Utilizing the extensive resources available to PayneR,anew
standard of excellence has been achieved with the model
PG95XAT. The model is a unique 4--way multipoise condensing
furnace with features like no other product in its class including
two heating stages and a highly efficient ECM Blower Motor. The
PG95XAT builds on the many Payne successes in the furnace
industry and establishes a new standard for all high--efficiency gas
furnaces.
S Heating efficiency of 95.5% AFUE
S Two heating stages
S Highly efficient ECM blower motor
S Humidity control when paired with a compatible condensing
unit and using a humidity sensing thermostat
S Adjustable constant fan speed from a compatible thermostat
S LED diagnostics and self test feature
S Stores fault codes during power outages
S Adjustable heating air temperature rise
S Dehumidification terminals on control board
S Hot surface ignition
S Dual fuel compatible
S Two--speed inducer motor
PG95XAT
STANDARD FEATURES
CERTIFIED
LIMITED WARRANTY*
S 20--year limited warranty on heat exchangers.
S 10 year parts and lifetime heat exchanger limited warranty to the
original purchaser upon timely registration.
A11300
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.{
* For owner occupied, residential applications.
{Jurisdictions where warranty benefits cannot be conditioned on registra-
tion will receive registered limited war ranty benefits.
1
Always Ask For
SPECIFICATIONS
A
Heating Capacity and Efficiency030040042060048080048100066120
Input
Output
EfficiencyAFUE % (ICS)95.595.595.595.595.5
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data030040042060048080048100066120
Certified External Static
Pressure (in. w.c.)
Airflow Delivery
@RatedESP(CFM)
Cooling Capacity (tons)
@ 400, 350 CFM/ton
Direct-Drive Motor TypeElectronically Commutated Motor (ECM)
Direct-Drive Motor HP1/23/43/411
Motor F ull Load Amps6.88.48.410.910.9
RPM Range600 - 1200
Speed Selections5
Blower Wheel Dia x Widthin.11x711x811x811x1011 x 11
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data030040042060048080048100066120
Input VoltageVolts-Hertz-Phase115-60-1
Operating Voltage RangeMin-Max104-127
Maximum Input AmpsAmps8.29.89.812.312.3
Unit AmpacityAmps11.013.013.016.116.1
Minimum Wire SizeAWG1414141212
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)40 VA
External Control Power
vailable
Controls030040042060048080048100066120
Gas Connection Size1/2” - NPT
Burners (Monoport)23456
Gas Valve (Redundant)
Gas Conversion Kit - Natural to PropaneKGANP51012SP
Gas Conversion Kit - Propane to NaturalKGAPN43012SP
Manufactured (Mobile) Home Kitnot approved for MH use
Ignition DeviceSilicon Nitride
Limit Control165180170160160
Heating Blower Control (Heating Off-Delay)Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay)90 seconds
Communication Systemnone
Thermostat ConnectionsW2,Y1,DHUM,GCW/W1,Y/Y2,R
Accessory ConnectionsEAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
High Heat(BTUH)40,00060,00080,000100,000120,000
Low Heat(BTUH)26,00039,00052,00065,00078,000
High Heat(BTUH)39,00058,00078,00098,000117,000
Low Heat(BTUH)25,00038,00052,00063,00076,000
X = Used with this model furnace
N/A = Not used with this model furnace
4
AIR DELIVERY -- CFM (BOTTOM RETURN WITH FILTER)
INPUT
BTUH
40000SIDE/BOTTOM
60000SIDE/BOTTOM
80000SIDE/BOTTOM
100000SIDE/BOTTOM
120000
NOTE: A filter is required for each return ---air inlet. Airflow performance included 3/4 - -- in. (19 mm) washable filter media su ch as contained in factory --- a u t h o r i z e d
RETURN-AIR
SUPPLY
BOTTOM OR
TWO SIDES
accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 in. W.C. available external static pressure.
--- Indicates unstable operating conditions.
SPEED
5(Gry)112010801030980925875820760690630
4(Yel)880845810780740710680640615570
3(Blu)695665620575535495455420370280
2(Org)640595540495460420370310260230
1(Red)570525475425385330255220--
5(Gry)1720167016201565150514401375129512201135
4(Yel)1325128512551220118511451115107510401000
3(Blu)1010970925875835785745690660620
2(Org)11601115108010451000960920875840785
1(Red)785715655595530490435385340285
5(Gry)1810177017201665161015401475140013151235
4(Yel)1535150014751435140513701340131012451160
3(Blu)1380134013051270124012001165113010901050
2(Org)11801130109510601015975935895850800
1(Red)110010451010970920885845790745690
5(Gry)2040197018851795172016351540145013601230
4(Yel)1550150514601415136513251280123011801135
3(Blu)1780173016901645161015551481140013101210
2(Org)13451295125011951155110510551000955915
1(Red)139013501295126012001160110510501010965
5(Gry)2275223021852130205519501825171016101500
4(Yel)1875182017701720166016001550150514501390
3(Blu)2170212520752025197519001790169515901470
2(Org)14751420135012801215116511051050995930
1(Red)1625156515051445138513251275122511701130
0.10.20.30.40.50.60.70.80.91
EXTERNAL STA TIC PRESSURE (IN. W.C.)
5
MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M)
NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from
Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 1 – Maximum Equivalent Vent Length -- Ft. (M)
0 to 4500 Ft. (0 to 1370 M) Altitude
Altitude
FT (M)
0 to 2000
(0 to 610)
2001 to 3000
(610 to 914)
3001 to 4000
(914 to 1219)
4001 to 4500
(1219 to
1370)
* Not all families have these models.
NOTE: See notes at end of venting tables.
NOTE: See Table 3 for altitudes over 4500 ft. (1370 M)
Unit Size
BTU/Hr
2
40,000*
60,00030(9.1)135(41.1)235(71.6)265(80.8)NA
80,00020(6.1)70(21.3)175(53.3)235(71.6)265(80.8)
100,000NA25(7.6)110(33.5)235(71.6)265(80.8)
120,000NANA15(4.6)100(30.5)250(76.2)
40,000*45(13.7)198(60.4)232(70.7)NANA
60,00027(8.2)127(38.7)222(67.7)250(76.2)NA
80,00017(5.2)64(19.5)165(50.3)222(67.7)249(75.9)
100,000NA22(6.7)104(31.7)223(68.0)250(76.2)
120,000NANA11(3.4)93(28.3)237(72.2)
40,000*39(11.9)184(56.1)214(65.2)NANA
60,00023(7.0)119(36.3)210(64.0)235(71.6)NA
80,00015(4.6)59(18.0)155(47.2)210(64.0)232(70.7)
100,000NA19(5.8)98(29.9)211(64.3)236(71.9)
120,000NANA8(2.4)86(26.2)224(68.3)
40,000*36(11.0)177(53.9)205(62.5)NANA
60,00021(6.4)115(35.1)204(62.2)228(69.5)NA
80,00014(4.3)56(17.1)150(45.7)202(61.6)224(68.3)
100,000NA17(5.2)94(28.7)205(62.5)229(69.8)
120,000NANANA83(25.3)217(66.1)
1-1/222-1/234
50(15.2)210(64.0)250(76.2)NANA
DIRECT VENT (2 -PIPE) AND NON ---DIRECT VENT (1---PIPE)
Vent Pipe Diameter (in.)
Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M)
Pipe Diameter (in):1-1/222-1/23*4*
Mitered 90º Elbow8(2.4)8(2.4)8(2.4)NANANANA
Medium Radius 90º Elbow5(1.5)5(1.5)5(1.5)NANANANA
Long Radius 90º Elbow3(0.9)3(0.9)3(0.9)3(0.9)3(0.9)
Mitered 45º Elbow4(1.2)4(1.2)4(1.2)NANANANA
Medium Radius 45º Elbow2.5(0.8)2.5(0.8)2.5(0.8)NANANANA
Long Radius 45º Elbow1.5(0.5)1.5(0.5)1.5(0.5)1.5(0.5)1.5(0.5)
Tee16(4.9)16(4.9)16(4.9)16(4.9)16(4.9)
*Note: 3 --- and 4 ---in. Vent pipe systems require long radius elbows.
Venting System Length Calculations
The maximum length for each vent pipe (inlet or exhaust) equals the Maximum Equivalent Vent Length (MEVL) from Table 1 or Table 3
minus the number of elbows multiplied by the deduction for each elbow in Table 2.
Standard vent terminations and concentric vent terminations count for zero deductions.
Example
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M ) with 2--in. (51 mm) vent piping. Venting system includes, FOR EACH
PIPE, (3) 90_ long radius elbows, (2) 45_ long radius elbows and a concentric vent kit.
Maximum Equivalent Vent Length=127 ft.(From Table 1)
Deduct (3) 90 long radius3x3 ft.=- 9 ft.(From Table 2)
Deduct (2) 45 long radius2x1.5 ft.=- 3 ft.(From Table 2)
Maximum Vent Length=115 ft.For EACH vent or inlet pipe
6
MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M)
Table 3 – Maximum Equivalent Vent Length -- Ft. (M)
4501 to 10,000 Ft. (0 to 1370 M) Altitude
NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from
Maximum Equivalent Vent Length to determine allowable vent length for each application.
Altitude
FT (M)
Unit Size
1-1/222-1/234
40,000*33(10.1)171(52.1)196(59.7)NANA
4501 to 5000
(1370 to
1524)
60,00020(6.1)111(33.8)198(60.4)221(67.4)NA
80,00013(4.0)54(16.5)146(44.5)195(59.4)216(65.8)
100,000NA16(4.9)91(27.7)200(61.0)222(67.7)
120,000NANANA80(24.4)211(64.3)
40,000*27(8.2)158(48.2)179(54.6)NANA
5001 to 6000
(1524 to
1829)
60,00016(4.9)103(31.4)186(56.7)207(63.1)NA
80,00011(3.4)49(14.9)137(41.8)183(55.8)200(61.0)
100,000NA12(3.7)85(25.9)188(57.3)208(63.4)
120,000NANANA74(22.6)199(60.7)
40,000*21(6.4)145(44.2)162(49.4)NANA
6001 to 7000
(1829 to
2134)
60,00013(4.0)96(29.3)174(53.0)194(59.1)NA
80,000NA44(13.4)120(36.6)171(52.1)185(56.4)
100,000NA10(3.0)79(24.1)178(54.3)195(59.4)
120,000NANANA68(20.7)187(57.0)
40,000*15(4.6)133(40.5)146(44.5)NANA
7001 to 8000
(2134 to
2438)
60,00010(3.0)89(27.1)163(49.7)181(55.2)NA
80,000NA40(12.2)120(36.6)159(48.5)170(51.8)
100,000NANA73(22.3)167(50.9)182(55.5)
120,000NANANA62(18.9)175(53.3)
40,000*10(3.0)121(36.9)130(39.6)NANA
8001 to 9000
(2438 to
2743)
60,0007(2.1)82(25.0)152(46.3)168(51.2)NA
80,000NA35(10.7)111(33.8)148(45.1)156(47.5)
100,000NANA67(20.4)157(47.9)170(51.8)
120,000NANANA56(17.1)164(50.0)
40,000*5(1.5)110(33.5)115(35.1)NANA
9001 to
10,000
(2743 to
3048)
60,000NA76(23.2)142(43.3)156(47.5)NA
80,000NA31(9.4)103(31.4)137(41.8)142(43.3)
100,000NANA62(18.9)147(44.8)157(47.9)
120,000NANANA51(15.5)153(46.6)
*Not all families have these models.
Notes:
1. 3 --- and 4---in. Vent pipe systems require long radius elbows.
2. Total equivalent vent lengths under 10’ for 40,000 require the use of an ou tl et choke plate at altitude 0 to 2,000 ft ( 0 to 610M).
Failure to use an outlet choke when required may result in flame disturbance or flame sense lockout.
3. Vent sizing for Canadian installations over 4500 ft (1370m) above sea level are subject to acceptance by the local authorities having jurisdiction.
4. NA --- Not allowed; pressure switch will not close, or flame disturbance may result.
5. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur.
6. Size both the combustion - -- air and vent pipe independently, then use the larger diameter for both pipes.
7. Assume the two 45_ elbows equal one 90_ elbow. Wide radius elbows are desirable and may be required in some cases.
8. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
9. The minimum pipe length is 5 ft. (1.5 M) for all applications.
10. Use 3 ---in. (76 mm) diameter vent termination kit for installations requiring 4 ---in. (102 mm) diameter pipe.
DIRECT VENT (2 -PIPE) AND NON ---DIRECT VENT (1 --- PIPE)
Vent Pipe Diameter
7
MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE -- FT. (M)
Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M)
This furnace is designed for continuous return--air minimum temperature of 60_F(15_C) db or intermittent operation down to 55_F(13_C)
db such as when used with a night setback thermometer. Return--air temperature must not exceed 80_F(27_C) db. Failure to follow these
return air limits may affect reliability of heat exchangers, motors and controls.
80/ 27˚C
SUPPLY AIR
60
/ 16˚C
A10490
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
POSITIONCLEARANCE
Rear0(0mm)
Front (Combustion air openings in furnace and in structure)1in.(25mm)
Required for service*24 in. (610 mm)
All Sides of Supply Plenum1in.(25mm)
Sides0(0mm)
Ve n t0(0mm)
* Recommended
Top of Furnace1in. (25mm)
COMBUSTION--AIR PIPE FOR NON--DIRECT (1--PIPE) VENT APPLICATION
*The plenum should be constructed 1/4 ---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
FURNACE IN DOWNFLOW
APPLICATION
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
PLENUM OPENING*FLOOR OPENING
ABCD
15--- 1/8
(384.2)
18--- 5/8
(396.4)
22--- 1/8
(562.0)
19 (482.6)
19 (482.6)
19 (482.6)
16--- 3/4
(425.5)
20--- 1/4
(514.4)
23--- 3/4
(603.3)
20--- 3/8
(517.5)
20--- 3/8
(517.5)
20--- 3/8
(517.5)
1
2
3
4
A88207
HOLE NO. FOR
WIDTH
ADJUSTMENT
3
2
1
Concentric Vent Kit
A concentric vent kit allows vent and combustion--air pipes to
terminate through a single exit in a roof or side wall. One pipe
runs inside the other allowing venting through the inner pipe and
combustion air to be drawn in through the outer pipe.
A93086
Downflow Subbase
A88202
One base fits all furnace sizes. The base is designed to be installed
between the furnace and a combustible floor when no coil box is
used or when a coil box other than a Payne cased coil is used. It is
CSA design certified for use with Payne branded furnaces when
installed in downflow applications.
10
BLOWER
DOOR
SWITCH
BLK
WHT
GND
115-VOLT FIELD-
SUPPLIED
FUSED
DISCONNECT
BLK
WHT
JUNCTION
BOX
FIVE
WIRE
THREE-WIRE
HEATING-
ONLY
FURNACE
TYPICAL WIRING SCHEMATIC
W2
C
COM
O
N
W/W1
T
Y/Y2
R
O
R
L
G
24-VOLT
TERMINAL
BLOCK
NOTE 2
WCYRG
NOTE 1
NOTES: 1.
Connect Y/Y2-terminal as shown for proper operation.
Some thermostats require a "C" terminal connection as shown.
2.
If any of the original wire, as supplied, must be replaced, use
3.
same type or equivalent wire.
1-STAGE
THERMOSTAT
TERMINALS
CONDENSING
UNIT
FIELD 24-VOLT WIRING
FIELD 115-, 208/230-, 460-VOLT WIRING
FACTORY 24-VOLT WIRING
FACTORY 115-VOLT WIRING
FIELD-SUPPLIED
FUSED DISCONNECT
208/230- OR
460-VOLT
THREE
PHASE
208/230VOLT
SINGLE
GND
PHASE
A11401
11
DIMENSIONAL DRAWING
NOTE: Doors may vary by model.
a. For 800 CFM ---16 ---in. (406 mm) round or 14 1/2 x 12--- i n. (368 x 305 mm) rectangle.
b. For 1200 CFM ---20 --- in. (508 mm) round or 14 1/2 x 19 1/2 ---in. (368 x 495 mm) rectangle.
c. For 1600 CFM ---22--- in. (559 mm) round or 14 1/2 x 22 1/16 ---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Installation Instructions literature for specific use of single side inlets. The use o f bot h side inlets, a combina -
tion of 1 side and the bottom, or the bottom only return air openings may be required for airflow requirements above 1800 CFM at 0.5 in. w.c. E.S.P.
A11445
12
GUIDE SPECIFICATIONS
General
System Description
Furnish a ______________________ 4--way multipoise gas--fired
condensing furnace for use with natural gas or propane (factory-authorized conversion kit required for propane); furnish cold air
return plenum; furnish external media cabinet for use with
accessory media filter or standard filter.
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit
will carry the CSA Blue StarR and Blue FlameRlabels. Unit
efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
Equipment
Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of ECM type shall be
permanently lubricated with sealed ball bearings, of _______hp,
and have multiple speeds from 600--1200 RPM operating only
when 24--VAC motor inputs are provided. Blower motor shall be
direct drive and soft mounted to the blower scroll to reduce
vibration transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.
(mm) X ________ in. (mm). An accessory highly efficient Media
Filter is available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted
galvanized steel.
Draft Inducer
Draft inducer motor shall be two--speed design.
Motor
Primary Heat
Primary heat exchangers shall be 3--Passcorrosion--resistant
aluminized steel of fold--and--crimp sectional design and applied
operating under negative pressure.
Secondary Heat
Secondary heat exchangers shall be of a stainless steel
flow--through of fin--and--tube design and applied operating under
negative pressure.
Controls
Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting
codes displayed via diagnostic flashing LED light on the control, a
self--test feature that checks all major functions of the furnace, and
a replaceable automotive--type circuit protection fuse. Multiple
operational settings available, including blower speeds for low
heat, high heat, low cooling, high cooling and continuous fan.
Continuous fan speed may be adjusted from the thermostat.
Cooling airflow will be selectable between 325 and 400 CFM per
ton of air conditioning.
__________in. (mm); height___________in. (mm) (casing only).
Height shall be _________in. (mm) with A/C coil and
_________________in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be ________AWG; maximum fuse size
of HACR--type designated circuit breaker shall be _________
amps.
Special Features
Refer to section of the product data identifying accessories and
descriptions for specific features and available enhancements.
13
E2011 Payne Heating & Cooling Systems D7310 W. Morris St. D Indianapolis, IN 46231Printed in U.S.A.Edition Date: 09/11
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
14
C a t a l o g N o : S S --- P G 9 5 X A T --- 0 1
Replaces: New