The model PG92SCS is an efficient and robust 4--way multipoise
condensing furnace with features including single--stage heating
and a rugged PSC Blower Motor. The PG92SCS builds on the
many Payne successes in the furnace industry and establishes a
new standard for all high--efficiency gas furnaces.
S Heating efficiency of 92.1% AFUE.
S Direct--vent/sealed combustion, single--pipe venting or
ventilated combustion air.
S PSC blower motor.
S 4--way multipoise furnace.
S Hot surface ignition.
S LED diagnostics and self test feature.
S Stores fault codes during power outages.
S Adjustable heating air temperature rise.
S Adjustable cooling airflow.
S Approved for Manufactured Housing/Mobile Home applications
with MH accessory kit.
S Approved for Twinning applications (48060 through 60120
sizes, only).
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1-inch water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
PG92SCS ALL
PG92SBS 048080 ONLY
SERIES A
STANDARD FEATURES
A11300
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
† Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.
‡ Heating CFM at factory default blower motor heating tap settings.
ESP --- External Static Pressure
DIMENSIONS (IN.)
HDW(BTUH)AFUECFM‡
RATED HEATING
OUTPUT†
HEATING AIRFLOW
Heating ESP
(in. W.C.)
COOLING CFM @ 0.5
ESP
(in. W.C.)
FEATURES AND BENEFITS
PG92SCS
HYBRID HEATR Dual Fuel system compatible — This system
can provide more control over your monthly energy bills by
automatically selecting the most economical method of heating.
With HYBRID HEAT components, our system automatically
switches between the gas furnace and the electric heat pump as
outside temperatures change to maintain greater efficiency and
comfort than with any traditional single-source heating system.
The heat pump also delivers high-efficiency cooling in the summer.
Robust Igniter — Payne’s unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further enhances
the gas furnace reliability and continues Payne’s tradition of
technology leadership and innovation in providing a reliable and
durable product.
Reliable Heat Exchanger Design — The aluminized steel, clam
shell primary heat exchanger was re--engineered to achieve greater
efficiency out of a smaller size. The first two passes of the heat
exchanger are based on the current 80% product, a design with
more than ten years of field-proven performance and success.
These innovations, paired with the continuation of a crimped,
no-weld seam create an efficient, robust design for this essential
component.
The condensing heat exchanger, a stainless steel fin and tube
design, is positioned in the furnace to extract additional heat.
Stainless steel coupling box componentry between heat exchangers
has exceptional corrosion resistance in both natural gas and
propane applications.
4-Way Multipoise Design — One model for all applications –
there is no need to stock special downflow or horizontal models
when one unit will do it all. The new heat exchanger design allows
these units to achieve the certified AFUE in all positions.
Direct or Single-pipe Venting, or Optional Ventilated
Combustion Air — This furnace can be installed as a 2-pipe
(Direct Vent) furnace, in an optional ventilated combustion air
application, or in single-pipe, non-direct vent applications. This
provides added flexibility to meet diverse installation needs.
Sealed Combustion System — This furnace brings in combustion
air from outside the furnace, which results in especially quiet
operation. By sealing the entire combustion vestibule, the entire
furnace can be made quieter, not just the burners.
Monoport Burners — The burners are specially designed and
finely tuned for smooth, quiet combustion and economical
operation.
Bottom Closure — Factory--installed for side return; easily
removable for bottom return. The multi-use bottom closure can
also serve for roll-out protection in horizontal applications, and act
as the bottom closure for the optional return air base accessory.
Blower Access Panel Switch — Automatically shuts off 115-v
power to furnace whenever blower access panel is opened.
Quality Registration — Our furnaces are engineered and
manufactured under an ISO 9001 registered quality system.
Certifications — This furnace is CSA (AGA and CGA) design
certified for use with natural and propane gases. The furnace is
factory--shipped for use with natural gas. A CSA listed gas
conversion kit is required to convert furnace for use with propane
gas. The efficiency is AHRI efficiency rating certified. This furnace
meets California Air Quality Management District emission
requirements.
MOTOR HP -
SPEED TAPS
2
Page 3
SPECIFICATIONS
The furnace should be sized to provide 100 percent of the design
heating load requirement plus any margin that occurs because of
furnace model size capacity increments. None of the furnace
model sizes can be used if the heating load is 20,000 BTU or
lower. Use Air Conditioning Contractors of America (Manual J
and S); American Society of Heating, Refrigerating, and
Air-Conditioning Engineers; or other approved engineering
Heating Capacity and Efficiency30040480604808060080481006010060120
Input
Output
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data30040480604808060080481006010060120
Rated External Static
Pressure (in. W.C.)
Airflow Delivery
@ Rated ESP (CFM)
Cooling Capacity (tons)
Direct-Drive Motor TypePermanent Split Capacitor (PSC)
Direct-Drive Motor HP0.3.50.50.750.511
Motor Full Load Amps4.67.97.47.96.511.111.1
RPM Range500 - 1150
Speed Selections4455444
Blower Wheel Dia x Widthin.11 x 711 x 811 x 811 x 1011 x 1011 x 1011 x 11
Air Filtration SystemField Supplied
Filter Used for Certified Watt Data*KGAWF**06UFR
method to calculate heating load estimates and select the furnace.
Excessive oversizing of the furnace may cause the furnace and/or
vent to fail prematurely, customer discomfort and/or vent freezing.
Failure to follow these guidelines is considered faulty installation
and/or misapplication of the furnace; and resulting failure, damage,
or repairs may impact warranty coverage.
Input VoltageVolts-Hertz-Phase115-60-1
Operating Voltage RangeMin-Max104-127
Maximum Input AmpsAmps5.28.68.18.67.311.911.9
Unit AmpacityAmps7.511.711.111.710.115.815.8
Minimum Wire SizeAWG14141414141212
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)40 VA
External Control Power Available
Controls30040480604808060080481006010060120
Gas Connection Size1/2" - NPT
Burners (Monoport)2344556
Gas Valve (Redundant)ManufacturerWhite Rodgers
Minimum Inlet Gas pressure (in. W.C.)4.5
Maximum Inlet Gas pressure (in. W.C.)13.6
Ignition DeviceSilicon Nitride
Limit Control195190185195220220165
Heating Blower Control (Heating Off-Delay)Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay)90 seconds
Communication Systemnone
Thermostat ConnectionsCom24V,R,W,G,Y
Accessory ConnectionsEAC (115vac); HUM (24vac)
Freeze Protect Kit - Trap HeaterKGAHT0201CFPDDDDDDD
CPVC to PVC Drain Adapters - 1/2” CPVC to 3/4” PVCKGAAD0110PVCDDDDDDD
Horizontal Trap Grommet - Direct VentKGACK0101HCKAll DV Horizontal
Condensate Neutralizer KitP908--- 0001DDDDDDD
External Trap KitKGAET0201ETKDDDDDDD
Ductwork Adapter Accessories
Furnace Base Kit for Combustible FloorsKGASB0201ALLDDDDDDD
Coil Adapter Kits --- No OffsetKGADA0101ALLDDDDDDD
Coil Adapter Kits --- Single OffsetKGADA0201ALLDDDDDDD
Coil Adapter Kits --- Double OffsetKGADA0301ALLDDDDDDD
Return Air Base (U pflow Applications) 14.0 --- in. wideKGARP0301B14D
Return Air Base (U pflow Applications) 17.5 --- in. wideKGARP0301B17DD
Return Air Base (U pflow Applications) 21.0 --- in. wideKGARP0301B21DDD
Return Air Base (U pflow Applications) 24.5 --- in. wideKGARP0301B24D
IAQ Device Duct Adapters 20.0 --- in. IAQ to 16 in. Side
Return
IAQ Device Duct Adapters 24.0 --- in. IAQ to 16 in. Side
Return
Gas Conversion Accessories
Mobile Home KitKGBMH0601KITDDDDDDD
Gas Conversion Kit - Nat to LPKGBNP50011SPDDDDDDD
Gas Conversion Kit - L P to NatKGBPN42011SPDDDDDDD
GasOrificeKit-#42(NatGas)LH32DB207DDDDDDD
GasOrificeKit-#43(NatGas)LH32DB202DDDDDDD
GasOrificeKit-#44(NatGas)LH32DB200DDDDDDD
GasOrificeKit-#45(NatGas)LH32DB205DDDDDDD
GasOrificeKit-#46(NatGas)LH32DB208DDDDDDD
GasOrificeKit-#47(NatGas)LH32DB078DDDDDDD
GasOrificeKit-#48(NatGas)LH32DB076DDDDDDD
Gas Orifice Kit - #54 (LP)LH32DB203DDDDDDD
Gas Orifice Kit - #55 (LP)LH32DB201DDDDDDD
Gas Orifice Kit - #56 (LP)LH32DB206DDDDDDD
Gas Orifice Kit - 1.25mm (LP)LH32DB209DDDDDDD
Gas Orifice Kit - 1.30mm (LP)LH32DB210DDDDDDD
Control Accessories
Twinning KitKGATW0701HSIDDDDDD
IAQ Accessories
Filter Rack --- Side Return for 1” FiltersKGAFR0201ALLDDDDDDD
Filter Rack --- Bottom Return for 1” Filters --- 14.2” wideKGBFR0401B14D
Filter Rack --- Bottom Return for 1” Filters --- 17.5” wideKGBFR0501B17DD
Filter Rack --- Bottom Return for 1” Filters --- 21.0” wideKGBFR0601B21DDD
Filter Rack --- Bottom Return for 1” Filters --- 24.5” wideKGBFR0701B24D
Filter Pack (6 pack) --- Washable - 16x25x1KGAWF1306UFRDDDDDDD
Filter Pack (6 pack) --- Washable - 24x25x1KGAWF1506UFRDDDDDDD
EZ-Flex Filter - 16” (406 mm)EXPXXFIL0016Use with EZXCAB---1016
EZ-Flex Filter - 20” (508 mm)EXPXXFIL0020Use with EZXCAB---1020
EZ-Flex Filter - 24” (610 mm)EXPXXFIL0024Use with EZXCAB---1024
EZ-Flex Filter with End Ca ps - 16” (406 mm)EXPXXUNV0016Use with EZXCAB --- 1016
EZ-Flex Filter with End Ca ps - 20” (508 mm)EXPXXUNV0020Use with EZXCAB --- 1020
EZ-Flex Filter with End Ca ps - 24” (610 mm)EXPXXUNV0024Use with EZXCAB --- 1024
Cartridge Media Filter - 16” ( 406 mm)FILXXCAR0016Use with FILCABXL ---1016
Cartridge Media Filter - 20” ( 508 mm)FILXXCAR0020Use with FILCABXL ---1020
Cartridge Media Filter - 24” ( 610 mm)FILXXCAR0024Use with FILCABXL ---1024
D = Used with the model furnace
DESCRIPTIONPAR T NU MBE R30040480604808060080481006010060120
Test Airflow Delivery @ Various External Static Pressures
0.10.20.30.40.50.60.70.80.91
NOTE:
1. A filter is required for each return --- air inlet. Airflow performance includes a 3/4 --- in. (19 mm) washable filter media such as contained in a factory---author ized accessory filter rack. See accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. W.C.. available external static
pressure.
2. ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH INSTALLATION.
3. Shaded areas indicate that this airflow range is BELOW THE RANGE ALLOWED FOR HEATING OPERATION.
4. Airflows over 1800 CFM require bottom return, two ---side return, or bottom and side return. A minimum filter size of 20” x 25” (508 x 635 mm) is required.
5. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
6. All airflows that are shown in BOLD exceed 0.58 watts per CFM at the given external static pressure.
6
Page 7
Winter
Design
Temp
°F
MAXIMUM ALLOWABLE EXPOSED VENT LENGHT INSULATION TABLE
Table 1 – Maximum Allowable Exposed Vent Length in Unconditioned Space -- Ft.
Unit Size40,000* BTUH60,000 BTUH
Pipe Dia.
in.
20202020205045206050203030252075656020857565
01055202520203025151510102040302520454030
-2052015102020151052025201520302520
-401510515151052015151020201510
Uninsulated
1½22½ 1½22½ 1½22½1½22½31½22½31½22½3
3/8-in. Insulation1/2-in. Insulation
Uninsulated3/8-in. Insulation1/2-in. Insulation
Winter
Design
Temp
°F
Winter
Design
Temp
°F
Winter
Design
Temp
°F
Unit Size80,000 BTUH
Pipe Dia.
in.
20154040353015509075651550707070
015201510515504535301550504035
-201510515353020151540302515
-401051525201551530252010
Unit Size100,000 BTUH
Pipe Dia.
in.
202050403520809580208010590
0202015102055453520655545
-20151052035302020453525
-401052025201020302515
Unit Size120,000 BTUH140,000 BTUH
Pipe Dia.
in.
20105040107595107510555550565105565125
0102015105545106550525155655056560
-20101010352510453051055453055040
-40105102515103020555302053525
1½22½341½22½341½22½34
22½3422½3422½34
Uninsulated
2½342½342½342½342½342½34
Uninsulated3/8-in. Insulation1/2-in. Insulation
Uninsulated3/8-in. Insulation1/2-in. Insulation
3/8-in. Insulation1/2-in. Insulation
Uninsulated3/8-in. Insulation1/2-in. Insulation
Maximum Allowable Exposed Vent Length in Unconditioned Space -- Meters
Standard 2-in., 3-in., or
optional 4-in. termination.
A13110
Table 3 – Deductions from Maximum Equivalent Vent Length -- Ft. (M)
Pipe Diameter (in):1-1/222-1/234
Mitered 90º Elbow8(2.4)8(2.4)8(2.4)8(2.4)8(2.4)
Medium Radius 90º Elbow5(1.5)5(1.5)5(1.5)5(1.5)5(1.5)
Long Radius 90º Elbow3(0.9)3(0.9)3(0.9)3(0.9)3(0.9)
Mitered 45º Elbow4(1.2)4(1.2)4(1.2)4(1.2)4(1.2)
Medium Radius 45º Elbow2.5(0.8)2.5(0.8)2.5(0.8)2.5(0.8)2.5(0.8)
Long Radius 45º Elbow1.5(0.5)1.5(0.5)1.5(0.5)1.5(0.5)1.5(0.5)
Tee16(4.9)16(4.9)16(4.9)16(4.9)16(4.9)
8
Page 9
Venting System Length Calculations
The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent
length of elbows used in the venting system from Table 3.
Standard vent terminations or factory accessory concentric vent terminations count for zero deduction.
See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that one
foot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe.
Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Table 2.
Example 1
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M). Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, (2) 45_ long radius elbows and a factory accessory concentric vent
kit.
Can this application use 2--in. (50 mm ND) PVC/ABS DWV vent piping?
Measure the required linear length of air inlet and vent pipe; insert the
longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the
vent or inlet pipe)
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the
vent or inlet pipe)
Add equiv length of vent termination0ft.From Table 3
Add correction for flexible vent pipe, if any0ft.
Total Equivalent Vent Length (TEVL)112 ft.Add all of the above lines
Maximum Equivalent Vent Length (MEVL)127 ft.For 2” pip e from Table 2
Is TEVL less than MEVL?YESTherefore, 2” pipe may be used
3x3ft=9ft.From Table 3
2x1.5 ft=3ft.From Table 3
100 ft
Use length of the longer of the vent
or air inlet piping system
From Vent Manufacturer’s instructions;
zero for PVC/ABS DWV
Example 2
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M) Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, and a polypropylene concentric vent kit. Also includes 20 feet (6 M)
of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe.
Assume that one meter of flexible 60 mm or 80 mm polypropylene pipe equals 2 Meters of PVC/ABS pipe. VERIFY FROM VENT
MANUFACTURER’S INSTRUCTIONS.
Can this application use 60 mm (O.D.) polypropylene vent piping? If not what size piping can be used?
Measure the required linear length of air inlet and vent pipe; insert the
longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the
vent or inlet pipe)
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the
vent or inlet pipe)
Add equiv length of vent termination9M x3ft/M =18 ft.From Vent Manufacturer’s instructions
Add correction for flexible vent pipe, if any1.8x20 ft=36 ft.From Vent Manufacturer’s instructions
Total Equivalent Vent Length (TEVL)163 ft.Add all of the above lines
3x3ft=9ft.From Vent Manufacturer’s instructions
0x=0ft.From Vent Manufacturer’s instructions
100 ft
Use length of the longer of the vent
or air inlet piping system
PG92SCS
Maximum Equivalent Vent Length (MEVL)127 ft.For 2” pip e from Table 2
Is TEVL less than MEVL?NO
Maximum Equivalent Vent Length (MEVL)250 ft.For 3” pip e from Table 2
Is TEVL less than MEVL?YESTherefore, 80 mm pipe may be used
NOTES:
1. Use only the smallest diameter pipe possible for venting. Over --- sizing may cause flame distu rbance or excessive vent terminal icing or freeze --- up.
2. NA --- Not all owed. Pressure switch will not close, or flame disturbance may result.
3. Total equivalent vent lengths under 10’ for 40,000 BTUH furnaces from 0 to 2000 ft. (0 to 610 M) above sea level require use of an outlet choke plate .
Failure to use an outlet choke when required may result in flame disturbance or flame sense lockout.
4. Not all fu rnace families include 140,000 BTUH input models.
5. Vent sizing for Canadian installa tions over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having j urisdiction.
6. Size both the combustion air and vent pipe independently, then use the larger size for both pipes.
7. Assume the two 45_ elbows equal one 90_ elbow. Wide radius elbows are desirable and may be required in some cases.
8. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
9. The minimum pipe length is 5 ft. (2 M) linear feet (meters) for all application s.
10. Use 3 --- in. (76 mm) diameter ven t termin ation kit for installations requiring 4- --in. (102 mm) diameter pipe.
Therefore, 60mm pipe may NOT be used;
try 80 mm
9
Page 10
RETURN AIR TEMPERATURE
This furnace is designed for continuous return--air minimum temperature of 60_F(15_C) db or intermittent operation down to 55_F(13_C)
db such as when used with a night setback thermometer. Return--air temperature must not exceed 80_F(27_C) db. Failure to follow these
return air limits may affect reliability of heat exchangers, motors and controls.
80/ 27˚C
SUPPLY AIR
60
/ 16˚C
PG92SCS
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
POSITIONCLEARANCE
Rear0(0mm)
Front (Combustion air openings in furnace and in structure)1in.(25mm)
Required for service**24 in. (610 mm)*
All Sides of Supply Plenum**1in.(25mm)
Sides0(0mm)
Ve n t0(0mm)
* Recommended
**Consult your local building codes
Top of Furnace1in. (25mm)
A10490
COMBUSTION--AIR PIPE FOR NON--DIRECT (1--PIPE) VENT APPLICATION
NOTE: Not all models may be available in all casing sizes shown in the table above.
11
Page 12
DOWNFLOW SUBBASE
LOCATING
TAB
11/
4-IN. TYP
PLENUM
OPENING
A
LOCATING
TAB
B
4
3
D
2
1
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
C
A97427
Assembled
DIMENSIONS (IN. / MM)
PG92SCS
FURNACE
CASING WIDTH
14---3/16 (360)
17---1/2 (445)
21 (533)
24---1/2 (622)
*The plenum should be constructed 1/4---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
FURNACE IN DOWNFLOW
APPLICATION
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
PLENUM OPENING*FLOOR OPENING
ABCD
11---3/16
(322)
15---1/8
(384)
18---5/8
(396)
22---1/8
(562)
19 (483)
19 (483)
19 (483)
19 (483)
13---7/16
(341)
16---3/4
(426)
20---1/4
(514)
23---3/4
(603)
Disassembled
20---5/8
(600)
20---5/8
(600)
20---5/8
(600)
20---5/8
(600)
1
2
3
4
A88207
HOLE NO. FOR
WIDTH
ADJUSTMENT
4
3
2
1
Concentric Vent Kit
A concentric vent kit allows vent and combustion--air pipes to
terminate through a single exit in a roof or side wall. One pipe
runs inside the other allowing venting through the inner pipe and
combustion air to be drawn in through the outer pipe.
A93086
Downflow Subbase
A88202
One base fits all furnace sizes. The base is designed to be installed
between the furnace and a combustible floor when no coil box is
used or when a coil box other than a Payne cased coil is used. It is
CSA design certified for use with Payne branded furnaces when
installed in downflow applications.
12
Page 13
BLOWER
DOOR
SWITCH
BLK
WHT
GND
115-VOLT FIELD-
SUPPLIED
FUSED
DISCONNECT
BLK
WHT
JUNCTION
BOX
FIVE
WIRE
THREE-WIRE
HEATING-
ONLY
FURNACE
TYPICAL WIRING SCHEMATIC
W2
C
COM
O
N
W/W1
T
Y/Y2
R
O
R
L
G
24-VOLT
TERMINAL
BLOCK
NOTE 2
WCYRG
NOTE 1
NOTES: 1.
Connect Y/Y2-terminal as shown for proper operation.
Some thermostats require a "C" terminal connection as shown.
2.
If any of the original wire, as supplied, must be replaced, use
3.
same type or equivalent wire.
1-STAGE
THERMOSTAT
TERMINALS
CONDENSING
UNIT
FIELD 24-VOLT WIRING
FIELD 115-, 208/230-, 460-VOLT WIRING
FACTORY 24-VOLT WIRING
FACTORY 115-VOLT WIRING
FIELD-SUPPLIED
FUSED DISCONNECT
208/230- OR
460-VOLT
THREE
PHASE
208/230VOLT
SINGLE
GND
PHASE
PG92SCS
A11401
13
Page 14
DIMENSIONAL DRAWING
E
REV
1
SHT
20 5/8
[522.7]
21 1/16
[535.8]
[557.4]
21 15/16
26 3/8
[669.9]
[678.1]
29 1/2
[749.3]
28 3/4
[730.5]
26 11/16
AIR FLOW
3
[76.2]
1 3/4
[44.5]
AIR INTAKE
7/8
GAS CONN
[22.2]
7/8
3
[76.2 ]
PG92SCS
[22.2]
2 1/2
[63.5]
4
35
7/8
[101.6]
[889.0]
[22.2] POWER CONN
SIDE INLET
7/8
[22.2]
7/8
[22.2]
[442.3]
17 7/16
24
[609.7]
28 3/8
[720.4]
28 5/8
[726.9]
[757]
29 13/16
THERMOSTAT ENTRY
[420.9]
16 9/16
[458.6]
18 1/16
20 1/4
[513.9]
23 3/8
21 5/8
[549.5]
BOTTOM INLET
6 1/16
[154.0]
11/16
[17.5]
[592.0]
1 5/16
[668.8]
26 5/16
[33.3]
SD5024-4
PART NUMBER
NEXT SHEET
2
B
A
NOTES:
1. Doors may vary by model.
2. Minimum return-air openings at furnace, based on metal duct. If ex duct is used,
see ex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM-16-in. (406 mm) round or 14 1/2 x 12-in. (368 x 305 mm) rectangle.
b. For 1200 CFM-20-in. (508 mm) round or 14 1/2 x 19 1/2-in. (368 x 495 mm) rectangle.
c. For 1600 CFM-22-in. (559 mm) round or 14 1/2 x 22 1/16-in. (368 x 560mm) rectangle.
d. Return air above 1800 CFM at 0.5 in. w.c. ESP on 24.5" casing, requires one of the following
congurations: 2 sides, 1 side and a bottom or bottom only. See Air Delivery table in this
document for specic use to allow for sucient airow to the furnace.
3. Vent and Combustion air pipes through blower compartment must
use accessory “Vent Kit - Through the Cabinet”. See accessory list for
Furnish a ______________________ 4--way multipoise gas--fired
condensing furnace for use with natural gas or propane (factory-authorized conversion kit required for propane).
Quality Assurance
Unit will be designed, tested and constructed to thecurrent ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit
will carry the CSA Blue StarR and Blue FlameR labels. Unit
efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
Equipment
Blower Wheel and PSC Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of PSC type shall be
permanently lubricated with sleeve bearings, of _______hp, and
have multiple speeds from 600--1200 RPM operating only when
motor inputs are provided. Blower motor shall be direct drive and
soft mounted to the blower scroll to reduce vibration transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.
(mm) X ________ in. (mm). An accessory highly efficient Media
Filter is available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted steel.
Draft Inducer
Draft inducer motor shall be single--speed PSC design.
Motor
Primary Heat
Primary heat exchangers shall be 3--Pass corrosion--resistant
aluminized steel of fold--and--crimp sectional design and applied
operating under negative pressure.
Secondary Heat
Secondary heat exchangers shall be of a stainless steel
flow--through of fin--and--tube design and applied operating under
negative pressure.
Controls
Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting
codes displayed via diagnostic flashing LED light on the control, a
self--test feature that checks all major functions of the furnace, and
a replaceable automotive--type circuit protection fuse. Multiple
operational settings available, including blower speeds for heating
and cooling.
__________in. (mm); height___________in. (mm) (casing only).
Height shall be _________in. (mm) with A/C coil and
_________________in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be ________AWG; maximum fuse size
of HACR--type designated circuit breaker shall be _________
amps.
Special Features
Refer to section of the product data identifying accessories and
descriptions for specific features and available enhancements.
PG92SCS
15
Page 16
PG92SCS
E2014 Payne Heating & Cooling Systems D7310 W. Morris St. D Indianapolis, IN 46231Edition Date: 12/14
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
C a t a l o g N o : S S --- P G 9 2 S C S --- 0 3
R e p l a c e s : S S --- P G 9 2 S C S --- 0 2
16
Loading...