PB Heat SERIES MI, MIH Series, MI Series User's Information Manual

USER’S INFORMATION MANUAL
S
ERIES
MI/MIH™G
AS
B
TO THE INSTALLER:
This manual is the property of the owner and must be affixed near the boiler for future reference.
TO THE OWNER:
This boiler should be inspected annually by a Qualified Service Agency.
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
TO BE COMPLETED BY THE INSTALLER
Service Agency Phone No.
Address
Boiler Model No. Serial No. Date of Installation:
– Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
– Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
PB HEAT, LLC
131 S. CHURCH ST • BALLY, PA 19503
MI8039 R6 (6/11-4M)
Printed in U.S.A.
©2011 PB Heat, LLC. All rights reserved.
Basic Operation
WARNING
CAUTION
Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency.
Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance.
Do not use this boiler if any part has been under water. Immediately call a qualified service agency to inspect the boiler and to replace any part of the control system and any gas control which has been under water.
A. General. This water boiler is a natural draft appliance and is equipped with controls for proper
operation. All controls must be in proper working order. Contact a qualified service agency to provide annual maintenance as specified in Installation, Operation and Maintenance Manual.
1. Limit. See Figure 1. A device which automatically interrupts boiler operation when the water temperature exceeds the set point. Maximum allowable temperature is 240°F (115°C).
Original equipment with this boiler is a Honeywell L8148E1182. Boiler operation is interrupted when system temperature reaches cut-out temperature. Boiler operation resumes automatically when system temperature falls approximately 15°F (8°C) below the cut-out temperature. See also Figures 4 and 5 for limit sequence of operation.
2. Flame Rollout Switch. See Figure 1. A device which automatically interrupts boiler operation when flames or excessive heat are present in the combustion area. The control is a single use device. If the control is activated to interrupt boiler operation, do not attempt to place boiler in operation. Contact a qualified service agency.
3. Blocked Vent Switch (Vent Safety Shutoff Switch). See Figure 1. A device which automatically interrupts boiler operation when there is a blockage in the vent pipe or chimney. The control is a manual reset device. The control is located on the draft hood relief opening. If the control was activated to interrupt boiler operation, do not attempt to place boiler in operation. Contact a qualified service agency.
4. Pilot. The pilot provides the ignition source for the main burners. Your boiler has a standing (continuous) pilot or an intermittent pilot. The intermittent pilot ignites only when there is a call for heat and extinguishes when the call for heat ends. See Figures 6 and 7.
5. Gas Valve. The gas valve monitors pilot flame and regulates gas flow to the burners and pilot. See Figure 1.
6. Safety Relief Valve. A device which protects the boiler against excessive pressure. The safety relief valve can discharge a large amount of hot water - the installer should provide piping to discharge water near floor at a floor drain. If the safety relief valve discharges water, follow instructions TO TURN OFF GAS TO APPLIANCE (see Figure 2 or 3), and contact a qualified service agency.
2
Figure 1: Control Locations
B. Instructions to place boiler in operation and to turn off the boiler are shown on the Operating or
Lighting Instruction Label posted on the left side of the boiler. The instructions are also shown in Figures 2 and 3.
C. The Sequence of Operation is shown in Figures 4 and 5.