Patton electronic IAD 3086 User Manual

T
he Patton Model 3086 ipRocketLink IAD redefines access and sets the
new standard for customer premise equipment. Based on European Telecommunications Standardization Institute (ETSI) and International Telecommunications Union (ITU) G.SHDSL G.991.2 standard, the Patton 3086 ipRocketLink enables 2.3/4.6 Mbps speeds at nx64 (n=1..36/72) over a single pair of wires while combining standards-based transmission with Synchronous-Serial, Ethernet, and high speed IP routing…all in one compact package.
With Patton’s FlexIP™ architecture, the Model 3086 offers V.35, X.21, or T1/E1 Sync-Serial interfaces
and
10/100 Ethernet
ports. Integrated software selectable
DCE/DTE support eliminates messy
crossover cables. The Ethernet port
enables access to any IP network via ATM,
PPP, or Frame Relay. Both interfaces can
be simultaneously selected with user-
defined bandwidth for each port.
The 3086 boasts easy installation with DIP
switch, Telnet, and WWW/SNMP manage-
ment. It provides bridging and routing
functionality, along with advanced IP fea-
tures like NAT and Firewall, and optional
IPSec-based VPN. As part of Patton’s fam-
ily of ipDSL products, the Model 3086
offers a complete, managed, end-to-end
system when used with Patton’s central
site access concentrators.
Visit www.patton.com for more informa-
tion.
Deploy multiple managed services with the Model 3086 ipRocketLink over 2-wire standards-based G.SHDSL transmission.
G.SHDSL Integrated Access Device
Model 3086 ipRocketLink IAD
NetLink™ Access Products
Built-in Ethernet/IP Router Standard
With Patton’s FlexIP architecture, split the band­width and use both interfaces at the same time
Choice of V.35, X.21, or T1/E1
Get the right interface with the right connector and avoid messy adapter or crossover cables
Get ATM, PPP, and Frame Relay
Versatile interface options allow for simple deployment into any network environment
nx64 Speeds to 2.3/4.6 Mbps
User-selectable data rates for Sync-Serial, WAN, or Ethernet/IP ports. Use as a standalone or with the ForeFront Access system
Interoperable with Third-Party DSLAMs
Take advantage of Patton reliability whether you connect back-to-back or to a third-party DSLAM.
LEDs and Full V.52/V.54 Diagnostics
Easy-to-access toggle switches let you test the link with built-in test modes. LEDs provide clear status at-a-glance
Model 3086 ipRocketLink IAD
• Simultaneous use of serial and Ethernet interfaces
• Internal universal (90–260) AC or 48V DC power
• 13 LEDs show status at-a-glance
• Configure with console, Web, Telnet, or DIP-switches
• Built-in Ethernet MDI-X for easy connections to hubs and PCs
WWW/SNMP Manageable
Built-in VT-100 console port makes setup a snap, and you can use the embedded HTTP/SNMP agent to manage the Model 3086 from anywhere in the world.
Cisco
828
ZyXel
782
3086 Competitive Positioning
Line Type
ATM Encapsulation
Native PPP/Frame Relay
Bridging/PPPoE/IPoATM
NAT/MultiNAT/DHCP
Statefull Firewall/ACL
V.35/X.21/T1/E1
Status LEDS
ENET Cross-Over Switch
10/100 Ethernet
Built-In Web Mgmt
Tech Support
Software Upgrades
Compact Unit
Best Value
Connectivity
Ease of Use
G.SHDSL
Yes NO Yes Yes Yes NO
10 Yes NO NO
$$$ $$$
Large
$$$
G.SHDSL
YES NO Yes Yes Yes NO
6 NO Yes NO
included included
Large
$$$
Patton
3086
G.SHDSL
YES YES YES YES YES YES
12 YES YES YES
FREE FREE
Compact
YES
07MD3086-DS5
Patton is a registered trademark, and NetLink is a trademark of Patton Electronics Company in the United States and other countries.
Specifications
Why use our Model 3086?
The Patton Model 3086 ipRocketLink IAD delivers all the advanced features needed for secure, reliable, and high speed data connections. By combining serial access with Ethernet/IP, the 3086 IAD makes next-generation connectivity simple, easy, and cost effective.
Available with standard WAN and serial interface such as V.35, X.21, T1, and E1, the 3086 is a potent NTU for any network con­nection. In addition, the Model 3086 offers a standard 10/100 full-duplex Ethernet/IP interface with capabilities ready for any routing task. NAT, DHCP, Firewall, IDS, and Filtering give you complete control over network services and security. For ulti­mate flexibility the 3086 allows simultaneous operation of the serial and Ethernet ports.
The 3086 IAD can be used back-to-back or with the Patton ForeFront Access Infrastructure System. Additionally, the 3086 IAD can be used with any other G.SHDSL TDM or Packet sys­tem.
G.991.2 ITU G.SHDSL Annex A & Annex B, G.994.1 G.hs. nx64 data rates over 2-wire full-duplex to 2.3 Mbps, sym­metrical, TC-PAM encoding. Distances: 32,000 ft (9.8 km) at 192 kbps to 18,000 ft (5.6 km) at 2.312 Mbps.
Shielded RJ-11F isolation per IEC 950
10/100Base-T, auto-sensing, full/half-duplex operation, built-in MDI-X
V.35—M/34F, X.21—DB15F (DCE/DTE), T1—RJ48C, E1—RJ48C, and dual BNC
EIA-561 RJ-45 RS-232, VT-100 CLI, TELNET, Embedded WEB/HTTP, SNMP, Logging or SMTP on events: POST, POST errors, line/DSL, PPP/DHCP, IP MPOA AAL5 & bridged encapsulation RFC 2684 & RFC 1577 IPoATM. LLC/VC Mux support.
UNI 3.1, and 4.0 ATM QoS with UBR/CBR/nrt-VBR/rt­VBR and per-VC queuing and shaping. • Peak cell rate shaping on a per-VCC basis up to 32 active VCCs • I.610 OAM network management including AIS/RDI, loop-back and performance monitoring.
Frame Relay over DSL. Encapsulates IP traffic from Ethernet port into Frame Relay according to RFC-1490.
Enhanced ILMI 4.0 for auto-configuration of ATM PVCs, IP (RFC 741), TCP (RFC 793), UDP (RFC 768), ICMP (RFC 950), ARP (RFC 826). IP Router with RIP (RFC
1058), RIPv2 (RFC 2453), OSPF (RFC 2328) Integrated DHCP Server (RFC 2131). Selectable IP leases and MAC/IP pairings.
DHCP relay agent (RFC 2132/RFC 1542) with 8 address pools. DNS Relay. IGMP v1 and v2. IP-in-IP (RFC-2003) encapsulation, Ethernet Bridging.
NAT/NAPT with integrated application support, MultiNat with 1:1 mapping, Many:1, Many:Many mapping, NAT Port/IP redirection and mapping.
DoS Detection/protection. Intrusion detection, Logging of session, blocking and intrusion events and Real­Time alerts, Password protected system management with a username/password for console and virtual ter­minal, Packet filtering firewall for controlled access to and from LAN/WAN. Support for 255 rules in 32 filter sets. 16 individual connection profiles. Access list determining up to 5 hosts/networks which are allowed to access management system SNMP/HTTP/TELNET
12 LEDs: DSL Link; Sync Serial: TD, RD, CTS, DTR; LAN: TX, RX, 100M Link; Status: NS, ER, TM.
Internal universal 90–260 VAC input or 48 VDC input. Optional external power available.
FCC Part 15A, CE Mark, EMC Directive 89/336/EEC, Low-Voltage Directive 73/23/EEC, EN60950, EN55022 (CISPR 22)
Temperature: 32–122°F (0–50°C); Humidity: 5–90%, non-condensing
7.3 x 6.6 x 1.62 inch (185 x 168 x 41mm).
DDSSLL
DDSSLL CCoonnnneeccttiioonn
EEtthheerrnneett CCoonnnneeccttiioonn
SSeerriiaall IInntteerrffaaccee
MMaannaaggeemmeenntt
AATTMM SSuuppppoorrtt
FFrraammee RReellaayy ((KKeeyyeedd ffeeaattuurree))
PPrroottooccooll
PPrroottooccooll ((ccoonnttiinnuueedd))
SSeeccuurriittyy
IInnddiiccaattoorrss
PPoowweerr SSuuppppllyy
CCoommpplliiaannccee
EEnnvviirroonnmmeenntt
DDiimmeennssiioonnss
Patton-Inalp Networks AG
Meriedweg 7
CH-3172 Niederwangen
Switzerland
Phone
++4411 ((3311)) 998855 2255 2255
Fax
++4411 ((3311)) 998855 2255 2266
E-mail
ssaa lleess@@iinn aallpp ..ccoomm
Web
wwwwww..iinnaallpp..ccoomm
Patton Electronics Co.
7622 Rickenbacker Drive
Gaithersburg, Maryland 20879
USA
Phone
++11 330011 997755 11 000000
Fax
++1
1 330011 886699 99229933
E-mail
ssaa lleess@@ppaattttoonn..ccoomm
Web
wwwwww..ppaattttoonn..ccoomm
PE-Inalp Networks Private Ltd
Old No. 14 and New No.6,
Brahadambal Road,
Nungambakkam High Road
Chennai: 600 034, India
Phone
++ 9911 4444 44 5544 99 0033 9955 // 66 // 77
Fax
++ 9911 4444 44 5544 99 .. 0033 9944
Email
ss aa ll eess @@p
paa tttt oo nn .. ccoo .. ii nn
Web
wwww ww..pp aatt ttoo nn .. ccoo..iinn
An Associate of
Electronics Co., USA
Loading...