03/14/2012
Ins-40078-US PROXIMITY panel mount reader - UL
Technical Support
1.800.672.7298 supportUS@paxton-access.com
Technical help is available: Monday - Friday from 02:00 AM - 8:00 PM (EST)
Documentation on all Paxton products can be found on our web site - http://www.paxton-access.com/
For instructions in alternative languages - http://paxton.info/1000
Suitability
Security sensitive doors
Wet environments
Paxton
Compatible with hands free tokens
Mounting
Readers mounted together
12 inches
between readers
This reader is designed to read Paxton Tokens (Hitag2) and EM4100 tokens.
It will provide Clock and Data output for Paxton (Net2 / Switch2).
PAGE 1

Red 12v dc
Brown
Orange
Green
Yellow
Blue
Mauve
Black/White
Brown
Yellow
Reader 1
Orange
Keypad 1
+12v
0v
N.C.
N.O.
Com
N.C.
N.O.
Com
Alarm Output
0v
Contact
0v
Exit
0v
Tamper
PSU
Rx
Tx
Relay 1
Relay 2
Exit
Contact
Tamper
PSU
OK
5v
12v
Red
Brown
Orange
Green
Yellow
Blue
Mauve
Black/White
Brown
Yellow
Orange
Reader 2
Keypad 2
Power
Relay 1 Relay 2 Inputs
Network
CAT5 cable coding
White/Green
Green
White/Orange
Orange
1
2
3
4
Screen or spare cores
from network cable
CAUTION: for 12v d.c. readers only. For
correct connection of old 5v readers, refer to
instructions.
Serial number
241821
Test ID: 012345678901
z-1440
3 2 4 8 9 8 0 0 0 0 0 4
x R
Green
White/Green
1
Screen or spare cores from
network cable
White/O r ang e
3
O r ang e
4
K 1 r e d a e R d a
p y e 1
12V
Alarm Output
R l e a y 2
N.C.
N. O .
Com
N.C.
N. O .
Com
0 V
0V
Exit
0 V
PSU
0V
Contact
T ampe r
R l e a y 1
V 2
1
V
5
K O
T e p
m a
r
t c a t n o C
t
i
x E
R l e a y 1
x T
U
S
P
K eypad 2 Reader 2
s t u p n I
P e w o r
R l e
a
y
2
C A
n i d o c
e
l b a c
5 T g
k r
o w
t e N
+V out
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
0V out
Data
Load
Clock
t u
o V +
D E L d e R
D E L
r e
b m A
D E L n e e r G
0 D / a t a
D
1 D / k c
o l C
t c e t e D
a i d e M
t u o V 0
a t a D
d a o L
k c o l C
Net2
2
Wiring
Red 12V
Brown
Orange
Green
Yellow
Blue
Mauve
Exit
Contact
Black
Card reader or keypad
12v
0v
N.C.
N.O.
Com
Bell
PowerDoor relay
Alarm
witch
2
S
Control
unit
Inputs
CAUTION: For 12V d.c. readers only.
For correct connection of old readers,
refer to instructions.
Card reader or keypad
Inputs
Door relay
Power
Alarm
Bell
12V
0V
N.C.
N.O.
COM
CAUTION: For 12Vd.c.
readers only. For correct
connection of old readers,
refer to instructions.
Contact
Exit
Switch2
12V
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
0V
Options
Part number Description
390-135-US PROXIMITY panel mount reader
Net2 control unit
Cable extensions
Use Max length Type
Reader / Keypad 500 feet 8 core, shielded - Beldon 9538, Alpha 1298C (22AWG) or equivalent
Cable Specication
Switch2 control unit
PAGE 2

Parts Kit
Description
Not required Reader ts to studs on customer facia
Reader installation and test
The panel mount reader is designed to t into a door entry panel. It ts behind a reader aperture of industry standard
size (40 mm x 40 mm) and is supplied with a polycarbonate window to match. See front page for tting detail.
Holes are provided in each corner to t over 4 posts set in a 49 mm square formation. Fixings are not provided as
they will normally be supplied with the panel.
When powered up, the reader will beep and all the LED's should display. Presenting a user card to the reader will
cause the LED's to briey change to a single Green or Red LED.
Check the following FAQs section for assistance if any problems are encountered.
Maintenance
Following the completed installation of this equipment, no further maintenance or testing is required.
It is advisable to ensure that any third party backup power supplies or recovery procedures are checked regularly
to ensure that the operation of the Paxton system is not compromised.
Product compliance and limitations
To comply as a UL listed installation, the following conditions must apply:-
Server based functions (Antipassback, Time and Attendance, etc) have not been evaluated by UL and cannot be
used for UL 294 installations.
The use of Wiegand readers and the conguration software has not been evaluated by 'UL'
Wiring: - Where an equivalent cable / wire is used it must be ' UL Listed '
All interconnecting devices must be UL Listed.
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the
authorities having jurisdiction.
For CAN/ULC-S319 installations, terminals, leads and wiring methods must comply with CSA, C22.1, Canadian
electrical code, Part 1, safety standards for electrical installations.
The use of any add-on, expansion, memory or other module manufactured or supplied by the manufacturer's
representative will invalidate the CAN/ULC-S319 certication.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. Changes or modications not expressly
approved by the party responsible for compliance could void the user's authority to operate the equipment.
PAGE 3

Technical Help
Here is the list of topics about this product that receive the most technical support inquiries.
We list them here to help you speed up the installation and trouble shooting process.
1 - Readers/Keypads not working.
Q- Software settings - Conrm that the settings of the reader or keypad are correct.
Q- Connections - Check the wiring and integrity of the connectors. If possible, test this reader on the other port.
Q- Cable - To conrm that an extended reader cable is not at fault, wire the reader directly to the port.
Q- Supply voltage - Conrm that the voltage is within specication. (see table)
Q- User token - Conrm that the user token used for testing is OK by presenting it to a known working reader.
Q- Interference - Conrm whether the reader works when tested 'in hand' and not mounted on the wall.
Q Ensure PROXIMITY readers are not mounted back to back or that there is no interference from other RF devices.
2 - Net2. What to do if a user has no access - Check the reader LEDs when a card is shown.
Q- No LEDs - the reader has no power.
Q- No change in display - try the card on a known working reader. If there is still no response, replace the card.
Q- Green LED ashing when a card is presented; check relay 1 LED to check for activity and also the lock wiring.
Q- Red LED is ashing when a card is presented; check the validity of the user at the PC.
Q Check user's access level and ensure they should have access by clicking on Current Validity.
Q Check the 'Valid Until' date and conrm this has not expired.
Q- Reinstate the ACU from the doors screen. Select the ACU's you wish to reinstate and then click OK.
3 - Switch2 - Adding an additional card pack.
QYou need to be in possession of the original enrolment card. Present the original enrolment card to the reader and
Qthe Amber LED will ash, Green & Red LEDs will be off, then present the Enrolment card from the new card pack;
Qthe reader will beep and all LEDS will be lit. The additional cards will now be valid. Repeat this with each reader
Qand with any additional card packs. Any valid enrolment card can be used to add further packs. This is the same
Qfor enrolling function card packs onto a system.
4 - Switch2 - How to reset the controller.
Q1. Disconnect the power and remove the wires from the Green and Mauve terminals
Q2. Insert a wire link between the Green and Mauve terminals
Q3. Reconnect the power (the unit will bleep 4 times)
Q4. Disconnect the power and remove the link wire, reconnect the Green and Mauve wires
Q5. Reconnect the power (the unit will bleep 3 times per second). The unit is ready to be enrolled.
Specications
Electrical
Voltage
Current
Carrier frequency
Clock and data bit period
Environment
Operating temperatures - all items
Waterproof
Cable length
Read Range Token
Dimensions
Panel mount reader
Window size
Mounting studs - Square formation
Min
Min
-35 °C ( -31 °F )
IPX7
2” 11/2”
Width
2 1/4 ” 2 1/4 ”
40 mm (1 19/32”) 40 mm (1 19/32”)
49 mm (1 30/32”) 49 mm (1 30/32”)
+66 °C ( + 151 °F )
Max
150 mA
Max
Keyfob
Height
Hands Free Token
Not Compatible
See front page for position
12V DC
125 kHz
600 µs
Outdoor use
10 feet
Depth
11
/16 ”
-
Reader xings are in metric to match industry standard access panel readers
PAGE 4