PAULMANN PLM 94314 Instructions

Safety Instructions
0, 1, 2, 3, 6, 11, 15, 18, 23, 25, 27
Info
www.paulmann.com
Paulmann Licht GmbH Quezinger Feld 2 31832 Springe Germany
www.paulmann.com
Art.-Nr.: 943.14
1
2
21
3
20
4
19
18
5
17
(+MA 173) PAEA 08/19
6
16
7
15
8
14
9
10
13
11
12
1x 4x
A
C D
6mm
B
1
21
2
3
20
19
4
18
5
17
6
16
7
15
8
9
14
10
13
11
12
Safety Instructions
Nr. 0
H07RN-F 3G1,5mm2 or the cables having equivalent parameters
off
N
40mm
L
N
L
E F
IP44
1
21
2
3
20
19
4
18
5
17
6
16
7
15
8
9
14
10
13
11
12
N
L
1
21
2
3
20
19
4
18
5
17
6
16
7
15
8
9
14
10
13
11
12
1
21
2
3
20
19
4
18
5
17
6
16
7
15
8
9
14
10
13
11
12
Safety Instructions
0, 1, 2, 3, 6, 11, 15, 18, 23, 25, 27
Info
www.paulmann.com
Paulmann Licht GmbH Quezinger Feld 2 31832 Springe Germany
www.paulmann.com
Art.-Nr.: 943.14
1
2
21
3
20
4
19
18
5
17
(+MA 173) PAEA 08/19
6
16
7
15
8
14
9
10
13
11
12
1x 4x
Instruction manual for mechanical timer
1
21
2
3
20
19
4
18
5
17
6
16
7
15
8
9
14
10
13
11
12
6mm
1
15
16
17
18
19
20
21
12
11
13
14
22
23
10
9
ON
OFF
1
24
8
7
Current time
6
5
4
3
2
Hour indicator 1 to 24 h
Setup procedures: push indicator outside, each
indicator 15min, power on when indicator is pushed
to outside. e.g.: setup timer working on 8:00am-11:00
am and 13:00pm-17:00pm, only need to push all the
indicators which belong to these two periods outside.
Set current time: turn the dial clockwise, make
the triangle arrow point to the current moment. e.g.:
current time 8:00am, turn the dial clockwise, make
the triangle arrow points to the number 8.
Push green time switch to location, then the
controlled electrical appliances will be set and had
timer function. Push green time switch to ”I” location,
then no timer function for controlled electrical
appliances.
Note: If the indicator which is pointed by the
triangle arrow can not be pushed outside, just turn
the dial clockwise and make this indicator is not
pointed.
If there is power off, must recalibrate current
moment
Unless change the setting, otherwise keep the
same setup procedures everyday
Caution, risk of electric shock! Do not disass-
emble the mechanical timer. When repairing, please
always consult a qualified electrician in accordance
with local safety regulations for help and use
originalt.
Connect power and set hour indicator according to actual time
2
15
16
17
18
19
20
21
12
11
13
14
22
23
10
9
ON
OFF
1
24
8
7
6
5
4
3
2
Time switch active 15 min
Set timer, push indicator outside (each indicator 15 min)
3
15
16
17
18
19
20
21
12
11
13
14
22
23
10
9
ON
OFF
1
24
8
7
6
5
4
3
2
Time switch on/off
- Activate timer
- Deactivate timer
I
Loading...