Paxton Marine exit button User Manual

15/03/2010
Ins-30061 Marine exit button
Technical Support
01273 811011 support@paxton.co.uk
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Paxton
Suitability
With Net2 and Switch2 ACU’s
With compact systems
Mounted on metal surface
Fitting
Fix the backplate to the wall with the stainless steel screws provided in the tting kit. The small slot in the plate edge should
be positioned at the bottom.
Where the unit is to be tted to a smooth surface, bulkhead, etc. a gasket is supplied to provide a weatherproof seal between the backplate and the mounting surface. (The unit has its own integral seal)
Locate the unit in the keyhole slots provided in the backplate. Make sure that the locking pin is close to the slot in the edge of the backplate. Rotate the unit clockwise until the locking pin engages in the slot.
To remove the unit, insert a small screwdriver into the cut out provided and use it to lift the locking pin. The unit can then
be rotated anticlockwise to release it from the backplate.
Wiring
This unit uses solid state electronics to switch 0V to the Exit 0V output and therefore cannot be
EXIT
12V DC
power supply
0V
+12V DC
0V
Green LED
Exit 0V
used with circuits that require voltage free contacts.
Wiring to a Compact reader
The green LED on the exit button is
illuminated but will not ash when used
with compact readers.
+12V
Environment
Operating temperature
Outdoor Use
Cable length
Electrical
Voltage
Current
Dimensions
Specications
Min
-25 °C
Min
8V DC 14V DC
Diameter
106 mm 16 mm
+12V
0V
Electric release
Max
+55 °C
No
5 metres
Max
220 mA
Depth
THIS UNIT IS FOR INTERNAL USE ONLY.
This Exit button unit is designed to complement the PROXIMITY Marine reader. It has no moving parts and is waterproof to IPX7.
The use of capacitive sensing to determine the presence of a user’s nger does, however, make it unsuitable for
external use. The reason for this is that heavy rainfall / snow / etc. could activate the exit button in error.
The declaration of conformity is available on request. Contact details are provided at: http://paxton.info/596