Patton electronics 1082/I, 1082/144/I User Manual

USER MANUAL
MODEL 1082/I and 1082/144/I
iDSL Modem with 10Base- T Interface
Part# 07M1082/I-B Doc# 033181UB Revised 7/13/01
CERTIFIED
An ISO-9001
Certified
Company
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007
TABLE OF CONTENTS
1.0 Warranty Information .................................................................. 4
1.1 FCC Information ........................................................................... 4
1.2 CE Notice...................................................................................... 4
1.3 Service.......................................................................................... 5
2.0 General Information..................................................................... 6
2.1 Features........................................................................................ 6
2.2 Description.................................................................................... 7
2.3 1082 SNMP Management Solutions............................................. 7
HTTP/HTML Management ........................................................... 7
3.0 PPP Operational Background..................................................... 8
3.1 Applications .................................................................................. 8
4.0 Configuration ............................................................................. 11
4.1 Configuring the Hardware DIP Switches .................................... 11
Configuring DIP Switch S1 ......................................................... 12
Switches S1-1 and S1-2: Data Rate........................................... 13
Switch S1-5: Asynchronous/Sync Operation.............................. 13
Switches S1-6 and S1-7: System Clock Mode ........................... 14
Switch S1-8: Response to RDL Request.................................... 14
Configuring DIP switch “S2” ....................................................... 15
Switches S2-1: 19.2 kbps or 144* kbps
Synchronous Rate Enable.......................................................... 15
Switch S2-2: Front Panel Switch Disable ................................... 16
Switches S2-3, S2-6, S2-7 and S2-8: Reserved ........................ 16
5.0 Installation.................................................................................. 17
5.1 Connecting DSL Interface........................................................... 17
5.2 Connecting 10Base-T Ethernet Port to PC (DTE) ...................... 18
5.3 Connecting 10Base-T Ethernet Port to Hub (DCE) .................... 18
5.4 Power Connection ...................................................................... 19
Universal AC Power (100–240VAC)........................................... 19
DC Power ................................................................................... 20
6.0 Operation.................................................................................... 21
6.1 Power-up .................................................................................... 21
6.2 LED Status Monitors................................................................... 21
6.3 Test Modes ................................................................................. 23
Remote Digital Loopback (RDL)/V.52 (BER).............................. 23
A 1082/I Specifications ................................................................. 25
A.1 Transmission Format ...................................................................25
A.2 Transmission Line ........................................................................25
A.3 Clocking .......................................................................................25
A.4 Distance .......................................................................................25
A.5 Data Rates ...................................................................................25
A.6 Diagnostics ..................................................................................25
A.7 LED Status Indicators ..................................................................25
2
A.8 Connectors ..................................................................................25
A.9 Power ...........................................................................................25
A.10 Temperature Range .....................................................................26
A.11 Altitude .........................................................................................26
A.12 Humidity .......................................................................................26
A.13 Dimensions ..................................................................................26
A.14 Weight ..........................................................................................26
B Model 1082/I Factory Replacement Parts
and Accessories ........................................................................ 27
3
1.0 WARRANTY INFORMATION
Patton Electronics
warrants all Model 1082/I and Model 1082/144/I components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall
Patton Electronics
be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product.
Patton Electronics
spe­cifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
1.1 FCC INFORMATION
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer­ence when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
1.2 CE NOTICE
The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Patton Technical Support.
4
1.3 SERVICE
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materi­als Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at:
Tel:
(301) 975-1007
E-mail:
URL:
support@patton.com
www.patton.com
Note
Packages received without an RMA number will not be
accepted.
Patton Electronics’ technical staff is also available to answer any ques­tions that might arise concerning the installation or use of your Model 1082/I or Model 1082/144/I. Technical Service hours:
EST, Monday
through
Friday
.
8AM
to
5PM
5
2.0 GENERAL INFORMATION
Thank you for your purchase of this
Patton Electronics
product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact
Patton Electronics Technical Support
at
(301) 975-1007
.
2.1 FEATURES
• Provides MAC Level Data Link (Layer 2) connection between two
peered 10Base-T Ethernet LANs
• Operates transparently to higher level protocols such as TCP/IP, DEC-
net, NETBIOS and IPX
• PPP (Point to Point Protocol, RFC 1661) with Bridge Control Protocol
(RFC 1638)
• Automatically learns, loads and removes MAC addresses
• Point-to-point distances up to 5 miles (all data rates) on 24 AWG
twisted pair
• HTTP/SNMP Manageable as CP (Customer Premises) Unit with
1092ARC CO (Central Office) Rack Card and 1001MC management card
• Internal or receive recovered clocking between units
• LED indicators for 10Base-T Link, DSL Link, Status, No Signal, Error
and Test Mode
• Remote digital loopback, local line loopback diagnostic modes
• Synchronous data rates: 19.2, 32, 56, 64, 128, and 144 kbps
Note
144 kbps data rate is only available on the Model 1082/144/I.
19.2 kbps rate is available on all Model 1082 series modems
except
for the 1082/144/I.
• Full duplex operation over a single twisted pair (2-wires)
• Multi-Rate Symmetric DSL
• Compatible with the popular Patton Model 1092A
• Universal power supply (90–260VAC) or DC power supply (-48VDC)
• Small, Convienent Desktop Unit
• CE Marked
6
2.2 DESCRIPTION
The Model 1082/I and Model 1082/144/I are Multi Rate iDSL Modems that provide seamless MAC Layer connectivity between 2 peered 10Base-T LANs. Now, Enterprise users no longer need to hassle with a bridge and a CSU/DSU or recurring leased line costs. The 1082 allows users to add addi­tional nodes to a LAN that has reached its maximum distance limits or sepa­rate high traffic areas of a LAN. The 1082 connects peered LANs and automatically forwards and receives LAN broadcasts, multi-casts and frames across a 2-wire DSL span. The Model 1082/I and Model 1082/144/I support PPP (RFC 1s661) and BCP (RFC 1638).
Both 1082 modems’ features include loopback diagnostics, inband SNMP/HTTP remote management capabilities using NetLink Plug-and­Play and externally accessible configuration switches. As a symmetric DSL modem, the1082 offers the same data rates in both directions over a single pair of regular telephone lines using 2BIQ modulation. The 1082 connects to the DSL line via an RJ-45 jack, and is powered by a univer­sal (90–260VAC) supply or a DC supply (-48VDC).
2.3 1082 SNMP MANAGEMENT SOLUTIONS
The Model 1082/I and Model 1082/144/I are SNMP manageable when con­nected to a rack-mounted Model 1092ARC (see Figure 1). SNMP manage­ment is enabled through a 1001MC rack management card located in the Patton Electronics Rack System.
Model 1082
2B1Q
connections to
remote 1082s
Model 1082
Rack-mounted
1092ARCs
Management
Station
10Base-T connection to 1001MC
Figure 1.
Typical application
HTTP/HTML Management
The 1001MC maintains HTML pages that can be viewed through a Web browser. You can display remote statistics and configure Model 1082 parameters simply by entering the 1001MC’s IP address into the browser.
7
3.0 PPP OPERATIONAL BACKGROUND
PPP is a protocol used for multi-plexed transport over a point-to-point link. PPP operates on all full duplex media, and is a symmetric peer-to­peer protocol, which can be broken into three main components:
A standard method to encapsulate datagrams over serial links
A Link Control Protocol (LCP) to establish, congure, and test the
data-link connection
A family of Network Control Protocols (NCPs) to establish and cong­ure different network layer protocols
In order to establish communications over a point-to-point link, each end of the PPP link must rst announce its capabilities and agree on the parameters of the link’s operation. This exchange is facilitated through LCP Congure-Request packets.
Once the link has been established and optional facilities have been negotiated, PPP will attempt to establish a network protocol. PPP will use Network Control Protocol (NCP) to choose and congure one or more network layer protocols. Once each of the network layer protocols have been congured, datagrams from the established network layer protocol can be sent over the link. The link will remain congured for these communications until explicit LCP or NCP packets close the link down, or until some external event occurs.
The PPP Bridging Control Protocol (BCP), dened in RFC 1638, cong­ures and enables/disables the bridge protocol on both ends of the point­to-point link. BCP uses the same packet exchange mechanism as the Link Control Protocol (LCP). BCP is a Network Control Protocol of PPP, bridge packets may not be exchanged until PPP has reached the net­work layer protocol phase.
3.1 APPLICATIONS
In situations where a routed network requires connectivity to a remote Ether­net network, the interface on a router can be congured as a PPP IP Half Bridge. The serial line to the remote bridge functions as a Virtual Ethernet interface, effectively extending the routers serial port connection to the remote network. The bridge device sends bridge packets (BPDU’s) to the router's serial interface. The router will receive the layer three address infor­mation and will forward these packets based on its IP address.
8
Patton 1082/I Bridge
Ethernet LAN
Patton 1082/C connected to a router
PEC device with
serial interface
Figure 2.
Cisco router with serial interface, congured as PPP Half-Bridge
Figure 2 shows a typical Cisco router with a serial interface congured as a PPP Half Bridge. The router serial interface uses a remote device that supports PPP bridging to function as a node on the remote Ethernet network. The serial interface on the Cisco will have an IP address on the same Ethernet subnet as the bridge.
For example, the customer site is assigned the addresses 192.168.1.0/ 24 through 192.168.1.1/24. The address 192.168.1.1/24 is also the default gateway for the remote network. The above settings remove any routing/forwarding intelligence from the CPE. The associated Cisco con­guration will set serial interface (s0) to accommodate half bridging for the above example.
Authentication is optional under PPP. In a point-to-point leased-line link, incoming customer facilities are usually xed in nature, therefore authen­tication is generally not required. If the foreign device requires authenti­cation via PAP or CHAP, the PPP software will respond with default Peer­ID consisting of the units Ethernet MAC address and a password which consists of the units Ethernet MAC address.
Some networking systems do not dene network numbers in packets sent out over a network. If a packet does not have a specic destination network number, a router will assume that the packet is set up for the local segment and will not forward it to any other sub-network. However, in cases where two devices need to communicate over the wide-area, bridging can be used to transport non-routable protocols.
9