![](/html/47/4789/47892f7910fb0bcddec0449d79059a909ba54358e54f7d735baf7a7368aaa854/bg1.png)
18/08/2011
Ins-30087 OEM PROXIMITY panel mount reader - Hitag 2 - Clock and Data
Suitability
Fitting
Security-sensitive doors
Mounted on metal surface
Wet environments
Readers mounted together
300 mm
between readers
Wiring
+12V DC
Red LED
Amber LED
Green LED
Data
Open collector
Clock
Not required
0V
Pull directly to
0V to light LED
![](/html/47/4789/47892f7910fb0bcddec0449d79059a909ba54358e54f7d735baf7a7368aaa854/bg2.png)
Output format
Ts u
Tclklo
Thold
Tclk
Da
Data 0
Data Period ( Tclk ) 600 µs
Data Setup Time (Tsu) 200 µs
Data Clock Low (Tclklo) 200 µs
Data Hold Time (Thold) 200 µs
Cable extensions
Readers can be extended using Belden CR9540 10-core
overall screened cable to a maximum of 100 metres.
Data 1
Environment
Operating temperature
Waterproof
Cable length
Electrical
Voltage
Current
Carrier frequency
Clock and data bit period
Dimensions
Panel mount reader
Window size
Mounting holes - 3.7 mm dia - square formation
Contents in box
PROXIMITY panel mount reader - Hitag 2 - Clock and Data
Window assembly
Instruction set
Specications
Min
-20 °C
IPX7
Min
9V DC 14V DC
Width
58 mm 58 mm
40 mm 40 mm
49 mm 49 mm
Max
+55 °C
Max
110 mA
Height
Outdoor Use
5 metres
125 kHz
600 µs
Depth
17 mm
See front page for position