PCE Instruments PCE-ADL 11 Users guide

Page 1
© PCE Instruments
Anemometer PCE-ADL 11
User Manual
Last change: 2 July 2021
v1.0
English
Page 2
Contents
1 Safety notes ........................................................................................... 1
2 Introduction ........................................................................................... 2
3 Delivery scope ....................................................................................... 2
4 Specifications ........................................................................................ 2
5 Device description ................................................................................ 3
6 Software description............................................................................. 3
6.1 Icon description ................................................................................................................ 3
6.2 Graph description ............................................................................................................. 4
6.3 Data download ................................................................................................................. 5
6.4 Configure meter ............................................................................................................... 6
6.5 Zoom into graph ............................................................................................................... 7
6.6 Print graph ....................................................................................................................... 7
6.7 Export and import data ..................................................................................................... 7
6.8 Generate CSV file ............................................................................................................ 7
6.9 Further settings for the graphical view .............................................................................. 7
6.10 Change graph colours ...................................................................................................... 8
7 Insert/replace battery ............................................................................ 9
8 LED status display .............................................................................. 10
9 Contact ............................................................................................... 11
10 Disposal ............................................................................................... 11
© PCE Instruments
Page 3
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
• The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
• The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
• Do not expose the device to shocks or strong vibrations.
• The case should only be opened by qualified PCE Instruments personnel.
• Never use the instrument when your hands are wet.
• You must not make any technical changes to the device.
• The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
• The device must only be used with accessories from PCE Instruments or equivalent.
• Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device.
• Do not use the instrument in explosive atmospheres.
• The measurement range as stated in the specifications must not be exceeded under
any circumstances.
• Non-observance of the safety notes can cause damage to the device and injuries to the user.
• Remove the batteries when the device is not used for more than 60 days.
• Switch off the device when it is not in use.
We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of
business. If you have any questions, please contact PCE Instruments. The contact details can be found at
the end of this manual.
Page 4
© PCE Instruments
2
2 Introduction
The anemometer PCE-ADL 11 is a data logger for wind speed. The configuration of the anemometer is done via the supplied software. The wind speed meter measures various parameters. These include m/s, km/h, knots, mph and ft/min. In addition to the measurement parameters, the measurement intervals can be set in the software. The memory has enough capacity for 60,000 measured values. After completion of the measurement series, the data can be read out on the computer via the software. The measurement results are displayed either graphically as a curve or in tabular form.
3 Delivery scope
1 x anemometer PCE-ADL 11 1 x mounting equipment 1 x software 1 x impeller 1 x 3.6 V lithium thionyl chloride battery 1 x user manual
4 Specifications
Measurement range
1.2 ... 30.0 m/s
4.3 ... 108.0 km/h
2.33 ... 58.32 knots
2.69 ... 67.2 mph
236 ... 5906 ft/min
Resolution
0.01 m/s
0.1 km/h
0.1 knots
0.1 mph
1 ft/min
Accuracy
m/s: ±(3 % + 0.20 m/s)
km/h: ±(3 % + 1.0 km/h)
knots: ±(3 % + 0.4 knots)
mph: ±(3 % + 0.4 mph)
ft/min: ±(3 % + 40 ft/min)
Memory
for up to 60000 measured values
Data interface
USB for data transfer
PC software
for data evaluation with graphical representation
Selectable recording intervals
3 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 30 min, 1 h, 2 h, 3 h, 6 h, 12 h
Operating status
indicated by red, yellow and green LED
Alarm when extreme values are exceeded
yes
Measuring modes
automatic and manual start of measurement
Sensor
anemometer
Power supply
lithium thionyl chloride battery, 3.6 V Mignon
Low battery voltage alarm
Yes
Operating conditions
0 ... +50 °C / 32 ... 122°F, <80 % RH
Max. height above sea level
2000 m / 6561 ft
Weight
49 g / <1 lb
Dimensions
145 x 35 x 30 mm / 5.7 x 1.4 x 1.2 in
Page 5
© PCE Instruments
3
5 Device description
1. LED data recording
2. LED alarm limit / battery status
3. Key to start manual measurement
6 Software description
To use the PCE-ADL 11, you need the included software. With this software, you can set up the device, download the measured values from the PCE-ADL 11 and evaluate them as you wish in tabular or graphical form.
6.1 Icon description
Icon
Description
Explanation
Download
The measured values from the PCE-ADL 11 can be downloaded here.
Setting
The PCE-ADL 11 can be configured here.
Open
Measurement data can be imported from your PC here.
Save As
The measurement data can be exported here.
Print
The currently displayed graph can be printed here.
View all
If you have zoomed into the graph, you can display the whole graph again here.
Zoom in
Here you can zoom into the graph.
Move
With this tool the graph can be moved.
About
Here you can view the software version.
Page 6
© PCE Instruments
4
6.2 Graph description
On the X-axis you can see the time of measurement. On the Y-axis you can see the measured value.
6.2.1 Caption
Abbreviation
Description
Explanation
RT
Realtime
The real measured value in the set storage interval is displayed here
MAX
Maximum value
The highest measured value in the set storage interval is displayed here
MIN
Minimum value
The lowest measured value in the set storage interval is displayed here
AVG
Average
Here the average reading is displayed. The average value refers to all measuring points over the storage interval at a measuring rate of one second, e. g. 10 measured values with a storage rate of 10 seconds
Page 7
© PCE Instruments
5
6.2.2 Display of the measured values
If you move the mouse over a measuring point, the measured value is displayed directly at the top right of the graph.
6.2.3 Alarm limits in the graph
The set alarm limits are shown in the graph as a dashed red line.
6.3 Data download
To download the data from the PCE-ADL 11, first connect the meter to your PC. Then click on the "Download" icon. Another window appears and the software automatically connects to the meter after a few seconds. Cancel the process with "Cancel". Once the software is connected to the meter, you must click on "Download" to transfer the measurement data to your PC.
Then click on "View" to view the data in graphical form.
Page 8
© PCE Instruments
6
6.4 Configure meter
To configure the meter, connect the PCE-ADL 11 to the PC. Then click on the "Setting" icon. Another window opens and the software automatically connects to the meter.
Parameter
Meaning
Basic settings
Model Select
Instant: The meter starts the measurement directly after you confirm the configuration via "Setup". Important: A live view is not possible.
Manual: The meter starts the measurement after you press the start key on the meter.
Current Time
Current time of your PC. This time is also transmitted to the meter.
Sample Point
Number of measuring points to be recorded
Sample Rate
Specification of the storage rate
Recording Time
This indicates how long the meter measures with the settings made until the measurement is finished.
LED Flash Cycle
Here you can specify when the status LED should light up
Alarm settings
LED flash
Here you can specify whether the alarm LED flashes when the limits are exceeded or not reached.
Low Alarm
Here you can enter the limit value for the lower limit.
High Alarm
Here you can enter the limit value for the upper limit.
Unit
Here you set the unit in which the meter records the data. Important: The unit of the recorded data cannot be changed afterwards.
More buttons
Default
The configuration is reset here.
Setup
Here the configuration is transferred to the PCE-ADL 11. Attention: The already saved measurement data will be deleted.
Cancel
No data is saved and the window closes.
Page 9
© PCE Instruments
7
6.5 Zoom into graph
If you have recorded measurements over a long period of time, it can be difficult to analyse the readings accurately. In order to analyse a specific period of time, it is helpful to display this specific range. For this purpose, there is the "Zoom in" function. To use this, click on "Zoom in" and mark the area you want to analyse more precisely. The marked area is enlarged immediately.
6.5.1 Move graph
To move the graph now, click on "Move". You can now move the graph within the X- and Y-axes.
6.5.2 Normal view
To return from zoom view to normal view, click once on "View all".
6.6 Print graph
To print the displayed graph, click on "Print". Now you can print the graph. Important: The current view is always printed. This means that if you have zoomed into the graph, only the zoomed part will be printed.
6.7 Export and import data
To export the measurement data, click on "Save As". From here, you can save the measurement data to another storage medium or directly to your PC. To import the measurement data again, click on "Open". From here, select the measurement data.
6.8 Generate CSV file
To generate a CSV file of the measured values, first click on "File". Then click on "Export to Excel". From here, select the storage location.
6.9 Further settings for the graphical view
By right-clicking on the graph, you can view further setting options for the graphical view.
Page 10
© PCE Instruments
8
Parameter
Meaning
View All
Here you can view the entire graph again
Move View
Here you can move the graph
Zoom in
Here you can zoom into the graph
ColorSetting
Change graph colours
Grid X
Show or hide X-axis lines
Grid Y
Show or hide Y-axis lines
MaskPoints
Show or hide measuring points
Alarm Line
Show or hide alarm line
Maximum trace
Here you can show or hide the line for the highest measured values
Minimum trace
Here you can show or hide the line for the lowest measured values
Average trace
Here you can show or hide the line for the average values
RT trace
Show or hide real-time line
6.10 Change graph colours
To change individual graph colours, first right-click on the graph and select "ColorSetting". The following window opens:
Here you can change individual colours now. The preview shows you every change directly.
Parameter
Meaning
Background Color
Change background colour
Border Colour
Change border colour
Grid Color
Change grid colour
Line Color
Change the colour of the average measurement line
Default
Reset settings
OK
Colours are adopted
Cancel
Discard settings
Page 11
© PCE Instruments
9
7 Insert/replace battery
When the battery goes flat, you must replace it. The data logger does not lose any saved data when the battery is discharged or replaced. However, the data storage process is stopped and cannot be restarted until the battery has been replaced and the saved data has been downloaded to the PC. Only use 3.6 V lithium batteries.
Page 12
© PCE Instruments
10
8 LED status display
The PCE-ADL 11 has an LED status display. The following chart explains the meaning of the LED status display.
LEDs
Meaning
No LED flashes Data recording is not active
Battery inserted incorrectly
Green LED flashes every 10, 20 or 30 seconds
Data recording is active No alarm
Green LED flashes twice every 10, 20 or 30 seconds
Meter ready for logging. Press the yellow key on the back.
green LED flashes three times
Data recording started during the manual start-up process
Red LED flashes every 10, 20 or 30 seconds
Data recording active Measured value fallen below
Red LED flashes twice every 10, 20 or 30 seconds
Data recording active Measured value exceeded
Yellow LED flashes twice every 10 seconds
Battery voltage is low
Yellow LED flashes every second or every 5, 10 or 15 seconds
Data recording completed
Page 13
9 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact
us. You will find the relevant contact information at the end of this user manual.
10 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re­use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.
© PCE Instruments
11
Page 14
© PCE Instruments
12
PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L. Im Langel 4 23, rue de Strasbourg Calle Mayor, 53 D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete) Deutschland France España Tel.: +49 (0) 2903 976 99 0 Téléphone: +33 (0) 972 3537 17 Tel. : +34 967 543 548 Fax: +49 (0) 2903 976 99 29 Numéro de fax: +33 (0) 972 3537 18 Fax: +34 967 543 542 [email protected] [email protected] [email protected] www.pce-instruments.com/deutsch www.pce-instruments.com/french www.pce-instruments.com/espanol
United Kingdom Italy Turkey
PCE Instruments UK Ltd PCE Italia s.r.l. PCE Teknik Cihazları Ltd.Şti. Unit 11 Southpoint Business Park Via Pesciatina 878 / B-Interno 6 Halkalı Merkez Mah. Ensign Way, Southampton 55010 Loc. Gragnano Pehlivan Sok. No.6/C Hampshire Capannori (Lucca) 34303 Küçükçekmece - İstanbul United Kingdom, SO31 4RF Italia Türkiye Tel: +44 (0) 2380 98703 0 Telefono: +39 0583 975 114 Tel: 0212 471 11 47 Fax: +44 (0) 2380 98703 9 Fax: +39 0583 974 824 Faks: 0212 705 53 93 [email protected] [email protected] [email protected] www.pce-instruments.com/english www.pce-instruments.com/italiano www.pce-instruments.com/turkish
The Netherlands Hong Kong United States of America
PCE Brookhuis B.V. PCE Instruments HK Ltd. PCE Americas Inc. Institutenweg 15 Unit J, 21/F., COS Centre 1201 Jupiter Park Drive, Suite 8 7521 PH Enschede 56 Tsun Yip Street Jupiter / Palm Beach Nederland Kwun Tong 33458 FL Telefoon: +31 (0)53 737 01 92 Kowloon, Hong Kong USA [email protected] Tel: +852-301-84912 Tel: +1 (561) 320-9162 www.pce-instruments.com/dutch [email protected] Fax: +1 (561) 320-9176 www.pce-instruments.cn [email protected]
Loading...