Patton electronic 581 User Manual

USER MANUAL
MODEL 571/581
100Base-T (CAT-5) Surge Protectors
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com
An ISO-9001
Certified Company
CERTIFIED
Part# 07M571/581-A Doc# 074300U Rev. B Revised 1/22/08
,
1.0 WARRANTY INFORMATION
Patton Electronics warrants all Model 571/581 components to be
free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
1.1 SERVICE
All warranty and nonwarranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Support: (301) 975-1007; http://www.patton.com; or,
support@patton.com.
Notice: Packages received without an RMA number will not be
accepted.
Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 571/581. Technical Service hours: 8AM to 5PM EST, Monday
through Friday.
112
2
2.0 GENERAL INFORMATION
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Customer Service at (301) 975-1007.
2.1 FEATURES
• Multi-level surge protection
• Operation at Speeds up to 100 Mbps
• Four-wire protection on lines 1, 2, 3, and 6 on Cat-5 RJ-45
• EIA/TIA TSB-40A Category 5 Compliant
• N.E.X.T. better than -43 dB at 100 MHz
• Shunts surges directly to chassis ground
• Easy to install
• Made in the U.S.A.
2.2 DESCRIPTION
Devices that connect to Category-5 cabling systems are routinely threatened by unwanted electrical energy (lightning, AC power induction, ESD and more). Higher speed devices–such as those operating at 100 Mbps–are especially vulnerable to the effects of these hazards, which can include data loss and hardware damage.
The Patton Model 571 and 581 Series Surge Protectors provide effective surge protection for devices operating in Category-5 Cabling Systems. The Model 571 is specifically designed for point-of-use installation; the Model 581 is designed to be installed at the building entrance. Both models use a multi-stage Silicon Avalanche Diode circuit, and will continue functioning while handling the appropriate IEC
801.5 surges applicable to their use (see the tables in Appendix B). Both the 571 and 581 will additionally protect against surges up to and exceeding 2kV/1kA in fail-safe mode.
Models 571 and 581 support a wide range of balanced interfaces running over 4 wires. Highlights include a low insertion loss (less than
0.4dB at 100MHz) and minimal near end cross talk (greater than -43 dB at all frequencies up to 100 MHz). Grounding is accomplished via an external ground strap that provides a separate unit-ground to chassis­ground connection.
Warning: This product will not provide complete protection should your equipment or building be subject to a direct lightning hit.
3
3.0 INSTALLATION
Patton's Model 571 and 581 surge protectors are easy to install and are designed to operate transparently to your network. This section describes connection procedures for both models.
3.1 PRODUCT APPLICATIONS
Both Models 571 and 581 protect 4 pins on the modular RJ-45 Cat­5 interface, and work in environments with data rates up to 100 Mbps. The following descriptions will give you a general guideline for installing the units in your Cat-5 environment.
3.1.1 POINT-OF-USE APPLICATION (MODEL 571)
The Model 571 is designed for installation on LAN equipment in a typical office environment (see Figure 1, below). For best results the Model 571 should be connected as close as possible to the communication port of the device to be protected . Also, the flat braided grounding wire on the Model 571 should be attached to the grounded metal frame of the device being protected.
Figure 1. A typical Point-of-Use Application for the Patton Model 571.
Model 571
Model 571
1 (TX +) 2 (TX -) 3 (RX+) 4 (N/C) 5 (N/C) 6 (RX-) 7 (N/C) 8 (N/C)
1 2 3 4 5 6 7 8
4
3.1.2 BARRIER APPLICATION (MODEL 581)
The Model 581 is a more robust protector than the Model 571, and is designed for use as a barrier protector on LAN equipment in campus networks. Applications include cable runs between buildings, cable runs between floors on multi-story structures, and as a higher capacity replacement for the Model 571.
The Model 581 is also well suited for use in severe lightning areas, heavy industrial environments, and installations with heavy machinery in the direct vicinity of sensitive LAN equipment and cabling. Figure 2 (above) shows a typical application for the Model 581. For best results, the braided grounding strap on the Model 581 should be attached to the grounded metal frame of the device being protected. When installation is made at a barrier, such as an external wall, the braided strap should be connected to a nearby electrical ground.
3.2 INSTALLATION PROCEDURES
In order to operate as designed, the Model 571 and 581 must be
connected correctly
to your Cat-5 network. Please read all the
instructions below and follow them carefully.
Connection of the Model 571 or 581 to an I/O Port
1. Turn off equipment power and unplug (disconnect) the existing connection between the UTP cable and the equipment’s I/O port.
Figure 2. A typical barrier application for the Patton Model 581.
Model 571 or 581
Model 571 or 581
Model 571 or 581
Local Hub
Model 581
Electrical Panel
Exterior Wall
To other bldg. or floor