PCE Group AB Series, PCE-AB-100, PCE-AB-200 User Manual

www.pce-group-europe.com
Made in Europe
PCE Deutschland GmbH&Co.KG Im Langel 4 Deutschland D-59872 Meschede Tel: 029 03 976 99-0 Fax: 029 03 976 99-29 info@warensortiment.de www.pce-group-europe.com

USER MANUAL

AB-SERIES 100 / 200
PCE-Group: ba-analysenwaage-pce-ab-100-GB
2 USER MANUAL
____________________________________________________________________________________________________________________
www.pce-group-europe.com
Contents:
1. General description.............................................................................3
2. Technical data.....................................................................................4
3. Completeness.....................................................................................4
4. Security rules......................................................................................5
5. Keys and indicators.............................................................................6
6. Preparations – working environment ..................................................7
7. Preparation – the balance...................................................................8
8. Operation principles............................................................................9
9. Start-up and user menu....................................................................10
9.1 Pieces counting function...................................................................11
9.1.1. Counting with reference sample .....................................................11
9.1.2. Counting with unit weight................................................................12
9.2 Auto-tare function..............................................................................13
9.3 External calibration / calibration options ...........................................14
10. Internal calibration.............................................................................16
11. Connecting the balance with a computer or a printer .......................17
12. Troubleshooting and maintenance....................................................18
Declaration of Conformity
3 USER MANUAL
____________________________________________________________________________________________________________________
www.pce-group-europe.com
1. General description
AB series balances are destined for high accuracy weighing in laboratory practice.Balances are equipped with internal calibration system for proper accuracy control during operation. The user should also own weight standard of OIML E2 class for periodical control of the balance (weight value stated in Technical Data sheet) ­available separatelly. All balances are metrologically tested - calibration or legal verification certificate on demand.Legal verification is required for balances used in some applications: direct sale, pharmaceutical prescriptions, medical and pharmaceutical analysis, goods packing and others.Balances with legal verification are mark with the following:
- protective seal placed on the casing mounting screw at the back of the balance,
- calibration switch protective seal,
- notified body stamps and green metrological marking placed on the balance name
plate.
4 USER MANUAL
____________________________________________________________________________________________________________________
www.pce-group-europe.com
2. Technical data
Type Capacity (Max) 100 g 200 g Min load (Min) 100 mg 100 mg Reading unit (d) 0,1mg 0,1mg Verification unit (e) 1mg 1mg Tare range -100 g -200 g Accuracy class I Working temperature Weighing time <5 s Pan dimension Balance base dim. 210 x 510 x 350 mm Balance weight external feeder.ZN 12V/ 500 mA: AC: 230 V 50 Hz 6VA / DC:
Power 7,5kg Calibration weight
(OIML)
PCE-AB-100 PCE-AB-200
+18 ÷ +33 °C
φ 90 mm
=12V 500 mA
100g – E2 200g – E2
3. Completeness
A standard set consist of:
1. Balance
2. Pan base and a pan,
3. Feeder (ZN12V/500mA)
4. User manual
5 USER MANUAL
____________________________________________________________________________________________________________________
www.pce-group-europe.com
4. Security rules
To avoid electrical shock or damage of the balance or connected peripheral devices, it is necessary to follow the security rules below.
All repairs and necessary regulations can be made by authorised personnel only.
To avoid fire risk use a feeder of an appropriate type (supplied with the balance). Pay attention that supply voltage is compatible with specified technical data.
Do not use the balance when its cover is opened.
Do not use the balance in explosive conditions.
Do not use the balance in high humidity.
If the balance seems not to operate properly, unplug it from the mains
and do not use until checked by authorised service.
6 USER MANUAL
____________________________________________________________________________________________________________________
www.pce-group-europe.com
5. Keys and indicators
g
0% 100%
keys key
key ENTER - confirm key
key 1/F1 ... 5/F5 - numeric / functional keys, key
key key 8/
key 9/MENU - numeric key / Menu, key
key key key
indicator indicator linear - tatal load indicator (0-100%),
indicator OFF - stand-by mode, Max, Min, d, e,
T
I
/
.
0
6/
7/
- numeric key / internal calibration,
0/
> <
I - metrologic parameters and accuracy class.
- tare (subtract package weight from weighed mass)
- switch-off (standby),
- decimal point,
- numeric key / zeroing (balances for direct sale use
only),
- numeric key / data output (print / transmission),
- numeric key / special function,
- enter an option,
- leave an option,
- navigation / move a cursor up,
- navigation / move a cursor down,
- result stabilisation,
Loading...