1. FEATURES
* It meets the stan dards of both ISO2178 and
ISO- 2360 as well as DIN, ASTM and BS.
Suit able for the laborator y and for use in
hars h field conditions.
* Th e F probes measure the thickness of non-
magnetic materials (e.g. paint, plastic,
porcelain enamel, co pper, zin c, alumini um,
chrome etc.) on magn etic materials (e.g.
iron, nickle etc.) . often used to measure the
thickness of galvani zing layer, lacquer
layer, porcelain en amel layer, pho sphide
layer, copper tile, aluminium tile, some
alloy tile, paper etc.
* The N probes measure th e thickness of
non-mag netic coatings on non -magnetic
metals. It is used on anodiz ing, varnis h,
paint, enamel, plastic coatings, p owder,
et c. appli ed to alum inum , br ass, non -
magnetic stainless steel, etc.
* Automatic substrate re cognition.
* Manual or auto matic shut down.
* Two measurem ent mode:
Single and Continuous
* Wide measuring range and high resolution.
* Metric/English conversion.
* Digital display gives exact reading with no
guessing or errors.
* Can communicate with PC computer for
statistics and printing by the optional cable and
the software for RS232C interface .
4
powe r and '0' shows up on the Display (3-2).
The gau ge will restore the st ate of last
operation itself , with a symbol 'Fe' or 'NFe'
indicating on Display. The gau ge enters the
auto mode which can automatica lly recogni ze
the substrate itself.
4.2 Place the probe (3-1) on a coatin g layer to be
measured. The reading on the Display is the
thickness of the coating layer.
4.3 To take the next measurement, just lift the
prob e (3-1) to more tha n 1 centimeter a nd then
repeat the step 4.2.
4.4 If you suspect the accuracy of measurement,
you should calibr ate before taki ng the
measurements. For the cal ibration proced ures,
please refer to the calibration p art 5.
4.5 T he g auge can be switched off by pressing
the Power key (3-3). On the other side, the
gauge will power itself off about 50 seconds
after the last operation.
4.6 To change the mea surement unit 'um' or 'mil'
by Depressing the Zero/Power key and not
releasing it till 'UNIT' on the Display. And
the unit changes after r eleasing the power key.
It takes about 6 seconds from start ing
2. SPECIFICATIONS
Disp lay 4 digits, 10 mm LCD
Rang e 0~5000 um/0~200mil
Othe
r range should be specified
Resolution 0.1 um (0~99.9um)
1 um (over 100um)
Accuracy ± 1~3%n or 2.5 um or 0.1 mil
(Whichever is the greater)
PC interface: with RS-232C inte rface
Powe r supply 4x1.5 AAA(UM-4) batt ery
Oper ating condition: Temp. 0~50 ,
Humidity <80%
Size 12 6x65x27 mm (5.0x2.6x1.1 inch)
Weight : about 81g not including battery
Accessories
Carrying case ............. ......1 pc.
Operation manual .......... .. 1 pc.
F prob e in built .............. ...1 pc.
NF pro be in built............ ...1 pc.
Calibration foils ......... .....1set
Subs trate (Iron) ............ 1 pc.
Subs trate (Aluminium).... ..1 pc.
Optional accessories:
Cable & software for RS232C
2
4. MEASURING PROCEDURE
4.1
Pr
ess the power key (3-3) to switch on th e
3-1
3-1 Probes inbuilt
3-2 Disp lay
3-3 Ze ro/Po we r Key
3-4 Bat tery Co mp artme nt/Co ve r
3-5 Jac k for RS2 32 C inter face
3. FRONT PANEL DESCRIPTIONS
3-2
3-3
3-4
3-5
depressing the Zero/Power key.
4.7 To change mea surement mode from the single
to continuous or vice visa, just de pressing the
Zero/ P ower key and not rel easing it till 'SC'
on the D i s p l a y. T h e m e a s u r em e n t m o d e
changes after re leasing the Power key. it takes
about 8 seconds from starting depressing the
Powe r key.
It is a continuous mode if the symbol on
the Display.
3
3-1