1.0 WARRANTY INFORMATION
Patton Electronics warrants all Model 3/11 and 3/45 components
to be free from defects, and will—at our option—repair or replace the
product should it fail within one year from the first date of shipment.
This warranty is limited to defects in workmanship or materials, and
does not cover customer damage, abuse or unauthorized modification.
If this product fails or does not perform as warranted, your sole
recourse shall be repair or replacement as described above. Under no
condition shall Patton Electronics be liable for any damages incurred
by the use of this product. These damages include, but are not limited
to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product.
Patton Electronics specifically disclaims all other warranties,
expressed or implied, and the installation or use of this product shall
be deemed an acceptance of these terms by the user.
CE NOTICE
The CE symbol on your Patton Electronics equipment indicates
that it is in compliance with the Electromagnetic Compatibility (EMC)
directive and the Low Voltage Directive (LVD) of the Union European
(EU). A Certificate of Compliance is available by contacting Technical
Support.
SERVICE
All warranty and non-warranty repairs must be returned freight
prepaid and insured to Patton Electronics. All returns must have a
Return Materials Authorization number on the outside of the shipping
container.This number may be obtained from Patton Electronics
Technical Support:
Tel: (301) 975-1007
Email: support@patton.com.
www: http://www.patton.com
Patton Electronics' technical staff is also available to answer any
questions that might arise concerning the installation or use of your
Model 3/11 or 3/45. Technical Service hours: 8AM to 5PM EST,
Monday through Friday.
1 2
PRODUCT DESCRIPTION
The Patton Model 3/11 and 3/45 Data Tap is a passive device
that allows a terminal device to non-intrusively monitor data activity on
a T1, E1 or DDS twisted-pair line. Two RJ-11 or RJ-45 modular jacks
labeled ‘LINE’ are wired in parallel to pass signals over the line. The
RJ-45 jack labeled ‘TAP’ is “tapped” through 470 ohm resistors on
each line for non-intrusive monitoring of the data line.
INSTALLATION
The 3/11 and 3/45 are passive devices which can be installed
and left on the line indefinitely. To install the unit,
1. Connect 3/11 or 3/45 in series with the T1, E1 or DDS line to
be monitored.
2. Connect the monitoring device to the TAP side of the 3/11 or
3/45.
NOTE: Packages received without an RMA number will not be
accepted.
TAP
LINE
LINE