![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bg1.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
5410/5411
5410/54115410/5411
5410/5411
Brighten Your Digital View!
4-Channel Integrated H.264
HD Encoder-Modulator
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bg2.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
01 Notice
03 Before Using the Device
04 1 Overview
04 2 Features
05 3 Technical Specifications
06 4 Block Diagram
07 5 Front panel and rear panel instructions
07 5.1 Front panel
07 5.2 Rear panel
08 6 Control with Front Panel
08 6.1 Overview of the Menu
09 6.2 Description of menu
09 6.2.1 Status
10 6.2.2 Encoder
11 6.2.3 Remux
12 6.2.4 TS/IP (Multiple Output Mode)
13 6.2.5 TS/IP (Full Duplex Mode)
14 6.2.6 Modulation (QAM)
14 6.2.7 Modulation (COFDM)
15 6.2.8 RF Setting
15 6.2.9 ASI Output
15 6.3 System
17 7 Control with Web Server
17 7.1 Status
Contents
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bg3.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
Notices
COPYRIGHT (Copyright © 2013 Beijing Jaeger Communication Electronic Technology Co., Ltd.)
Not to be copied, used or translated in part or whole without Beijing Jaeger prior consent in writing
except approval of ownership of copyright and copyright law.
WARRANTY
This warranty does not cover parts which may become defective due to misuse of the information
contained in this manual.
Read this manual carefully and make sure you understand the instructions provided. For your
safety, be aware of the following precautions.
WARNING! IMPORTATNT SAFETY INSTRUCTIONS
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING
• To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
• To avoid explosion danger, do not dispose of batteries in an open fire.
CE MARK FOR EUROPEAN HARMONISED STANDARDS
The CE mark which is attached to these products means it conforms to EMC Directive
(89/336/EEC) and Low Voltage Directive (73/23/EEC).
IMPORTANT INFORMATION
Please retain the original packaging, should it be necessary at some stage to return the device.
Disposal of Old Electrical and Electronic Equipment (Applicable in the European Union and
other European countries with separate collection systems)
This symbol on the product or on its packaging indicates that this product shall not be
treated as household waste. Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences for the
environment and human health, which could otherwise be caused by inappropriate waste
handling of this product. The recycling of materials will help to conserve natural resources.
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bg4.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
For more detailed information about recycling of this product, please contact your local
Civic Office, your household waste disposal service, or the shop where you purchased the
product.
COPYRIGHTS
Television programs, movies, video tapes, discs, and other materials may be copyrighted.
Unauthorized recording of copyrighted material may be against the copyright laws in your region.
Also, use of this product with cable television transmissions may require authorization from the
cable television operator or transmitter/owner.
VENTILATION
• Do not expose the product to high temperatures, such as placing it on top of other product that
produce heat or in places exposed to direct sunlight or spot lights.
• The ventilation slots on top of the product must be left uncovered to allow proper airflow into the
device.
• Do not stand the product on soft furnishings or carpets.
• Do not stack electronic equipment on top of the product.
• Do not place the product in a location subject to extreme changes in temperature. The temperature
gradient should be less than 10 degrees C/hour.
• Place the product in a location with adequate ventilation to prevent the build-up of heat inside the
product. The minimum ventilation space around the device should be 7 cm. The ventilation should
not be impeded by covering the ventilation openings with items, such as newspapers, table cloth,
curtains, etc.
POWER SOURCES
• The product is not disconnected from the AC power source (mains) as long as it is connected to the
power outlet or wall socket, even if the product is turned off.
• If the product will not be used for a long period of time, disconnect it from the AC power outlet or wall
socket.
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bg5.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
Before Using the Device
Thank you for purchasing the DXP-5410/5411EM 4-Channel Integrated Encoder-Modulator. This
User Manual is written for operators/users of the DXP-5410/5411EM to assist in installation and
operation. Please read this user manual carefully before installation and use of the device.
FOR YOUR SAFETY
This equipment is provided with a protective earthing ground incorporated in the power cord. The
main plug shall only be inserted in a socket outlet provided with a protective earth contact. Any
interruption of the protective conductor, inside or outside the device, is likely to make the device
dangerous. Do not remove the covers of this equipment. Hazardous voltages are present within
this equipment and may be exposed if the covers are removed. Only Beijing Jaeger trained and
approved service engineers are permitted to service this equipment.
The supplied AC power cable must be used to power the device. If the power cord becomes
damaged it must be replaced. No operator serviceable parts inside. Refer servicing to Beijing
Jaeger trained and approved service engineers. For the correct and safe use of the device, it is
essential that both operating and servicing personnel follow generally accepted safety procedures
in addition to the safety precautions specified in this manual. Whenever it is likely that safety
protection is impaired, the device must be made in-operative and secured against unintended
operation. The appropriate servicing authority must be informed. For example, safety is likely to be
impaired if the device fails to perform the intended measurements or shows visible damage.
WARNINGS
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bg6.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
• The mounting environment should be relatively dust free, free of excessive vibration and the ambient
temperature between 0C° to 40C°. Relative humidity of 20% to 80% (non-condensed) is
recommended.
• Avoid direct contact with water.
• Never place the equipment in direct sunlight.
• The outside of the equipment may be cleaned using a lightly dampened cloth. Do not use any
cleaning liquids containing alcohol, methylated spirit or ammonia etc.
• For continued protection against fire hazard, replace line fused only with same type.
• Air intake for cooling is achieved via holes at the side of the device and the fans inside. The air flow
should not be obstructed. Therefore, the device has to be placed on a flat surface, leaving some
space at the sides of the device.
• When in operation, the internal temperature should not exceed the limit of 70C°.
DXP-5410/5411EM
4 Channel Integrated Encoder-Modulator
1 Overview
DXP-5410EM/5411EM is an integrated 4-channel real-time encoder re-multiplexer modulator. Four sets of A/V
inputs are encoded and generated 4 Transport Streams (TS) independently. TS streams from the internal
encoders, ASI input and TS/IP (TS_over_IP) input (duplex mode only) could be re-multiplexed into one MPTS
(Multiple Program TS), then modulated onto one DVB RF carrier, QAM or COFDM. This MPTS is also available
at the ASI output & TS/IP output simultaneously. There are up to 5 streams encapsulated onto TS/IP output when
TS/IP is configurated as Multi-output mode. In this mode, all 4 TS streams from internal encoder could be sent
through the TS/IP port while the fifth IP slot could be fed with the internal re-multiplexer or ASI input. With a builtin RF back-up relay switch, any external RF signal could be fed to the main output for back-up in cases of internal
malfunction (main RF level < 75dBuV) or power supply lost.
DXP-5410EM/5411EM series are accommodated in 1U x 19” standard chassis with 2 redundant power supply
modules.
2 Features
Comply with H.264/AVC HP@L4.1
4 independent real-time encoders
Integrated 6-input TS reMUX, (4 for encoders, 1 for ASI in, 1 for TS/IP in)
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bg7.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
ASI & TS/IP outputs
Up to 5 TS/IP output streams (200Mb/s Max.)( 4 for encoders, 1 for ASI mirrored or reMUX)
480i/NTSC, 576i/PAL, 720p,1080i & 1080p
Constant Bit Rate (CBR) & Variable Bit Rate (VBR)
DVB-C/QAM (ITU J.83 Annex A/C) or DVB-T/COFDM RF out, selectable
50MHz ~ 996MHz RF carrier output frequency adjustable
120dBµV Total Output Level
RF Back-up loop through input (RF relay)
SNMP & HTTP remote control & monitor
Software could be upgraded with Web interface
EIA 1U x 19” standard chassis with 2 redundant power supply modules
3 Technical Specifications
Video Input & Encoding
Input type
CVBS x 4 BNC Female 75Ω, HDMI x 4 A-type Sockets or HD-SDI x 4 BNC Female
75Ω (see ordering info.)
Encoding Standard
H.264/AVC High Profile, up to Level 4.1
Y/Cb/Cr Sampling Format 4:2:0
Video Resolution &
Recommended Bit Rate
(see ordering info.)
1080p (1920x1080) @25Hz, 29.97Hz, 30Hz:SMPTE274M: 6~40Mb/s
1080i (1920×1080) @25Hz, 29.97Hz, 30Hz:SMPTE274M: 6~20Mb/s
720p (1280×720) @25Hz, 29.97Hz, 30Hz:SMPTE296M: 6~20Mb/s
480i (720×480) @29.97Hz:BT.656: 2~15Mb/s
576i (720×576) @25Hz: BT.656: 2~15Mb/s
Other Video Resolution &
Down Scaler
Full D1,Half D1,SIF,QSIF
Vertical & Horizontal Pixel down scalable respectively (with frame rate not changed)
Aspect Ratio 4:3 or 16:9 adjustable
Audio Input & Encoding
Audio Input type
Analog Stereo x 4 pairs of BNC Female, HDMI Embedded or HD-SDI Embedded
(see ordering info.)
MPEG1 Layer II, Mono: 32~192Kb/s, Stereo: 64~384Kb/s
Standard & Recommended
Bit Rate
AAC-LC 2ch, Stereo: 128 ~ 512Kb/s (DXP-5410EM-X only)
Sampling Rate 48KHz
DVB-ASI Input
Interface Type BNC Female, 75Ω
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bg8.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
Maximum Effective Bit Rate 200 Mb/s
Data type Byte
Packet Length 188/204 Bytes
Valid Receiving Amplitude 200 ~ 880mVp-p
DVB-ASI Output
Interface Type BNC Female, 75Ω
Maximum Effective Bit Rate 200Mb/s
Data type Byte
Packet Length 188/204 Bytes
Output Waveform Level 800±80mVp-p
TS/IP Gigabit Ethernet (Duplex mode)
Physical Layer Standard IEEE 802.3, 10/100/1000 Base-T
Maximum Effective Bit Rate Input: 200Mb/s, Output: 200Mb/s
Data Encapsulation UDP, RTP, SPTS, MPTS
Other Protocols ICMP, ARP, IGMPv2
TS/IP Multiple Stream, Output Only
Physical Layer Standard IEEE 802.3, 10/100/1000 Base-T
Maximum Effective Bit Rate Output: 200Mb/s
Data Encapsulation UDP, RTP, SPTS, MPTS
Other Protocols ICMP, ARP, IGMPv2
QAM Modulation
Standard of System ETSI EN300 492, ITU J.83, Annex A/C: 16/32/64/128/256QAM
Symbol Rate 3~7.2MS/s
I/Q Amplitude Error ≤ 0.1%
I/Q Phase Error ≤ 0.1%
Phase Jitter < 0.5°RMS
MER 36dB min., 42dB typ. (with tester equalizer “off ” )
COFDM Modulation
Standard of System ETSI EN 300 744
Constellation QPSK/16QAM/64QAM
Bandwidth 5/6/7/8MHz
FTT carrier number 2K, 8K
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bg9.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
Guard Interval
1/4,1/8,1/16,1/32
FEC rate
1/2,2/3,3/4,5/6,7/8
MER 36dB min., 40dB typ.
RF Output
Interface
F-type Female,75Ω
Carrier Central Frequency
50~996MHz adjustable,step by 10 KHz
Output Level 90~120dBµV, step by 1dB
Spurious ≥60dBc @ 120dBuV
Return Loss
≥12dB(typ.)
Rear Panel
ASI In 1 x BNC Female, 75Ω
CVBS In (option, see order
info.)
4 x BNC Female, 75Ω ( for DXP-5410EM/5411EM-C only)
Audio In (4X2) x BNC Female, 75Ω (DXP-5410EM/5411EM-C only)
HDMI In 4x HDMI A-type Sockets (DXP-5410/5411EM-H only)
HD-SDI In 4x x BNC Female, 75Ω (DXP-5410/5411EM-S only)
ASI Out 2 x BNC Female, 75Ω (mirrored contents)
RF Out 1x F Type Female, 75Ω
Back-up RF In 1x F Type Female, 75Ω
Front Panel
Control 1×RJ-45, 10/100 Base-T
TS/IP 1× IP (GbE), RJ-45, 10/100/1000 Base-T
Display 20 x 2 character VFD
RF Monitor -20dB 1x F Type Female, 75Ω
Others
Operating Input Voltage AC100~260V 50/60Hz
Operating Temperature
0 ~ 40℃
Storage Temperature
-10 ~ 60℃
Operating Humidity 10 ~ 90%, Non-condensed
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bga.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
A3 A4
4 Block Diagram
5 Front panel and rear panel instructions
5.1 Front panel
A5
A7
A6
A2
A1
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bgb.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
A1 Status LEDs Power: green when power is on, red when one of the power supply unit
malfunction
Warning: red when function faulty
Alarm: red when function critical
A2 Encoder Status Encoder 1~4 working status, green light indicates the corresponding encoder
module is under working, red when the corresponding encoder module
malfunction or stop or input is invalid (the other 4 LEDs are not used)
A3 VFD Panel Menu display
A4 Keypad 6 keys for local control
A5 USB Used to upgrade software version of this device
A6 Management Ethernet (10/100 LAN) control port
A7 TS/IP TS over IP input and output port
5.2 Rear panel
DXP-5410EM/5411EM-C
DXP-5410EM/5411EM-H
B1
B2
B3
![](/html/b7/b765/b76513399e9ded090b873ff522af46b6f535123e36a11059c47a671a2de4720e/bgc.png)
ООО «ТЛК Трейд» | 196158, г.Санкт-Петербург, Пулковское шоссе, д.30, корп.4, оф. 213В (юр.) | ИНН 7810592830 КПП 781001001
р/с 40702810068000007550 | к/с 30101810200000000704 | Филиал ОПЕРУ ОАО Банк ВТБ в Санкт-Петербурге | БИК 044030704
ОКПО 66035862 | ОКАТО 40284565000 | ОГРН 1107847196060 | т.(812)6499888 | http://www.tlct.ru http://www.rftel.ru
mail@tlct.ru
DXP-5410EM/5411EM-S
B1 ASI IN ASI input interface
B2 ASI OUT 2 ASI output interface (output in mirror)
B3 Audio Video Input CVBS and Audio input interface
B4 RS232 Reserved for factory use
B5 Alarm Alarm relay interface
B6 RF Out Main RF output port
B7 RF In (Back Up) Backup RF signal input port
B8 Power Socket AC Power Input
6 Control with Front Panel
With the keypad and display panel on the front panel, user can configure the device locally.
6.1 Overview of the Menu
Power on the device and wait for initialization complete, the Local IP address will be displayed on the VFD
panel. Press〔ENTER〕to get into the main menu.
Main Menu