Paxton Hands free read range tester User Manual

Ins-30094 Hands free read range tester
25/03/2010
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
01273 811011 support@paxton.co.uk
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
The test card is used to determine the range of the 125 kHz P series reader and its ability to transmit data to a hands free token. This will determine the range of the hands free system as the token must
rst receive the interface address before sending its own token number to the interface itself.
If the tester shows a Green indication conrming receipt of the reader data but the hands free system
is still unreliable, then the interface will need to be relocated to a better position.
The above label is attached to the test card itself. Please contact Technical Support or see the website if you require any further assistance.
AN1082 - Hands free - How does it work? < http://paxton.info/815 > AN1091 - How to achieve the best read range with hands free equipment < http://paxton.info/867 >