PB Heat SC SERIES, SCT SERIES, LC SERIES, LCE SERIES User's Information Manual

USER’S INFORMATION MANUAL
SERIES SC/SCT ™and LC/LCE™GAS BOILERS
TO THE INSTALLER:
This manual is the property of the owner and must be affixed near the boiler for future reference.
This boiler should be inspected annually by a Qualified Service Agency.
TO BE COMPLETED BY THE INSTALLER
Service Agency Phone No.
Address
Boiler Model No. Serial No. Date of Installation:
– Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
– Installation and service must be
performed by a qualified installer, service agency or the gas supplier.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
– Ne pas ranger ou utiliser de la gazoline ou
d’autres liquides ou gaz inflammables à proximité de cet appareil ou d’un autre du même type.
– QUE FAIRE SI VOUS DÉTECTEZ UNE
ODEUR DE GAZ
• Ne pas tenter d’allumer l’appareil.
• Ne toucher à aucun interrupteur électrique ; n’utiliser aucun appareil téléphonique dans l’immeuble.
• Contacter immédiatement votre fournisseur de gaz à partir du téléphone d’un voisin. Suivre les instructions données par votre fournisseur de gaz.
• S’il est impossible de rejoindre le fournisseur de gaz, appeler le service des incendies.
– L’installation et l’entretien doivent être effectués
par un installateur qualifié, une société d’entretien ou le fournisseur de gaz.
Négliger de suivre ces instructions à la lettre pourrait provoquer un incendie ou une explosion causant des dégâts matériels, des blessures ou la mort.
PB HEAT, LLC
131 S. CHURCH ST • BALLY, PA 19503
X8229 R0 (10/15-1M)
Printed in U.S.A.
©2015 PB Heat, LLC. All rights reserved.
WARNING
MISE EN GARDE
2
Basic Operation
A. Lighting Instructions: For proper lighting procedures, refer to the Burner Manual supplied by the
burner manufacturer.
B. Inspection of Heating Surfaces: The boiler’s internal heating surfaces should be inspected annually
before each heating season for excessive corrosion and sooting. If excessive scaling or soot is found, contact a qualified service technician. To access the flueways follow the steps below.
SC/SCT
1. Turn off all electrical power to the boiler and allow the boiler to cool.
2. If inspecting from the side remove the left jacket panel and side clean-out cover plates. If inspecting from the top, remove the flue pipe, left top jacket panel and flue collector.
3. Visually inspect the flueways and pins for scaling and excessive soot deposits. Check that all ropes seals or gaskets are in good condition.
4. Replace the clean-out covers and jacket panel (side) or the flue collector, top left jacket panel, and flue pipe (top).
5. Return power to the boiler.
LC/LCE
1. Turn off all electrical power to the boiler and allow the boiler to cool.
2. Remove the Jacket Middle Front Panel and the Jacket Top Panels. Remove the Front Cleanout Plate and Cleanout Cover Plates on each flueway. On LCE boilers, remove the top flue outlet plate and vent piping as necessary to access the top of the sections.
3. Visually inspect the flueways and pins for scaling and excessive soot deposits. Check that all ropes seals or gaskets are in good condition.
4. Replace the clean-out covers and jacket panels. On LCE boilers replace the top flue outlet plate and any vent piping.
5. Return power to the boiler.
C. Inspection: All of the boiler components and system should be inspected annually by a qualified
service agency to ensure continued safe operation.
- Always keep the oil supply valve shut-off if the burner is shut down for an extended period.
Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency.