AVAILABLE SIZES: Nominal sizes available (036, 048 and 060) to
CERTIFICATION:
ELECTRICAL RANGE: 208/230v, three phase in 036, 048 and 060
FAN MOTOR:
CABINET:
UNIT DESIGN:
meet the needs of light commercial applications.
All models are listed with UL, (U.S. and Canada), ARI, and CEC.
sizes; and 460v, three phase in 060 size.
The totally enclosed fan motor provides greater
reliability under adverse conditions and dependable performance for many years. The permanent
split capacitor type motor was designed for optimum efficiency. The motor was then qualified
under extreme conditions to help ensure a long,
reliable life.
A weather protective cabinet of prepainted steel is
protected underneath by a galvanized coating and
treated with a layer of zinc phosphate for a finish
that will last for many years. All screws on cabinet
exterior are coated for a long-lasting, rustresistant, quality appearance.
The copper tube, enhanced sine wave, aluminum
fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas
and foliage. The base pan is designed for easy
removal of water, dirt, and leaves.
COMPRESSOR:
3-PHASE
(SCROLL
COMPRESSOR
UNITS) MONITOR
BOARD:
SERVICE VALVES: Control board that monitors the electrical phase
SERVICEABILITY: One panel provides access to electrical controls.
LIMITED
WARRANTY:
Each compressor is protected with internal temperature- and current-sensitive overloads. An
internal pressure relief valve provides highpressure protection to the refrigerant system. For
improved serviceability, all models are equipped
with a compressor terminal plug.
Both service valves are brass, front seating type
with sweat connections. Valves are externally
located so refrigerant tube connections can be
made quickly and easily. Each valve has a service
port for ease of checking operating refrigerant
pressures.
and prevents compressor operation if wired
incorrectly.
Removal of top gives access to fan motor, compressor, and condenser coil.
Standard 1-year limited warranty on parts and 5year limited warranty on compressor.
Page 2
E
SOUND POWER (dBA) (A-wtd., non-pure tone corrected.)
UNIT
SIZE
036-A8255.064.073.074.572.060.564.0
048-A8261.967.571.877.176.572.966.9
060-A8258.067.578.076.076.073.067.0
NOTE: Tested in accordance with ARI standard 270.95. (Not listed with ARI.)
unit, 48 in. above unit, 6 in. on one side, 12 in.
on remaining side, and 24 in. between units for proper airflow.
2. Minimum outdoor operating ambient in cooling mode is
55°F, max. 125°F.
3. Series designation is the 14th position of the unit
model number.
4. Center of gravity .
DIMENSIONS (IN.)
K
J
AIR IN
H
G
F
E
N
/8-IN. DIA
AIR IN
TIEDOWN
3
(2) PLACES
KNOCKOUTS
AIR DISCHARGE
—3—
036A22-1/225-15/163-3/163/43-11/1618-1/819-3/422-1/414-3/819-9/1622-1/1610-3/810-3/41122-1/2 x 22-1/2
SIZESERIESABCDEFGHJKLMNP
UNIT
The data in this publication is displayed for all series, however, every series may not be available from manufacturer.
048A22-1/233-15/163-1/47/83-11/1618-1/819-13/1622-1/414-3/819-9/1622-1/1610-3/810-3/415-1/222-1/2 x 22-1/2
060A3029-15/163-1/47/86-1/223-1/227-1/429-3/42027-1/1629-9/1615-1/2141530 x 30
NOTE:
Page 4
METERING DEVICE
UNIT SIZE-SERIES
036-A70
048-A82
060-A93
* Piston listed is for any approved coil non-capillary tube combination.
Piston is shipped with outdoor unit and must be installed in an approved indoor coil.
Unit Volts—Hertz—Phase208/230-60-3208/230-60-3208/230-60-3460-60-3
Operating Voltage Range*187-253187-253187-253414-506
Compressor—Rated Load Amps10.012.816.08.0
Locked Rotor Amps70.091.0125.066.5
Condenser Fan Motor—Full Load Amps1.41.41.40.8
Min Unit Ampacity for Wire Sizing13.917.421.410.8
Min Wire Size (60°C/75°F Copper) AWG†14/1414/1412/1214/14
Max Wire Length (60°C/75°F) (Ft)‡65/6252/4966/63165/157
Max Branch Circuit Fuse Size**20303015
COMPRESSOR & REFRIGERANT
Compressor—TypeReciprocatingScroll
Temperature and Current ProtectionInternal Line Break
Refrigerant—Type and Amount (Lbs)R-22 5.00R-22 6.25R-22 8.31
Refrigerant Tubes (In. OD)
Vapor and Liquid (Up to 50 Ft)3/4 and 3/87/8 and 3/81-1/8 and 3/8
CONDENSER COIL & FAN
Coil Face Area (Sq Ft)9.112.418.5
Fan Motor—HP, Type, and RPM1/4 PSC and 11001/4 PSC and 1100
Volts—Hertz—Phase208/230—60—1208-230—60—1460—60—1
Condenser Airflow (CFM)250025003400
1-Stage Heat, 1-Stage CoolTSTATPPSAC01-B
Backplate for Standard ThermostatTSTATXXBBP01
Backplate for Programmable ThermostatTSTATXXPBP01
Outdoor Air Temperature SensorTSTATXXSEN01-B
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article
336-26.
‡ Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time-delay fuse or circuit breaker.
‡‡ Furnace model numbers P08UA, P08LA, and PG8HA are not compatible with this thermostat.
N/A—Not applicable in this application.
NOTES: 1. Control circuit is 24v on all units and requires external power source.
2. All motors/compressors contain internal overload protection.
3. Copper wire must be used from service disconnect to unit.
IDENTIFICATION NO.
PISTON*
SPECIFICATIONS
—4—
CHARGING SUBCOOLING
(TXV-TYPE EXPANSION DEVICE*)
UNIT SIZE
03615
04815
06015
048060
REQUIRED SUBCOOLING
(°F)
Page 5
ACCESSORY
Compressor Crankcase HeaterYesYesNo
Evaporator Freeze ThermostatYesNoNo
Winter Start ControlYes†NoNo
AccumulatorNoNoNo
MotorMaster® ControlYesNoNo
Wind BaffleSee low-ambient instructionsNoNo
Support FeetRecommendedNoRecommended
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV
Ball Bearing Fan MotorYes‡NoNo
* For tubing line sets between 80 and 200 ft and/or 20 ft vertical differential, (250 ft total equivalent length), refer to Residential’s Split Systems Long-Line
Application Guidelines.
† Only when low-pressure switch is used.
‡ Required for MotorMaster Low-Ambient Control (full modulation of motor speed).
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
1. Ball Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
SUGGESTED USE: Required on all units where Low-Ambient kit (full modulation feature) or MotorMaster® Control has been added.
2. Compressor Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication
on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.
SUGGESTED USE: When interconnecting tube length exceeds 80 ft.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. Use with low-ambient controller.
All commercial installations.
3. Compressor Sound Hood
Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2dBA.
SUGGESTED USE: Unit installed closer than 15 ft to quiet areas—bedrooms, etc.
Unit installed between 2 houses less than 10 ft apart.
4. Cycle Protector
Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has
been interrupted for any reason, including normal room thermostat cycling.
SUGGESTED USE: Installations in areas where power interruptions are frequent.
Where user is likely to ‘‘play’’ with the room thermostat.
All commercial installations.
Installations where interconnecting tube length exceeds 80 ft.
High-rise applications.
5. Evaporator Freeze Thermostat
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.
SUGGESTED USE: All units where winter start control has been added.
6. Filter Drier
A device for removing contaminants from refrigerant circulating in an air conditioning system: single-direction flow.
SUGGESTED USE: Suggested in all field-connected split-system air conditioners.
7. High-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 400
psig. Provides additional protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, cycle protector can
be used with this switch.
SUGGESTED USE: Installations exposed to very ‘‘dirty’’ outdoor air.
Installations where condenser inlet air temperature exceeds 125°F (51.7°C).
8. Liquid Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant
liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.
SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
In certain long line applications. (Refer to Long-Line Application Guideline.)
9. Low-Ambient Pressure Switch
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure
within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to
0°F (–17.8°C) when properly installed.
SUGGESTED USE: A Low-Ambient Pressure Switch or MotorMaster®—Low-Ambient Controller must be used when cooling operating is used at outdoor
temperatures below 55°F (12.8°C).
10. Low-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27
psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Also, provides additional protection against compressor damage due to loss of refrigerant
charge. To prevent rapid compressor recycling. Cycle protector can be used with this switch.
SUGGESTED USE: Where indoor coil is exposed to ‘‘dirty’’ air.
All commercial installations.
11. MotorMaster® Control
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing
temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ± 10°F.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F.
All commercial installations.
ACCESSORY USAGE GUIDELINE
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
No
—5—
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 80 Ft)
See Long-Line
Application
Guideline
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
No
PA10
Page 6
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued
12. Thermostatic Expansion Valve (TXV) Kits
A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the
evaporator. Kit includes valve, adapter tubes, and external equalizer tube.
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
13. Time-Delay Relay
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
14. Winter Start Control
An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions.
SUGGESTED USE: All air conditioners where low-ambient controller has been added.
† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Payne furnaces are equipped with TDR.
‡ Requires hard shutoff TXV; based on computer simulation.
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
TDR — Time-Delay Relay
TXV — Thermostatic Expansion Valve
N/A — Not Applicable
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan-coil or furnace-coil literature.
4. Minimum outdoor operating ambient in cooling mode is 55°F (12.8°C), maximum 115°F (46.1°C).
5. The dashes (—) appearing in the SEER WITH ACCESSORY TDR column indicate no improvement in efficiency due to time-delay function built
into unit as manufactured (see table).
PA10
—8—
Page 9
DETAILED COOLING CAPACITIES*
EVAPORATOR
AIR
CFMEWB
758595105115
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
PA10036-A Outdoor Section With CC5A/CD5AA036 Indoor Section
* Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
** Unit kW is total of indoor and outdoor unit kilowatts.
unit is located above outdoor unit, a slight variation in capacity may occur.
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 60 ft, indoor coil below = 200 ft.
6. For interconnecting refrigerant tube lengths greater than 80 ft or 20 ft vertical differential (250 ft total equivalent length), consult Long-Line Application Guideline available from equipment distributor.
7. Crankcase heater required when interconnecting refrigerant tube length exceeds 80 ft.
8. If any refrigerant tubing is buried, provide a minimum 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in.
may be buried without further consideration.
9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.