Multi-Port T1/E1/PRI IPv6-Ready
Enterprise VoIP Media Gateway
User Manual
Important
This is a Class A device and is not intended for use in a residential environment.
Sales Office:+1 (301) 975-1000
Technical Support:+1 (301) 975-1007
E-mail:support@patton.com
WWW:www.patton.com
Part Number: 07MSN4970, Rev. A
Revised: May 24, 2012
Patton Electronics Company, Inc.
7622 Rickenbacker Drive
Gaithersburg, MD 20879 USA
Tel: +1 (301) 975-1000
Fax: +1 (301) 869-9293
Support: +1 (301) 975-1007
Web: www.patton.com
E-mail: support@patton.com
Trademark Statement
The terms SmartNode and SmartWare are trademarks of Patton Electronics Company.
All other trademarks presented in this document are the property of their
respective owners.
The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document.
Important Information
To use virtual private network (VPN) and/or AES/DES/3DES encryption capabilities
with the SmartNode 4970, you may need to purchase additional licenses, hardware,
software, network connection, and/or service. Contact sales@patton.com or
+1 (301) 975-1000 for assistance.
Warranty Information
The software described in this document is furnished under a license and may be used
or copied only in accordance with the terms of such license. For information about the
license, see Appendix F, "End user license agreement" on page 55 or go towww.patton.com.
Patton Electronics warrants all SmartNode router components to be free from defects,
and will—at our option—repair or replace the product should it fail within one year
from the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover
customer damage, abuse or unauthorized modification. If the product fails to perform
as warranted, your sole recourse shall be repair or replacement as described above.
Under no condition shall Patton Electronics be liable for any damages incurred by the
use of this product. These damages include, but are not limited to, the following: lost
profits, lost savings and incidental or consequential damages arising from the use of or
inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed
an acceptance of these terms by the user.
Summary Table of Contents
1 General information...................................................................................................................................... 13
5 Contacting Patton for assistance ................................................................................................................... 31
A Compliance information .............................................................................................................................. 34
B Specifications ................................................................................................................................................ 38
C Cabling ......................................................................................................................................................... 44
D Port pin-outs ................................................................................................................................................ 49
E SmartNode 4970 factory configuration ........................................................................................................ 52
F End user license agreement ........................................................................................................................... 55
3
Table of Contents
Summary Table of Contents ........................................................................................................................... 3
Table of Contents ........................................................................................................................................... 4
List of Figures ................................................................................................................................................. 7
List of Tables .................................................................................................................................................. 8
About this guide ............................................................................................................................................. 9
Safety when working with electricity ...............................................................................................................11
General observations .......................................................................................................................................12
Typographical conventions used in this document................................................................................................ 12
General conventions .......................................................................................................................................12
1 General information...................................................................................................................................... 13
SN4970 model codes ......................................................................................................................................15
SN4971 model codes ......................................................................................................................................15
SmartNode 4970 front panel.................................................................................................................................18
Planning the installation ........................................................................................................................................23
Site log ............................................................................................................................................................23
Network information ......................................................................................................................................23
IP related information .....................................................................................................................................23
AC Power Mains .............................................................................................................................................24
Location and mounting requirements .............................................................................................................24
Installing the gateway ............................................................................................................................................24
Placing the SmartNode ...................................................................................................................................24
Connecting the PRI ..................................................................................................................................25
Connecting the 10/100/1000Base-T Ethernet cable
Connecting the power supply ....................................................................................................................26
Configuring the desired IP address ........................................................................................................................28
Factory-default IP settings ...............................................................................................................................28
Connecting the SmartNode to the network...........................................................................................................28
Loading the configuration (optional).....................................................................................................................29
Out-of-warranty service .............................................................................................................................33
Returns for credit ......................................................................................................................................33
Return for credit policy .............................................................................................................................33
A Compliance information .............................................................................................................................. 34
FCC Part 68 (ACTA) Statement ...........................................................................................................................36
Industry Canada Notice ........................................................................................................................................36
CE Declaration of Conformity..............................................................................................................................37
Authorized European Representative.....................................................................................................................37
B Specifications ................................................................................................................................................ 38
Data connectivity ..................................................................................................................................................39
Fax and modem support........................................................................................................................................39
IP services..............................................................................................................................................................40
Identification of the SmartNode devices via SNMP...............................................................................................42
C Cabling ......................................................................................................................................................... 44
E1 PRI ..................................................................................................................................................................47
5
SmartNode 4970 User Manual Table of Contents
T1 PRI ..................................................................................................................................................................48
D Port pin-outs ................................................................................................................................................ 49
PRI port ................................................................................................................................................................51
E SmartNode 4970 factory configuration ........................................................................................................ 52
F End user license agreement ........................................................................................................................... 55
End User License Agreement.................................................................................................................................56
2. Title ............................................................................................................................................................56
3. Term ...........................................................................................................................................................56
4. Grant of License ..........................................................................................................................................56
7. Other licenses .............................................................................................................................................57
This guide describes the SmartNode 4970 hardware, installation and basic configuration. For detailed software
configuration information refer to the SmartWare Software Configuration Guide and the available Configura-
tion Notes.
Audience
This guide is intended for the following users:
• Operators
• Installers
• Maintenance technicians
Structure
This guide contains the following chapters and appendices:
• Chapter 1 on page 13 provides information about router features and capabilities
• Chapter 2 on page 20 contains an overview describing router operation and applications
• Chapter 3 on page 22 provides hardware installation procedures
• Chapter 4 on page 27 provides quick-start procedures for configuring the SmartNode router
• Chapter 5 on page 31 contains information on contacting Patton technical support for assistance
• Appendix A on page 34 contains compliance information for the router
• Appendix B on page 38 contains specifications for the routers
• Appendix C on page 44 provides cable recommendations
• Appendix D on page 49 describes the router’s ports and pin-outs
• Appendix E on page 52 lists the factory configuration settings for SmartNode 4970
• Appendix F on page 55 provides license information that describes acceptable usage of the software pro-
vided with the SmartNode 4970
For best results, read the contents of this guide before you install the router.
9
SmartNode 4970 User Manual
Precautions
Notes, cautions, and warnings, which have the following meanings, are used throughout this guide to help you
become aware of potential problems. Warnings are intended to prevent safety hazards that could result in personal injury. Cautions are intended to prevent situations that could result in property damage or
impaired functioning.
Note
IMPORTANT
CAUTION
CAUTION
WARNING
WARNING
A note presents additional information or interesting sidelights.
The alert symbol and IMPORTANT heading calls attention to
important information.
The alert symbol and CAUTION heading indicate a potential hazard. Strictly follow the instructions to avoid property damage.
The shock hazard symbol and CAUTION heading indicate a
potential electric shock hazard. Strictly follow the instructions to
avoid property damage caused by electric shock.
The alert symbol and WARNING heading indicate a potential safety hazard.
Strictly follow the warning instructions to avoid personal injury.
The shock hazard symbol and WARNING heading indicate a potential electric
shock hazard. Strictly follow the warning instructions to avoid injury caused
by electric shock.
10
SmartNode 4970 User Manual
Safety when working with electricity
•
Do not open the device when the power cord is connected. For systems
without a power switch and without an external power adapter, line volt-
WARNING
ages are present within the device when the power cord is connected.
•
For devices with an external power adapter, the power adapter shall be a
listed Limited Power Source The mains outlet that is utilized to power the
device shall be within 10 feet (3 meters) of the device, shall be easily
accessible, and protected by a circuit breaker in compliance with local regulatory requirements.
•
For AC powered devices, ensure that the power cable used meets all applicable standards for the country in which it is to be installed.
•
For AC powered devices which have 3 conductor power plugs (L1, L2 &
GND or Hot, Neutral & Safety/Protective Ground), the wall outlet (or
socket) must have an earth ground.
•
For DC powered devices, ensure that the interconnecting cables are rated
for proper voltage, current, anticipated temperature, flammability, and
mechanical serviceability.
•
WAN, LAN & PSTN ports (connections) may have hazardous voltages
present regardless of whether the device is powered ON or OFF. PSTN
relates to interfaces such as telephone lines, FXS, FXO, DSL, xDSL, T1, E1,
ISDN, Voice, etc. These are known as “hazardous network voltages” and
to avoid electric shock use caution when working near these ports. When
disconnecting cables for these ports, detach the far end connection first.
•
Do not work on the device or connect or disconnect cables during periods of
lightning activity
WARNING
WARNING
This device contains no user serviceable parts. This device can only be
repaired by qualified service personnel.
This device is NOT intended nor approved for connection to the PSTN. It is
intended only for connection to customer premise equipment.
In accordance with the requirements of council directive 2002/
96/EC on Waste of Electrical and Electronic Equipment (WEEE),
ensure that at end-of-life you separate this product from other
waste and scrap and deliver to the WEEE collection system in
your country for recycling.
11
SmartNode 4970 User Manual
Always follow ESD prevention procedures when removing and
replacing cards.
CAUTION
Wear an ESD-preventive wrist strap, ensuring that it makes good
skin contact. Connect the clip to an unpainted surface of the
chassis frame to safely channel unwanted ESD voltages
to ground.
To properly guard against ESD damage and shocks, the wrist
strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.
General observations
• Clean the case with a soft slightly moist anti-static cloth
• Place the unit on a flat surface and ensure free air circulation
• Avoid exposing the unit to direct sunlight and other heat sources
• Protect the unit from moisture, vapors, and corrosive liquids
Typographical conventions used in this document
This section describes the typographical conventions and terms used in this guide.
General conventions
The procedures described in this manual use the following text conventions:
Table 1. General conventions
ConventionMeaning
Garamond blue type
Futura bold typeCommands and keywords are in boldface font.
Futura bold-italic typeParts of commands, which are related to elements already named by the user, are
Italicized Futura typeVariables for which you supply values are in italic font
Futura typeIndicates the names of fields or windows.
Garamond bold typeIndicates the names of command buttons that execute an action.
< >Angle brackets indicate function and keyboard keys, such as <SHIFT>, <CTRL>,
[ ]Elements in square brackets are optional.
{a | b | c}Alternative but required keywords are grouped in braces ({ }) and are separated
screen
nodeThe leading IP address or nodename of a SmartNode is substituted with node in
SNThe leading SN on a command line represents the nodename of the SmartNode
#An hash sign at the beginning of a line indicates a comment line.
Indicates a cross-reference hyperlink that points to a figure, graphic, table, or section heading. Clicking on the hyperlink jumps you to the reference. When you
have finished reviewing the reference, click on the Go to Previous View
button in the Adobe® Acrobat® Reader toolbar to return to your starting point.
in boldface italic font.
<C>, and so on.
by vertical bars ( | )
Terminal sessions and information the system displays are in
SN4970 model codes ......................................................................................................................................15
SN4971 model codes ......................................................................................................................................15
SmartNode 4970 front panel.................................................................................................................................18
13
SmartNode 4970 User Manual 1 • General information
SmartNode 4970 overview
As enterprises move toward unified communications, the SmartNode™ 4970 Enterprise VoIP Media Gateway (see figure 1) provides a smooth transition by either IP-enabling traditional PBX systems for SIP trunking
over existing Internet connection, adding PSTN-breakout for number portability, or enabling PSTN access for
IP PBX and unified communications systems. Preserve investment in legacy phone equipment while taking the
next step toward unified communications with Patton’s proven SmartNode™ VoIP solutions.
Figure 1. SmartNode 4970
The SmartNode 4970 performs the following major functions:
• Up to 120 VoIP Calls—With four T1/E1/PRI ports and one Gigabit Ethernet port.
• Proven Interoperability—Interoperable with all the major-brand softswitches and IP-PBXs.
T.38 and SuperG3 FAX—over TDM/PSTN and IP/Ethernet services simultaneously.
• Transparent Telephony Features—Complex number manipulation and mapping for seamless integration
with existing infrastructures, CLIP, CLIR, hold, transfer and much more.
• High Precision Clock—Delivers DECT PBX interoperability with reliable fax performance.
SmartNode 4970 overview14
SmartNode 4970 User Manual 1 • General information
SN4970 model codes
The SmartNode 4970 series consists of several models. They differ in the number of PRI ports and voice channels supported. All models come equipped with one 10/100/1000Base-T Ethernet port. The SmartNode 4970
PRI ports and voice channels are listed in table 2.
Table 2. SmartNode 4970 PRI Ports and Voice Channels
The high precision SmartNode 4971 models have a Stratum III clock. The Stratum III clock provides a clock
source of < 5 ppm. For PBXs that used to rely on PSTN for accurate clock source, the SmartNode 4971 can
provide a PSTN-equivalent high precision clock. The popular DECT PBX needs such high precision clocks.
Note
For high precision clock models, replace SN4970 with SN4971 in
the model code.
SmartNode 4970 overview15
SmartNode 4970 User Manual 1 • General information
SmartNode 4970 rear panel
The SmartNode 4970 rear panel ports are described in table 3.
0
/3
0
/
2
0
/
1
T
0
1
/0
/
E
1
E
T
H
0
/
1
C
o
n
s
Reset
o
le
R
S
2
3
2
Power
SN4970/1E30V
0/0
T1/E1
T1/E1
PRI port 0/0
0/00/10/20/3
T1/E1
T1/E1
PRI ports 0/3–0/0
ETH 0/0
10/100/1000Base-T port
Figure 2. SN4970 rear panel
ConsoleETH 0/0
Reset
RS-232
SN4970/4E120VR
ConsoleETH 0/0
Reset
RS-232
Console
RS-232 port
RESET
button
SmartNode 4970 rear panel16
SmartNode 4970 User Manual 1 • General information
Table 3. Rear panel ports
PortDescription
ETH 0/0
PRI 0/0RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet-
PRI 0/1RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet-
PRI 0/2RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet-
PRI 0/3RJ-45 connector providing E1 (2.048Mbps) or T1(1.533 Mbps) PRI interface, meet-
Console
DC power input
Reset
Auto-MDX Gigabit-Ethernet port, RJ-45 (see
WAN device (for example, a cable modem, DSL modem, or fiber modem). Note:
Only full duplex modes are supported.
ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1
interface cable for 120 Ohm balanced connections to connect the SmartNode with
an NT or ET, e.g. a PBX or LE.
ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1
interface cable for 120 Ohm balanced connections to connect the SmartNode with
an NT or ET, e.g. a PBX or LE.
ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1
interface cable for 120 Ohm balanced connections to connect the SmartNode with
an NT or ET, e.g. a PBX or LE.
ing all requirements of ITU-T recommendations for G.703. Use a shielded E1 or T1
interface cable for 120 Ohm balanced connections to connect the SmartNode with
an NT or ET, e.g. a PBX or LE.
Used for service and maintenance, the Console port (see
connector, connects the product to a serial terminal such as a PC or ASCII terminal
(also called a dumb terminal).
Electricity supply socket. (see
The reset button (see
•
Restart the unit with the current startup configuration—Press (for less than 1 second)
and release the Reset button to restart the unit with the current startup configuration.
•
Restart the unit with factory default configuration—Press the Reset button for
5 seconds until the Power LED (see
the unit with factory default configuration.
•
Restart the unit in bootloader mode (to be used only by trained SmartNode technicians)—Starting with the unit powered off, press and hold the Reset button as
you apply power to the unit. Release the Reset button when the Power LED starts
blinking so the unit will enter bootloader mode.
figure 2
figure 2
) has three functions:
).
figure 3
figure 2
), connects the unit to an Ethernet
figure 2
on page 18) starts blinking to restart
), an RS-232 RJ-45
SmartNode 4970 rear panel17
SmartNode 4970 User Manual 1 • General information
SmartNode 4970 front panel
Figure 3 shows SmartNode 4970 front panel LEDs, the LED definitions are listed in table 4.
Enterprise T1/E1 VoIP Gatew
S
m
a
rtN
o
d
e
ay
SN4970/1E30V
SmartNode
Enterprise T1/E1 VoIP Gateway
Power
Activity
VoIP
Ethernet 0/0
Link
Ethernet 0/0
100
T1/E1 Port 0
Ethernet 0/0
1000
Ethernet 0/0
Activity
T1/E1 Port 0
T1/E1 Port 3
T1/E1 Port 1 T1/E1 Port 2
Figure 3. SmartNode 4970 front panel
SN4970/4E120VR
SmartNode
Enterprise T1/E1 VoIP Gateway
SmartNode 4970 front panel18
SmartNode 4970 User Manual 1 • General information
Table 4. SN4970 Front and Rear panel LEDs
LEDDescription
NoteIf an error occurs, all LEDs will flash once per second.
PowerWhen lit, indicates power is applied.
RunWhen lit, the unit is in normal operation. Flashes once per second during
boot (startup).
VoIP Link
Ethernet Link
Ethernet Speed
10/100
Ethernet Speed
1000
Ethernet Activity
PRI Link/Status
•
On indicates the gateway is registered to an H.323 gatekeeper/SIP server, or,
in the case of direct routing, has at least one active VoIP connection.
•
Off indicates the unit is not configured or registered, or has no active directrouted VoIP connection.
•
Flashing green indicates that the unit is attempting to register or has failed
to register.
•
On when the Ethernet connection on the corresponding port has a
link indication.
When the Ethernet Link LED is on, then:
•
On when the Ethernet is connected to a 100Mb network.
•
Off when the Ethernet is connected to a 10Mb network.
•
On when the Ethernet is connected to a 1000Mb network.
•
Flashes when data is received or transmitted at the corresponding Ethernet port.
•
On = in frame, no errors
•
Flash = Error
•
Fast Flash = Signal detected but no frame synchronization or aquisition is in
process
•
Slow Flash = Framing synchronized, Signaling not established
Application—Convert Legacy PBX to VoIP ..........................................................................................................21
20
SmartNode 4970 User Manual 2 • Applications overview
Introduction
Patton’s SmartNode Enterprise VoIP Media Gateways deliver the features you need for advanced multiservice
voice and data network applications. They combine high quality voice-over-IP with powerful quality of service
routing functions to build professional and reliable VoIP and data networks. This chapter describes typical
applications for which this SmartNode is uniquely suited.
Note
Detailed configuration information for SmartNode applications can be
found online at www.patton.com/smartnode.
Application—Convert Legacy PBX to VoIP
The SmartNode 4970 Series can be used to make and receive calls to and from the public ISDN network and
Internet Telephony services on any ISDN Terminal (Phone or PBX) (see figure 4). Using individually configurable routing tables, an outbound call can be directed to the local PSTN connection or to an Internet telephony service provider (ISTP). Inbound calls from the Internet and the PSTN can ring the same phone.
Figure 4. Internet telephony IAD application
For an installation where there are existing routers and access modems, the SN4970 is a cost-effective solution
to bring SIP-trunking service to a traditional PBX. .
Introduction21
Chapter 3 SmartNode installation
Chapter contents
Planning the installation ........................................................................................................................................23
Site log ............................................................................................................................................................23
Network information ......................................................................................................................................23
IP related information .....................................................................................................................................23
AC Power Mains .............................................................................................................................................24
Location and mounting requirements .............................................................................................................24
Installing the gateway ............................................................................................................................................24
Placing the SmartNode ...................................................................................................................................24
Connecting the PRI ..................................................................................................................................25
Connecting the 10/100/1000Base-T Ethernet cable ..................................................................................25
Connecting the power supply ....................................................................................................................26
22
SmartNode 4970 User Manual 3 • SmartNode installation
Planning the installation
Before installing the gateway router device, the following tasks should be completed:
• Create a network diagram (see section “Network information” on page 23)
• Gather IP related information (see section “IP related information” on page 23 for more information)
• Install the hardware and software needed to configure the SmartNode. (See section “Software tools” on
page 24)
• Verify power source reliability (see section “Power source” on page 26).
After you have finished preparing for gateway router installation, go to section “Installing the gateway” on
page 24 to install the device.
Site log
Patton recommends that you maintain a site log to record all actions relevant to the system, if you do not
already keep such a log. Site log entries should include information such as listed in table 5.
Table 5. Sample site log entries
EntryDescription
InstallationMake a copy of the installation checklist and insert it into the site log
Upgrades and maintenanceUse the site log to record ongoing maintenance and expansion history
Configuration changesRecord all changes and the reasons for them
MaintenanceSchedules, requirements, and procedures performed
CommentsNotes, and problems
SoftwareChanges and updates to SmartWare software
Network information
Network connection considerations that you should take into account for planning are provided for several
types of network interfaces are described in the following sections.
Network Diagram
Draw a network overview diagram that displays all neighboring IP nodes, connected elements and
telephony components.
IP related information
Before you can set up the basic IP connectivity for your SmartNode 4970 you should have the following information:
• IP addresses used for Ethernet port
• Subnet mask used for Ethernet port
Planning the installation23
SmartNode 4970 User Manual 3 • SmartNode installation
• IP addresses of central H.323 gatekeeper (if used)
• IP addresses and/or URL of SIP servers or Internet telephony services (if used)
• Login and password for SIP or H.323 based telephony services
• IP addresses of central TFTP server used for configuration upload and download (optional)
Software tools
You will need a PC (or equivalent) with Windows Telnet or a program such as Tera Term Pro Web to configure the software on your SmartNode router.
AC Power Mains
If you suspect that your AC power is not reliable, for example if room lights flicker often or there is machinery
with large motors nearby, have a qualified professional test the power. Patton recommends that you include an
uninterruptible power supply (UPS) in the installation to ensure that VoIP service is not impaired if the
power fails. Refer to “Connecting the power supply” on page 26.
Location and mounting requirements
The SmartNode router is intended to be placed on a desktop or similar sturdy, flat surface that offers easy
access to the cables. Allow sufficient space at the rear of the chassis for cable connections. Additionally, you
should consider the need to access the unit for future upgrades and maintenance.
Note
Under the rack mount option, the chassis can be equipped with rack mount
ears that allow for use in a 19” rack.
Installing the gateway
SmartNode hardware installation consists of the following:
• Placing the device at the desired installation location (see section “Placing the SmartNode” on page 24)
• Connecting the interface and power cables (see section “Installing cables”)
When you finish installing the SmartNode, go to chapter 4, “Initial configuration” on page 27.
Placing the SmartNode
Place the unit on a desktop or similar sturdy, flat surface that offers easy access to the cables. The unit should
be installed in a dry environment with sufficient space to allow air circulation for cooling.
Note
Installing cables
For proper ventilation, leave at least 2 inches (5 cm) to the left, right, front,
and rear of the unit.
Do not work on the system or connect or disconnect cables during periods of
lightning activity.
WARNING
Installing the gateway24
SmartNode 4970 User Manual 3 • SmartNode installation
Connect the cables in the following order:
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and
CAUTION
mechanical serviceability.
1. Connect the T1/E1 cables to the PRI T1/E1 ports (see Appendix C on page 44 and Appendix D on
page 49).
2. Connect the 10/100/1000Base-T Ethernet (see section “Connecting the 10/100/1000Base-T Ethernet
cable” on page 25)
3. Connect the power mains cable (see section “Connecting the power supply” on page 26)
Connecting the PRI
The SmartNode comes with one or four PRI ports. These ports are usually connected to a PBX or switch (local
exchange (LE) ). Each PRI T1/E1 port is a RJ-48C receptacle. In most cases, a straight-through RJ-45 can be used
to connect the PRI. Each port can be configured as NT (clock master) or TE (clock slave).
For details on the PRI port pin-out and ISDN cables, refer to Appendix C, “Cabling” on page 43 and Appendix D, “port pin-outs” on page 47.
Connecting the 10/100/1000Base-T Ethernet cable
The SmartNode 4970 has automatic MDX (auto-crossover) detection and configuration on the Ethernet port.
The port can be connected to a host or hub/switch with a straight-through or cross-over wired cable. Connect
the LAN network to ETH 0/0.
Note
The SmartNode Ethernet port operates in Full Duplex mode only. Do not
connect to Half Duplex ports. For best results, use auto-negotiation. Auto
negotiation is mandatory when using 1000BaseT (Gigabit) Ethernet.
For details on the Ethernet port pinout and cables, refer to Appendix C, “Cabling” on page 44 and Appendix
D, “Port pin-outs” on page 49.
Installing the gateway25
SmartNode 4970 User Manual 3 • SmartNode installation
Connecting the power supply
•
Do not connect power to the AC Mains at this time.
•
The external power adapter shall be a listed Limited Power
WARNING
Source.
•
The 4970 external power supply automatically adjusts to
accept an input voltage from 100 to 240 VAC (50/60 Hz).
Verify that the proper voltage is present before plugging the
power cord into the receptacle. Failure to do so could result in
equipment damage.
1. Insert the barrel type connector end of the AC power cord into the external power supply connector (see
figure 5).
2. Insert the female end of the power cord into the internal power supply connector.
–
+
12V, 1.25A
Power
0
1
2
T1/E1
3
T1/E1
Ports 0-3
ETH 0
10/100/1000Base-T port
RESET
button
ETH
0
t
e
s
Console
e
R
RS-232
Console
RS-232 port
Figure 5. Power connector location on rear panel
3. Verify that the AC power cord included with your router is compatible with local standards. If it is not,
refer to chapter 5, “Contacting Patton for assistance” on page 32 to find out how to replace it with a compatible power cord.
4. Connect the male end of the power cord to an appropriate power outlet.
5. Verify that the green Power LED is lit (see figure 5).
Configuring the desired IP address ........................................................................................................................28
Factory-default IP settings ...............................................................................................................................28
Connecting the SmartNode to the network...........................................................................................................28
Loading the configuration (optional).....................................................................................................................29
SmartNode 4970 User Manual 4 • Initial configuration
Introduction
This chapter leads you through the basic steps to set up a new SmartNode and to download a configuration.
Setting up a new SmartNode consists of the following main steps:
Note
If you haven’t already installed the SmartNode, refer to chapter 3,
“SmartNode installation” on page 22.
• Configuring the desired IP address
• Connecting the SmartNode to the network
• Loading the configuration (optional)
Configuring the desired IP address
Factory-default IP settings
The factory default configuration for the Ethernet interface IP addresses and network masks are listed in table 6.
The Ethernet 0/0 port uses the DHCP client to automatically assign the IP address and network mask.
Table 6. Factory default IP address and network mask configuration
IP AddressNetwork Mask
Ethernet 0 (ETH 0/0)DHCPDHCP
Connecting the SmartNode to the network
The SmartNode 4970 Series is equipped with an Auto-MDX Ethernet port, so you can use straight-through or
crossover cables for host or hub/switch connections (see figure 6).
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and
CAUTION
Introduction28
mechanical serviceability.
SmartNode 4970 User Manual 4 • Initial configuration
0/3
0/2
0/1
T1/E1
0/0
ETH
0/1
Console
LAN
LAN (ETH 0/0)
Reset
RS-232
Figure 6. Connecting the SmartNode to the network
You can check the connection with the ping command from the SmartNode to another host on the network.
172.16.1.99(if-ip)[LAN]#ping <IP Address of the host>
Loading the configuration (optional)
Patton provides a collection of configuration templates on the support page at www.patton.com/smartnode—one of which may be similar enough to your application that you can use it to speed up configuring the
SmartNode. Simply download the configuration note that matches your application to your PC. Adapt the
configuration as described in the configuration note to your network (remember to modify the IP address) and
copy the modified configuration to a TFTP server. The SmartNode can now load its configuration from this
server.
Note
In this example we assume the TFTP server on the host with the IP address 172.16.1.11 and the configuration
named SN.cfg in the root directory of the TFTP server.
If your application is unique and not covered by any of Patton’s configuration templates, you can manually configure the SmartNode instead of loading a configuration file template. In that case, refer to the SmartNode Series SmartWare Software Configuration Guide for information on configuring the
SmartNode device.
Loading the configuration (optional)29
SmartNode 4970 User Manual 4 • Initial configuration
After the SmartNode has been rebooted the new startup configuration will be activated.
When you issue the reload command, the SmartNode will ask
if you want to copy the running configuration to the startup configuration. Since you just downloaded a configuration file to the
IMPORTANT
startup configuration you must answer this question with NO.
Otherwise, the downloaded configuration will be overwritten
and lost!
172.16.1.99(if-ip)[WAN]#reload
Running configuration has been changed.
Do you want to copy the 'running-config' to the 'startup-config'?
Press 'yes' to store, 'no' to drop changes : no
Press 'yes' to restart, 'no' to cancel : yes
The system is going down
Additional information
For detailed information about configuring and operating guidance, set up procedures, and troubleshooting,
refer to the SmartNode Series SmartWare Software Configuration Guide available online at www.patton.com/manuals.
Out-of-warranty service .............................................................................................................................33
Returns for credit ......................................................................................................................................33
Return for credit policy .............................................................................................................................33
SmartNode 4970 User Manual 5 • Contacting Patton for assistance
Introduction
This chapter contains the following information:
• “Contact information”—describes how to contact Patton technical support for assistance.
• “Warranty Service and Returned Merchandise Authorizations (RMAs)”—contains information about the
warranty and obtaining a return merchandise authorization (RMA).
Contact information
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other
products we recommend you begin your search for answers by using our technical knowledge base. Here, we
have gathered together many of the more commonly asked questions and compiled them into a searchable
database to help you quickly solve your problems.
Patton support headquarters in the USA
• Online support: available at www.patton.com
• E-mail support: e-mail sent to support@patton.com will be answered within 1 business day
• Telephone support: standard telephone support is available five days a week—from 8:00 am to
5:00 pm EST (1300 to 2200 UTC/GMT)—by calling +1 (301) 975-1007
• Fax: +1 (253) 663-5693
Alternate Patton support for Europe, Middle East, and Africa (EMEA)
• Online support: available at www.patton.com
• E-mail support: e-mail sent to support@patton.com will be answered within 1 business day
• Telephone support: standard telephone support is available five days a week—from 9:00 am to
5:30 pm CET (0800 to 1630 UTC/GMT)—by calling +41 (0)31 985 25 55
• Fax: +41 (0)31 985 25 26
Warranty Service and Returned Merchandise Authorizations (RMAs)
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before shipment. All of our products are backed by a comprehensive warranty program.
Note
Warranty coverage
Our products are under warranty to be free from defects, and we will, at our option, repair or replace the product should it fail within one year from the first date of shipment. Our warranty is limited to defects in workmanship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or
unauthorized modification.
If you purchased your equipment from a Patton Electronics reseller, ask your
reseller how you should proceed with warranty service. It is often more convenient for you to work with your local reseller to obtain a replacement.
Patton services our products no matter how you acquired them.
Introduction32
SmartNode 4970 User Manual 5 • Contacting Patton for assistance
Out-of-warranty service
Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no
longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastrophes may require replacement.
Returns for credit
Customer satisfaction is important to us, therefore any product may be returned with authorization within 30
days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or
you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is
not responsible for equipment returned without a Return Authorization.
Return for credit policy
• Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
• 30 to 60 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase price).
• Over 60 days: Products will be accepted for repairs only.
RMA numbers
RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
• Completing a request on the RMA Request page in the Support section at www.patton.com
• By calling +1 (301) 975-1007 and speaking to a Technical Support Engineer
• By sending an e-mail to returns@patton.com
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use
the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions
The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton Electronics Company
RMA#: xxxx
7622 Rickenbacker Dr.
Gaithersburg, MD 20879-4773 USA
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return
shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs)33
FCC Part 68 (ACTA) Statement ...........................................................................................................................36
Industry Canada Notice ........................................................................................................................................36
CE Declaration of Conformity..............................................................................................................................37
Authorized European Representative.....................................................................................................................37
34
SmartNode 4970 User Manual A • Compliance information
Compliance
EMC
• EN55022, Class A
• EN55024
Safety
• IEC/EN60950-1, 2nd edition
PSTN Regulatory
• ACTA (Part 68)
• IC CS-03
• AS/ACIF S016:2001
• AS/ACIF S038:2001
• ETSI TBR 12, TBR 12/A1 & TBR 13
• TBR 4
• TNA 117: 1992
• TNA 134: 1997
• PTC 220
Compliance35
SmartNode 4970 User Manual A • Compliance information
FCC Part 68 (ACTA) Statement
This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom
side of this equipment is a label that contains—among other information—a product identifier in the format
US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
The method used to connect this equipment to the premises wiring and telephone network must comply with
the applicable FCC Part 68 rules and requirements adopted by the ACTA.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance
that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone
company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint
with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could
affect the operation of the equipment. If this happens the telephone company will provide advance notice in
order for you to make necessary modifications to maintain uninterrupted service.
If trouble is experienced with this equipment, for repair or warranty information, please contact our company.
If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public
service commission or corporation commission for information.
Industry Canada Notice
This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is
confirmed by the registration number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment.
This Declaration of Conformity means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to
the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using
an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line
individual service may be extended by means of a certified connector assembly (telephone extension cord). The
customer should be aware that compliance with the above condition may not prevent degradation of service in
some situations. Repairs to some certified equipment should be made by an authorized maintenance facility
designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the ground connections of the power utility, telephone lines
and internal metallic water pipe system, are connected together. This protection may be particularly important
in rural areas.
FCC Part 68 (ACTA) Statement36
SmartNode 4970 User Manual A • Compliance information
CE Declaration of Conformity
Patton Electronics, Inc declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC relating to electromagnetic compatibility and Directive
2006/95/EC relating to electrical equipment designed for use within certain voltage limits. The Declaration of
Conformity may be obtained from Patton Electronics, Inc at www.patton.com/certifications.
The safety advice in the documentation accompanying this device shall be obeyed. The conformity to the
above directive is indicated by CE mark on the device.
Data connectivity ..................................................................................................................................................39
Fax and modem support........................................................................................................................................39
IP services..............................................................................................................................................................40
According to table 7, an SNMP get request to .iso.org.dod.internet.mgmt.mib-2.system.sysObjectID of a SmartNode 4970/1E15V/EUI device reads out a numeric OID of 1.3.6.1.4.1.1768.100.4.23.1, which represents a
SmartNode 4970/1E15V/EUI device. The mapping of the sysObjectID to each of the SmartNode model is
realized with the SmartNode product identification MIB.
The SNMP agent running in SmartWare is SNMP version 1
(SNMPv1) compliant. SNMP version 2 (SNMPv2) and SNMP
version 3 (SNMPv3) are not currently supported.
IMPORTANT
Identification of the SmartNode devices via SNMP43
E1 PRI ..................................................................................................................................................................47
T1 PRI ..................................................................................................................................................................48
44
SmartNode 4970 User Manual C • Cabling
Introduction
This section provides information on the cables used to connect the SmartNode and the interface cards to the
existing network infrastructure and to third party products.
Console
The SmartNode can be connected to a serial terminal over its serial console port, as depicted in figure 7.
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and
CAUTION
mechanical serviceability.
0/3
0/2
0/1
T1/E
0/0
1
Note
ETH
0/1
Serial Terminal
Note A Patton Model 16F-561 RJ45 to DB-9 adapter is included with
each SmartNode 4970 Series device
Figure 7. Connecting a serial terminal
See section “Console port” on page 50 for console port pin-outs.
Console
Reset
RS
-232
Introduction45
SmartNode 4970 User Manual C • Cabling
Ethernet
Ethernet devices (10Base-T/100Base-T/1000Base-T) are connected to the SmartNode over a cable with RJ-45
plugs. The Ethernet port on the SN4970 is Auto-MDX and uses any straight or crossover cable to connect to
hubs, switches, PCs or other devices.
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and
CAUTION
0/3
0/2
0/1
T1/E1
mechanical serviceability.
0/0
ETH
0/1
Console
Reset
R
S-232
Hub
Straight-through cable
RJ-45, male
1
2
3
6
RJ-45, male
1
2
3
6
Note: Other pins are not used.
Figure 8. Typical Ethernet straight-through cable diagram for 10/100Base-T
RJ-45, male
1
2
3
6
4
5
7
8
RJ-45, male
1
2
3
6
4
5
7
8
Figure 9. Typical Ethernet straight-through cable diagram for 1000Base-T
Ethernet46
SmartNode 4970 User Manual C • Cabling
E1 PRI
The E1 PRI is usually connected to a PBX or switch—local exchange (LE). Type and pin outs of these devices
vary depending on the manufacturer. In most cases, a straight-through RJ-45 to RJ-45 can be used to connect
the PRI with a PBX. A cross-over cable is required to connect to an NT device, as illustrated in figure 10 on
page 47.
Hazardous network voltages are present in the PRI cables. If you detach the
cable, detach the end away from the SmartNode or interface card first to avoid
possible electric shock. Network hazardous voltages may be present on the
WARNING
WARNING
device in the area of the PRI port, regardless of when power is turned OFF.
To prevent damage to the system, make certain you connect the
PRI cable to the PRI port only and not to any other RJ-45 socket.
0
/
3
RJ-48C, male
RX Ring
RX Tip
RX Shield
TX Ring
TX Tip
TX Shield
N/C
N/C
0
/
2
0
/
1
T
0
1
/
/
0
E
1
E
T
H
0
/
1
C
o
n
s
Reset
o
l
e
R
S
2
3
2
Cross-over cable
Figure 10. Connecting an E1 PRI port to an NT1
1
2
3
4
5
6
7
8
*N/C = No connection*
NT
1
2
3
4
5
6
7
8
RJ-48C, male
RX Ring
RX Tip
RX Shield
TX Ring
TX Tip
TX Shield
N/C
N/C
E1 PRI47
Figure 11. E1 PRI port crossover cable
SmartNode 4970 User Manual C • Cabling
T1 PRI
The T1 PRI is usually connected to a PBX or switch—local exchange (LE). Type and pin outs of these devices
vary depending on the manufacturer. In most cases, a straight-through RJ-45 to RJ-45 can be used to connect
the PRI with a PBX. A cross-over cable is required to connect to an NT device, as illustrated in figure 12 on
page 48.
Hazardous network voltages are present in the PRI cables. If you detach the
cable, detach the end away from the SmartNode or interface card first to avoid
possible electric shock. Network hazardous voltages may be present on the
WARNING
WARNING
device in the area of the PRI port, regardless of when power is turned OFF.
To prevent damage to the system, make certain you connect the
PRI cable to the PRI port only and not to any other RJ-45 socket.
0/3
RJ-45, male
RX Ring
RX Tip
RX Shield
TX Ring
TX Tip
TX Shield
N/C
N/C
0/2
0/1
T1
0/0
/E
1
E
TH 0/1
C
onsole
Reset
RS
-232
Cross-over cable
Figure 12. Connecting a T1 PRI port to an NT device
1
2
3
4
5
6
7
8
*N/C = No connection*
NT
1
2
3
4
5
6
7
8
RJ-45, male
RX Ring
RX Tip
RX Shield
TX Ring
TX Tip
TX Shield
N/C
N/C
PRI port ................................................................................................................................................................51
49
SmartNode 4970 User Manual D • Port pin-outs
Introduction
This section provides pin-out information for the ports of the SmartNode.
Console port
Configuration settings: 9600 bps, 8 bits, no parity, 1 stop bit, no flow control
SmartNode 4970 User Manual E • SmartNode 4970 factory configuration
profile napt NAPT_WAN
profile dhcp-server DHCPS_LAN
network 192.168.1.0 255.255.255.0
include 1 192.168.1.10 192.168.1.99
lease 2 hours
default-router 1 192.168.1.1
domain-name-server 1 192.168.1.1
context ip router
interface WAN
ipaddress dhcp
use profile napt NAPT_WAN
tcp adjust-mss rx mtu
tcp adjust-mss tx mtu
port ethernet 0 0
medium auto
encapsulation ip
bind interface WAN router
no shutdown
Introduction54
Appendix F End user license agreement
Chapter contents
End User License Agreement.................................................................................................................................56
2. Title ............................................................................................................................................................56
3. Term ...........................................................................................................................................................56
4. Grant of License ..........................................................................................................................................56
7. Other licenses .............................................................................................................................................57
SmartNode 4970 User Manual F • End user license agreement
End User License Agreement
By opening this package, operating the Designated Equipment or downloading the Program(s) electronically,
the End User agrees to the following conditions:
1. Definitions
A)Effective Date shall mean the earliest date of purchase or download of a product containing the Patton
Electronics Company Program(s) or the Program(s) themselves.
B)Program(s) shall mean all software, software documentation, source code, object code, or executable code.
C)End User shall mean the person or organization which has valid title to the Designated Equipment.
D) Designated Equipment shall mean the hardware on which the Program(s) have been designed and pro-
vided to operate by Patton Electronics Company.
2. Title
Title to the Program(s), all copies of the Program(s), all patent rights, copyrights, trade secrets and proprietary
information in the Program(s), worldwide, remains with Patton Electronics Company or its licensors.
3. Term
The term of this Agreement is from the Effective Date until title of the Designated Equipment is transferred by
End User or unless the license is terminated earlier as defined in section “6. Termination” on page 57.
4. Grant of License
A)During the term of this Agreement, Patton Electronics Company grants a personal, non-transferable,
non-assignable and non-exclusive license to the End User to use the Program(s) only with the Designated
Equipment at a site owned or leased by the End User.
B)The End User may copy licensed Program(s) as necessary for backup purposes only for use with the Des-
ignated Equipment that was first purchased or used or its temporary or permanent replacement.
C)The End User is prohibited from disassembling; decompiling, reverse-engineering or otherwise attempt-
ing to discover or disclose the Program(s), source code, methods or concepts embodied in the Program(s)
or having the same done by another party.
D) Should End User transfer title of the Designated Equipment to a third party after entering into this
license agreement, End User is obligated to inform the third party in writing that a separate End User
License Agreement from Patton Electronics Company is required to operate the Designated Equipment.
5. Warranty
The Program(s) are provided as is without warranty of any kind. Patton Electronics Company and its licensors
disclaim all warranties, either express or implied, including but not limited to the implied warranties of merchantability, fitness for a particular purpose or non-infringement. In no event shall Patton Electronics Company or its licensors be liable for any damages whatsoever (including, without limitation, damages for loss of
business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the
use of or inability to use the Program(s), even if Patton Electronics Company has been advised of the possibility of such damages. Because some states do not allow the exclusion or limitation of liability for consequential
or incidental damages, the above limitation may not apply to you.
End User License Agreement56
SmartNode 4970 User Manual F • End user license agreement
If the Program(s) are acquired by or on behalf of a unit or agency of the United States Government, the Government agrees that such Program(s) are commercial computer software or computer software documentation and
that, absent a written agreement to the contrary, the Government’s rights with respect to such Program(s) are
limited by the terms of this Agreement, pursuant to Federal Acquisition Regulations 12.212(a) and/or DEARS
227.7202-1(a) and/or sub-paragraphs (a) through (d) of the “Commercial Computer Software - Restricted
Rights” clause at 48 C.F.R. 52.227-19 of the Federal Acquisition Regulations as applicable.
6. Termination
A)The End User may terminate this agreement by returning the Designated Equipment and destroying all
copies of the licensed Program(s).
B)Patton Electronics Company may terminate this Agreement should End User violate any of the provi-
sions of section “4. Grant of License” on page 56.
C)Upon termination for A or B above or the end of the Term, End User is required to destroy all copies of
the licensed Program(s)
7. Other licenses
The Program may be subject to licenses extended by third parties. Accordingly, Patton Electronics Company
licenses the Programs subject to the terms and conditions dictated by third parties. Third party software identified to the Programs includes:
• The LGPL (Lesser General Public License) open source license distributed to you pursuant to the LGPL
• MGCP and VPN capabilities will require the purchase of an additional license.
RedBoot (Red Hat Embedded Debug and Bootstrap) embedded system debug/bootstrap environment from
Red Hat distributed to you pursuant to the eCos license terms (http://ecos.sourceware.org/license-overview.html) and GNU General Public License (GPL) terms (http://www.gnu.org/copyleft/gpl.html).
Source code is available upon request.
End User License Agreement57
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.