The two--stage gas valve is at the heart of the comfort provided by
this furnace, along with the variable--speed ECM blower motor,
and two--speed inducer motor. With an Annual Fuel Utilization
Efficiency (AFUE) up to 96.0%, the two--stage gas furnace
provides exceptional savings as well when compared to standard
gas furnaces. This furnace also features 4--way multipoise
PG96VAT
TWO--STAGE, 4--WAY MULTIPOISE
VARIABLE--SPEED
CONDENSING GAS FURNACE
installation flexibility, and is available in six model sizes. The
PG96VAT can be vented for direct vent/two--pipe, ventilated
combustion air, or single--pipe applications. All units meet
California Air Quality Management District emission requirements.
All sizes are design certified in Canada.
STANDARD FEATURES
S All sizes meet ENERGY STARR Version 4.0 criteria for gas
furnaces: 95+AFUE; AMACF electrical rating; 2% or less
cabinet airflow leakage.
S Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
S Silicon Nitride Hot Surface Igniter.
S 4--way multipoise design for upflow, downflow or horizontal
installations, with unique vent elbow and optional through-the--cabinet downflow venting capability.
S Full--featured variable--speed blower motor, two--speed inducer
motor, and two--stage gas valve.
S Self--diagnostics.
S Adjustable blower speed for cooling, continuous fan, and
dehumidification.
S Aluminized--steel primary heat exchanger.
S Stainless--steel condensing secondary heat exchanger.
S Propane convertible (See Accessory list).
S Factory--configured ready for upflow applications.
S Fully--insulated casing including blower section.
S Convenient Air Purifier and Humidifier connections.
S Direct--vent/sealed combustion, single--pipe venting or
ventilated combustion air.
S Installation flexibility: sidewall or vertical vent.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1--in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
CERTIFIED
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
{Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.
‡Minimum heat CFM when low --- heat rise adjustment switch (SW 1 --- 3) and comfor t/efficiency adjustment switch (SW1 --- 4) on control center are OFF.
ESP --- External Static Pressure
RATED HEATING OUTPUT{
(BTUH)
CFM‡
(Low
Heating)
HEATING
CFM
(High
Heating)
Rated
High
Heating
ESP
COOLING
CFM @ 0.5
ESP
MOTOR HP
(VARIABLE
SPEED)
APPROX.
SHIP WT.
(LB)
Dual Fuel System Compatibility — This system can provide
more control over your monthly energy bills by automatically
selecting the most economical method of heating. Our system
automatically switches between the gas furnace and the electric
heat pump as outside temperatures change to maintain greater
efficiency and comfort than with any traditional single-source
PG96VAT
heating system. The heat pump also delivers high-efficiency
coolinginthesummer.
Robust Igniter — Payne’s unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further enhances
the gas furnace reliability and continues Payne’s tradition of
technology leadership and innovation in providing a reliable and
durable product.
Reliable Heat Exchanger Design — The aluminized steel, clam
shell primary heat exchanger was re--engineered to achieve greater
efficiency out of a smaller size. The first two passes of the heat
exchanger are based on the current 80% product, a design with
more than ten years of field-proven performance and success.
These innovations, paired with the continuation of a crimped,
no-weld seam create an efficient, robust design for this essential
component.
The condensing heat exchanger, a stainless steel fin and tube
design, is positioned in the furnace to extract additional heat.
Stainless steel coupling box componentry between heat exchangers
has exceptional corrosion resistance in both natural gas and
propane applications.
4-Way Multipoise Design — One model for all applications –
there is no need to stock special downflow or horizontal models
when one unit will do it all. The new heat exchanger design allows
these units to achieve the certified AFUE in all positions.
Direct or Single-pipe Venting, or Optional Ventilated
Combustion Air — This furnace can be installed as a 2-pipe
(Direct Vent) furnace, in an optional ventilated combustion air
application, or in single-pipe, non-direct vent applications. This
provides added flexibility to meet diverse installation needs.
Sealed Combustion System — This furnace brings in combustion
air from outside the furnace when installed as a direct vent or
ventilated combustion air venting system, which results in
especially quiet operation. By sealing the entire combustion
vestibule, the entire furnace can be made quieter, not just the
burners.
Monoport Burners — The burners are specially designed and
finely tuned for smooth, quiet combustion and economical
operation.
Bottom Closure — Factory--installed for side return; easily
removable for bottom return. The multi-use bottom closure can
also serve for roll-out protection in horizontal applications, and act
as the bottom closure for the optional return air base accessory.
Blower Access Panel Switch — Automatically shuts off 115-v
power to furnace whenever blower access panel is opened.
Quality Registration — Our furnaces are engineered and
manufactured under an ISO 9001 registered quality system.
Certifications — This furnace is CSA (AGA and CGA) design
certified for use with natural and propane gases. The furnace is
factory--shipped for use with natural gas. A CSA listed gas
conversion kit is required to convert furnace for use with propane
gas. The efficiency is AHRI efficiency rating certified. This furnace
meets California Air Quality Management District emission
requirements.
2
SPECIFICATIONS
Heating Capacity and Efficiency300404206048080600806010066120
Input
Output
EfficiencyAFUE % (ICS)96.096.096.096.096.096.0
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data300404206048080600806010066120
Rated External Static
Pressure (in. w.c.)
Airflow Delivery @ Rated ESP (CFM)
Cooling Capacity (tons)
Direct-Drive Motor TypeElectronically Commutated Motor (ECM)
Direct-Drive Motor HP1/23/43/4111
Motor Full Load Amps6.88.48.410.910.910.9
RPM Range600 - 1200
Speed SelectionsVariable (PWM)
Blower Wheel Dia x Widthin.11 x 711 x 811 x 811 x 1011 x 1011 x 11
Air Filtration SystemField Supplied
Filter Used for Certified Watt Data*KGAWF**06UFR
High Heat(BTUH)40,00060,00080,00080,000100,000120,000
Low Heat(BTUH)26,00039,00052,00052,00065,00078,000
High Heat(BTUH)39,00058,00078,00078,00097,000117,000
Low Heat(BTUH)25,00038,00050,00051,00063,00076,000
Input VoltageVolts-Hertz-Phase115-60-1
Operating Voltage RangeMin-Max104 - 127
Maximum Input AmpsAmps7.59.29.211.711.811.8
Unit AmpacityAmps10.312.412.415.515.615.6
Minimum Wire SizeAWG141414121212
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)40 VA
External Control Power Available
Controls300404206048080600806010066120
Gas Connection Size1/2" - NPT
Burners (Monoport)234456
Gas Valve (Redundant)ManufacturerWhite Rogers
Minimum Inlet Gas pressure (in. wc)4.5
Maximum Inlet Gas pressure (in. wc)13.6
Gas Conversion Kit - Natural to PropaneKGANP5201VSP
Gas Conversion Kit - Propane to NaturalKGAPN4401VSP
Manufactured (Mobile) Home Kitnot approved for MH use
Ignition DeviceSilicon Nitride
Limit Control165180170200180160
Heating Blower Control (Heating Off-Delay)Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay)90 seconds
Communication SystemNon-communicating
Thermostat ConnectionsR, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM
Accessory ConnectionsEAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
Freeze Protect Kit - Heat TapeKGAHT0101CFPDDDDDD
CPVC to PVC Drain Adapters - 1/2” CPVC to 3/4” PVCKGAAD0110PVCDDDDDD
Horizontal Trap Grommet - Direct VentKGACK0101HCKAll DV Horizon tal
Condensate Neutralizer KitP908---0001DDDDDD
External Trap KitKGAET0201ETKDDDDDD
Ductwork Adapter Accessories
Furnace Base Kit for Combustible FloorsKGASB0201ALLDDDDDD
Coil Adapter Kits --- No OffsetKGADA0101ALLDDDDDD
Coil Adapter Kits --- Single OffsetKGADA0201ALLDDDDDD
Coil Adapter Kits --- Double OffsetKGADA0301ALLDDDDDD
Return Air Base (Upflow Applications) 14.0 --- in. wideKGARP0301B14D
Return Air Base (Upflow Applications) 17.5 --- in. wideKGARP0301B17DD
Return Air Base (Upflow Applications) 21.0 --- in. wideKGARP0301B21DD
Return Air Base (Upflow Applications) 24.5 --- in. wideKGARP0301B24D
IAQ Device Du ct Adapters 20.0---in. IAQ to 16 in. Side ReturnKGAAD0101MEC20”x25” IAQ Devices
IAQ Device Du ct Adapters 24.0---in. IAQ to 16 in. Side ReturnKGAAD0201MEC24”x25” IAQ Devices
Gas Conversion Accessories
Gas Conversion Kit - Nat to LPKGANP50011SPDDDDDD
Gas Conversion Kit - L P to NatKGAPN42011SPDDDDDD
GasOrificeKit-#42(NatGas)LH32DB207DDDDDD
GasOrificeKit-#43(NatGas)LH32DB202DDDDDD
GasOrificeKit-#44(NatGas)LH32DB200DDDDDD
GasOrificeKit-#45(NatGas)LH32DB205DDDDDD
GasOrificeKit-#46(NatGas)LH32DB208DDDDDD
GasOrificeKit-#47(NatGas)LH32DB078DDDDDD
GasOrificeKit-#48(NatGas)LH32DB076DDDDDD
Gas Orifice Kit - #54 (LP)LH32DB203DDDDDD
Gas Orifice Kit - #55 (LP)LH32DB201DDDDDD
Gas Orifice Kit - #56 (LP)LH32DB206DDDDDD
Gas Orifice Kit - 1.25mm (LP)LH32DB209DDDDDD
Gas Orifice Kit - 1.30mm (LP)LH32DB210DDDDDD
IAQ Accessories
Filter Rack --- Side Return for 1” FiltersKGAFR0801SREDDDDDD
Filter Rack --- Bottom Return for 1” Filters --- 14.2” wideKGBFR0401B14D
Filter Rack --- Bottom Return for 1” Filters --- 17.5” wideKGBFR0501B17DD
Filter Rack --- Bottom Return for 1” Filters --- 21.0” wideKGBFR0601B21DD
Filter Rack --- Bottom Return for 1” Filters --- 24.5” wideKGBFR0701B24D
Filter Pack (6 pack) --- Washable - 16x25x1KGAWF1306UFRDDDDDD
Filter Pack (6 pack) --- Washable - 24x25x1KGAWF1506UFRDDDDDD
EZ-Flex Filter - 16” (406 mm)EXPXXFIL0016Use with EZXCAB ---1016
EZ-Flex Filter - 20” (508 mm)EXPXXFIL0020Use with EZXCAB ---1020
EZ-Flex Filter - 24” (610 mm)EXPXXFIL0024Use with EZXCAB ---1024
EZ-Flex Filter with End Caps - 16” (406 mm)EXPXXUNV0016Use with EZXCAB ---1016
EZ-Flex Filter with End Caps - 20” (508 mm)EXPXXUNV0020Use with EZXCAB ---1020
EZ-Flex Filter with End Caps - 24” (610 mm)EXPXXUNV0024Use with EZXCAB ---1024
Cartridge Media Filter - 16” (406 mm)FILXXCAR0016Use with FILCABXL---1016
Cartridge Media Filter - 20” (508 mm)FILXXCAR0020Use with FILCABXL---1020
Cartridge Media Filter - 24” (610 mm)FILXXCAR0024Use with FILCABXL---1024
D = Used with the model furnace
DESCRIPTIONPAR T NUM BE R300404206048080600806010066120
See Venting Tables
PG96VAT
5
AIR DELIVERY -- CFM
COOLING4AND HEATING AIR DELIVERY - CFM (Bottom Return5With Filter)
(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2.)
Unit SizeCooling Switch SettingsExternal Static Pressure (ESP)
1. Nominal 350 CFM/ton cooling airflow is del ivered with SW1-5 and SW4-3 set to OFF.
Set both SW1-5 and SW4-3 to ON for +7% airflow (nominal 370 CFM/ton).
Set SW1-5 to ON and SW4-3 to OFF for +15% airflow (nominal 400 CFM/ton).
Set SW4-3 to ON and SW1-5 to OFF for -7% airflow (nominal 325 CFM/ton).
The above adjustments in airflow are subject to motor horsepower range/capacity.
2. Maximum cooling airflow is achieved when switches SW2-1, SW2-2, SW2-3 and SW1-5 are set to ON, and SW4-3 is set to OFF.
3. All heating CFM's are when low heat rise adjustment switch (SW1-3) and comfort/efficiency adjustment switch (SW1-4) are both set to OFF.
4. Ductwork must be sized for high-heating CFM within the operational range of E.S.P. Operation within the blank areas of the chart is not recommended
because high-heat operation will be above 1.0 E.S.P.
5. All airflows of 1800 CFM or less on 21” and 24.5” casing size furnaces are 5% less on side retur n only installations.
6. Airflows over 1800 CFM require bottom return, two-side return, or bottom an d side retu rn. A minimum filter size of 20” x 25” is required.
7. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
8. Airflow not stable at this E.S.P.
High Heat Airflow
Low Heat Airflow
2
3
3
note 8237523002205211520101890175016451550
note 8237523002205211520101890175016451550
1735167516251560150014551395134512851225
7
NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from
Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 1 – Maximum Equivalent Vent Length -- Ft. (M)
0 to 4500 Ft. (0 to 1370 M) Altitude
DIRECT VENT (2 -PIPE) AND NON-DIRECT VENT (1-PIPE)
Vent Pipe Diameter (in.)
3
4
4
4
4
1-1/222-1/234
50(15.2)210(64.0)250(76.2)NA
NANA10(3.0)90(27.4)210(64.0)
NANANA80(24.4)185(56.4)
NANANA79(24.1)158(48.2)
NANANA69(21.0)146(44.5)
1
2
NA
ELBOW CONFIGURATIONSVENT TERMINAL CONFIGURATIONS
Concentric
Long
Medium
Mitered
Standard
A11580
Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M)
Pipe Diameter (in):1-1/222-1/234
Mitered 90º Elbow8(2.4)8(2.4)8(2.4)8(2.4)8(2.4)
Medium Radius 90º Elbow5(1.5)5(1.5)5(1.5)5(1.5)5(1.5)
Long Radius 90º Elbow3(0.9)3(0.9)3(0.9)3(0.9)3(0.9)
Mitered 45º Elbow4(1.2)4(1.2)4(1.2)4(1.2)4(1.2)
Medium Radius 45º Elbow2.5(0.8)2.5(0.8)2.5(0.8)2.5(0.8)2.5(0.8)
Long Radius 45º Elbow1.5(0.5)1.5(0.5)1.5(0.5)1.5(0.5)1.5(0.5)
Tee16(4.9)16(4.9)16(4.9)16(4.9)16(4.9)
Concentric Vent TerminationNA0(0.0)NA0(0.0)NA
Standard Vent Termination0(0.0)0(0.0)0(0.0)0(0.0)0(0.0)
8
Venting System Length Calculations
The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent
length of elbows used in the venting system from Table 2.
Standard vent terminations or factory accessory concentric vent terminations count for zero deduction.
See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that one
foot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe.
Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Tables 1 and 3.
Example 1
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M). Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, (2) 45_ long radius elbows and a factory accessory concentric vent
kit.
Can this application use 2--in. (50 mm ND) PVC/ABS DWV vent piping?
Measure the required linear length of air inlet and vent pipe; insert the
longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the
vent or inlet pipe)
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the
vent or inlet pipe)
Add equiv length of vent termination0ft.From Table 2
Add correction for flexible vent pipe, if any0ft.
Total Equivalent Vent Length (TEVL)112 ft.Add all of the above lines
Maximum Equivalent Vent Length (MEVL)127 ft.For 2” pipe from Table 1
Is TEVL less than MEVL?YESTherefore, 2” pipe may be used
3x3ft=9ft.From Table 2
2x1.5 ft=3ft.From Table 2
100 ft
Use length of the longer of the vent
or air inlet piping system
From Vent Manufacturer’s instructions;
zero for PVC/ABS DWV
Example 2
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M) Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, and a polypropylene concentric vent kit. Also includes 20 feet (6 M)
of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe.
Assume that one meter of flexible 60 mm or 80 mm polypropylene pipe equals 1.8 meters of PVC/ABS pipe. VERIFY FROM VENT
MANUFACTURER’S INSTRUCTIONS.
Can this application use 60 mm (O.D.) polypropylene vent piping? If not what size piping can be used?
Measure the required linear length of air inlet and vent pipe; insert the
longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the
vent or inlet pipe)
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the
vent or inlet pipe)
Add equiv length of vent termination9M x3ft/M=18 ft.From Vent Manufacturer’s instructions
Add correction for flexible vent pipe, if any1.8x20 ft=36 ft.From Vent Manufacturer’s instructions
Total Equivalent Vent Length (TEVL)163 ft.Add all of the above lines
3x3ft=9ft.From Vent Manufacturer’s instructions
0x=0ft.From Vent Manufacturer’s instructions
100 ft
Use length of the longer of the vent
or air inlet piping system
PG96VAT
Maximum Equivalent Vent Length (MEVL)127 ft.For 2” pipe from Table 1
Is TEVL less than MEVL?NO
Maximum Equivalent Vent Length (MEVL)250 ft.For 3” pipe from Table 1
Is TEVL less than MEVL?YESTherefore, 80 mm pipe may be u sed
Therefore, 60mm pipe may NOT be used;
try 80 mm
9
MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M) (CONTINUED)
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 3 – Maximum Equivalent Vent Length -- Ft. (M)
1. Use only the vent pipe sizes shown for each furnace. It is NOT necessary to choose the smallest diameter pipe possible for venting.
2. NA --- Not al lowed. Pressure switch wil l n ot close, or flame distu rbance may result.
3. Total equivalent vent lengths under 10’ for 40,000 BTUH furnaces from 0 to 2000 ft. (0 to 610 M) above sea level require use of an outlet choke plate .
Failure to use an outlet choke when required may result in flame disturbance or flame sense lockout.
4. Not all furnace families include 140,000 BTUH input models.
5. Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having jurisdiction.
6. Size both the combustion air and vent pipe independently, then use the larger size for both pipes.
7. Assume the two 45_ elbows equal one 90_ elbow. Wide radius elbows are desirable and may be required in some cases.
8. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
9. The minimu m pipe length is 5 ft. (1.5 M) lin ear feet (meters) for all applications.
10. Use 3 --- in. (76 mm) diameter ven t termination kit for installations requiring 4 --- in. (102 mm) diameter pipe.
NANANA16(4.9)20(6.1)
DIRECT VENT (2 -PIPE) AND SINGLE-PIPE
Vent Pipe Diameter (in.)
1
NA
2
NA
10
MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE -- FT. (M)
* Not all families have these models.
* Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total al lowable pipe
length calculated from Table 1 or 3.
† Insulation thickness based on R value of 3.5 per in.
This furnace is designed for continuous return--air minimum temperature of 60_F(15_C) db or intermittent operation down to 55_F(13_C)
db such as when used with a night setback thermometer. Return--air temperature must not exceed 80_F(27_C) db. Failure to follow these
return air limits may affect reliability of heat exchangers, motors and controls.
80/ 27˚C
SUPPLY AIR
60
/ 16˚C
PG96VAT
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
POSITIONCLEARANCE
Rear0(0mm)
Front (Combustion air openings in furnace and in structure)1in.(25mm)
Required for service**24 in. (610 mm)*
All Sides of Supply Plenum**1in.(25mm)
Sides0(0mm)
Ve n t0(0mm)
* Recommended
**Consult your local building codes
Top of Furnace1in. (25mm)
A10490
COMBUSTION--AIR PIPE FOR NON--DIRECT (1--PIPE) VENT APPLICATION
NOTE: See Installation Instructions for specific venting configurations.
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
PVC PIPE
A12376
12
DOWNFLOW SUBBASE
LOCATING
TAB
11/
4-IN. TYP
PLENUM
OPENING
A
LOCATING
TAB
B
4
3
D
2
1
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
C
A97427
Assembled
DIMENSIONS (IN. / MM)
FURNACE
CASING WIDTH
14--- 3/16 (360)
17--- 1/2 (445)
21 (533)
24--- 1/2 (622)
*The plenum should be constructed 1/4 ---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
FURNACE IN DOWNFLOW
APPLICATION
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
PLENUM OPENING*FLOOR OPENING
ABCD
11--- 3/16
(322)
15--- 1/8
(384)
18--- 5/8
(396)
22--- 1/8
(562)
19 (483)
19 (483)
19 (483)
19 (483)
13--- 7/16
(341)
16--- 3/4
(426)
20--- 1/4
(514)
23--- 3/4
(603)
Disassembled
20--- 5/8
(600)
20--- 5/8
(600)
20--- 5/8
(600)
20--- 5/8
(600)
1
2
3
4
A88207
HOLE NO. FOR
WIDTH
ADJUSTMENT
4
3
2
1
PG96VAT
Concentric Vent Kit
A concentric vent kit allows vent and combustion--air pipes to
terminate through a single exit in a roof or side wall. One pipe
runs inside the other allowing venting through the inner pipe and
combustion air to be drawn in through the outer pipe.
A93086
Downflow Subbase
A88202
One base fits all furnace sizes. The base is designed to be installed
between the furnace and a combustible floor when no coil box is
used or when a coil box other than a Payne cased coil is used. It is
CSA design certified for use with PayneR branded furnaces when
installed in downflow applications.
13
TYPICAL WIRING SCHEMATIC
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
NOTE 2
FIVE WIRE
WCRGY
THREE-WIRE
HEATING-ONLY
BLOWER DOOR SWITCH
BLK
WHT
BLK
WHT
W
C
R
O
N
GND
115-V FIELD-
SUPPLIED
GND
AUXILIARY
J-BOX
DISCONNECT
PG96VAT
T
G
R
O
COM
L
Y
24-V
TERMINAL
NOTE 1
BLOCK
FURNACE
NOTES:Connect Y-terminal in furnace as shown for proper blower operation.
1.
Some thermostats require a "C" terminal connection as shown.
2.
If any of the original wire, as supplied, must be replaced, use
3.
same type or equivalent wire.
THERMOSTAT
TERMINALS
CONDENSING
UNIT
TWO
WIRE
FIELD-SUPPLIED
DISCONNECT
GND
208/230- OR
460-V
THREE
PHASE
208/230-V
SINGLE
PHASE
A11387
14
29 1/2
[749.3]
DIMENSIONAL DRAWING
20 5/8
[522.7]
21 1/16
[535.8]
[557.4]
21 15/16
26 3/8
[669.9]
[678.1]
28 3/4
[730.5]
26 11/16
AIR FLOW
3
[76.2]
1 3/4
[44.5]
AIR INTAKE
7/8
GAS CONN
[22.2]
E
REV
1
SHT
23 3/8
7/8
[22.2] POWER CONN
[63.5]
4
35
[101.6]
[889.0]
SIDE INLET
28 3/8
[720.4]
[757]
29 13/16
7/8
[22.2]
24
28 5/8
7/8
[22.2]
THERMOSTAT ENTRY
[420.9]
16 9/16
[442.3]
17 7/16
18 1/16
20 1/4
[513.9]
[609.7]
[726.9]
[458.6]
7/8
[22.2]
2 1/2
3
[76.2 ]
21 5/8
[549.5]
BOTTOM INLET
6 1/16
[154.0]
11/16
[17.5]
[592.0]
1 5/16
[668.8]
26 5/16
[33.3]
SD5024-4
2
PART NUMBER
NEXT SHEET
PG96VAT
B
A
NOTES:
1. Doors may vary by model.
2. Minimum return-air openings at furnace, based on metal duct. If ex duct is used,
see ex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM-16-in. (406 mm) round or 14 1/2 x 12-in. (368 x 305 mm) rectangle.
b. For 1200 CFM-20-in. (508 mm) round or 14 1/2 x 19 1/2-in. (368 x 495 mm) rectangle.
c. For 1600 CFM-22-in. (559 mm) round or 14 1/2 x 22 1/16-in. (368 x 560mm) rectangle.
d. Return air above 1800 CFM at 0.5 in. w.c. ESP on 24.5" casing, requires one of the following
congurations: 2 sides, 1 side and a bottom or bottom only. See Air Delivery table in this
document for specic use to allow for sucient airow to the furnace.
3. Vent and Combustion air pipes through blower compartment must
use accessory “Vent Kit - Through the Cabinet”. See accessory list for
current part number.
D
[58.4]
6 15/16
[176.1]
2 3/10
3
[76.2]
VENT
3
[76.2]
AIR INTAKE
[170.1]
6 11/16
TOP VIEW
[678.1]
26 11/16
26 3/8
[670.0]
25 1/8
[638.7]
23 5/16
[592.9]
20 5/8
[522.7]
19 1/8
OUTLET WIDTH
3
[76.2]
AIR INTAKE
[485.8]
AIR FLOW
5/8
[15.8]
1 3/4
AIR FLOW
[44.5]
3
[76.2]
VENT
GAS CONN
7/8
[22.2]
4
[101.6]
CONDENSATE DRAIN TRAP
LOCATION
2 1/2
7/8
[22.2]
32 5/8
[829.5]
28 5/8
[715.9]
28 3/16
7/8
[22.2] POWER CONN
[63.5]
7/8
[22.2]
[726.4]
25 3/16
[595.6]
23 7/16
20 1/4
[513.9]
16 9/16
7/8
SIDE INLET
[639.1]
[581.9]
22 15/16
[439.2]
17 5/16
[420.9]
[376.3]
14 13/16
[22.2]
THERMOSTAT ENTRY
C
WIDTH
BOTTOM RETURN
NOTE: ALL DIMENSIONS IN INCH [MM]
11/16
[17.5]
SEE NOTE #3
[668.8]
22
26 5/16
21
[534.0]
[558.3] (BOTH SIDES)
[25.4]
1 (BOTH SIDES)
PG96VAT
FURNACE SIZE
ABCD
CABINET WIDTHOUTLET WIDTHBOTTOM IN LET WIDTHAIR INTAKE
Furnish a ______________________ 4--way multipoise gas--fired
condensing furnace for use with natural gas or propane (factory-authorized conversion kit required for propane).
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit
will carry the CSA Blue StarR and Blue FlameR labels. Unit
efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Delivery, Storage, and Handling
PG96VAT
Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
Equipment
Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of ECM type shall be
permanently lubricated with sealed ball bearings, of _______hp,
and have infinitely variable speed from 600--1200 RPM operating
only when motor inputs are provided. Blower motor shall be direct
drive and soft mounted to the blower housing to reduce vibration
transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.
(mm) X ________ in. (mm). An accessory highly efficient Media
Filter is available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted
galvanized steel.
Draft Inducer
Draft inducer motor shall be two--speed PSC design.
Motor
Primary Heat
Primary heat exchangers shall be 3--Pass corrosion-- resistant
aluminized steel of fold--and--crimp sectional design and applied
operating under negative pressure.
Secondary Heat
Secondary heat exchangers shall be of a stainless steel
flow--through of fin--and--tube design and applied operating under
negative pressure.
Controls
Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting
codes displayed via diagnostic flashing LED light on the control, a
self--test feature that checks all major functions of the furnace, and
a replaceable automotive--type circuit protection fuse. Multiple
operational settings available, including separate blower speeds for
low heat, high heat, low cooling, high cooling and continuous fan.
Continuous fan speed may be adjusted from the thermostat.
Cooling airflow will be selectable between 325 to 400 CFM per
ton of air conditioning. Features will also include temporary
reducedairflowinthecoolingmodeforimproved
dehumidification when a dehumidification--capable thermostat is
used.
__________in. (mm); height___________in. (mm) (casing only).
Height shall be _________in. (mm) with A/C coil and
_________________in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be ________AWG; maximum fuse size
of HACR--type designated circuit breaker shall be _________
amps.
Special Features
Refer to section of the product data identifying accessories and
descriptions for specific features and available enhancements.
E2012 Payne Heating & Cooling Systems D7310 W. Morris St. D Indianapolis, IN 46231Edition Date: 09/12
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
C a t a l o g N o : S S --- P G 9 6 V A T --- 0 2
R e p l a c e s : S S --- P G 9 6 V AT --- 0 1
16