Ins-40002-US PROXIMITY P series reader - UL
Technical Support
1.800.672.7298 supportUS@paxton-access.com
Technical help is available: Monday - Friday from 02:00 AM - 8:00 PM (EST)
Documentation on all Paxton products can be found on our web site - http://www.paxton-access.com/
Mounting
Paxton
P75 Screw connector option
NOTE: The unit should be mounted in conjunction
with an electrical backbox to achieve the required
clearance for the connector.
If an adaptor plate (310-750-US) is tted, the
mountings on the backbox can also be used.
This unit is for Indoor use only
This reader is designed to read EM4100 tokens. It will provide Clock and
Data output for Paxton (Net2 / Switch2).
PAGE 1

Red 12v dc
Brown
Orange
Green
Yellow
Blue
Mauve
Black/White
Brown
Yellow
Reader 1
Orange
Keypad 1
+12v
0v
N.C.
N.O.
Com
N.C.
N.O.
Com
Alarm Output
0v
Contact
0v
Exit
0v
Tamper
PSU
Rx
Tx
Relay 1
Relay 2
Exit
Contact
Tamper
PSU
OK
5v
12v
Red
Brown
Orange
Green
Yellow
Blue
Mauve
Black/White
Brown
Yellow
Orange
Reader 2
Keypad 2
Power
Relay 1Relay 2Inputs
Network
CAT5 cable coding
White/Green
Green
White/Orange
Orange
1
2
3
4
Screen or spare cores
from network cable
CAUTION: for 12v d.c. readers only. For
correct connection of old 5v readers, refer to
instructions.
Serial number
241821
Test ID: 012345678901
z-1440
3 24898 00000 4
xR
Green
White/Green
1
Screen or spare cores from
network cable
White/Orange
3
Orange
4
K1 redaeR da
pye 1
12V
Alarm Output
R leay 2
N.C.
N.O.
Com
N.C.
N.O.
Com
0 V
0V
Exit
0 V
PSU
0V
Contact
Tamper
R leay 1
V2
1
V
5
KO
T ep
ma
r
tcatnoC
t
i
xE
R leay 1
xT
U
S
P
Keypad 2 Reader 2
stupnI
P ewo r
R le
a
y
2
CA
nidoc
e
lbac
5T g
kr
ow
teN
+V out
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
0V out
Data
Load
Clock
tu
o V+
DEL deR
DEL
re
bmA
DEL neerG
0D/ata
D
1D/kc
olC
tceteD
aideM
tuo V0
ataD
daoL
kcolC
Net2
2
Suitability
Security sensitive doors
Mounted on metal surface
Wiring
Wet environments
12V
Red 12V
Red LED
Brown
Amber LED
Orange
Green LED
Green
Yellow
Data/D0
Blue
Clock/D1
Mauve
Media Detect
Black
0V
Contact
n
o
C
Exit
xit
E
Card reader or keypad
tact
Switch2
S
witch
2
C
ard
er
w
read
Po
Control
er or
unit
ay
keyp
ad
oor rel
D
Inputs
CAU
TIO
:
N
Inp
CAUTION: For 12V d.c. readers
readers o
n
u
only. For corr ect connection of old
ts
nnectio
co
n
readers, re fer to instructions .
refer to in
stru
Readers mounted together
Net2 control unit
ell
B
Bell
larm
A
V
2
1
Alarm
l
of old
Fo
y.
PowerDoor relay
r 1
2V
For correct
rea
ctions.
12v
V
0
0v
.
.C
N
N.C.
.
N
O.
N.O.
M
O
C
Com
.c.
d
ders,
Switch2 control unit
(not evaluated by UL)
12 inches
between
readers
Part number Description
353-110-US PROXIMITY P50 reader
373-110-US PROXIMITY P75 reader
373-120-US PROXIMITY P75 reader - screw connection
Cable extensions
Use Max length Type
Reader / Keypad 500 feet 8 core, shielded - Belden 9538, Alpha 1298C (22AWG) or equivalent
NOTE: Where selected, any equivalent cabling / wire must be ' UL Listed '
Options
Cable Specication
All interconnecting devices must be UL Listed.
PAGE 2

Fitting Kit
Option Part number Description
P50 Fitting Kit fk1-085 (5) Cable clips
(3) No6 x
(3) Wall plugs 22 mm
(1) 8 mm x 3 mm small self tapping screw - zinc
P75 Fitting Kit fk1-084 (5) Cable clips
(3) No8 x 1 woodscrew - zinc
(3) Wall plugs 35 mm
(1) 8 mm x 3 mm small self tapping screw - zinc
3
/4 woodscrew - zinc
Unit installation / test
When chosing a location for the reader, ensure that it is a least 12 inches from other readers. This will include
readers mounted on the other side of the same wall as the radio signal will cause interference and reduce the read
range. The reader should not be used on metal surfaces as the reected signal will also reduce the read range.
Standard Unit - Drill a hole in the surface for the rear data cable. Secure the unit to the surface with three screws
as per tting diagram on page 1. 3 suitable screws and xings are provided for tting the unit to a wall. Ensure
the data cable has free access at the rear.
A choice of black and white covers are also provided. Hook the required cover over the top of the reader, press
home at the bottom and secure with the single xing screw.
Screw Terminal Unit - The adapter (310-750-US) is mounted to a standard backbox using the xing screws
provided. The 75mm reader is then mounted onto the adapter using the tting kit provided with the reader.
The reader will bleep and all the LEDS should display after powering on the control unit. Presenting a user card to
the reader will cause the LEDs to briey change to a single Green or Red LED.
Check the following FAQs section for assssistance if any problems are encountered.
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70),
local codes, and the authorities having jurisdiction.
Maintenance
Following the completed installation of this equipment, no further maintenance or testing is required.
It is advisable to ensure that any third party backup power supplies or recovery procedures are checked regularly
to ensure that the operation of the Paxton system is not compromised.
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Changes or modications not expressly approved by
the party responsible for compliance could void the user's authority to operate the equipment.
PAGE 3

Technical Help
Here is the list of topics about this product that receive the most technical support inquiries.
We list them here to help you speed up the installation and trouble shooting process.
1 - Readers/Keypads not working.
Q- Software settings - Conrm that the settings of the reader or keypad are correct.
Q- Connections - Check the wiring and integrity of the connectors. If possible, test this reader on the other port.
Q- Extended cable - Belden 9538/9540 should be used up to a maximum of 500 feet. Twisted pair alarm cable should
Q not be used. To conrm that an extended reader cable is not at fault, wire the reader directly to the port.
Q- Supply voltage - Conrm that the voltage is within specication. (see table)
Q- User token - Conrm that the user token used for testing is OK by presenting it to a known working reader.
Q- Interference - Conrm whether the reader works when tested 'in hand' and not mounted on the wall.
Q PROXIMITY readers should not be mounted back to back or close to other RF devices.
2 - Readers / Keypads - Extending cable.
QOnly Belden CR9538 / 9540 or a UL equivalent can be used for cable extensions. The maximum run is 500 feet.
3 - Net2 - Using a door reader as a desktop reader.
QIt is possible to congure a door reader to operate as a desktop reader:
Q1 - Select the doors menu in the left hand Net2 pane.
Q2 - Click on the door you wish to change the reader to act as a desktop reader.
Q3 - Under the relevant reader tab, change the reader operating mode to 'Desktop Reader'.
Q4 - The PC displays 'Would you like to accept desktop reader events from this reader at the PC?' ; click 'Yes'
Q Now when you present a blank or existing token to that reader it will allow you to add this new token or edit
Q the existing one.
NOTE:QRemember to return the operating mode to the original setting once the cards have been read
Q or users will not be able to gain access through the reader.
Q KP Reader - Ensure that Keypad type is set to 'None', otherwise the Desktop reader option will not be available.
4 - Net2. What to do if a user has no access - Check the reader LED's when a card is shown.
Q- No LED's - the reader has no power.
Q- No change in display - try the card on a known working reader. If there is still no response, replace the card.
Q- Green LED ashing when a card is presented; check relay 1 LED to check for activity and also the lock wiring.
Q- Red LED is ashing when a card is presented; check the validity of the user at the PC.
Q Check user's access level and ensure they should have access by clicking on Current Validity.
Q Check the 'Expires end' date and conrm this has not been past.
Q- Reinstate the ACU from the doors screen. Select the ACU's you wish to reinstate and then click OK.
Specications
Environment
Operating temperatures - all items
Waterproof - P50 and P75 IPX7
Waterproof - P75 - screw connection option
Cable length
Electrical
Voltage
Current
Carrier frequency
Clock and data bit period
Dimensions
P50
P75
Read Range
P50
P75
Min
-35 °C ( -31 °F )
Min
Width
2 inch 4 inch
3 inch 5
Token
3 inch 2 inch
4 inch 2
+66 °C ( + 151 °F )
Max
Outdoor Use
Indoor Use
10 feet
Max
12V DC
130 mA
125 kHz
600 µs
Height
1
/
2 inch
Keyfob Hands Free Token
1
/
2 inch
Depth
5
/
8 inch
5
/
8 inch
4 feet
5 feet
PAGE 4