Single--Packaged Products with Energy-- Saving Features and
R--410A refrigerant.
S Up to 13.5 SEER
S Up to 81% AFUE
S Factory--Installed TXV
S Multi--Speed Blower--Standard
S Direct Spark Ignition
S Low Sound Levels
FEATURES/BENEFITS
One-- piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
Easy Installation
Factory--assembled package is a compact, fully self--contained,
combination gas heating/electric cooling unit that is prewired,
pre--piped, and pre--charged for minimum installation expense.
These units are available in a variety of standard and optional
heating/ cooling size combinations with voltage options to meet
residential and light commercial requirements. Units are
lightweight and install easily on a rooftop or at ground level. The
high tech composite base eliminates rust problems associated with
ground level applications.
PY3G
SINGLE AND THREE PHASE
2--5 NOMINAL TONS (SIZES 024--060)
Convertible duct configuration
Unit is designed for easy use in either downflow or horizontal
applications. Each unit is easily converted from horizontal to
downflow with the two standard duct covers. Downflow operation
is easily provided in the field to allow vertical ductwork
connections. The basepan utilizes knockout style seals on the
bottom openings to ensure a positive seal in the horizontal airflow
mode.
Efficient operation High--efficiency designoffers SEER
(Seasonal Energy Efficiency Ratios) of up to 13.5 and AFUE
(Annual Fuel Utilization Efficiency) ratings as high as 80.4%.
Energy-- saving, direct spark ignition saves gas by operating only
when the room thermostat calls for heating. Standard units are
furnished with natural gas controls. A low--cost field installed kit
for propane conversion is available for all units.
PY3G have dedicated Low NOx units designed for California
installations. These models meet the California maximum oxides of
nitrogen (NOx) emissions requirement of 40 nanograms/joule or
less as shipped from the factory and MUST be installed in
California Air Quality Management Districts where a Low NOx
rule exists. Low NOx option is available on single phase models
only.
Durable, dependable components Compressors are designed
for high efficiency. Each compressor is hermetically sealed against
contamination to help promote longer life and dependable
operation. Each compressor also has vibration isolation to provide
quieter operation. All compressors have internal high pressure and
overcurrent protection.
Monoport inshot burners produce precise air--to--gas mixture,
which provides for clean and efficient combustion. The large
monoport on the inshot (or injection type) burners seldom, if ever,
requires cleaning. All gas furnace components are accessible in one
compartment.
Turbo--tubulart heat exchangers are constructed of aluminized
steel for corrosion resistance and optimum heat transfer for
improved efficiency. The tubular design permits hot gases to make
multiple passes across the path of the supply air.
In addition, dimples located on the heat exchanger walls force the
hot gases to stay in close contact with the walls, improving heat
transfer.
Direct--drive high efficiency brushless DC multi--speed blower
motor is standard on all PY3G models.
Direct-- drive PSC condenser-- fan motors are designed to help
reduce energy consumption and provide for cooing operation
downto40_F(4.4_C) outdoor temperature. Motormasterr II low
ambient kit is available as a field--installed accessory.
Thermostatic Expansion Valve -- A hard shutoff, balance port
TXV maintains a constant superheat at the evaporator exit (cooling
cycle) resulting in higher overall system efficiency.
Refrigerant system is designed to provide dependability. Liquid
filter driers are used to promote clean, unrestricted operation. Each
unit leaves the factory with a full refrigerant charge. Refrigerant
service connections make checking operating pressures easier.
1
High and Low Pressure Switches provide added reliability for the
compressor.
Indoor and Outdoor coils are computer--designed for optimum
heat transfer and efficiency. The indoor coil is fabricated from
copper tube and aluminum fins and is located inside the unit for
protection against damage. The outdoor coil is internally mounted
on the top tier of the unit. Copper fin coils and pre--coated fin coils
are available from the factory by special order. These coils are
recommended in applications where aluminum fins are likely to be
damaged due to corrosion. They are ideal for seacoast applications.
Low sound ratings ensure a quiet indoor and outdoor
environment with sound ratings as low as 75dBA.
Easy to service cabinets provide easy single--panel accessibility to
serviceable components during maintenance and installation. The
basepan with integrated drain pan provides easy ground level
installation with or without a mounting pad. Convenient handholds
are provided to manipulate the unit on the jobsite. A nesting feature
ensures a positive basepan to roof curb seal when the unit is roof
mounted. A convenient 3/4-- in. (19.05 mm) wide perimeter flange
makes frame mounting on a rooftop easy.
Standard metal duct covers with insulation come with the unit
and cover the horizontal duct openings. These can be left in place if
the units are converted to downflow.
Integrated Gas Control (IGC) board provides safe and efficient
control of heating and simplifies trouble--shooting through its
built--in diagnostic function.
Cabinets are constructed of heavyduty, phosphated, zinc--coated
prepainted steel capable of withstanding 500 hours in salt spray.
Interior surfaces of the evaporator/heat exchanger compartment are
insulated with cleanable semi--rigid insulation board, which keeps
the conditioned air from being affected by the outdoor ambient
temperature and provides improved indoor air quality. (Conforms
to American Society of Heating, Refrigeration andAir
Conditioning Engineers 62.2.) The sloped drain pan minimizes
standing water in the drain. An external drain is provided.
ARI Capacities4....................................
P h y s ic a l D a t a5 --- 6..................................
Options and Accessories7...........................
Base Unit Dimensions9---10.........................
d B --- Sound Levels (decibels)
db—Dry Bulb
SEER—Seasonal Energy Efficiency Ratio
wb—Wet Bulb
COP---Coefficient of Performance
* Air Conditioing & Refrigeration Institute.
**At “A” conditions---80_F (26.7_C) indoor db/67_F (19.4_C) indoor wb &
95_F(35_C) outdoor db.{ Rated in accordance with U.S. Government DOE Department of Energy)
test procedures a nd/or ARI Standards 210/240.
PY3G
Gas Heating Capacities and Efficiencies
UNIT PY3GHEATING INPUT (Btuh)
024040
030040
024060
030060
036060
042060
036090
042090
048090
060090
048115
060115
048130
060130
LEGEND
AFUE—Annual Fuel Utilization Efficiency
NOTE: Before pu rchasing this appl iance, read impor tant en ergy cost and efficiency information available from your retailer.
40,00032,000
60,000
90,000
115,00093,000
130,000103,000
NET COOLING
CAPACITIES (Btuh)
Notes:
1. Ratings are net values, reflecting the effects of circulating fan heat.
Ratings are based on:
Cooling Standard: 80°F (26.7_C) db, 67°Fwb (19.4_C ) in d o o r e n t e r i n g --- a i r
temperature and 95°Fdb(35_C) outdoor entering---air temperature.
2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
*Based on altitude of 0 to 2000 ft ( 0 ---610 m).
{ Required filter sizes shown are based on the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity
of 300 ft/minute for throwaway type. Air filter pressure drop for non --- standard filters must not exceed 0.08 IN. W.C.
} If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity.
** For 460 volt units, a dd 14 lbs ( 6.35 kg) to the shipping weight.
(mm)
329
149
4.8
2.2
1..21
10.2
2800
24
609.6
1/5 (810)
2...17
3.7
800
10x10
254x254
1/2 (1050)
2...44
2...55
20x20x1
508x508x25
329
149
4.8
2.2
1...21
10.2
2800
24
609.6
1/5 (810)
2...17
3.7
800
10x10
254x254
1/2 (1050)
2...38
2...53
334
152
6.2
2.8
1...21
11.9
3000
24
609.6
1/5 (810)
3...17
3.7
1000
10x10
254x254
1/2 (1050)
2...44
2...55
20x24x1
508x610x25
334
152
6.2
2.8
1...21
11.9
3000
24
609.6
1/5 (810)
3...17
3.7
1000
10x10
254x254
1/2 (1050)
2...38
2...53
650 +/-- 15
420 +/-- 25
45 +/-- 10
Scroll
1
20 +/-- 5
344
156
6.4
2.9
1...21
15.4
3200
24
609.6
1/5 (810)
3...17
3.7
1200
11x10
279.4x254
3/4 (1000)
2...38
2...53
344
156
6.4
2.9
1...21
15.4
3200
24
609.6
1/5 (810)
3...17
3.7
1200
11x10
279.4x254
3/4 (1000)
3...38
3...53
610x762x25
24x30x1
435
197
6.1
2.7
1...21
13.6
3600
26
660.4
1/5 (810
3...17
4.7
1400
11x10
279.4x254
3/4 (1075)
2...38
2...53
435
197
6.1
2.7
1...21
13.6
3600
26
660.4
1/5 (810)
3...17
4.7
1400
11x10
279.4x254
3/4 (1075)
3...38
3...53
PY3G
5
PHYSICAL DATA (CONT)
1600
1600
1600
1750
1750
UNIT SIZE048090048115048130060090060115060130
NOMINAL CAPACITY (ton)444555
SHIPPING WEIGHT** lb
SHIPPING WEIGHT** kg
COMPRESSORS
Quantity
REFRIGERANT (R ---410A)
Quantity lb
Quantity (kg.)
REFRIGERANT METERING DEVICETXV
OUTDOOR COIL
Rows...Fins/in.
Face Ar ea ( sq ft)
OUTDOOR FAN
Nominal Cf m
Diameter in.
Diameter (mm)
Motor Hp (Rpm)
*Based on altitude of 0 to 2000 ft ( 0 ---610 m).
{ Required filter sizes shown are based on the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity
of 300 ft/minute for throwaway type. Air filter pressure drop for non --- standard filters must not exceed 0.08 IN. W.C.
} If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity.
** For 460 volt units, a dd 14 lbs ( 6.35 kg) to the shipping weight.
443
201
6.4
2.9
1...21
15.5
4000
26
660.4
1/5 (810)
3...17
4.7
16001600160017501750
11x10
279.4x254
1.0 (1075)
3...38
3...53
443
201
6.4
2.9
1...21
15.5
4000
26
660.4
1/5 (810)
3...17
4.7
11x10
279.4x254
1.0 (1075)
3...33
3...51
443
201
6.4
2.9
1...21
15.5
4000
26
660.4
1/5 (810)
3...17
4.7
11x10
279.4x254
1.0 (1075)
3...31
3...49
Scroll
1
650 +/-- 15
420 +/-- 25
20 +/-- 5
45 +/-- 10
24x36x1
610x914x25
465
211
10.0
4.5
2...21
15.5
3200
26
660.4
1/5 (810)
3...17
5.7
11x10
279.4x254
1.0 (1040)
3...38
3...53
465
211
10.0
4.5
2...21
15.5
3200
26
660.4
1/5 (810)
3...17
5.7
11x10
279.4x254
1.0 (1040)
3...33
3...51
465
211
10.0
4.5
2...21
15.5
3200
26
660.4
1/5 (810)
3...17
5.7
1750
11x10
279.4x254
1.0 (1040)
3...31
3...49
6
OPTIONS AND ACCESSORIES
Field--installed accessories
Economizer with Solid --State Controls and Barometric
Relief Dampers
Manual Air Damper (25% open)
Filter Rack
Flat Roof Curbs (8-- in. [203.2 mm] and 14 --in. [355.6 mm])
Square--to --Round Duct Transition Kit
Thermostats
Crankcase Heater
Compressor Start Kit (for use on single--phase units only)
Natural--to--propane Gas Conversion Kit
High Altitude P ropane Conversion Kit
Propane--to --natural Gas Conversion Kit
Rigging Kit
Low Ambient Kit (Motormaster® II Control)
Solid--State Time Guard® II Device
Economizer with solid--state controls and barometric relief
dampers includes filter racks and provide outdoor air during
cooling and reduce compressor operation.
Manual outside air damper includes hood and filter rack with
adjustable damper blade for up to 25% outdoor air.
Flat roof curbs in both 8 in. (203.2 mm) and 14 in. (355.6 mm)
sizes are available for roof mounted applications.
Square--to--round duct transition kit enables 024--048 size units
to be fitted to 14 in. (355.6 mm) round ductwork.
Compressor start kit assists compressor start--up by providing
additional starting torque on single phase units and prolongs
compressor motor life.
Corporate Thermostats provide control for the system heating
and cooling functions. Thermostat models are available in both
programmable and non--programmable versions.
Crankcase heater provides anti--floodback protection for
low--load cooling applications.
Natural--to--propane gas conversion kit allows for conversion
from natural gas to propane gas for standard altitude (0 to 2000 ft
[0 to 610 m] above sea level).
Rigging kit includes lifting brackets which are inserted into the
unit base rigging holds to lift unit for rooftop applications.
Low--ambient kit (Motormaster II control) allows the use of
mechanical cooling down to outdoor temperatures as low as 0_F
(-- 18_C) when properly installed.
Solid-- state Time Guard II device provides short--cycling
protection for the compressor. Not required with corporate
electronic thermostats.
Filter rack features easy installation, serviceability, and
high--filtering performance for vertical applications.
High altitude propane conversion kit is for use at 2001 to 6000
ft (610 to 1829 m) above sea level. Kit consists of propane gas
orifices that compensate for gas heat operation at high altitude.
Propane--to--natural conversion kit is for use at standard
altitudes (0 to 2000 ft [0 to 610 m] above sea level). Kit contains
natural gas orifices and gas valve spring to convert the unit back to
natural gas.
PY3G
7
COIL
BASE
FILTER
ECONOMIZER
FILTER ACCESS DOOR
(HORIZONTAL
APPLICATION ONLY.)
DO NOT REMOVE
FROM DOWNFLOW
DISCHARGE.
6. When unit moun ting screw is used (see Note A), a retainer bracket must be used as well. T his bracket must also be used when required by code for hurr ican eorseismic
conditions. This bracket is available through Micrometl.
A05308
G
IN. (MM)
11
SELECTION PROCEDURE (WITH EXAMPLE)
1. Determine cooling and heating requirements at
design conditions:
2. Select unit based on required cooling capacity.
Enter Net Cooling Capacities table at condenser entering
temperature of 95°F(35°C). Unit 036 at 1200 cfm and 67°F
(19°C) ewb (entering wet bulb) will provide a total capacity of
34,400 Btuh and a SHC of 25,900 Btuh. Calculate SHC correction,
PY3G
if required, using Note 4 under Cooling Capacities tables.
3. Select heating capacity of unit to provide design
condition requirement.
In the Heating Capacities and Efficiencies table, note that the unit
036090 will provide 72,000 Btuh with an input of 90,000 Btuh.
4. Determine fan speed and power requirements at
design conditions.
Before entering the air delivery tables, calculate the total static
pressure required. From the given example, the Wet Coil Pressure
Drop T able, and the Filter Pressure Drop Table:
External Static Pressure0.300 IN. W.C.
Filter0.130 IN. W.C.
Wet Coil Pressure Drop0.100 IN. W
Total Static Pressure0.530 IN. W.C
Enter the table for Dry Coil Air Delivery—Horizontal and
Downflow Discharge. At .530 IN. W.C. ESP, the closest speed to
1200 CFM is Med--High (orange wire), which delivers 1316 CFM
at .6 in ESP.
.C
5. Select unit that corresponds to power source
available.
The Electrical Data Table shows that the unit is designed to operate
at 230--1--60.
*At75°F(24°C) entering dry bulb ---Tennessee Valley Authority (TVA) rating conditions; all others at 80°F(27°C) dry bulb.
LEGEND
BF— Bypass Factor
edb— Entering Dry--- Bulb
Ewb— Entering Wet---Bulb
kW — Total Unit Power Input
SHC— Sensible Heat Capacity (1000 Btuh)
TC — Total Capacity (1000 Btuh) (n et)
rh—Relative Hu midity
COOLING NOTES:
1. Ratings are net; they account for the effects of the evaporator--- fan motor power and heat.
2. Direct interpolation is permissible. Do not extrapolate.
3. The following formulas may be used:
t
ldb =tedb
Wet---bulb temperature corresponding to enthalpy
t
lwb =
air leaving evaporator coil (
h
lwb =he w b ---
h
ewb = Enthalpy of air entering evaporator coil
Where:
4. The SHC is based on 80_F (26.6_C) edb temperature of air entering
evaporator coil. Below 80_F (26.6_C) edb, subtract (corr factor x cfm) from
SHC.
Above 80_F (26.6_C) edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 + BF) x (edb --- 80).
5. Integrated capacity is maximum (instantaneous) capacity less the effect
of frost on the outdoor coil and the heat required to defrost it.
---
Sensible capacity
1.10 x cfm
total capacity (Btuh)
4.5 x cfm
h
(Btuh)
lwb)
PY3G
19
PERFORMANCE DATA (CONT)
Dry Coil Air Delivery* -- Horizontal and Downflow Discharge -Unit PY3G024--060
NA --- Not allowed for hea ting speed
Note: Deduct field--- supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting.
Economizer 1--in. (25 mm) Filter Pressure Drop (IN. W.C.)
UNIT PY3GPRESSURE DROP
024--- 0360.20
042--- 0600.25
GAS ADJUSTMENT
Natural Gas Orifice Sizes and Manifold Pressure
NAMEPLATE
INPUT (Btu/hr)
40,000
60,000
90,000
115,000
130,000
* For Canadian Installations from 2000 ---4500 ft (610 --- 1372 m), use U.S.A. column 2001 ---3000 ft (610 --- 914 m).
† Orifices availabl e through your distributor
Note: Orifice sizes and manifold pressure settings are based on natural gas with a heating value of 1050 Btu/ft3 amd a specific gravity of .65.
ALTITUDE OF INSTALLATION (FT. ABOVE SEA LEVEL) U.S.A.*
2001 --- 3000*{
(610--- 914 m)
3001 --- 4000{
(915--- 1219 m)
4001 --- 5000{
(1220--- 1524 m)
(1524--- 1829 m)
25
5001 --- 6000{
TYPICAL PIPING AND WIRING
ROOF-MOUNTING
CURB
ROOF
RETURN-AIR
FLEXIBLE DUCT
PY3G
SUPPLY-AIR
FLEXIBLE DUCT
CONCENTRIC DIFFUSER BOX
(FIELD-SUPPLIED)
RETURN
AIR
CEILING
A09607
INDOOR
THERMOSTAT
TOP COVER
26
FROM
GAS LINE
*NEC - NATIONAL ELECTRICAL CODE
FROM
POWER
SOURCE
DISCONNECT
PER NEC*
A09608
APPLICATION DATA
Condensate trap — A 2--in. (51 mm) condensate trap must be
field supplied.
Ductwork — Secure downflow discharge ductwork to roof curb.
For horizontal discharge applications, attach ductwork to unit with
flanges.
To convert a unit to downflow discharge — Units are equipped
with factory--installed inserts in the down--flow openings. Removal
of the inserts is similar to removing an electrical knock--out. Use
the duct cover to seal the horizontal discharge openings in the unit.
Units installed in horizontal discharge orientation do not require
duct covers.
Airflow — Units are draw--thru in the cooling mode and
blow--thru in the heating mode.
Maximum cooling airflow — To minimize the possibility of
condensate blow--off from the evaporator, airflow through the units
should not exceed 450 cfm per ton.
Minimum cooling airflow — Minimum cooling airflow is 350
cfm per ton.
Minimum ambient cooling operation temperature —All
standard units have a minimum ambient operating temperature of
40_F(4_C). With accessory low ambient temperature kit, units can
operate at temperatures down to 0_F(--18_C).
Minimum temperature — Air entering the heat exchanger in
heating mode must be a minimum of 50_F(10_C) continuous
and/or 45_F(7_C) intermittent.
1. In compliance with NEC (National Electrical Code) requirements
for multimotor and combination load equipment (refer to NE C
Articles 430 and 440), the overcurrent protective device for the
unit shall be Power Supply fuse. The CGA (Canadian Gas
Association) units may be fuse or circuit break er.
2. Minimum wire size is based on 60 C copper wire. I f other than
60 C wire is used, or if length exceeds wire length in table,
determine siz e from NEC..
3. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater than 2%.
the percentage of voltage imbalance.
Use the following formula to determine
% Voltage imbalance
= 100 x
max voltage deviation from average voltage
average voltage
VOLTAGE RANGECOMPRESSOROFMIFMIDMPOWER SUPPLY
MINMAXRLALRAFLAFLAFLAMCAMOCP**
12.858.31.24.10.721.330.
8.458.01.24.10.715.820.
5.838.00.53.00.710.715.
EXAMPLE: Supply voltage is 230-3-60.
AB = 228 v
BC = 231 v
(R)
AC = 227 v
Average Voltage =
228 + 231 + 227
3
686
=
3
= 229
Determine maximum deviation from average voltage.
(AB) 229 (BC) 231 (AC) 229 -
228 =1v
229 =2v
227 =2v
Maximum deviation is 2 v.
Determine percent of voltage imbalance.
% Voltage Imbalance = 100 x
2
229
= 0.8%
This amount of phase imbalance is satisfactory as it is below the
maximum allowable 2%.
IMPORTANT: If the supply voltage phase imbalance is
more than 2%, contact your local electric utility company
immediately.
A06564
28
TYPICAL WIRING SCHEMATIC 208/230--1--60
PY3G
A08052
29
TYPICAL WIRING SCHEMATIC 208/230--3--60
PY3G
A08053
30
TYPICAL WIRING SCHEMATIC 460--3--60
PY3G
A08010
31
CONTROLS
Operating sequence
Heating -- On a call for heating, terminal W of the thermostat is
energized, starting the induced--draft motor. When the pressure
switch senses that the induced--draft motor is moving sufficient
combustion air, the burner sequence begins. This function is
performed by the integrated gas unit controller (IGC). The indoor
(evaporator)--fan motor is energized 45 sec after flame is
established. When the thermostat is satisfied and W is
de--energized, the burners stop firing and the indoor (evaporator)
fan motor shuts off after a 45--sec time--off delay. Please note that
the IGC has the capability to automatically reduce the indoor fan
motor on delay and increase the indoor fan motor off delay in the
event of high duct static and/or partially--clogged filter.
Cooling — When the system thermostat calls for cooling, 24 V is
supplied to the “Y” and “G” terminals of the thermostat. This
completes the circuit to the contactor coil (C) and indoor
(evaporator) fan relay (IFR). The normally open contacts of
energized C close and complete the circuit through compressor
PY3G
motor (COMP) to outdoor (condenser) fan motor (OFM). Both
motors start instantly. The set of normally open contacts of
energized IFR close and complete the circuit through IFM. The
IFM starts instantly.
On the loss of the thermostat call for cooling, 24 V is removed
from both the “Y” and “G” terminals (provided the fan switch is in
the “AUTO” position) de--energizing the compressor contactor and
opening the contacts supplying power to compressor/OFM. After a
60--second delay, the IFM shuts off. If the thermostat fan selector
switch is in the “ON” position, the IFM will run continuously.
NOTE: On units with a Time Guard
compressor has started and then stopped, it cannot be restarted
again until 5 minutes have elapsed.
®
II device: Once the
32
GUIDE SPECIFICATIONS
Packaged Gas Heating/Electric Cooling Units
Constant Volume Application
HVAC Guide Specifications
Size Range:2to5Tons,NominalCooling
40,000 to 130,000 Btuh,
Nominal Heating Input
Model Number: PY3G
Part 1 — General
SYSTEM DESCRIPTION
Outdoor rooftop mounted, gas heating/electric cooling unit
utilizing a hermetic scroll compressor for cooling duty. Unit
shall discharge supply air vertically or horizontally as shown
on contract drawings. Condenser fan/coil section shall have a
draw--thru design with vertical discharge for minimum sound
levels.
QUALITY ASSURANCE
A. Unit shall be rated in accordance with ARI Standards 210/240
and 270.
B. Unit shall be designed in accordance with UL Standard 1995
and ANSI Z21.47/CSA 2.3.
C. Unit shall be manufactured in a facility registered to ISO 9001
manufacturing quality standard.
D. Unit shall be UL listed and c--UL certified as a total package
for safety requirements.
E. Roof curb shall be designed to conform to NRCA Standards.
F. Insulation and adhesives shall meet NFPA 90.1 requirements
for flame spread and smoke generation.
G. Cabinet insulation shall meet ASHRAE Standard 62.2.
DELIVERY, STORAGE AND HANDLING
Unit shall be stored and handled per manufacturer’s
recommendations.
Part 2 — Products
EQUIPMENT
A. General:
Factory--assembled, single--piece, heating and cooling unit.
Contained within the enclosure shall be all factory wiring, piping,
controls, refrigerant charge with R--410A refrigerant, and special
features required prior to field start--up.
B. Unit Cabinet:
1. Unit cabinet shall be constructed of phosphated,
zinc--coated, pre--painted steel capable of with--standing 500
hours in salt spray.
2. Normal service shall be through a single removable cabinet
panel.
3. The unit shall be constructed on a rust proof unit base that
has an externally trapped, integrated sloped drain.
4. Evaporator fan compartment top surface shall be insulated
with a minimum 1/2--in. (12.7 mm)thick, flexible
fiberglass insulation, coated on the air side and retained by
adhesive and mechanical means. The evaporator wall
sections will be insulated with a minimum semi--rigid foil-faced board capable of being wiped clean. Aluminum foil-faced fiberglass insulation shall be used in the entire indoor
air cavity section.
5. Unit shall have a field--supplied condensate trap.
C. Fans:
1. The evaporator fan shall be a multi--speed, direct-- drive, as
shown on equipment drawings.
2. Fan wheel shall be made from steel, be double-- inlet type
with forward curved blades with corrosion resistant finish.
Fan wheel shall be dynamically balanced.
3. Condenser fan shall be direct drive propeller type with aluminum blades riveted to corrosion resistant steel spiders, be
dynamically balanced, and discharge air vertically.
D. Compressor:
1. Fully hermetic compressors with factory--installed vibration
isolation.
2. Scroll compressors shall be standard on all units.
E. Coils:
Evaporator and condenser coils shall have aluminum plate fins
mechanically bonded to seamless copper tubes with all joints
brazed (Copper/copper and vinyl--coated construction
available as option). Tube sheet openings shall be belled to
prevent tube wear.
F. Heating Section:
1. Induced-- draft combustion type with energy saving direct
spark ignition system and redundant main gas valve.
2. Induced-- draft motors shall provide adequate airflow for
combustion.
3. The heat exchangers shall be constructed of aluminized steel
for corrosion resistance.
4. Burners shall be of the in--shot type constructed of
aluminum coated steel.
5. All gas piping and electric power shall enter the unit cabinet
at a single location.
G. Refrigerant Components:
Refrigerant expansion device shall be of the TXV
(thermostatic expansion valve) type.
H. Filters:
Filter section shall consist of field--installed, throwaway, 1--in.
(25 mm) thick fiberglass filters of commercially available
sizes.
I. Controls and Safeties:
1. Unit controls shall be complete with a self--contained low
voltage control circuit.
2. Compressors shall incorporate a solid--state compressor
protector that provides reset capability.
J. Operating Characteristics:
1. Unit shall be capable of starting and running at 125_F
_C) ambient outdoor temperature per maximum load
(51
criteria of ARI Standard 210.
2. Compressor with standard controls shall be capable of operationdownto40_F(4_C) ambient outdoor temperature.
3. Units shall be provided with fan time delay to prevent cold
air delivery before the heat exchanger warms up.
4. Unit shall be provided with 60-- second fan time delay after
the thermostat is satisfied.
K. Electrical Requirements:
All unit power wiring shall enter the unit cabinet at a single
location.
L. Motors:
1. Compressor motors shall be of the refrigerant-- cooled type
with line--break thermal and current overload protection.
2. All fan motors shall have permanently lubricated bearings,
and inherent, automatic reset, thermal overload protection.
3. Condenser fan motor shall be totally enclosed.
PY3G
33
GUIDE SPECIFICATIONS (CONT)
M. Special Features Available:
1. Coil Options:
Shall include factory--installed optional copper/copper and
vinyl-- coated refrigerant coils.
2. Economizer:
a. Economizer controls capable of providing free cooling
using outside air.
b. Equipped with low leakage dampers not to exceed 3%
leakage, at 1.0 IN. W.C. pressure differential.
c. Spring return motor shuts off outdoor damper on power
failure.
3. Flat Roof Curb:
Curbs shall have seal strip and a wood nailer for flashing
and shall be installed per manufacturer’s instructions.
4. Manual Outdoor Air Damper:
Package shall consist of damper, birdscreen, and rainhood
which can be preset to admit outdoor air for year--round
PY3G
ventilation.
5. Thermostat:
To provide for one--stage heating and cooling in addition
manual or automatic changeover and indoor fan control.
6. Natural--to--Propane Conversion Kit:
Shall be complete with all required hardware to convert to
propane gas operation at 10.0 IN. W.C. manifold pressure.
7. Propane-- to--Natural Conversion Kit
Shall be complete with all hardware to convert to natural
gas at standard altitude (0 to 2000 ft [0 to 610 m] above sea
level).
8. Low Ambient Package:
Shall consist of a solid--state control and condenser coil
temperature sensor for controlling condenser--fan motor operation, which shall allow unit to operate down to 0_F
(-- 17_C) outdoor ambient temperature when properly
installed.
9. Filter Rack Kit:
Shall provide filter mounting for downflow applications.
10. Square-- To--Round Duct Transitions (024--048):
Shall have the ability to convert the supply and return openings from rectangular to round.
11. Compressor Protection:
Solid-- state control shall protect compressor by preventing
“short cycling.“
12. Crankcase Heater:
Shall provide anti--floodback protection for low--load cooling applications.
13. High Altitude Propane Conversion Kit:
Shall consist of all required hardware to convert ot propane
gas heat operation at 2001 to 6000 ft (610 to 1829 m) above
sea level.
14. Low NOx:
Shall provide NOx reduction to values below 40 nanograms/joule to meet California emission requirements as
shipped from factory.
15. Compressor Start Kit (single phase units only):
Shall provide additional starting torque for single--phase
compressors.
E2009 Payne Heating & Cooling Systems D7310 W. Morris St. D Indianapolis, IN 46231Printed in U.S.A.Edition Date: 11/09
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
34
C a t a l o g N o : S S --- P Y 3 G --- 0 2
Replaces: NEW