![](/html/af/af80/af80614030ff15a664a00ba421391e084836c63a6ea6cd9a7bc4c5b37fb13ef6/bg1.png)
Manual
for
Hole Detectors PP2441...
Manual for Hole Detectors PP2441...
* E_431x2.doc * bis 03 TA/PS * (26.01.04 tb) * 09.01.07 tb *
Page 1
![](/html/af/af80/af80614030ff15a664a00ba421391e084836c63a6ea6cd9a7bc4c5b37fb13ef6/bg2.png)
General description
Manufacturer: Fotoelektrik Pauly GmbH & Co. KG, Germany
Type: PP2441(q)/…/…
One hole detector comprising (for each WPD):
1 - Transmitter PP2441(q)S/…/…
1 - Receiver PP2441(q)E/…/…
1 - Control Unit PP83201/2 – with 2m cable, with
plug (in case of PP2441(q)/308/R153, the
Control Unit is inside the Transmitter)
1 - Cable (4m) – with 2 plugs
Technical Characteristics
Housing Al-Cast
Weight see Datasheet
Protection Mode IP65
Supply Control Device 230/115VAC, 10VA
optional: 42…48VAC, 24VDC
Output Control Device Relay 250VAC/8A, 150W/1,500VA, 1xc-o-c
optional: pnp, e2; npn, e3; Optocoupler, e1
Transmitter Light GaAs 880nm, invisible
Steady Light Resistance >80kLx
Interference Suppressor Forced Synchronisation
Access Time “normal”: Recommended working range: ≥18ms/Switch Transition
Limit: ~12ms/Switch Transition
“q” (optional): Recommended working range: ≥3ms/Switch Transition
Limit: ~1,5ms/Switch Transition
“qq” (optional): Recommended working range: ≥1ms/Switch Transition
Limit: ~0,5ms/Switch Transition
Switching Frequency Relay: 10/s; electronic.: 40/s (normal), 300/s (q)
Switch Indicator LED
Time Delay 0-3s switch-on-off-delaying, z3
Ambient Temperature -25…60°C
Manual for Hole Detectors PP2441...
* E_431x2.doc * bis 03 TA/PS * (26.01.04 tb) * 09.01.07 tb *
Page 2