Patton electronics 570-R8, 570-R16, 580-R8, 580-R16 User Manual

USER MANUAL
MODEL 570-R8/570-R16
580-R8/580-R16
100Base-T (CAT-5) Surge Protectors
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com
Part #07M570/580RC-A Doc# 074101UA Revised 2/13/97
CERTIFIED
An ISO-9001
Certified Company
2
2.0 GENERAL INFORMATION
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Customer Service at (301) 975-1007.
2.1 FEATURES
• Optional 8 or 16 port surge protection
• Multi-level surge protection
• Operation at Speeds up to 100 Mbps
• Optional 2, 4, 6 or 8 wire versions
• EIA/TIA TSB-40A Category 5 Compliant
• N.E.X.T. better than -40 dB at 100 MHz
• Shunts surges directly to chassis ground
• Easy to install
• Made in the U.S. A.
2.2 DESCRIPTION
The Patton Model 570 and 580 Rack Mount Series Surge Protectors provide effective surge protection for devices operating in
Category-5 Cabling Systems. The Model 570-Rx is specifically designed for point-of-use installation; the Model 580-Rx is designed to be installed at the building entrance. Both models use a multi-stage Silicon Avalanche Diode circuit, and will continue functioning while handling the appropriate IEC 801.5 surges applicable to their use (see the tables in Appendix B). Both the 570-Rx and 580-Rx will additionally protect against surges up to and exceeding 2kV/1kA in fail­safe mode.
Model’s 570-Rx and 580-Rx support a wide range of balanced interfaces from RS-422 to 100Base-T4. Highlights include a low insertion loss (less than 0.4dB at 100MHz) and minimal near end cross talk (better than -40 dB at all frequencies up to 100 MHz). Grounding is accomplished via a braided ground strap that provides a separate unit­rack connection. The customer is responsible for ensuring a proper rack to earth ground connection. For proper grounding, the resistance from the supplied ground lug to the rack frame ground should be less than 2.5 milliohms. Contact Technical Support if further details are needed for this measurement.
Warning:
This product will not provide complete protection should your
equipment or building be subject to a direct lightning hit.
1.0 WARRANTY INFORMATION
Patton Electronics warrants all Model 570/580 Rack Mount components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
1.1 SERVICE
All warranty and nonwarranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service: (301) 975-1007; http://www.patton.com; or
support@patton.com.
Note: Packages received without an RMA number will not be
accepted.
Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 570/580-Rx. Technical Service hours: 8AM to 5PM EST,
Monday through Friday.
1.2 CE NOTICE
The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support.
1
3.0 INSTALLATION
Model’s 570-Rx and 580-Rx surge protectors are easy to install and are designed to operate transparently to your network. This section describes connection procedures for both models.
3.1 PRODUCT APPLICATIONS
Both Model’s 570/580-Rx protect all eight pins on a modular RJ-45 Cat-5 interface, and work in environments with data rates up to 100 Mbps. The following descriptions will give you a general guideline for installing the units in your Cat-5 environment.
3.1.1 Point-Of-Use Applications Model 570-Rx)
The Model 570-Rx is designed for 100MHz point-of-use installations that use networking standards such as 100BaseT, RS-422 or 100VG-AnyLAN. Typical installations are shown in Figures 1 and 2, below. For best results the Model 570-Rx should be connected as close as possible to the communication port of the device to be protected .
3.1.2 Barrier Applications (MODEL 580-Rx)
The Model 580-Rx is a more robust protector than the Model 570­Rx, and is designed for use as a barrier protector on LAN equipment in campus networks. Applications include cable runs between buildings, cable runs between floors on multi-story structures, and as a higher capacity replacement for the Model 570-Rx.
The Model 580-Rx is also well suited for use in severe lightning areas, heavy industrial environments, and situations where heavy machinery is in the direct vicinity of sensitive LAN equipment and cabling. Figure 3 below shows a typical application for the Model 580-Rx. For best results, the braided grounding strap(s) on the rack should be attached to the grounded metal frame of the rack structure.
3.2 INSTALLATION PROCEDURES
In order to operate as designed, the Model 570-Rx and 580-Rx
must be connected correctly
to your Cat-5 network. Please read all the
instructions below and follow them carefully.
3.2.1 Connecting the Model 570-Rx or 580-Rx to an I/O Port
1. Turn off equipment power and unplug (disconnect) the existing connection between the UTP cable and the equipment’s I/O port.
3
Figure 2. Model 570-Rx in a Typical 100Base-T Point of Use Application
4
Workstation
Workstation
Workstation
Model 570/580-RX
Scale
Conveyor
Time Clock
Controller
Workstation
Model 570’s or 580’s
Model 570’s or 580’s
Model 570’s or 580’s
Local Hub
Model 570 or 580
Model 580-Rx
Ground Connection
To Other Building or Wall
Exterior Wall
Electrical Panel
Figure 3. Barrier Application for 580-Rx
Figure 1. Model 570-Rx in a Typical RS-422 Point of Use Application
2. Install the surge protector between the incoming UTP line and the protected equipment (see Figure 4, below). This installation requires a straight through Cat-5 patch cable with modular RJ-45 male connectors .
Note: It doesn’t matter which port the UTP cable plugs into on the rack, as long as the input is directly above or below the corresponding output.
3. Connect the ground braid(s) to the rack frame as illustrated in Figure 5.
4. Connect the rack structure frame directly to earth ground if it is not already connected. The best way to make this ground connection is to attach a thick braided metal strap to earth ground, a metal panel, a wall plate screw or an electrical panel or subpanel, using a hex nut or ground screw. Read the Caution and Important Note paragraphs below very carefully. If you cannot locate a nearby electrical ground, contact Patton Electronics Technical Service at:
(301) 975-1007; http://www.patton.com; or support@patton.com.
Caution: Surge energy may run both directions on the ground
strap. To provide the best protection, it is essential that the supplied ground strap on the Model 570/580-Rx is connected to the rack frame structure and that the rack frame structure is directly connected to earth ground. Do not lengthen the ground strap or connect to an earth ground other than the chassis ground unless instructed to do so by Patton Technical Support.
Important Note: The rack structure must have a direct connection to
earth ground. Proper connection of the frame to earth ground should not exceed 2.5 milliohms of resistance.
65
Cat. 5 input from network
Cat. 5 patch cable to protected equipment
Use Straight through cable with the shortest length possible for patch cable
Figure 5. Ground Braid Connection Instructions
Front Panel
Frame Structure
Lock Washer
GROUND BRAID
Star Washer
Nut
Ground Lug
Screw
Plastic Washer
Figure 4 Installation of Model 570-Rx/580-Rx Surge Protectors.
APPENDIX B
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC)
COMPLIANCE
Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)
Effective January 1996 the European Economic Community will
require that all electronic devices be tested and comply with all applicable International standards relating to the product type and category of use. Electromagetic Compatibility Directive 89/336/EEC specifically addresses communication line surge protection devices, since conformity to immunity standard EN50082-1:1992 is mandatory. The EN50082-1:10992 standard incorporates International Organization for Standardization (ISO) publications 801.2 and 801.4, which describe Electrostatic Discharge and Electrical Fast Transient requirements. ISO 801.5 describes Surge Immunity Requirements and is expected to be adopted as a mandatory requirement under EN50082-1 by the Technical Committee. in 1996. Any protector sold into the international community must meet these standards. This device has been tested* and found to comply with these standards as evidenced by its CE mark.
*Note: All test results are for the Model 570-Rx/580-Rx
alone
, not including
any external patch cables that are connected to the unit.
APPENDIX A
PATTON MODEL 578R8/588 SPECIFICATIONS
Environment: Category-5 Interfaces that utilize the RJ-45
connector, including RS-422, 423, 10Base­T, Token Ring, Fast Ethernet, 100Base-T, 100Base-T4 and ATM
Connectors: RJ-45 Female Response Time: Clamped to 13V after 0.1µS Characteristic 100 Ohms Impedance: NEXT Loss
(worst pair): Better than -40 dB at 100 MHz
Surge Clamping Model 570-Rx: 13 V max with 1 KV
Voltages Input; Model 580-Rx: 15 V max with 2 KV
Input
Surge Rating: IEC 801.5 Standard Level DC Clamping
Voltages: Common Mode to Gnd, 7.5 V (each line)
@ 50 mA; Differential mode, 8.1 V (per pair) @ 50 mA
Insertion Loss: Less than 0.4 dB (including connector) at all
frequencies
Return Loss: Better than 14 dB on both models Group Delay: None, 1 MHz to 100 MHZ Series Resistance: Less than 400 milliohms Grounding: External ground strap provides separate
unit-ground to chassis-ground contact
PC Board Dimensions: 7.0” x 3.0” Actual Panel Dimensions: 3.47” x 19.0” x 1.1” Standard Temperatures: 0 - 50
0
C/32 - 1220F
Flame Retardance: Plastic cases meet UL 94-V0 standard
7 8
Class
1 1.0 kV
24 A
2 1.0 kV
24 A
3 2.0 kV
48 A
4 (n/a)
(n/a)
5 4.0 Kv
95 A
Wave (1.2 x 50 µs)
Forms (1.2 x 50 µs)
IEC 801-5 Threat Levels as a Function of Class
Sym. Lines Coupling Mode
Line-GND, Zs=42 Ohms
Figure B-1. IEC Threat Levels as a Function of Class.
APPENDIX C (continued)
TSB-40A COMPLIANCE TESTING RESULTS
TYPICAL ATTENUATION MEASUREMENT
APPENDIX C
EIA/TIA TSB-40A COMPLIANCE
The Model 570-Rx/580-Rx series surge protectors have been designed to conform to stringent EIA/TIA TSB-40 standards as required for all Category-5 connecting hardware. These standards specify the capacitance and near end cross-talk (N.E.X.T) to insure proper operation of ALL connected equipment. Specific test results are shown in the tables on the following pages*.
TSB-40A COMPLIANCE TESTING RESULTS
TYPICAL NEAR-END CROSSTALK MEASUREMENT
*Note: All test results are for the Model 570-Rx/580-Rx
alone
, not including
any external patch cables that are connected to the unit.
9 10
SOURCE/VICTIM PAIRS
FREQ. 1-2/3-6 1-2/4-5 1-2/7-8 3-6/4-5 3-6/7-8 4-5/7-8 SPEC MHz dB dB dB dB dB dB dB
1 82.0 85.0 85.0 78.0 84.0 82.0 >65 4 74.0 77.0 85.0 68.0 73.0 71.0 >65
8 69.0 71.0 83.0 62.8 67.0 64.0 62 10 67.0 69.0 83.0 61.0 66.0 63.0 60 16 63.0 66.0 79.0 56.0 61.0 59.0 56 20 65.5 64.0 78.0 57.0 66.0 56.0 54 25 62.0 62.0 77.0 53.0 58.0 56.0 52
31.25 56.1 62.0 75.5 52.0 54.6 53.0 50
62.5 46.0 56.0 74.0 44.5 46.0 47.0 44
100 45.0 48.0 57.0 40.5 42.0 49.0 40
Figure C-1. N.E.X.T. measurements for Patton Model 570-Rx
SOURCE/VICTIM PAIRS
FREQ. 1-2/3-6 1-2/4-5 1-2/7-8 3-6/4-5 3-6/7-8 4-5/7-8 SPEC MHz dB dB dB dB dB dB dB
1 77.0 85.0 85.0 79.0 83.0 81.0 >65
4 70.0 76.0 85.0 68.0 73.0 70.0 >65
8 67.0 70.0 85.0 62.1 67.0 64.0 62
10 67.0 68.0 85.0 61.0 66.0 62.0 60 16 62.0 65.0 83.0 57.0 61.0 58.0 56 20 69.0 65.0 73.0 58.0 63.0 56.0 54 25 59.0 62.0 72.0 53.2 58.0 55.0 52
31.25 57.0 61.0 81.0 51.0 55.0 53.0 50
62.5 51.5 57.0 68.0 45.0 46.0 48.0 44
100 44.0 45.0 54.0 42.0 41.4 49.0 40
Figure C-2. N.E.X.T. measurements for Patton Model 580-Rx
Freq. Pins: 1-2 Pins: 3-6 Pins: 4-5 Pins:7-8 Spec MHz dB dB dB dB dB
1 0.0 0.0 0.0 0.1 0.1 4 0.1 0.1 0.1 0.0 0.1
8 0.0 0.1 0.1 0.1 0.1 10 0.0 0.0 0.1 0.0 0.1 16 0.1 0.1 0.1 0.0 0.2 20 0.1 0.1 0.2 0.0 0.2 25 0.0 0.0 0.1 0.0 0.2
35.25 0.0 0.1 0.2 0.0 0.2
62.5 0.2 0.1 0.3 0.0 0.3
100 0.4 0.3 0.4 0.3 0.4
Figure C-3. Attenuation measurements for Patton Model 570-Rx
Freq. Pins: 1-2 Pins: 3-6 Pins: 4-5 Pins:7-8 Spec MHz dB dB dB dB dB
1 0.1 0.0 0.1 0.1 0.1
4 0.1 0.1 0.0 0.1 0.1
8 0.0 0.1 0.0 0.1 0.1 10 0.1 0.1 0.1 0.1 0.1 16 0.1 0.1 0.1 0.1 0.2 20 0.1 0.2 0.0 0.2 0.2 25 0.0 0.1 0.1 0.1 0.2
35.25 0.0 0.1 0.0 0.1 0.2
62.5 0.1 0.2 0.1 0.2 0.3
100 0.4 0.3 0.4 0.3 0.4
Figure C-4. Attenuation measurements for Patton Model 580-Rx
Appendix C (continued)
TSB-40A Compliance Testing Results
TYPICAL INSERTION LOSS MEASUREMENT
Copyright ©
Patton Electronics Company
All Rights Reserved
APPENDIX C (continued)
TSB-40A COMPLIANCE TESTING RESULTS
TYPICAL RETURN LOSS MEASUREMENT
11
Figure C-5. Return Loss measurements for Patton Model 570-Rx
Figure C-6. Return Loss measurements for Patton Model 580-Rx
12
Freq. Pins: 1-2 Pins: 3-6 Pins: 4-5 Pins:7-8 Spec MHz dB dB dB dB dB
1 34.0 28.0 28.0 29.0 23 4 38.0 38.0 45.0 43.8 23
8 39.0 41.0 42.0 42.0 23 10 38.0 41.0 39.0 39.5 23 16 34.0 35.0 33.0 33.0 23 20 33.7 33.0 31.0 31.6 23 25 31.0 30.0 34.0 30.0 14
31.25 28.1 27.0 28.0 27.8 14
62.5 21.0 22.0 22.0 22.0 14
100 17.0 21.0 18.2 17.8 14
Freq. Pins: 1-2 Pins: 3-6 Pins: 4-5 Pins:7-8 Spec MHz dB dB dB dB dB
1 28.0 28.0 29.0 30.0 23 4 38.0 38.4 47.0 44.5 23
8 39.0 43.8 41.0 41.2 23 10 38.0 44.0 38.0 38.7 23 16 35.0 38.0 30.0 33.4 23 20 33.0 34.0 31.0 31.0 23 25 31.0 31.0 29.0 28.3 14
31.25 29.0 28.0 27.0 28.0 14
62.5 21.8 22.0 21.0 21.0 14
100 17.2 19.3 16.7 17.3 14
Pin Number: DC Resistance
Milliohms
1 180 2 190 3 180 4 190 5 180 6 120 7 190 8 180
Pin Number: DC Resistance
Milliohms
1 180 2 180 3 180 4 190 5 190 6 120 7 180 8 160
Figure C-7. Patton Model 570-Rx Insertion Loss Measurement
Figure C-8.Patton Model 580-Rx Insertion Loss Measurement