5
INSTALLATION
The sections on the next page describe installing the following:
· Model 460
· Model 460-TBP
Refer to the appropriate section on the following page to install
your unit.
Installing the Model 460
Do the following:
1) Refer to the pin configuration below when assembling the
cable that will connect to the RJ-45 jack.
RJ-45 Pin(s)
Function
1 and 2................................TX pair
3.......................................TX shield
4 and 5................................RX pair
6......................................RX shield
2) Plug the modular cable connector into the RJ-45 jack.
3) Connect the coaxial cables to the TX Out and RX In
connectors. Congratulations, you have finished installing the
Model 460!
Installing the Model 460-TBP
Do the following:
1) Strip the outer jacket insulation from the twisted pairs about 1
inch.
2) Strip back the insulation on each of the wires about .25 inches.
3) Connect one pair of wires to the two XMT (transmit) positions
on the terminal block. The Model 460-TBP is not polarity
sensitive so either wire may connect to either pole.
See figure at upper right.
4) Connect the other pair of wires to the two RCV (receive)
positions on the terminal block.
5) Connect the coaxial cables to the TX Out and RX In
connectors.
6
PATTON MODEL 460 SERIES SPECIFICATIONS
Transmission Line: ITU/CCITT G.703 (unstructured)
Data Rate: 2.048 Mbps maximum
Unbalanced Coaxial
Connection: Dual coax BNC connectors, male or female
(RG 59 or 2002 coax) and Nominal Line
Impedance = 75 Ohms
Balanced Twisted Pair
Connection: Single 8-pin RJ-45 jack, shielded (two
twisted-pair), Nominal Line Impedance =
120 Ohms and 4-position, removable
terminal block
Power Supply: None required, passive device
Operating Temperature: 0-50° Celcius (32-122° Fahrenheit)
Coaxial Twisted Pair
Isolation: 1500V rms
Compliance: CE approved
Dimensions: 0.8H x 1.7W x 2.7D in. (6.86H x 4.32W x
2.03D cm.)