PCE Instruments CS 300, PCE-CS 300 User Manual

Manual
Crane Scales
PCE -CS 300
Version 1.0
Date of creation 04.09.2015
Date of last change 08.09.2015
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
Manual
2
Contents
1 Introduction ............................................................................................................. 3
2 Safety notes ............................................................................................................. 3
3 Specifications .......................................................................................................... 5
3.1 Accessories ................................................................................................................................ 5
4 System description ................................................................................................. 6
4.1 Measurement device .................................................................................................................. 6
4.2 Rear side .................................................................................................................................... 7
4.3 Dimensions in mm ...................................................................................................................... 7
4.4 Remote control ........................................................................................................................... 7
4.5 Displays ...................................................................................................................................... 8
5 Manual ...................................................................................................................... 9
5.1 How to switch on the scales ....................................................................................................... 9
5.2 Zeroing........................................................................................................................................ 9
5.3 Weighing ..................................................................................................................................... 9
5.4 How to switch off the scales ....................................................................................................... 9
5.5 Calibration................................................................................................................................... 9
5.6 Settings in the submenu ........................................................................................................... 10
5.7 How to recharge the lithium battery .......................................................................................... 10
6 Contact ................................................................................................................... 11
6.1 PCE Instruments UK ................................................................................................................ 11
6.2 PCE Americas .......................................................................................................................... 11
Manual
3
1 Introduction
Thank you for purchasing a PCE-CS 300 from PCE Instruments. You have chosen a crane scale in the 300 kg / 661lb version for control weighing. The power supply is provided by four 1.5 V AA batteries. The maximum weighing range of the crane scale is 300 kg.
2 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no warranty of damage or injuries caused by non-observance of the manual.
If the device is not in use for a longer period of time, the batteries should be taken out. Otherwise
the device can get damaged.
Using the device in another way than described in this manual can lead to dangerous situations. Do not expose the device to extreme temperatures or humidity, direct sunlight, or moisture. Only use it with dry hands. It is not allowed to modify the device in any way. The device should be cleaned only with a damp cloth. Do not use solvents or abrasives. It is only permissible to use the device with spare parts of PCE Instruments or equal, tested
products.
Moreover, the device must only be used under conditions stated in the specifications. The device must not be used in explosive atmospheres. Never measure higher weights than described in the specifications as this could damage or
destroy the device.
Since the lifting of weights can be dangerous, the manufacturer and the user have the special
duty to prevent dangerous situations. Using measuring equipment like this must at no time involve any hazard.
The people responsible for measuring equipment and the user have to observe national
regulations e.g. accident prevention, safety rules, work regulations and other regulations applicable to the use of this measuring equipment.
When using this device, it is also important to pay attention to the guidelines, regulations and
safety instructions made for example by the crane or shackles manufacturer.
The assembly, commissioning, maintenance and use of the device is only allowed by trained
personnel wearing protective clothing.
Repairs and maintenance work of the equipment must be carried out by trained staff on a regular
basis and must be documented along with the spare parts used. The equipment must be at least visually inspected before each use. If you see that any part of the equipment is incomplete or if there is damage like cracks, deformations or split-offs, the equipment must be banned from use. Please talk to the person responsible for safety at your company.
Manuals and safety instructions must always be with the device. The equipment is not ex protected and must not be used in explosive areas. Furthermore, the
environmental conditions have to match with the values stated in the specifications of this manual. Aggressive and corrosive areas need to be avoided. When there are considerable temperature fluctuations, some time for acclimatisation must be taken into account.
The device is suitable for lifting and weighing freely moveable loads only. Torsional stress must
not occur. Transporting people, pulling and tearing loads is not allowed.
The permissible nominal loads [MAX] of the measurement device and other equipment in use
should not be exceeded.
While using the device, you have to make sure not to enter the danger zone which is not just the
area below the load but also the area around the load.
Manual
4
Maintenance and testing
Check the device before each use
You must examine the device before using it. When checking the device, the user has to convince himself/herself,
- that the device is not deformed or otherwise damaged, (e. g. cracks).
- that every attachment is in flawless condition (e. g. hooks).
- that the complete system works without any hazards (e. g. improper installation).
- that the whole area is free of danger and if not, that countermeasures are taken. Regular control / maintenance
Every third month or 12,500 measurements, depending on what happens first
- Check the degree of wear.
- Check the dimensions.
- Check for any deformation and
damage.
- Verify proper function of every part.
Every year or 50,000 measurements, depending on what happens first
- Check every load-bearing parts for e. g. hair cracks. This must be carried out by trained staff.
Every 5 years or 250,000 measurements, depending on what happens first
- Exchange all load-bearing parts.
Every 10 years or 500,000 measurements, depending on what happens first
- Service life of the device has run out. Exchange the complete equipment.
This manual is published by PCE Instruments without any guarantee. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments.
Manual
5
3 Specifications
3.1 Accessories
1 x PCE-CS 300 4 x AA batteries 1 x snap hook 1 x hook 1 x remote control
Technical specifications Weighing capacity
300 kg / 661.39 lb
Readability
0.05 kg / 0.11 lb
Repeatability
1 kg / 2.20 lb
Min. weight
20 kg / 44.09 lb
TARE
full range
Protection
IP 54 (dust and splashproof)
Settling time
<10 s
Max. overload
50%
Display
20 mm LCD
Power supply
four batteries of size AA
General information:
Operating temperature
-10°C +40°C
Operating humidity
30% 90%
Weight
4 kg / 8.82 lb
Manual
6
4 System description
4.1 Measurement device
- 4.1 Zero button
- 4.2 Button to set resolution
- 4.3 Off button
- 4.4 On button
- 4.5 Display
Zero button
sets scale to zero
Button to set resolution
resolution between 0.10 kg and 0.05 kg
Off button
turns device off
On button
turns device on
Display
shows the weight result
Manual
7
4.2 Rear side
4.3 Dimensions in mm
4.4 Remote control
- 4.1 Off button
- 4.2 Button to set resolution
- 4.3 Zero button
- 4.4 No function
Off button
Turns device off
Set resolution
Resolution between 0,10 kg and 0,05 kg
Zero button
Zeros scale
Manual
8
4.5 Displays
LED display
LC display
When the arrow above this icon lights up, this means that the backlight will be on during operation.
The arrow above this icon lights up when the battery is low.
This icon indicates that the resolution / readability has been set to 0.5.
This icon means that the value is stable and can be recorded by the user.
Manual
9
5 Manual
5.1 How to switch on the scales
1. Open the cover on the rear side of the case.
2. Insert the 4 AA batteries and set the sliding switch to “B“. If you have chosen the scales with the optional lithium battery, please set the sliding switch to “A”
3. Close the cover.
4. Apply the mechanical power switch on the rear side of the scales. Then switch on the scales by means of the “On“ button. The maximum weighing range will be indicated first, followed by a self­checking sequence.
5. When 0.0 is indicated along with the respective icon, the equipment is ready for weighing. We recommend you to allow 3 to 5 minutes for warm-up before starting the weighing process.
5.2 Zeroing
1. When switched on, the scales normally show 0.0 kg or 0.00 kg. However, when the display indicates a different numerical value, push the “Zero“ button to zero the display.
2. When “Aut” is set to zero in the submenu, the backlight will be activated when you press and hold
the „Zero“ button for more that 3 seconds. Press and hold the “Zero” button again for 3 seconds
to deactivate the backlight. When “Aut“ is set to 1 in the submenu, the backlight will be activated automatically when you add load to the scale and will be deactivated when you remove the load.
5.3 Weighing
1. When the load has been attached to the scales completely, the weight will be displayed. When “stable” is indicated, the value can be recorded.
2. For taring, attach the tare weight, e. g. a cable, to the hook and push the “Zero” button to set the display to zero. The weight which is then indicated is the net weight. This weight will only change if the tare weight is modified or when the scale is switched off.
5.4 How to switch off the scales
1. The scales should be switched off after each weighing process. Push the “Off” button twice to switch off the display.
2. Then apply the mechanical Power switch on the rear side of the scales to power off the scales entirely and to prevent the battery from leaking.
5.5 Calibration
1. Turn off the scale.
2. Remove all loads.
3. Press and hold the Zero button and turn on the scale.
4. Release the Zero button now. The display shows SPEN.
5. Briefly press the Zero button once again. The display shows SET and 00000.
6. Set the weight of the calibration weight by pressing the ‘Off’ button to increase the value. By means of the ‘Set resolution’ button, the set digit is moved left.
7. Press the ‘Zero’ button again to save your settings.
Manual
10
5.6 Settings in the submenu
1. Turn on the scale.
2. While the scale counts down from 9 to 0, press the ‘Set resolution’ button briefly to confirm.
3. The scale now shows bEE 0.
4. By pushing the Off button, you can choose whether there is a beep tone when the value stabilizes (1) or not (2).
5. Press the Zero button to confirm.
6. Now the display shows CHt 0. By pressing the Off button you can change the unit.
7. Confirm again with the Zero button.
8. The display now shows Aut 0. You can choose if the backlight is off (‘0’) or in automatic mode (‘1’).
5.7 How to recharge the lithium battery
1. Open the cover on the rear side and insert the plug of the charger. Then connect the charger to a socket.
2. When the lithium battery is fully charged, the indicator of the charger will turn from red to green.
3. For optimum efficiency it is recommended to charge the scales when turned off.
4. To ensure ideal battery life, the battery should be recharged every 12 hours of operation.
Manual
11
6 Contact
If you have any questions about our range of products or measuring instruments please contact PCE Instruments.
6.1 PCE Instruments UK By post:
PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign Way, Southampton Hampshire
United Kingdom, SO31 4RF By phone:
02380 987 035
6.2 PCE Americas
By post:
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter 33458 FL USA
By phone: 561 3209162
Loading...