TARE” is
displayed and the
display shows the net

5.3.6 Data search

press the “Enter” key.
9
Page 10

5.3.7 Delete memory

OPERATION
DISPLAY
Description
Press “Mode” 7 times and
question: delete or not?
Press “Mode” to stop.
Press “Enter” to delete.
OPERATION
DISPLAY
Description
Press “Mode” 3 times. Display
shows “dC”. Press “Enter”.
display power battery voltage
Press “Mode”.
back
OPERATION
DISPLAY
Description
Press “Mode”. Select “Unit” and
Press “Enter”. The units are
pressed.
Press “Mode” again.
back
OPERATION
Description
Press “Mode”. Select “ESC” and
press “Enter”.
to return to measurement mode
Key
Function
“Tare”
to change numbers
“ZERO”
to increase values
“MODE”
to save and exit
“ENTER”
to confirm
OPERATION
DISPLAY
Description
Press “Mode” twice.
to confirm, open the parameter
settings
Press “Enter”.
device displays capac ity in case it
is calibrated
Press “Zero” to select.
select capacity
Press “Enter” to confirm.
The display shows ld = 02. If the
the calibrated range.
Press “Zero” to select.
select division
01.
If the device is new, it will display
Pt = 0. If the device is calibrated,
confirm with “Enter”.

5.3.8 Battery voltage

5.3.9 To change the unit

Manual
press “Enter”.

5.3.10 To return to measurement mode

5.4 Parameter selection and calib r atio n

You can use the hand-held device to select parameter settings or calibration.

5.4.1 Key functions

5.4.2 Parameter settings

changed every time “Enter” is
10
02/03/05/06/10/15/20/30/50/60/75
2000 kg and for example FS =02.
The display shows
one after the other. Select cap:
device is calibrated, it will show
The display shows
01/02/05/10/20 one after the
other. 2000 kg The
division is 1 kg, so choose ld =
Page 11
Manual
it will display the calibrated
decimal place.
Press “Zero” to select.
Select the decimal place. 0/1/2/3
choose Pt = 0
Press “Enter” to confirm.
Device shows the zero point.
Press “Enter” to confirm.
If the device is new, it will display
calibrated value.
Press “Zero” to confirm.
C: search zero point. Range: 0 …
(2.5 Hz), 2 = fast (5 Hz)
Press “Enter” to confirm.
If the device is new, it will display it will display the calibrated value.
Press “Zero” to select.
LL: filter parameter, 6 options (0
and LL = 2 after calibration.
Press “Enter” to confirm.
If the device is new, it will display it will display the calibrated value.
Press “Zero” to select.
Select the unit. Un = 0: kg, Un =
Normally select Un = 0.
Press “Enter” to confirm.
If the device is new, it will display it will display the calibrated value.
Press “Zero” to select.
Choose the switch-off mode. You
automatic switch-off
Press “Enter” to confirm.
set point 1
Press “Enter” to confirm.
If the device is new, it will display it will display the calibrated value.
Press “Zero” to select.
Select set point 1. “1 OFF” means
that set point 2 is 1 higher.
Press “Enter” to confirm.
If the device is new, it will display it will display the calibrated value.
Press “ZERO” to determine the
decimal place.
Press “Enter” to confirm.
set point 2
Press “Enter” to confirm.
If the device is new, it will display it will display the calibrated value.
is displayed one after the other.
0 = xxxxx, 1 = xxxx,x, 2 = xxx,xx,
3 = xx,xxx
The capacity is 2000 kg, so
Cd = 11. If the device is
calibrated, it will display the
5
0 = 0 d, 1 = 0.5 d, 2 = 1 d, 3 = 1.5
d, 4 = 2 d, 5 = 2.5 d
d: display speed 3 options:
0 = slow (1.24 Hz), 1 = medium
LL = 2. If the device is calibrated,
… 5) from low to high.
Select LL = 0 before calibration
Un = 0. If the device is calibrated,
1: lb, Un = 2: N, Un = 3: KN, Un =
4: t
OFF 1. If the device is calibrated,
have 3 options: 0. manual switch-
off, 1. remote switch-off, 2.
1 OFF. If the device is calibrated,
that set point 1 does not inherit a
function. “1 LO” means that set point 1 is 1 lower. “1 HI” means
02000. If the device is calibrated,
value and “TARE” to move the
2 OFF. If the device is calibrated,
11
Page 12
Manual
Press “Zero” to select.
Select set point 2. “2 OFF” means
that set point 2 is 1 higher.
Press “TARE” to confirm.
If the device is new, it will display it will display the calibrated value.
Press “ZERO” to determine the
decimal place.
Press “Enter” to confirm.
Gravity is taken into account.
Press “Enter” to confirm.
If the device is new, it will display it will display the calibrated value.
Press “Mode”.
Confirm the above parameter
settings.
OPERATION
DISPLAY
Description
Select 2000 kg as capacity and
switching the device on.
Press “MODE” 8 times. The
calibration.
no load
Attach a standard weight of 2000
kg.
Wait until the STB signal is
displayed.
Press the “Enter” key.
If the first number in the
the STB signal on the screen.
Press “Mode” to save.
Confirm.
Press “Tara” to move the
decimal place.
Calibration finished.
DISPLAY
explanation
note
no wireless signal
open parameter settings
open tension settings
calibration point
select max. limit
tare weight cannot be the max.
limit
select min. limit
tare weight cannot be the min.
limit
wait
weight < minimum load
cannot be weighed
saving time exceeded
cannot save after 30 times
memory full
cannot save more than 99999
value and “TARE” to move the

5.4.3 Calibration

that set point 2 does not inherit a
function. “1 LO” means that set point 2 is 1 lower. “1 HI” means
01200. If the device is calibrated,
97940. If the device is calibrated,
make sure that the display
shows
the tare weight. You can also
attach the tare weight before
after attaching
display will show “CLIBr”. Press
“ENTER” and hold it for 3
seconds to confirm the

5.5 Display explanations

The display shows 0. Wait for the
STB signal.
parameter settings flashes,
select the capacity and wait for
12
Page 13
Manual
times
error in repeated saving
cannot save the same weight
twice
current number of memory locations
first 4 digits of the saved value
actual weight = first 4 digits + last
4 digits
last 4 digits of the saved value
actual weight = first 4 digits + last
4 digits
question whether you are sure that you want to
delete the memory
if not, stop the deletion process
deletion stopped
deletion confirmed
value is too high
value is too low
no value saved
appears when you check the
memory overload warning
overload warning
battery warning
after 1 min. automatic switch-off
battery voltage
end
finish parameter setting or
calibration switch-off
weight attached before STB light flashes
problem
possible reason
solution
no display
batteries defective
replace
key defective
call support
ON / OFF key has not been pressed properly
press the ON / OFF key firmly for 3 seconds
numbers flash
batteries low
recharge batteries
display does not show new attached
defective force transducer
call support
no longer calibrated
re-calibrate
display shows excessive weighings
The device has not sufficiently
allow 3 – 5 minutes to warm up
display shows Error in huge device has not been reset to 0
press ZERO before you start weighing
repeat calibration
see calibration
kg / lb wrong choice
see hand-held device
wireless connection reduced
batteries low
replace batteries

5.6 Troubleshooting

values when new loads are
deflections towards 0 between
letters during weighing
stabilised after switch-on
after switch-on
13
Page 14
Manual

6 Disposal

For the disposal of batteries, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
If you have any questions, please contact PCE Instruments.

7 Contact

If you have any questions about our range of products or measuring instruments please contact PCE Instruments.

7.1 PCE Instruments UK By post:

PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign Way, Southampton Hampshire
United Kingdom, SO31 4RF By phone:
Support: 02380 987 035 Sales: 02380 987 030

7.2 PCE Americas By post:

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter 33458 FL USA
By phone: Phone: 410-387-7703 Fax: 410-387-7714
14
Loading...