07MD2616RC-DS3
Streamline, optimize, and save!
Patton is a registered trademark and IPLink is a trademark of Patton Electronics Company in the
United States and other countries.
Specifications
• Any-to-any DS0 cross-connection & concentration
• Non-blocking ingress & egress aggregation
• Redundant failover
nxT1/E1 connections
from multiple sources
DS0s groomed over
user-defined egress
T1/E1
T1/E1
Model 6676
Using the flexible 2616RC’s DS0 switching
matrix, Service Providers can easily consolidate, manage, and provision up to 96 T1/E1
links from a single 6476 (4U) chassis. Uplink
access costs are significantly reduced by
grooming and aggregating DS0 traffic from
many partially used T1/E1 lines into selected
outgoing T1/E1 or STM-1 links.
Here is how it works:
Each 2616RC comes with 16 T1/E1 ports;
you select which timeslots connect to
downstream or upstream lines.
Based on customer requirements, assign
nx64 kbps timeslots to downstream
T1/E1 links, i.e 256 kbps (4 DS0s), 512
kbps (8 DS0s), 1024 kbps (16 DS0s), etc.
Use the 2616RC GUI to map DS0s from
downstream to upstream lines.
For example:
• 4 DS0s from port 1
• 8 DS0s from port 2
• 16 DS0s from port 3
• 3 DS0s from port 4
• All mapped to upstream E1
port 5 (31 DS0s).
16 configurable WAN ports: T1 (AMI/B8ZS line coding) or
E1 (HDB3/AMI line coding), G.703, G.704, G.723
10/100BaseT (RJ-45 connector); auto-negotiating; half or
full duplex operation for management
Internal or Network (from T1/E1 WAN port)
Indicators LEDs for power, CPU, system, Ethernet, External
clock, Test mode, and WAN ports frame and error status
HTTP, SNMP, Telnet Ethernet, RS-232 Console Port, SYSLOG Client, Software upgrade via FTP
Configurable alarms; Remote SNMP Traps; Front Panel LEDs
Master and slave clocking sources are user-selectable and
can be derived from other system cards in the chassis
Redundant, high speed, packet switched bus (PSB) and
TDM bus supporting 4096 DS0s
Safety: UL/CSA per UL1950 Canadian per CS-03. RTTE
Directive 99/5/EC, Environment FCC Part 15,CE Mark,
CTR12, CTR13, FCC Part 68
Operating temperature: 0–40°C (32–104 °F)
Humidity: 5–90% non-condensing
Front blade:0.75 H x 10.5 W x 6.3 D in.
(1.9 H x 26.7 W x 16.0 D cm)
Rear blade: 0.75 H x 10.5 W x 3.15 D in.
(1.9 H x 26.7 W x 8.0 D cm)
WAN Ports
Ethernet Ports
WAN Clocking
Front Panel Indicators
Management Services
Alarm Reporting
System Clocking
High Speed Midplane
Compliance
Environment
Dimensions
Patton-Inalp Networks AG
Meriedweg 7
CH-3172 Niederwangen
Switzerland
Phone
++4411 ((3311)) 998855 2255 2255
Fax
++4411 ((3311)) 998855 2255 2266
E-mail
ssaalleess@@iinnaallpp..ccoomm
Web
wwwwww..iinnaallpp..ccoomm
Patton Electronics Co.
7622 Rickenbacker Drive
Gaithersburg, Maryland 20879
USA
Phone
++11 330011 997755 11000000
Fax
++1
1 330011 886699 99229933
E-mail
ssaalleess@@ppaattttoonn..ccoomm
Web
wwwwww..ppaa ttttoonn..ccoomm
PE-Inalp Networks Private Ltd
Old No. 14 and New No.6,
Brahadambal Road,
Nungambakkam High Road
Chennai: 600 034, India
Phone
++9911 44 44 4455449900339955// 66 //77
Fax
++9911 44 44 44554499.. 00 339944
Email
ssaallee ss @@p
paattttoo nn..ccoo ..ii nn
Web
wwww ww ..ppaattttoo nn..ccoo ..iinn
An Associate of
Electronics Co., USA