Paxton CARDLOCK User Manual

12/09/2011
Ins-30021 CARDLOCK compact
Technical Support
01273 811011 support@paxton.co.uk
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Suitability
Wet environments
Paxton
Security-sensitive doors
Mounted on metal surface
Fitting
Readers mounted together
Reader covers
A black plastic or satin chrome cover comes supplied with the reader.
Due to the close proximity of the circuit board to the reader housing,
it is normal for the reader to feel warm during operation.
Wiring
Exit button
(push to make)
+12V
Exit
0V
0V
12V DC power
supply
+12V
0V
Electric release
Wire outputs
+12V DC
12V DC release current rating must be less than 1A.
Reset - Use one method
1. Power down the unit.
2. Press and hold the exit button.
0V
Lock 12V
3. Power up the unit. It will give several quick beeps.
4. Wait for a further beep and then release and press the exit button twice more.
5. The reader will beep 3 times to conrm the reset.
OR
Lock 0V
1. Present Enrolment card.
2. Present Door open time card twice.
Exit input
3. Present Enrolment card.
4. Present Door open time card twice.
Exit 0V
5. WAIT FOR 5 SECONDS!
Enrolment Card - must be presented when the system is rst powered on
1 2 3 4
BEEP!
BEEP!
CARDLOCK
CARDLOCK
enrolment card
enrolment card
1. At installation, present this
1. To initialise the reader swipe this card ONCE.
card to the reader to validate
The green arrow light stops flashing.
the tokens in this pack.
2. To re-enrol a deleted card swipe this card and then
2. To re-validate a user token,
swipe the deleted card.
present this enrolment card
to the reader followed by the
user token.
Paxton Access
1. Take the enrolment card from the new pack of user cards.
2. Present the enrolment card to the reader.
3. The reader will beep as the enrolment card is acknowledged.
4. All cards in the pack are now valid. The enrolment card can now be returned to it's pack.
CARDLOCK
CARDLOCK
enrolment card
enrolment card
1. To initialise the reader swipe this card ONCE.
1. At installation, present this
The green arrow light stops flashing.
card to the reader to validate
the tokens in this pack.
2. To re-enrol a deleted card swipe this card and then swipe the deleted card.
2. To re-validate a user token, present this enrolment card
to the reader followed by the
user token.
Paxton Access
Issuing tokens
BEEP!
BEEP!
1 2 3 4
This card is used with systems where a fail open
electric release is used for the safe operation in the
event of a fire. Present the card to the reader to
drive a fail open release or a maglock. Present the
card again to revert to the fail closed operation
Paxton Access
FUNCTION CARD
fail open release
Shadow cards
1 2 3 4
CARDLOCK
User Card
CARDLOCK
CARDLOCK
User Card
CARDLOCK
User Card
CARDLOCK
User Card
User Card
User Card
CARDLOCK
User Card
CARDLOCK
User Card
CARDLOCK
CARDLOCK
User Card
CARDLOCK
User Card
CARDLOCK
User Card
CARDLOCK
User Card
User Card
CARDLOCK
CARDLOCK
User Card
CARDLOCK
User Card
CARDLOCK
User Card
User cards
1. On each page there are 4 'pairs' of cards - a 'User card' and a corresponding 'Shadow card' behind it.
2. Write the name of the user on the shadow card.
3. Issue the 'User card' to the user.
4. Keep the card pack containing the shadow cards in a safe place.
Bar a user
1 2 3 4
John Smith
CARDLOCK
User Card
John Smith
Swipe this card to bar:
Write name:
1. When a card is lost or stolen it is important to bar the card from your system to avoid unauthorized access.
2. To bar a card or token take it's corresponding shadow card from the card pack.
3. Present the shadow card to the reader. This will remove the lost card or token from your system.
4. A barred card can re-validated by presenting the enrolment card followed by the user card to the reader.
Fail open release card - Compact systems are fail closed as default
THIS CARD CAN ONLY BE USED WITH A FAIL OPEN LOCK.
1. Take the fail open release function card from the starter pack.
2. Present/swipe the card through the reader. The reader will beep for about a second.
3. The reader is now set to fail open mode. This allows safe operation of the door in case of re: The lock will
release when the power is cut.
4. To revert to fail closed mode, swipe the card again and the reader will beep once.
Door open time (seconds)
BEEP!
BEEP!
BEEP!
1 2 3 4
Paxton Access
FUNCTION CARD
silent operation
Present this card to silence the beeping noises
made by the reader. Present this card again to
re-enable the beeping noises
1 3 4
FUNCTION CARD
door open time card
The period that the door is unlocked for when a
valid token is presented is set as follows:
1. Present this card
2. Wait for the required period
3. Present this card again, the beeping will stop
Paxton Access
2
BEEP!
BEEP!
1. Take the 'door open time' card from the starter pack.
2. Present the card to the reader. The reader will start beeping.
3. Wait for the required period you wish the door to remain open.
4. Present the card again at the end of the period to set the open time. The beeping will stop.
Silent operation
1. Take the silent operation function card from the starter pack.
2. Present the card to the reader. The reader will beep.
3. The reader is now in silent operation mode.
4. Present the card again to disable silent operation mode. The reader will beep twice.
Specications
Features
Number of Users
Access levels (Colour Zones)
Time zones (with additional time clock)
Door open time
Exit button input
Can be used with fail OPEN locks
Can be used with fail CLOSED locks
Silent operation
Door Contact input
Alarm/bell output voltage
Electrical
Voltage
Current
Switchable current
Environment
Operating temperature
Waterproof
Reader head life
Dimensions
Min
1 10,000
1 3
1 2
1 60 secs
Min
11V DC 14V DC
Min
- 20 °C + 55 °C
IPX7
1,000,000
Width
34 mm 89 mm
Max
Max
110 mA
1A DC
Max
Height
Yes
Yes
Yes
Yes
No
No
Outdoor Use
Depth
34 mm
Loading...