Patton electronics OnSite 07MOS10xx-GS, OnSite 1063, OnSite 1052 Series, OnSite 1063 Series Getting Started Manual

OnSite 1052 &1063 Series
Metro-Optical Transport Access Nodes
Getting Started Guide
Important
This is a Class A device and is not intended for use in a residential environment.
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
Part Number: 07MOS10xx-GS, Rev. B
Revised: October 25, 2010
Patton Electronics Company, Inc.
7622 Rickenbacker Drive
Gaithersburg, MD 20879 USA
Tel: +1 (301) 975-1000 Fax: +1 (301) 869-9293
Support: +1 (301) 975-1007
Web: www.patton.com
E-mail: support@patton.com
Copyright © 2010, Patton Electronics Company. All rights reserved.
The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document.
The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license.
Summary Table of Contents
1 Product Overview.......................................................................................................................................... 14
2 Application Overview.................................................................................................................................... 18
3 Installation Overview .................................................................................................................................... 23
4 System Management Access........................................................................................................................... 39
5 Contacting Patton for assistance ................................................................................................................... 53
A Compliance information .............................................................................................................................. 56
B Specifications ................................................................................................................................................ 58
C Terms and Acronyms .................................................................................................................................... 63
3
Table of Contents
Summary Table of Contents ........................................................................................................................... 3
Table of Contents ........................................................................................................................................... 4
List of Figures ................................................................................................................................................. 7
List of Tables .................................................................................................................................................. 8
About this guide ............................................................................................................................................. 9
Audience................................................................................................................................................................. 9
Structure............................................................................................................................................................... 10
Precautions........................................................................................................................................................... 10
Safety when working with electricity ...............................................................................................................11
Optical Safety .................................................................................................................................................12
Fiber-Optic Ports ......................................................................................................................................12
Fiber-Optic Safety Precautions ..................................................................................................................12
Typographical conventions used in this document................................................................................................ 13
General conventions .......................................................................................................................................13
Mouse conventions .........................................................................................................................................13
1 Product Overview.......................................................................................................................................... 14
Introduction..........................................................................................................................................................15
OnSite Platforms ............................................................................................................................................15
2 Application Overview.................................................................................................................................... 18
OS1052 Application..............................................................................................................................................19
OS1063 Application..............................................................................................................................................21
3 Installation Overview .................................................................................................................................... 23
Introduction..........................................................................................................................................................24
Unpacking and Inspection.....................................................................................................................................24
Site Preparation.....................................................................................................................................................24
Site Environment ..................................................................................................................................................25
Planning Your Site.................................................................................................................................................25
Site Requirements ...........................................................................................................................................25
Operating Environment Requirements ......................................................................................................26
Power Supply Requirements ......................................................................................................................27
Distribution Rack Requirements ...............................................................................................................27
Mechanical Recommendations for the Rack ...................................................................................................28
Protective Grounding for the Rack and Chassis ..............................................................................................28
Space Requirements for the Rack ....................................................................................................................28
Securing the Rack ...........................................................................................................................................28
Tools and Equipment for Installation and Maintenance........................................................................................29
OnSite System Installation
Mounting the Chassis to an EIA/TIA 19-Inch Rack .......................................................................................29
....................................................................................................................................29
4
OnSite Series Getting Started Guide
Mounting the Chassis to an ETSI Rack ..........................................................................................................30
Mounting the Chassis on the Wall ..................................................................................................................32
Installing the Chassis Ground Connection ......................................................................................................33
Connecting Power to the OS-10 System .........................................................................................................33
Connecting AC Power to the OS-10 System .............................................................................................34
Powering On the OS-10 System with AC Power ......................................................................................35
Connecting DC Power to the OS-10 System ............................................................................................35
Wiring Procedure for DC Input Power .....................................................................................................35
Checking the OS-10 System Installation .........................................................................................................38
4 System Management Access........................................................................................................................... 39
Introduction..........................................................................................................................................................40
General Overview..................................................................................................................................................40
Ethernet LAN Management Port ..........................................................................................................................41
Serial Management Port........................................................................................................................................42
Gaining Access to the System ................................................................................................................................43
Access through the Serial Port .........................................................................................................................43
Access through the Ethernet LAN Management Port ......................................................................................44
Web-Based Management Interface ........................................................................................................................45
Launching the GUI Application .....................................................................................................................45
Autonomous Alarm Messages ................................................................................................................................47
Engineering Orderwire (EOW) .............................................................................................................................49
5 Contacting Patton for assistance ................................................................................................................... 53
Introduction..........................................................................................................................................................54
Contact information..............................................................................................................................................54
Warranty Service and Returned Merchandise Authorizations (RMAs)...................................................................54
Warranty coverage ..........................................................................................................................................54
Out-of-warranty service .............................................................................................................................54
Returns for credit ......................................................................................................................................54
Return for credit policy .............................................................................................................................55
RMA numbers ................................................................................................................................................55
Shipping instructions ................................................................................................................................55
A Compliance information .............................................................................................................................. 56
Compliance ...........................................................................................................................................................57
EMC ...............................................................................................................................................................57
Low-Voltage Directive (Safety) .......................................................................................................................57
PSTN .............................................................................................................................................................57
Declaration of Conformity....................................................................................................................................57
Authorized European Representative.....................................................................................................................57
B Specifications ................................................................................................................................................ 58
Model OS1052......................................................................................................................................................59
Trunk Interfaces .............................................................................................................................................59
Client Interfaces ..............................................................................................................................................59
5
OnSite Series Getting Started Guide
Expansion Modules .........................................................................................................................................59
Configuration & Port Capacity for 2 Expansion Slots .....................................................................................59
Protection .......................................................................................................................................................59
Bandwidth Connectivity and Provisioning ......................................................................................................59
Timing & Synchronization .............................................................................................................................59
System Access .................................................................................................................................................59
Operations ......................................................................................................................................................60
Management ...................................................................................................................................................60
Packet Intelligence ..........................................................................................................................................60
Dimensions .....................................................................................................................................................60
Weight ............................................................................................................................................................60
Cooling ...........................................................................................................................................................60
Mounting .......................................................................................................................................................60
Power ..............................................................................................................................................................60
Environment ...................................................................................................................................................60
Model OS1063......................................................................................................................................................61
Trunk Interfaces .............................................................................................................................................61
Client Interfaces ..............................................................................................................................................61
Expansion Modules .........................................................................................................................................61
Configuration & Port Capacity for 2 Expansion Slots .....................................................................................61
Protection .......................................................................................................................................................61
Bandwidth Connectivity and Provisioning ......................................................................................................61
Timing & Synchronization .............................................................................................................................61
System Access .................................................................................................................................................61
Operations ......................................................................................................................................................62
Management ...................................................................................................................................................62
Packet Intelligence ..........................................................................................................................................62
Dimensions .....................................................................................................................................................62
Weight ............................................................................................................................................................62
Cooling ...........................................................................................................................................................62
Mounting .......................................................................................................................................................62
Power ..............................................................................................................................................................62
Environment ...................................................................................................................................................62
C Terms and Acronyms .................................................................................................................................... 63
Abbreviations ...............................................................................................................................
.........................64
6
List of Figures
1 OnSite Model 1052 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2 OnSite Model 1063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3 OS1052 Base System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4 OS1063 Base System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5 Typical OS1052 application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6 OS1052 Map + Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7 Typical OS1063 application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
8 OS1063 Map + Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
9 Grounding Terminal Location for the OS-10 System Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10 Mounting the OS-10 System Chassis in an EIA/TIA 19-Inch Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
11 Mounting the OS-10 System in an ETSI 300-mm Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
12 Mounting the OS-10 System Chassis on a Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
13 Wiring the OS-10 System for DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
14 Serial and LAN Management Ports on the Base OS1052 and OS1063 Systems . . . . . . . . . . . . . . . . . . . . . . . . 40
15 Detail of the Management Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
16 Location of Signal Pins on the RJ-45 Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
17 Web-Based Management GUI Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
18 Configuring an SNMP Trap Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
19 Configuring an Authorized OnSight NMS Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
20 Location of EOW port (AUX 1) on OS-10 Series Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
21 Location of signal pins on the EOW port (AUX 1) RJ-11 connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
22 Configuring the Engineering Orderwire (EOW) Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7
List of Tables
1 General conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2 Mouse conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3 Base System Configuration for OnSite Platforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4 Environmental Conditions for Operating the OS-10 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
5 Power Requirements for the OS-10 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6 Ground Wire Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7 OS-10 Power Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8 Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
9 DC Wiring Requirements for the OS-10 System Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
10 Ethernet LAN Management Port Cabling Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
11 Pin Assignments for the Ethernet LAN Management Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
12 Pin Assignments for the RS-232 Serial Management Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
13 RS-232 Serial Port Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
14 VT100 Terminal Emulation Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
15 Web-Based Management GUI Frame Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
8
About this guide
This guide describes how to install a Patton OnSite Series Model 1052 and1063 Metro-Optical Transport Access Node. For detailed configuration and management instructions, refer to the OnSite 1052 & 1063 Series Administrator’s Reference Guide, which is located on the CD-ROM that came with your unit and at www.pat­ton.com.
Installation, maintenance, and removal of a chassis or its components must be done by qualified service per­sonnel only. Qualified service personnel have had appropriate technical training and experience that is neces­sary to be aware of the hazards to which they are exposed when performing a task and of measures to minimize the danger to themselves and other people.
You should consider the following before unpacking your equipment:
Install the equipment in a secured, enclosed, and restricted access area, ensuring that only qualified service
personnel have access to the equipment.
Install the equipment only in a temperature and humidity-controlled indoor area that is free of airborne
materials that can conduct electricity.
When you handle equipment that has expansion modules, put on the electrostatic discharge (ESD) wrist
strap to reduce the risk of electronic damage to the equipment.
Note
Leave the ESD strap permanently attached to the chassis or rack so that it is always available when you need to handle ESD-sensitive components.
Read the following safety information thoroughly before installing your OS­10 system. Failure to follow this safety information can lead to personal
WARNING
injury or damage to the equipment.
Audience
This guide is intended for the following users:
Operators
Installers
Maintenance technicians
9
OnSite Series Getting Started Guide
Structure
This guide contains the following chapters and appendices:
Chapter 1 describes the OnSite Series Metro-Optical Transport Access Nodes
Chapter 2 describes typical applications for the OS-10 series
Chapter 3 describes instructions for installing the OS-10
Chapter 4 describes how to access the OS-10 for configuration and management
Chapter 5 contains information on contacting Patton technical support for assistance
Appendix A lists compliance information
Appendix B contains specifications for the OS-10 series
Appendix C contains a reference for terms and acronyms found in this guide
For best results, read the contents of this guide before you install the OS-10 platforms.
Precautions
Notes and cautions, which have the following meanings, are used throughout this guide to help you become aware of potential problems. Warnings relate to personal injury issues, and Cautions refer to potential property damage.
Note
WARNING
WARNING
CAUTION
CAUTION
Calls attention to important information.
The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.
The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.
The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.
The alert symbol and CAUTION heading indicate a potential haz­ard. Strictly follow the instructions to avoid property damage.
10
OnSite Series Getting Started Guide
Safety when working with electricity
Do not open the device when the power cord is connected. For systems without a power switch and without an external power adapter, line volt­ages are present within the device when the power cord is connected.
For devices with an external power adapter, the power adapter shall be a listed Limited Power Source The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker in compliance with local regu­latory requirements.
For AC powered devices, ensure that the power cable used meets all appli­cable standards for the country in which it is to be installed.
For AC powered devices which have 3 conductor power plugs (L1, L2 & GND or Hot, Neutral & Safety/Protective Ground), the wall outlet (or socket) must have an earth ground.
For DC powered devices, ensure that the interconnecting cables are rated for proper voltage, current, anticipated temperature, flammability, and mechanical serviceability.
WAN, LAN & PSTN ports (connections) may have hazardous voltages present regardless of whether the device is powered ON or OFF. PSTN relates to interfaces such as telephone lines, FXS, FXO, DSL, xDSL, T1, E1, ISDN, Voice, etc. These are known as “hazardous network voltages” and to avoid electric shock use caution when working near these ports. When disconnecting cables for these ports, detach the far end connection first.
Do not work on the device or connect or disconnect cables during periods of lightning activity
This device contains no user serviceable parts. This device can only be repaired by qualified service personnel.
If one has reason to open the chassis or case, then the precautions mentioned above shall be followed. This includes both the warnings relating to discon­nection of the input power, and the warnings relating to the disconnection of WAN, LAN & PSTN ports.
This device is NOT intended nor approved for connection to the PSTN. It is intended only for connection to customer premise equipment.
In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
11
OnSite Series Getting Started Guide
Electrostatic Discharge (ESD) can damage equipment and impair electrical cir­cuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. Do the following to prevent ESD:
Always follow ESD prevention procedures when removing and replacing cards.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin con­tact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground.
To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.
Optical Safety
Use fiber-optic ports only for telecommunications applications that require optical fiber. Use the ports only with the appropriate connector. When not in
WARNING
use, replace the dust covers. Using these interfaces in ways other than those described in this guide can cause property damage or personal injury.
Fiber-Optic Ports
To protect your eyes, never look at the transmit LED or laser through a magnifying device while it is powered on. Never look directly at a fiber port on the chassis or at the ends of fiber cable when they are powered on.
Note
The OS-10 system uses a CLASS 1 laser device.
Fiber-Optic Safety Precautions
Follow these safety precautions when working with fiber-optic cables:
Do not eat, drink or smoke in the work area. If fiber particles are ingested they could cause internal hemor-
rhaging.
Wear safety glasses with side shields to avoid getting fiber-optic splinters in your eyes.
Do not look into the end of a fiber cable until you are sure that there is no light source at the other end. Use
a fiber-optic power meter to ensure that the fiber is dark (that is, no power is being carried).
Ensure that the work area is well ventilated.
Do not touch your eyes while working with fiber-optic cables.
Wear disposable aprons to minimize fiber particles on your clothing.
Dispose of all cut fiber-optic pieces properly.
Thoroughly clean the work area when the installation is complete.
12
OnSite Series Getting Started Guide
Typographical conventions used in this document
This section describes the typographical conventions and terms used in this guide.
General conventions
The procedures described in this manual use the following text conventions:
Table 1. General conventions
Convention Meaning
Garamond blue type
Futura bold type Indicates the names of menu bar options.
Italicized Futura type
Futura type
Garamond bold type Indicates the names of command buttons that execute an action.
< >
Are you ready? All system messages and prompts appear in the Courier font as the
% dir *.* Bold Courier font indicates where the operator must type a response or
Indicates a cross-reference hyperlink that points to a figure, graphic, table, or section heading. Clicking on the hyperlink jumps you to the ref­erence. When you have finished reviewing the reference, click on the Go to Previous View button in the Adobe® Acrobat® Reader tool­bar to return to your starting point.
Indicates the names of options on pull-down menus. Indicates the names of fields or windows.
Angle brackets indicate function and keyboard keys, such as <Shift>, <Ctrl>, <C>, and so on.
system would display them.
command
Mouse conventions
The following conventions are used when describing mouse actions:
Table 2. Mouse conventions
Convention Meaning
Left mouse button This button refers to the primary or leftmost mouse button (unless you have
changed the default configuration).
Right mouse button This button refers the secondary or rightmost mouse button (unless you have
changed the default configuration).
Point This word means to move the mouse in such a way that the tip of the pointing
arrow on the screen ends up resting at the desired location.
Click Means to quickly press and release the left or right mouse button (as instructed in
the procedure). Make sure you do not move the mouse pointer while clicking a
mouse button. Double-click Means to press and release the same mouse button two times quickly Drag This word means to point the arrow and then hold down the left or right mouse but-
ton (as instructed in the procedure) as you move the mouse to a new location.
When you have moved the mouse pointer to the desired location, you can release
the mouse button.
13
Chapter 1 Product Overview
Chapter contents
Introduction..........................................................................................................................................................15
OnSite Platforms ............................................................................................................................................15
14
OnSite Series Getting Started Guide 1 • Product Overview
Introduction
The OnSite Series is family of ultra-compact, micro multi-service provisioning platforms ( MSPPs). The sup­ports flexible and economic delivery of time division multiplexing (TDM) and Ethernet-based packet data ser­vices over synchronous digital hierarchy (SDH) transport networks.
The OS-10 system has two STM-1 ports for connection to the SDH network. The ports operate at 155.520 Mbit/s and can be configured to operate as dual unprotected ports or as a protected pair using Linear 1+1 MSP. The STM-1 ports can also be configured in add-drop multiplexer (ADM) mode for operation in a ring net­work using SNCP path protection switching.
The OS-10 supports clear-channel mapping of E1/T1 and DS3/E3 signals into SDH payloads, and uses next­generation SDH features, such as generic framing procedure (GFP), virtual concatenation (VCAT), link capac­itiy adjustment scheme (LCAS) and advanced packet intelligence functions for efficient transport of Ethernet­based data services.
The OS-10 has one Ethernet LAN management port and one RS-232 serial port for access to the system man­agement functions. Remote access to OS-10 systems is possible through the use of an inband management channel that uses either a dedicated E1 link over a VC-12 or the SDH data communications channel (DCC).
The OS-10 chassis can be mounted into a standard 19-inch EIA/TIA or a 300-mm ETSI rack. The chassis also supports a wall-mounting option and can also be operated in a stand-alone desktop configuration.
The system uses natural convection cooling (that is, it contains no fans) and supports AC or DC power options.
All cabling, other than AC power, is accessible from the front panel of the chassis. The system also provides activity and status LEDs for all client-signal and SDH network interfaces. The system weighs approximately 5 kg (11 lbs) and has the following dimensions: 44.45 x 438.2 x 293 mm (height x weight x depth).
You can manage and access the OS-10 system through a simple Web-based graphical user interface (GUI) called the OnSight Device Manager (DM) or a scalable network management system (NMS).
OnSite Platforms
The OS-10 Series has two modular platforms: the OS1052 and OS1063. Table 2 provides a summary of the base system configuration for each platform.
Figure 1. OnSite Model 1052
Introduction 15
OnSite Series Getting Started Guide 1 • Product Overview
Figure 2. OnSite Model 1063
Table 3. Base System Configuration for OnSite Platforms
Type Model OS1052 Model OS1063
SDH Trunks 2 STM-1 2 STM-1 Client Signals 8 E1 or 8 T1 21 E1 or 21 T1
2 Ethernet
Management Serial RS-232 Serial RS-232
LAN LAN
Expansion Slots 2 2
The OS1052 and OS1063 systems have two expansion slots. The expansion slots support the insertion of the following modules for flexible configuration changes and capacity upgrades:
21-port E1
3-port DS3/E3
2-port STM-1 optical and electrical
8-port Ethernet 10/100BASE-TX
Figure 3 on page 17 shows the front and back panels of the OS1052 base system without the expansion mod-
ules installed. The OS1052 has eight built-in E1 and two built-in Ethernet 10/100BASE-TX interfaces. As a factory-installed option, the OS1052 is also available with eight T1 ports. The OS1052 uses a future bus con­nector for access to the 8 E1 or T1 ports on the base system.
Introduction 16
OnSite Series Getting Started Guide 1 • Product Overview
Figure 3. OS1052 Base System
Figure 2 shows the front panel of the OS1063 system. The OS1063 uses a future bus connector for access to the 21 E1 or T1 ports on the base system. When the system is equipped with two 21-port high-density E1 (HD-E1) expansion modules, the OS1063 provides access for up to 63 E1 ports. (See chapter 12 for a descrip­tion of the future bus connector and the features of the high-density E1 expansion module.) As a factory­installed option, the OS1063 is available with two STM-1 electrical interface (STM-1e) ports on the base sys­tem.
Figure 4. OS1063 Base System
Introduction 17
Chapter 2 Application Overview
Chapter contents
OS1052 Application..............................................................................................................................................19
OS1063 Application..............................................................................................................................................21
18
OnSite Series Getting Started Guide 2 • Application Overview
OS1052 Application
The advanced modular design of the Patton OnSite OS1052 provides unequaled flexibility in its class in terms of service offerings, capacity and functional upgrades.
OS1052 Application 19
Figure 5. Typical OS1052 application
OnSite Series Getting Started Guide 2 • Application Overview
The base OS1052 system is configured with:
2 STM-1
8 E1/T1
2 Ethernet
10/100Base-TX
Two expansion module slots allow increasing system capacity beyond the initial base configuration. Additional ports and features only require simple insertion of one of the many available types of TDM and packet data modules.
In only one RU, the OS1052 supports expansion up to:
50 E1 ports
18 Ethernet 10/100 ports
The OS1052 incorporates next-generation SDH features such as virtual concatenation (VCAT), link capacity adjustment scheme (LCAS) and generic framing procedure (GFP) for efficient packet data transport. The plat­form also incorporates Layer 2 features such as VLAN tagging, rate limiting and statistical multiplexing with multi-level QoS control. The OS1052 is easily configured and managed through a simple Web-based GUI interface or the scalable Patton OnSight NMS.
OS1052 Application 20
Figure 6. OS1052 Map + Modules
OnSite Series Getting Started Guide 2 • Application Overview
OS1063 Application
The advanced modular design of the Patton OnSite OS1063 provides unequaled flexibility in its class in terms of service offerings, capacity and functional upgrades.
OS1063 Application 21
Figure 7. Typical OS1063 application
OnSite Series Getting Started Guide 2 • Application Overview
The base OS1063 system is configured with:
2 STM-1
21 E1/T1
Two expansion module slots allow increasing system capacity beyond the initial base configuration. Additional ports and features only require simple insertion of one of the many available types of TDM and packet data modules.
In only one RU, the OS1063 supports expansion up to:
63 E1 ports
16 Ethernet 10/100 ports
The OS1063 incorporates next-generation SDH features such as virtual concatenation (VCAT), link capacity adjustment scheme (LCAS) and generic framing procedure (GFP) for efficient packet data transport. The plat­form also incorporates Layer 2 features such as VLAN tagging, rate limiting and statistical multiplexing with multi-level QoS control. The OS1063 is easily configured and managed through a simple Web-based GUI interface or the scalable Patton OnSight NMS.
OS1063 Application 22
Figure 8. OS1063 Map + Modules
Chapter 3 Installation Overview
Chapter contents
Introduction..........................................................................................................................................................24
Unpacking and Inspection.....................................................................................................................................24
Site Preparation.....................................................................................................................................................24
Site Environment ..................................................................................................................................................25
Planning Your Site.................................................................................................................................................25
Site Requirements ...........................................................................................................................................25
Operating Environment Requirements ......................................................................................................26
Power Supply Requirements ......................................................................................................................27
Distribution Rack Requirements ...............................................................................................................27
Mechanical Recommendations for the Rack ...................................................................................................28
Protective Grounding for the Rack and Chassis ..............................................................................................28
Space Requirements for the Rack ....................................................................................................................28
Securing the Rack ...........................................................................................................................................28
Tools and Equipment for Installation and Maintenance........................................................................................29
OnSite System Installation ....................................................................................................................................29
Mounting the Chassis to an EIA/TIA 19-Inch Rack .......................................................................................29
Mounting the Chassis to an ETSI Rack ..........................................................................................................30
Mounting the Chassis on the Wall ..................................................................................................................32
Installing the Chassis Ground Connection ......................................................................................................33
Connecting Power to the OS-10 System .........................................................................................................33
Connecting AC Power to the OS-10 System .............................................................................................34
Powering On the OS-10 System with AC Power ......................................................................................35
Connecting DC Power to the OS-10 System ............................................................................................35
Wiring Procedure for DC Input Power .....................................................................................................35
Checking the OS-10 System Installation .........................................................................................................38
23
OnSite Series Getting Started Guide 3 • Installation Overview
Introduction
This chapter provides the procedures for installing the OnSite OS-10 system.
Unpacking and Inspection
Do not unpack the OS-10 system until you are ready to install it. If the final installation site will not be ready for some time, keep the chassis in its shipping container to prevent accidental damage. When you are ready to install the unit, proceed with unpacking it.
Note
Do not discard the shipping cartons when you unpack the OS-10 sys­tem. Flatten and store them. You will need the containers if you need to move or ship the system. Repacking instructions will be provided in your return material authorization (RMA) paperwork.
To check the contents of the shipping cartons, follow these steps:
1. Check the contents of the shipping container and accessories box or bag against the content list and the packing slip which were included with your unit.
2. Verify that you received all listed equipment, including the following:
– OS-10 Series documentation (if ordered)
– Optional equipment that you ordered, such as network interface cables, or special connectors
3. Inspect all items for shipping damage.
Note
If anything appears to be damaged or you encounter problems install­ing or configuring your OS-10 Series chassis, contact customer ser­vice.
4. Check the expansion modules that may be located in each slot. Ensure that the configuration matches the packing list and that all specified interfaces are included.
Site Preparation
This section describes the requirements your site must meet for safe installation and operation of your OnSite OS-10 Series equipment. Ensure that the site is properly prepared before beginning installation.
The requirements described in this chapter are intended for the personnel responsible for installing and man­aging the network hardware. A working knowledge of telecommunications and local area network (LAN) operations and a familiarity with communications protocols that are used on interconnected networks are assumed. Installation, maintenance, and removal of a chassis, or its components must be done by qualified ser­vice personnel only. Qualified personnel have had appropriate technical training and experience that is neces­sary to be aware of the hazards to which they are exposed when performing a task and of measures to minimize the danger to themselves and other people. By carefully planning your site, you can maximize the performance of your existing network and ensure that it is ready to migrate to future service and capacity upgrades.
Introduction 24
OnSite Series Getting Started Guide 3 • Installation Overview
Site Environment
The OS-10 system can be mounted in a rack or on a wall. The location of the chassis and layout of your equip­ment rack or wiring room are extremely important for proper system operation. Equipment that is too close together, ventilation that is inadequate, and panels that are inaccessible can make system maintenance difficult or cause system malfunctions and possible shutdowns.
The following precautions help you plan an acceptable operating environment for your OS-10 system and avoid environmentally caused equipment failures:
Ensure that the room in which you operate your system has adequate air circulation. Electrical equipment
generates heat. Ambient air temperature might not be able to cool equipment to acceptable operating tem­peratures without adequate circulation.
Always follow the proper ESD-prevention procedures described in §3.2 (Electrostatic Discharge Damage)
to avoid damage to equipment. Damage from static discharge can cause immediate or intermittent equip­ment failure.
Ensure that the chassis cover and all expansion slot covers are secure. The chassis is designed to allow cool-
ing air to flow effectively inside it. An open chassis allows air leaks, which might interrupt the flow of cool­ing air from internal components.
When planning your site layout and equipment location, remember the following precautions to help avoid equipment failures and reduce the possibility of environmentally caused equipment problems.
Maximum recommended operating temperature – The maximum recommended operating temperature for the OS-10 is 50°C (122°F). Determine a suitable operating environment based on this recommendation.
Elevated operating ambient temperature – If the unit is installed in a closed or multiunit rack assembly, the operating temperature of the rack environment may be greater than the ambient temperature of the room. Keep this in mind when you install the unit.
Reduced airflow – Install the OS-10 system chassis in the rack so that the amount of airflow required for safe operation of the equipment is not compromised.
Mechanical load – Mount the OS-10 system chassis in the rack to avoid a potentially hazardous condition due to uneven mechanical loading.
Circuit overload – When you connect the OS-10 system chassis to the supply circuit, consider the effect that overloading of the circuits might have on over-current protection and supply wiring.
Reliable Ground – Maintain reliable grounding for the OS-10 system and all rack-mounted equipment, giving particular attention to supply circuits.
Planning Your Site
Site Requirements
To install your OS-10 equipment successfully, you should plan your site carefully. The site planning process has three major areas for consideration to ensure that your physical installation meets the requirements for a safe and successful installation:
Environmental, safety, and thermal requirements for the OS-10 system
Power and local building and electrical code requirements
Site Environment 25
OnSite Series Getting Started Guide 3 • Installation Overview
Distribution rack requirements
The following sections provide further details for each area.
Operating Environment Requirements
You need to verify that your site meets all environmental and safety requirements. During the early planning stages of installing or modifying your network, it is important that you develop a thorough understanding of the regulations that pertain to your location and industry.
Temperature – The OS-10 system generates a specified amount of heat as indicated on the data sheet. It is essential that you provide a temperature-controlled environment for both proper performance and safety.
Install the equipment only in a temperature- and humidity-controlled indoor area that is free of airborne mate­rials that can conduct electricity.
The following are some general thermal recommendations for your wiring closet or equipment room:
Ensure that the ventilation in the area is adequate to maintain a temperature below 50°C (122°F).
Install a reliable air conditioning and ventilation system.
Keep the ventilation in the wiring closet running during nonbusiness hours; otherwise, the equipment can
overheat.
Maintain the following ambient operating temperature: 0° to 50° C (32° to 122°F)
Maintain the following storage temperature: –40° to 70°C (–40° to 158°F)
Airflow requirements – To ensure proper airflow through the OS-10 equipment, follow these recommenda­tions when you are installing your chassis:
Leave 7.62 cm (3 inches) of minimum clearance on both the left and right sides of the chassis.
Leave a half-rack unit (RU) of minimum clearance above and below the chassis for properairflow.
Note
The OS-10 is a convection-cooled system, and adherence to these clearance requirements is required for proper operation of the system.
Humidity – Keep the operating humidity between 5 and 95 percent relative humidity (noncondensing).
Table 4 summarizes the acceptable operational conditions for the OS-10 system.
Table 4. Environmental Conditions for Operating the OS-10 System
Environment Minimum Maximum
Temperature Ambient operating 5°C +40°C
Short-term (96 hours) 0°C +50°C
Humidity Short-term (96 hours) 5% 80%
Short-term (96 hours) 5% 95%
Altitude Ambient operating –60 m 1800 m
Planning Your Site 26
OnSite Series Getting Started Guide 3 • Installation Overview
Power Supply Requirements
To operate your OS-10 equipment safely, follow these requirements:
Ensure that your power supply meets the site power requirements of the equipment to be installed.
Check the power at your site to ensure that you are receiving “clean” power (free of spikes and noise). Install
a power conditioner, if necessary.
Ensure that DC connections are made by an on-site electrician.
When connecting power to installed equipment, avoid connecting through an extension cord or apower
strip.
Table 5 summarizes the power requirements for the OS-10 system chassis.
Table 5. Power Requirements for the OS-10 System
Power Source
AC 110 or 220 VAC 1.0 A at 50 to 60 Hz 100 to 245 VAC DC –48 VDC 2.0 A –36 to –72 VDC
Note
If you system is shipped with the AC power option, use an AC power
Nominal Input
Voltage
Nominal Input
Current
cable appropriate for your country. Check your local electrical codes and regulatory agencies for power cable requirements.
Note
The system uses a universal AC power supply with an autoselection function for operation with either 110 V (60 Hz) or 220 V (50 Hz).
Distribution Rack Requirements
The OS-10 can be installed in either a 19-inch EIA/TIA or ETSI 300-mm rack.
Note
The 19-inch EIA/TIA rack should comply with the specification in EIA-310-D.
Note
The ETSI 300-mm rack should comply with the specification in ETSI EN 300 119-3 V2.1.0 (2004-05).
Tolerance L imits
Planning Your Site 27
OnSite Series Getting Started Guide 3 • Installation Overview
Mechanical Recommendations for the Rack
The following information will help you plan your equipment rack configuration:
Use a rack made of steel or aluminum.
Install equipment in the lower half of the rack first to avoid making the rack top heavy.
The rack should be able to support the full weight of the final installed chassis.
Enclosed racks must have adequate ventilation. Ensure that the rack is not overly congested because each
unit generates heat. An enclosed rack should have louvered sides and a fan to provide cooling air.
When mounting a chassis in an open rack, ensure that the rack frame does not block the cooling holes. If
the chassis is installed on slides, check the position of the chassis when it is seated all the way into the rack.
In an enclosed rack with a ventilation fan in the top, excessive heat generated by equipment near the bot-
tom of the rack can be drawn upward and into the intake ports of the equipment above it in the rack. In addition, ensure that you provide adequate ventilation for equipment at the bottom of the rack.
Baffles can help isolate exhaust air from intake air, which also helps draw cooling air through the chassis.
The best placement of the baffles depends on the airflow patterns in the rack, which can be found by exper­imenting with different arrangements.
Protective Grounding for the Rack and Chassis
Use a rack grounding kit and a ground conductor that is carried back to earth or another suitable building ground. The OS-10 chassis is designed with mounting brackets that provide solid metal-to-metal connection to the rack. If you do not use equipment racks, you can attach a wiring terminal directly to the chassis at the position indicated for appropriate grounding. Figure 9 shows the location of the grounding terminal location for the OS-10 chassis.
Figure 9. Grounding Terminal Location for the OS-10 System Chassis
Note
Because building codes vary worldwide, OnSite Systems strongly rec­ommends that you consult an electrical contractor to ensure that proper equipment grounding is in place for your specific installation.
Space Requirements for the Rack
Provide enough space in front of and behind the OS-10 system chassis so that you can service it easily. Typi­cally, allow a minimum of 122 cm (48 inches) in front of the rack and 61 cm (24 inches) behind the rack.
Securing the Rack
The rack should be attached to the equipment room floor with 9.5-mm (3/8-inch) lag screws or equivalent hardware. The floor under the rack should be level within 5 mm (3/16 inch). Use a floor-leveling cement com­pound if necessary or bolt the racks to the floor.
Planning Your Site 28
OnSite Series Getting Started Guide 3 • Installation Overview
Tools and Equipment for Installation and Maintenance
You need the following tools and equipment to install or upgrade the OS-10 system and its components:
ESD-preventive cord and wrist strap (when working with modular components or expansion cards)
Number 1 or number 2 Phillips screwdriver
Mounting brackets (provided); two are required for rack mounting or for wall mounting
8 screws (provided) to secure the L mounting brackets to the OS-10 system chassis (four screws for each
bracket)
A minimum of four 12-24 x 3/4-inch screws (not provided) to secure the OS-10 system chassis to the rack
Suitable screws and wall anchors to install an OS-10 system on a wall
Cable ties, if required, for organizing cables
In addition, depending on the type of modules you plan to use, you might need the following equipment to connect the OS-10 system to an external network:
Cables for connection to the fiber-optic and client signal ports (depending on configuration)
Ethernet hub or PC with a network interface card for connection to Ethernet LAN ports
Console terminal (an ASCII terminal or a PC running terminal emulation software) configured for 9,600
baud, 8 data bits, no parity, and 1 stop bit
OnSite System Installation
Note
WARNING
Mounting the Chassis to an EIA/TIA 19-Inch Rack
To install the OS-10 system chassis in an EIA/TIA 19-inch rack, see Figure 10 and follow these steps:
1. Install the two L mounting brackets in the orientation shown in Figure 10. Insert and fully tighten the screws to secure the brackets to the chassis (four screws for each bracket).
Note
Read the information in this section thoroughly and completely before you attempt to install or remove an OS-10 Series system chas­sis.
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
For this rack configuration, the L mounting bracket holes are flush with the front panel of the OS-10 system, as shown in Figure 4.
2. Position the chassis in the rack and align the mounting holes in the L bracket with the mounting holes in the equipment rack.
Note
The mounting-hole pitch for the 19-inch rack has the following repetitive pattern: 5/8”- 5/8”-1/2”.
Tools and Equipment for Installation and Maintenance 29
OnSite Series Getting Started Guide 3 • Installation Overview
Note
Note
Take care to load the rack so that it is not top heavy.
Do not cover vents that would restrict airflow. Leave a minimum of a half-rack space above and below the OS-10 system for adequate ven­tilation.
3. Secure the chassis using four 12-24 x 3/4-inch screws (two screws for each side) through the elongated holes in the L bracket nearest to the chassis and to the threaded holes in the mounting post. Use a suitable screwdriver for this task.
4. Tighten any loose captive installation screws on the expansion slot front panel covers.
Figure 10. Mounting the OS-10 System Chassis in an EIA/TIA 19-Inch Rack
Mounting the Chassis to an ETSI Rack
To install the OS-10 system chassis in an ETSI 300-mm rack, see Figure 11 and follow these steps:
1. Install the two L mounting brackets in the orientation shown in Figure 11. Insert and fully tighten the screws to secure the brackets to the chassis (four screws for each bracket). Use a suitable screwdriver for this task.
Note
For this rack configuration, the L mounting bracket holes are posi­tioned 50 mm back from the front panel of the OS-10 system, as shown in Figure 11.
2. Position the chassis in the rack and align the mounting holes in the L bracket with the mounting holes in the equipment rack.
Note
Note
OnSite System Installation 30
The mounting-hole pitch for the ETSI 300 mm rack is 25 mm.
Take care to load the rack so that it is not top heavy.
OnSite Series Getting Started Guide 3 • Installation Overview
Note
Do not cover vents that would restrict airflow. Leave a minimum of a half-rack space above and below the OS-10 system for adequate ven­tilation.
3. Secure the chassis using four 12-24 x 3/4-inch screws (two screws for each side) through the elongated holes in the L bracket nearest to the chassis and to the threaded holes in the mounting post. Use a suitable screwdriver for this task.
4. Tighten any loose captive installation screws on the expansion slot front panel covers.
Figure 11. Mounting the OS-10 System in an ETSI 300-mm Rack
OnSite System Installation 31
OnSite Series Getting Started Guide 3 • Installation Overview
Mounting the Chassis on the Wall
Note
When choosing a wall-mounting location, consider the cable limita­tions and the wall structure. Use the four L brackets provided for rack mounting to mount the chassis on a wall. The brackets provide the most stable installation for the chassis.
1. Install the two L mounting brackets in the orientation shown in Figure 12. Insert and fully tighten the screws to secure the brackets to the chassis (four screws for each bracket). Use a suitable screwdriver for this task.
Note
For this rack configuration, the L mounting bracket holes are flush with the bottom panel of the OS-10 system chassis.
2. Position the chassis against the wall using wall mount option 1 or option 2, as shown in Figure 12.
3. Secure the chassis to the wall using four 12-24 x 3/4-inch screws (two screws for each side) through the
elongated holes in the L bracket nearest to the chassis. Use a suitable screwdriver for this task.
4. Tighten any loose captive installation screws on the expansion slot front panel covers.
Figure 12. Mounting the OS-10 System Chassis on a Wall
OnSite System Installation 32
OnSite Series Getting Started Guide 3 • Installation Overview
Installing the Chassis Ground Connection
The OS-10 system chassis requires a reliable earth ground connection. You must connect the chassis to a reli­able earth ground. The ground wire must be installed in accordance with local electrical safety standards.
Table 6. Ground Wire Specifications
Grounding Standard Wire
EN/IEC 60950 AWG 18 (1 mm2) or larger wire and an
appropriate user-supplied ring terminal
NEBS AWG 6 (13 mm2) wire and the ground
lug provided in the accessory kit
NEC (National Electric Code) AWG 14 (2 mm2) or larger wire and an
appropriate user-supplied ring terminal
To connect the OS-10 system chassis to a reliable earth ground, follow these steps:
1. Strip one end of the ground wire to the length required for the ground lug or terminal.
Note
For the NEBS ground lug, the length is approximately 0.75 inches (20 mm)
Note
For a user-provided ring terminal—as required
2. Crimp the ground wire to the ground lug or ring terminal, using a crimp tool of the appropriate size.
3. Attach the ground lug or ring terminal to the chassis grounding terminal location shown in Figure 3.
4. Connect the other end of the ground wire to a suitable grounding point at your site.
After installation and proper grounding of the OS-10 chassis, you can connect the following:
Power wiring
Cables for the fiber-optic interface and Category 5 cables for E1 and Ethernet client signal interfaces
Category 5 cables for the Ethernet LAN and SERIAL management ports
Connecting Power to the OS-10 System
The system supports AC and DC power options, as listed in Table 7. These options are factory installed.
Table 7. OS-10 Power Options
Power Options Nominal Input Toleran ce L imit Feature
AC 110 VAC at 50 Hz and
220 VAC at 60 Hz
DC –48VDC –36 to –72 VAC Auto-switching AC to DC power converter
100 to 245 VAC Auto-switching AC to DC power converter
Note
Both AC and DC options provide short-circuit and over-voltage pro­tection.
Note
OnSite System Installation 33
The DC option provides reverse input polarity protection.
OnSite Series Getting Started Guide 3 • Installation Overview
Note
The DC-to-DC converter has dual power inputs (A and B power). The system continues to operate normally if either the A or B power input fails.
The system uses natural convection for heat dissipation (that is, it does not use fans). The absence of fans increases system reliability and eliminates periodic maintenance visits for fan filter replacement.Table 8 pro­vides the maximum power consumption figures for the OS-10 system under normal operating conditions.
Table 8. Power Consumption
System Configuration Maximum Power (W)
Base system 40 Base system with a single expansion module 50 Base system with dual expansion modules 60
This section explains how to connect the AC or DC power to the OS-10 system chassis.
Read the installation instructions before connecting the system to the power source.
WARNING
Do not work on the system or connect or disconnect cables during periods of lightning activity.
WARNING
The installation must comply with all required electrical codes applicable at the installation site.
Connecting AC Power to the OS-10 System
If your OS-10 system uses AC power, connect it to a 15 A at 120 VAC (or 10 A at 240 VAC) circuit with over­current protection.
Note
WARNING
The input voltage tolerance limits for AC power are 100 to 245 VAC.
•AC-connected units must have a permanent ground connection in addition to the power cable ground wire. NEBS-compliant grounding satisfies this requirement.
•This product relies on the installation of the building for short-circuit (over­current) protection. Ensure that the protective device is rated not greater than: 15A at 120 VAC (or 10 A at 240 VAC).
•The AC power supply for the OS-10 system has Double Pole/Neutral Fusing.
OnSite System Installation 34
OnSite Series Getting Started Guide 3 • Installation Overview
Powering On the OS-10 System with AC Power
To power on the OS-10 system using AC power, follow these steps:
1. Connect the AC power cable to the OS-10 system and then to the wall outlet.
2. Turn the power switch on the back panel of the OS-10 system to the ON position.
Note
The green PWR (power) LED on the front panel is lit when the sys­tem receives power from the AC source.
After turning off the AC power switch, wait for at least 3 seconds before turning it back to the on position.
CAUTION
Connecting DC Power to the OS-10 System
If your OS-10 system has a DC-input power supply terminal block on the front panel, follow the directions in this section for proper wiring.
This product relies on the installation of the building for short-circuit (over­current) protection. Ensure that the protective device is rated not greater than
WARNING
15 A at 60 VDC.
Table 9 summarizes the wiring requirements for the OS-10 system chassis with a DC-input power supply.
Note
For installations compliant with the National Electric Code, an AWG 14 (2.0 mm2) wire is required for DC input and safety ground wire.
Table 9. DC Wiring Requirements for the OS-10 System Chassis
DC Nominal Input DC Input Wire Size
–48 VDC at 2.0 A
AWG 18 (1.0 mm2) AWG 14 (2.0 mm2)
Safety Ground
Wire Size
Over-Current Protection
15 A
Note
The input voltage tolerance limits for nominal –48 VDC power sup­plies is –36 to –72 VDC.
Wiring Procedure for DC Input Power
To connect DC power to the OS-10 system, see Figure 13 and follow these steps:
•Connect the DC input wires to the OS-10 system with the following wiring sequence.
WARNING
OnSite System Installation 35
Figure 13
system. Wire the DC power supply as shown.
shows the terminal block for the DC power supply on the OS-10
OnSite Series Getting Started Guide 3 • Installation Overview
Figure 13. Wiring the OS-10 System for DC Power
1. Choose an available circuit from a DC power source and identify both the positive and negative leads for this circuit.
Note
The DC power source may be a DC circuit breaker or an AC-to-DC power rectifier.
•Do not touch the circuit with your hands or with any other instrument until you make sure that there is no power present on the circuit.
WARNING
•Make sure that power is removed from the DC circuit that will supply power to the OS-10 system before performing any of the following procedures.
2. Remove power from this circuit.
Note
To ensure that power is removed from the DC circuit, locate the cir­cuit breaker for the DC circuit, switch the circuit breaker to the OFF position, and tape the circuit-breaker switch in the OFF position.
3. Strip the DC input wires that will connect the circuit to the DC power terminal block on the OS-10 sys­tem to the appropriate length.
4. Connect the positive lead of this circuit to ground. See wiring 1-A in Figure 13.
Note
As an option, you may choose another common grounding point other than the one shown in Figure 13. The choice depends on the grounding practice for your particular location. Figure 13 shows the grounding point colocated with the DC circuit for “A” power.
OnSite System Installation 36
OnSite Series Getting Started Guide 3 • Installation Overview
The ground wire should always be connected first and discon­nected last.
CAUTION
5. Connect the positive lead of the circuit to the return direction for “A” power on the OS-10 system termi­nal block. See wiring 2-A in Figure 7.
Note
The terminal block indicates the return direction for “A” power by the letter R. This lead is second from the top on the OS-10 system terminal block.
Note
Step 4 and Step 5 results in the grounding of the return direction for
“A” power on the OS-10 system terminal block.
6. Connect the negative lead of the circuit to the “A” power input lead on the OS-10 system terminal block. See wiring 3-A on figure 13 on page 36.
Note
The terminal block indicates the “A” power lead by the letter A. This lead is first from the top on the OS-10 system terminal block.
Continue with the following steps if a second circuit is available for the provision of redundant “A” and “B” DC power inputs on the system. Otherwise, go directly to Step 10 to complete this task.
7. Connect the positive lead of this circuit to ground. See wiring 1-B on figure 13 on page 36.
Note
As an option, you may choose another common grounding point other than the oneshown in Figure 13. The choice depends on the grounding practice for your particular location. Figure 13 shows the grounding point colocated with the DC circuit for “B” power.
The ground wire should always be connected first and discon­nected last.
CAUTION
8. Connect the positive lead of the circuit to the return direction for “B” power on the OS-10 Series system terminal block. See wiring 2-B on Figure 13.
Note
The terminal block indicates the return direction for “B” power by the letter R. This lead is fourth from the top on the OS-10 system terminal block.
Note
Step 7 and Step 8 result in the grounding of the return direction for
“B” power on the OS-10 system terminal block.
OnSite System Installation 37
OnSite Series Getting Started Guide 3 • Installation Overview
9. Connect the negative lead of the circuit to the “B” power input lead on the OS-10 system terminal block. See wiring 3-B on figure 13 on page 36.
Note
The terminal block indicates the “B” power lead by the letter B. This lead is third from the top on the OS-10 system terminal block.
Do not over torque the terminal block captive thumbscrew or ter­minal block contact screws.
CAUTION
10. Secure the wires using cable ties or similar appropriate cable tie-downs.
11. Turn on power to the DC circuit.
Note
The green PWR (power) LED on the front panel is lit when the sys­tem receives power from the DC source.
Checking the OS-10 System Installation
When you first apply power to the system, the STAT (status) LED shows a solid amber light. This light indi­cates that the system is booting. The STAT LED turns to a solid green light when the system completes the boot process and is ready for operation.
OnSite System Installation 38
Chapter 4 System Management Access
Chapter contents
Introduction..........................................................................................................................................................40
General Overview..................................................................................................................................................40
Ethernet LAN Management Port ..........................................................................................................................41
Serial Management Port........................................................................................................................................42
Gaining Access to the System ................................................................................................................................43
Access through the Serial Port .........................................................................................................................43
Access through the Ethernet LAN Management Port ......................................................................................44
Web-Based Management Interface ........................................................................................................................45
Launching the GUI Application .....................................................................................................................45
Autonomous Alarm Messages ................................................................................................................................47
Engineering Orderwire (EOW) .............................................................................................................................49
39
OnSite Series Getting Started Guide 4 • System Management Access
Introduction
This chapter provides the procedures for configuring and monitoring the local serial and LAN management (LM) ports, and the inband management channel (IMC) for remote management communications. The chap­ter also provides the procedures for configuring and using the Orderwire communications port (if the AUX port is factory-installed).
General Overview
The base OnSite OS-10 system provides two management ports from which you can access the system man­agement functions. One of the management ports is an Ethernet LAN (10/100BASE-TX) port. The other is an RS-232 SERIAL port.
Figure 14 shows the location of the two management ports on the base OS1052 and OS1063 systems.
Figure 14. Serial and LAN Management Ports on the Base OS1052 and OS1063 Systems
Introduction 40
OnSite Series Getting Started Guide 4 • System Management Access
Figure 15 provides a close-up view of the two management ports. The figure includes the location of the RJ-45
connector pins for both ports.
Figure 15. Detail of the Management Ports
Figure 16 shows the location of the signal pins on the RJ-45 plug.
Figure 16. Location of Signal Pins on the RJ-45 Plug
Ethernet LAN Management Port
The Ethernet LAN management port complies with the following standards:
IEEE 802.3u (PHY)
IEEE 802.3 (MAC)
IEEE 802.3x (flow control)
The port supports autonegotiation, which is always enabled.
Table 10 provides the cabling specifications for the Ethernet LAN management port.
Table 10. Ethernet LAN Management Port Cabling Specifications
Cable Specification
Connector RJ-45 Type Category 5 Reach 100 m
Ethernet LAN Management Port 41
OnSite Series Getting Started Guide 4 • System Management Access
Table 11 provides the pin assignments for the RJ-45 connector.
Table 11. Pin Assignments for the Ethernet LAN Management Port
Signal Name Description RJ-45 Pin
RXN Receive tip 3 RXP Receive ring 6 TXN Transmit tip 1 TXP Transmit ring 2
Serial Management Port
The physical connector for the RS-232 SERIAL management port is an RJ-45 connector. Table 12 provides the pin assignments for the RJ-45 connector.
Note
A connector adapter is supplied with the system to allow the connec­tion of the RS-232 signal to a PC with a DB-9 connector.
Table 12. Pin Assignments for the RS-232 Serial Management Port
Signal Name Description RJ-45 Pin
RS232_TXD output Transmit data 6 RS232_RXD input Receive data 3 GND Ground 4 and 5
Table 13 lists the serial port parameters:
Table 13. RS-232 Serial Port Parameters
Parameter Property
Baud rate 9,600 to 38,400 (asynchronous) Data 8 bits Parity None Stop 1 bit
Table 14 lists the required VT100 terminal emulation settings for the PC that connects to the serial port.
Table 14. VT100 Terminal Emulation Settings
Serial Management Port 42
Parameter Setting
Port COM1 Baud rate 9,600 Data 8 bits Parity None Stop 1 bit Flow control None
OnSite Series Getting Started Guide 4 • System Management Access
Gaining Access to the System
There are two ways of gaining access to the system management functions. One way is through the SERIAL port and the command line interface (CLI). The other way is through the Ethernet LAN port and the web browser interface. The following sections describe the procedures for each of the access methods.
Access through the Serial Port
To gain management access to the system for the first time through the SERIAL port, follow these steps:
1. Connect a PC to the SERIAL management port.
Note
Use the DB-9-to-RJ-45 adapter cable supplied with the system.
2. Launch the VT100 terminal emulation program on the PC.
Note
Configure the terminal in accordance with the settings in Table 14.
3. Press the Enter key on the PC to obtain a login prompt from the system.
4. Log in to the system using the Super user ID and password.
Note
Note
Note
Only the Super user is able to perform the following task.
The user ID for the Super user is super (all lowercase letters).
The factory-assigned default password for the Super user is super (all lowercase letters).
After successful completion of the login, the system responds with the CLI (command-line interface) prompt.
Note
The CLI command prompt for the system is OnSite >
5. Type the following CLI command to configure the IP address for the Ethernet LAN management port, and then press the Enter key:
config mgmt-enet ip-address aaa.bbb.ccc.ddd
Note
aaa.bbb.ccc.ddd is the standard dotted-decimal notation.
6. Type the following CLI command to configure the net mask for the Ethernet LAN management port, and then press the Enter key:
config mgmt-enet ip-netmask aaa.bbb.ccc.ddd
7. Type the following CLI command to configure the default gateway for the Ethernet LANmanagement port, and then press the Enter key:
config mgmt-enet default-gateway aaa.bbb.ccc.ddd
Note
By default, the IP address is set to 192.168.2.100, the net mask is set to 255.255.255.0, and the default gateway is set to 192.168.2.1
Gaining Access to the System 43
OnSite Series Getting Started Guide 4 • System Management Access
8. Type the following CLI command to save the IP settings (address, net mask, and default gateway)for the Ethernet LAN management port to the system configuration file, and then press the Enter key:
save config
Note
Saving the configuration is important to prevent the loss of the IP configuration data if a system reset or reboot occurs.
Changing the IP address, net mask, and default gateway settings for the Ethernet LAN management port could result in the loss-of-
CAUTION
management connectivity to the system, if the connection is cur­rently through that port.
At this point, the system responds with Configuration Saved to indicate that the IP settings have been saved to the system. The system is now ready for operation using the Web-based management interface.
Note
You may also have access to the system through Telnet. This access requires prior configuration of the IP address of the Ethernet LAN management port through the RS-232 SERIAL port, as indicated in the preceding steps.
Note
The system terminates the management session for any user when the session remains inactive for 30 seconds. This termination applies to management sessions through the SERIAL port or through Telnet. The login prompt appears when the system terminates a previously active session through the SERIAL port.
Access through the Ethernet LAN Management Port
To gain management access to the system for the first time through the Ethernet LAN management (LM) port, follow these steps:
1. Connect a PC to the Ethernet LAN management port using the RJ-45 connector.
Note
You may connect the PC to the system from a remote location using an IP LAN or WAN that connects to the Ethernet LAN management port.
2. Configure the PC using the factory default settings for the Ethernet LAN management port.
Note
By default, the IP address is set to 192.168.2.100, the net mask is set to 255.255.255.0, and the default gateway is set to 192.168.2.1
3. Launch the Web browser of your choice, and type the default IP address of the system in the Address field of the browser.
4. Log in to the system using the super, admin, or monitor user ID and password.
Note
The factory-assigned default password for the Super user is super (all lowercase letters).
Gaining Access to the System 44
OnSite Series Getting Started Guide 4 • System Management Access
See “Web-Based Management Interface” on page 45 for a description of the Web-based management interface features. Once you gain access to the system through the Ethernet LAN port, you may change the IP settings for the port for secure access in the future.
5. Refer to the OnSite Series Administrator’s Reference Guide, located on the CD that came with your unit and online at www.patton.com for instructions on how to change the IP settings for the Ethernet LAN port.
Save the system configuration to prevent the loss of the new IP settings if a system reboot occurs.
CAUTION
Refer to the OnSite Series Administrator’s Reference Guide, located on the CD that came with your unit and online at www.patton.com for instructions.
Note
Once the changes take place, you will loose connectivity to the sys­tem, but you can regain access immediately by typing the new IP address of the system in the Address field of the browser.
Web-Based Management Interface
The system provides a simple but powerful Web-based management interface to configure and monitor the OnSite OS-10 system. This graphical user interface (GUI) is called the OnSight Device Manager (DM) and is accessible through a Web browser using Hypertext Transfer Protocol (HTTP).
Note
The OnSight DM allows you to have full access to the system management functions. These functions include the ability to set up or change all configurable items on the system and the ability to create and delete connec­tions between the client ports and SDH network interface. The interface also allows you to monitor and dis­play current active alarms, performance monitoring parameters, and alarm and event logs.
Launching the GUI Application
To launch the Web-based management interface, follow these steps:
Note
The system supports the following Web browsers: Microsoft Internet Explorer 6+, Netscape 7+, Mozilla 1.7+, and Mozilla Firefox 1.0+ on Windows, Solaris, and Linux platforms.
This procedure requires prior configuration of the IP address of the Ethernet LAN management port through the RS-232 SERIAL port or LAN port, as indicated in §6.4.
1. Connect the PC to the Ethernet LAN management port using the RJ-45 connector.
Note
You may connect the PC to the system from a remote location using an IP LAN or WAN that connects to the Ethernet LAN management port.
2. Launch the Web browser of your choice, and type the IP address of the system in the Address field of the browser.
3. Log in to the system using the super, admin, or monitor user ID and password.
Web-Based Management Interface 45
OnSite Series Getting Started Guide 4 • System Management Access
After successful completion of the login, the browser displays the OnSight DM splash screen from which you can select the language of your choice (English or Chinese, currently). After language selection, the browser displays the System Information page. The OnSight DM screen is divided into three frames, as shown in
Figure 17. Table 15 provides a description of each frame.
You may now start to configure and operate the system using the GUI interface.
Note
For proper display of the GUI interface, you must set your browser to allow “pop-up” windows.
Figure 17. Web-Based Management GUI Frames
Table 15. Web-Based Management GUI Frame Descriptions
GUI Frames Provides...
Status (top frame) An overview of the system identity, including the system
Navigation (bottom left frame) The main categories and subdivisions of system functions. Content (bottom right frame) The main area for information display and configuration.
Web-Based Management Interface 46
name and IP address, and the support contact information and status of active alarms.
OnSite Series Getting Started Guide 4 • System Management Access
Autonomous Alarm Messages
You can configure the system to generate autonomous alarm messages that can be received and displayed by an SNMP-based network management system (NMS).
By default, the system does not generate SNMP traps. To allow the generation of SNMP traps, you must first configure the IP address of the NMS host device or devices to which you wish to direct the traps.
To configure the system as an SNMP trap sender for an SNMP trap receiver, see Figure 12 and follow these steps:
1. Select the SYSTEM folder from the navigation menu.
2. From the expanded SYSTEM folder, select Management Access.
3. From the expanded Management Access folder, select Trap Receiver.
4. On the SNMP Trap Receivers page, click on Add.
5. In the Add New Trap Receiver page, type the Trap Receiver Address and Community String.
Note
The community string controls access between a client (the OS-10 system) and a server (the NMS host).
6. Set the Version to configure the system to send SNMP V1 or V2 traps.
7. Type the Source Agent Address of the SNMP agent.
Note
The OS-10 generates SNMP traps that contain the IP address of the source agent. By default, the system uses the address of the Ethernet LAN management port as the source agent address. However, you may use another address (for example, the inband management chan­nel address) according to the routing settings for the system.
8. Click on Close to close the window.
At this point, the Trap Receivers page displays the settings for the new receiver.
Figure 18. Configuring an SNMP Trap Receiver
Autonomous Alarm Messages 47
OnSite Series Getting Started Guide 4 • System Management Access
To remove an existing SNMP trap receiver, follow these steps:
1. Select a trap receiver on the SNMP Trap Receivers page.
2. Click on Delete to remove the trap receiver.
At this point, the system removes the trap receiver, and it is no longer displayed in the table.
In addition to supporting the generation of traps to an SNMP-based NMS, the system also sends autonomous messages to all connected OnSight NMSs. The OnSight NMS provides centralized management and control of OS-10 systems in point-to-point, linear, and ring ADM subnetworks.
To display the OnSight NMS servers authorized to manage the OS-10 system, see Figure 19 and follow these steps:
1. Select the SYSTEM folder from the navigation menu.
2. From the expanded SYSTEM folder, select Management Access.
3. From the expanded Management Access folder, select NMS.
On the Authorized NMS Servers page, the table displays the IP addresses of the OnSight NMS servers autho­rized for management connectivity to the system.
To add an OnSight NMS server to the list of authorized servers, see Figure 19 and follow these steps:
1. On the Authorized NMS Servers page, click on Add.
2. In the Add Authorized NMS Server window, type the NMS IP Address and click on Apply.
3. Click on Close to close the window.
Figure 19. Configuring an Authorized OnSight NMS Server
Autonomous Alarm Messages 48
OnSite Series Getting Started Guide 4 • System Management Access
Engineering Orderwire (EOW)
If the system is equipped with the factory-installed AUX (auxiliary) board, you can use AUX port 1 (AUX 1) for voice communications between two or more interconnected OnSite OS-10 Series systems.
Figure 20 shows the location of EOW port (AUX 1) on the system. The port is located on the right side of the
chassis, at the back.
Figure 20. Location of EOW port (AUX 1) on OS-10 Series Chassis
The EOW port supports a 2-wire analog interface (tip and ring) with a nominal impedance of 900-ohm and A-law PCM voice encoding. The system carries the PCM-encoded 64 kbit/s voice channel in either the E1 or E2 byte of the STM-1 section overheard (SOH).
As a Foreign eXchange Station (FXS) interface, the EOW port supports the following functions:
Dial tone
Battery current
Ring voltage
The system uses an RJ-11 connector for the EOW port (AUX 1) but only two pins are used for the 2-wire con­nection: pin 2 (tip) and pin 3 (ring), as shown in Figure 21.
Note
The “tip” is the ground side and the “ring” is the battery side of the 2­wire telephone circuit.
Engineering Orderwire (EOW) 49
OnSite Series Getting Started Guide 4 • System Management Access
To prevent electrical shock, never touch uninsulated wires or terminals when the phone line is plugged into the RJ-11 connector of the EOW port (AUX 1).
WARNING
Figure 21. Location of signal pins on the EOW port (AUX 1) RJ-11 connector
The EOW port supports dual-tone multifrequency (DTMF) signaling to identify EOW stations within an OnSite OS-10 subnetwork. Each EOW station is identified with a programmable 3-digit station ID number.
To configure the engineering orderwire (EOW) function, see Figure 16 and follow these steps:
1. Select the SYSTEM folder from the navigation menu.
2. From the expanded SYSTEM folder, select Management Access.
3. From the expanded Management Access folder, select Orderwire.
Note
If you see that the physical connector for the AUX 1 port is present but the Orderwire selection does not appear on the folder, check first that the system is operating using Release 4.3 or above.
4. On the Orderwire page, check that the AUX Board shows Installed and that the Operational Status is in- service (IS).
Note
If the AUX Board shows Not Installed or the Operational Status is out-of-service (OOS), and you see that the physical connector for the AUX1 port is present, contact your local systems engineer or regional OnSite support center for additional technical information.
5. On the Orderwire page, set the Station ID for the system.
Note
The Station ID needs to be a unique 3-digit number for each EOW station within an OnSite subnetwork. The available range of station ID numbers is 001 to 255.
Engineering Orderwire (EOW) 50
OnSite Series Getting Started Guide 4 • System Management Access
Note
In addition to supporting selective calling of EOW stations using the station ID, the EOW also supports a party-line function that allows calling and communicating with all EOW stations at once (party-line function) by dialing *000.
6. Set the Channel Byte to E2 (express orderwire byte) if there are SDH regenerators present between the STM-1 ports connecting two OnSite OS-10 nodes supporting the EOW function; otherwise, leave the default setting as E1 (local orderwire byte).
7. Set Termination to Termination Point if the EOW station is an OS-10 node in terminal mux configura- tion in a point-to-point link or at the end of a linear ADM chain. For OS-10 nodes in ADM configura­tion, leave the default setting as Intermediate Point.
Note
For OS-10 nodes in a ring network, one of the nodes must be set to
Termination Point while the rest of the nodes are set to Intermediate Point. This arrangement is necessary to prevent an audio feedback
loop. Normally, the OS-10 node serving as the master timing node for the ring is set to Termination Point.
8. Click on Apply to complete the configuration of the EOW port.
Figure 22. Configuring the Engineering Orderwire (EOW) Function
After the EOW port is configured for operation, you can connect a regular 2-wire touchtone telephone set to the RJ-11 connector of the port. To establish a voice call with another EOW station on the same OnSite OS­10 subnetwork, take the phone “off-hook”, wait for dial tone, and then dial star (*) followed by the Station ID number. For example, to call Station ID number 123, dial *123.
Note
To use the EOW function, all OS-10 nodes in the subnetwork must be equipped with the factory-installed AUX board option. The nodes must also be configured with a unique station ID number for each node.
Engineering Orderwire (EOW) 51
OnSite Series Getting Started Guide 4 • System Management Access
At this point, the called station begins to ring if another telephone set is connected to the EOW port of that station.
Note
To call and communicate with all EOW stations at once (party-line function), dial *000.
To complete the call, simply place the telephone set in the on-hook position, like a regular analog phone.
Engineering Orderwire (EOW) 52
Chapter 5 Contacting Patton for assistance
Chapter contents
Introduction..........................................................................................................................................................54
Contact information..............................................................................................................................................54
Warranty Service and Returned Merchandise Authorizations (RMAs)...................................................................54
Warranty coverage ..........................................................................................................................................54
Out-of-warranty service .............................................................................................................................54
Returns for credit ......................................................................................................................................54
Return for credit policy .............................................................................................................................55
RMA numbers ................................................................................................................................................55
Shipping instructions ................................................................................................................................55
53
OnSite Series Getting Started Guide 5 • Contacting Patton for assistance
Introduction
This chapter contains the following information:
“Contact information”—describes how to contact Patton technical support for assistance.
“Warranty Service and Returned Merchandise Authorizations (RMAs)”—contains information about the
RAS warranty and obtaining a return merchandise authorization (RMA).
Contact information
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
Online support—available at www.patton.com.
E-mail support—e-mail sent to support@patton.com will be answered within 1 business day
Telephone support—standard telephone support is available Monday through Friday, from 8:00 A.M. to
5:00 P.M. EST (8:00 to 17:00 UTC-5), Monday through Friday by calling +1 (301) 975-1007
Warranty Service and Returned Merchandise Authorizations (RMAs)
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship­ment. All of our products are backed by a comprehensive warranty program.
Note
Warranty coverage
Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod­uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work­manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Out-of-warranty service
Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or elephants may require replacement.
Returns for credit
Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
If you purchased your equipment from a Patton Electronics reseller, ask your reseller how you should proceed with warranty service. It is often more convenient for you to work with your local reseller to obtain a replacement. Patton services our products no matter how you acquired them.
Introduction 54
OnSite Series Getting Started Guide 5 • Contacting Patton for assistance
Return for credit policy
Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
30 to 120 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase
price).
Over 120 days: Products will be accepted for repairs only.
RMA numbers
RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
Completing a request on the RMA Request page in the Support section at www.patton.com
By calling +1 (301) 975-1000 and speaking to a Technical Support Engineer
By sending an e-mail to returns@patton.com
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions
The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton Electronics Company
RMA#: xxxx 7622 Rickenbacker Dr. Gaithersburg, MD 20879-4773 USA
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 55
Appendix A Compliance information
Chapter contents
Compliance ...........................................................................................................................................................57
EMC ...............................................................................................................................................................57
Low-Voltage Directive (Safety) .......................................................................................................................57
PSTN .............................................................................................................................................................57
Declaration of Conformity....................................................................................................................................57
Authorized European Representative.....................................................................................................................57
56
OnSite Series Getting Started Guide A • Compliance information
Compliance
EMC
EN 55022 Class A
EN55024
Low-Voltage Directive (Safety)
IEC/EN60950-1
PSTN
This device is not intended nor approved for connection to the PSTN.
Declaration of Conformity
Patton Electronics, Inc declares that this device is in compliance with the essential requirements and other rel­evant provisions of Directive 2004/108/EC relating to electromagnetic compatibility and Directive 2006/95/EC relating to electrical equipment designed for use within certain voltage limits. The Declaration of Conformity may be obtained from Patton Electronics, Inc at www.patton.com/certifications.
The safety advice in the documentation accompanying this device shall be obeyed. The conformity to the above directive is indicated by CE mark on the device.
Authorized European Representative
D R M Green
European Compliance Services Limited.
Avalon House, Marcham Road
Abingdon,
Oxon OX14 1UD, UK
Compliance 57
Appendix B Specifications
Chapter contents
Model OS1052......................................................................................................................................................59
Trunk Interfaces .............................................................................................................................................59
Client Interfaces ..............................................................................................................................................59
Expansion Modules .........................................................................................................................................59
Configuration & Port Capacity for 2 Expansion Slots .....................................................................................59
Protection .......................................................................................................................................................59
Bandwidth Connectivity and Provisioning ......................................................................................................59
Timing & Synchronization .............................................................................................................................59
System Access .................................................................................................................................................59
Operations ......................................................................................................................................................60
Management ...................................................................................................................................................60
Packet Intelligence ..........................................................................................................................................60
Dimensions .....................................................................................................................................................60
Weight ............................................................................................................................................................60
Cooling ...........................................................................................................................................................60
Mounting .......................................................................................................................................................60
Power ..............................................................................................................................................................60
Environment ...................................................................................................................................................60
Model OS1063......................................................................................................................................................61
Trunk Interfaces .............................................................................................................................................61
Client Interfaces ..............................................................................................................................................61
Expansion Modules .........................................................................................................................................61
Configuration & Port Capacity for 2 Expansion Slots .....................................................................................61
Protection .......................................................................................................................................................61
Bandwidth Connectivity and Provisioning ......................................................................................................61
Timing & Synchronization .............................................................................................................................61
System Access .................................................................................................................................................61
Operations ......................................................................................................................................................62
Management ...................................................................................................................................................62
Packet Intelligence ..........................................................................................................................................62
Dimensions .....................................................................................................................................................62
Weight ............................................................................................................................................................62
Cooling ...........................................................................................................................................................62
Mounting .......................................................................................................................................................62
Power ..............................................................................................................................................................62
Environment ...................................................................................................................................................62
58
OnSite Series Getting Started Guide B • Specifications
Model OS1052
Trunk Interfaces
STM-1: G.707, G.783 Optics: G.957 S-1.1, L-1.1 and L-1.2 options
Client Interfaces
E1: G.703, 75-ohm and 120-ohm options T1: G.703, 100-ohm Ethernet 10/100Base-TX: 802.3u
Expansion Modules
SDH: STM-1 optical (2 ports) • STM-1 electrical (2 ports) PDH: E1 (21 ports) • E3/DS3 (3 ports) Packet Data: 10/100Base-TX (8 ports)
Configuration & Port Capacity for 2 Expansion Slots
STM-1: Base: 2 • Max: 6 E1: Base: 8 • Max: 50 E3/DS3: Base: – • Max: 6 10/100Base-TX: Base: 2 • Max: 18
Protection
Linear MSP 1+1 • SNCP/I and SNCP/N
Bandwidth Connectivity and Provisioning
Connectivity: VC-12, VC-3 levels One-way, two-way, drop-and-continue and multicast connections VCAT: VC-12-Xv and VC-3-Xv LCAS: G.7042 Packet encapsulation: GFP-F (G.7041)
Timing & Synchronization
Internal: Stratum 3 clock Line timing: STM-1 and E1/T1 External timing: Dual Sync In/Out ports at 2 or 1.5 Mbps/MHz SSM support: G.781
System Access
Serial RS-232 and Ethernet LAN management ports IP over DCCr and DCCm options IP over E1 signal mapped into selected VC-12 channel DCC transparency (any subset of DCC rows) Telnet
Model OS1052 59
OnSite Series Getting Started Guide B • Specifications
Operations
Local and remote software download and upgrade (FTP/TFTP) Loopbacks: facility and terminal ALS (automatic laser shutdown): G.958 Alarm Contacts (optional) Orderwire: 2-wire interface using E1 or E2 byte (optional)
Management
Web-based GUI management interface XML SNMP v1/v2
Packet Intelligence
Ethernet MAC: 802.3 VLAN: 802.1Q and Q-in-Q Service provider VLAN (SP-VLAN) using S-Tag: 802.1ad Tagging operations: C-Tag and S-Tag add/strip Flow Control: 802.3x Rate Limiting: Sustained and peak rates with 64 kbit/s granularity for ports and VLANs QoS: 4 levels with strict priority, WFQ and WRED support
Dimensions
1.75H x 17.25W x 11.54D in. (44.45H x 438.2W x 293D mm) 1RU
Weight
11 lbs (5 kg)
Cooling
Natural convection cooling (no fans)
Mounting
19-inch EIA/TIA or ETSI 300 mm racks, or desktop and wall-mounting options
Power
AC input: 100 to 245 V at 50 to 60 Hz DC input: -36 to -72 V (-48V nominal), dual inputs Consumption: 60 W maximum
Environment
Temperature: 0 to +50°C (+32 to +122°F) Humidity: 5 to 95%, non-condensing
Model OS1052 60
OnSite Series Getting Started Guide B • Specifications
Model OS1063
Trunk Interfaces
STM-1: G.707, G.783 Optics: G.957 S-1.1, L-1.1 and L-1.2 options
Client Interfaces
E1: G.703, 75-ohm and 120-ohm options T1: G.703, 100-ohm Ethernet 10/100Base-TX: 802.3u
Expansion Modules
SDH: STM-1 optical (2 ports) • STM-1 electrical (2 ports) PDH: E1 (21 ports) • E3/DS3 (3 ports) Packet Data: 10/100Base-TX (8 ports)
Configuration & Port Capacity for 2 Expansion Slots
STM-1: Base: 2 • Max: 6 E1: Base: 21 • Max: 63 E3/DS3: Base: – • Max: 6 10/100Base-TX: Base: – • Max: 18
Protection
Linear MSP 1+1 • SNCP/I and SNCP/N
Bandwidth Connectivity and Provisioning
Connectivity: VC-12, VC-3 levels One-way, two-way, drop-and-continue and multicast connections VCAT: VC-12-Xv and VC-3-Xv LCAS: G.7042 Packet encapsulation: GFP-F (G.7041)
Timing & Synchronization
Internal: Stratum 3 clock Line timing: STM-1 and E1/T1 External timing: Dual Sync In/Out ports at 2 or 1.5 Mbps/MHz SSM support: G.781
System Access
Serial RS-232 and Ethernet LAN management ports IP over DCCr and DCCm options IP over E1 signal mapped into selected VC-12 channel DCC transparency (any subset of DCC rows) Telnet
Model OS1063 61
OnSite Series Getting Started Guide B • Specifications
Operations
Local and remote software download and upgrade (FTP/TFTP) Loopbacks: facility and terminal ALS (automatic laser shutdown): G.958 Alarm Contacts (optional) Orderwire: 2-wire interface using E1 or E2 byte (optional)
Management
Web-based GUI management interface XML SNMP v1/v2
Packet Intelligence
Ethernet MAC: 802.3 VLAN: 802.1Q and Q-in-Q Service provider VLAN (SP-VLAN) using S-Tag: 802.1ad Tagging operations: C-Tag and S-Tag add/strip Flow Control: 802.3x Rate Limiting: Sustained and peak rates with 64 kbit/s granularity for ports and VLANs QoS: 4 levels with strict priority, WFQ and WRED support
Dimensions
1.75H x 17.25W x 11.54D in. (44.45H x 438.2W x 293D mm) 1RU
Weight
11 lbs (5 kg)
Cooling
Natural convection cooling (no fans)
Mounting
19-inch EIA/TIA or ETSI 300 mm racks, or desktop and wall-mounting options
Power
AC input: 100 to 245 V at 50 to 60 Hz DC input: -36 to -72 V (-48V nominal), dual inputs Consumption: 60 W maximum
Environment
Temperature: 0 to +50°C (+32 to +122°F) Humidity: 5 to 95%, non-condensing
Model OS1063 62
Appendix C Terms and Acronyms
Chapter contents
Abbreviations ........................................................................................................................................................64
63
OnSite Series Getting Started Guide C • Terms and Acronyms
Abbreviations
Abbreviation Meaning
A
AIS Alarm Indication Signal AMI Alternate Mark Inversion AU Administrative Unit AUX Auxiliary (port)
B
BIP Bit Interleaved Parity BBE Background Block Error BER Bit Error Rate BPV Bipolar Violation B3ZS Bipolar with 3-zero Substitution B8ZS Bipolar with 8-zero Substitution
C
cHEC core Header Error Check CLI Command Line Interface CSU/DSU Channel Service Unit/Data Service Unit C-Tag Customer-assigned tag (for example, VLAN tag)
D
DNU Do Not Use (for synchronization)
E
E1 European digital signal hierarchy level 1 EB Errored Block EDC Error Detection Code EIA Electronics Industries Alliance EOW Engineering Orderwire ES Errored Second ETSI European Telecommunications Standards Institute EXM Extension Header Mismatch EXZ Excessive Zeros
G
GFP Generic Framing Procedure
H
HDB3 High-Density Bipolar with 3-zero Substitution HP High-order Path HTTP Hyper Text Transfer Protocol
I
IP Internet Protocol
Abbreviations 64
OnSite Series Getting Started Guide C • Terms and Acronyms
Abbreviation Meaning
L
LCAS Link Capacity Adjustment Scheme LFD Loss of Frame Delineation LOF Loss of Frame LOP Loss of Pointer LP Low-order Path
M
MS Multiplex Section
N
NEBS Network Equipment Building System NEC National Electric Code
P
PBX Private Branch Exchange PC Personal Computer PDH Plesiochronous Digital Hierarchy PJC Pointer Justification Count PM Performance Monitoring POST Power-On Self-Test ppm parts per million PRC Primary Reference Clock PRI Primary Rate Interface PSC Protection Switching Count PSD Protection Switching Duration
R
RS Regenerator Section RSOH Regenerator Section Overhead RU Rack Unit (1.75 inches)
S
SD Signal Degrade SDH Synchronous Digital Hierarchy SEC Secondary source (also Synchronous Equipment Clock) SES Severely Errored Second SF Signal Failure SNMP Simple Network Management Protocol SOH Section Overhead SSM Synchronization Status Messaging SSU Synchronization Supply Unit S-Tag Service provider tag STM-1 Synchronous Transport Module level 1
Abbreviations 65
OnSite Series Getting Started Guide C • Terms and Acronyms
Abbreviation Meaning
T
TDM Time Division Multiplexing TIA Telecommunications Industry Association TIM Trace Identifier Mismatch TNV Telecommunications Network Voltage TP Termination Point TU Tributary Unit TUG Tributary Unit Group
U
UAS Unavailable Seconds
Abbreviations 66
Loading...