Patton E1 2715 User Manual

USER MANUAL
MODEL 2715
NetLink-E1: E1/Fractional E1 NTU
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com
Part# 07M2715-A Doc# 086051UA Revised 12/10/98
An ISO-9001
Certified Company
PATTON MODEL 2715
TABLE OF CONTENTS
Section
Page
1.0 General Information ...............................................................2
1.1 Warranty Statement
1.2 Radio and TV Interference
1.3 CE and Telecommunication Approvals
1.4 Service Information
2.0 General Information........................................................5
2.1 Features
2.2 General Product Description
2.3.1 The 2715 as the Interface between the Telco and CPE
2.3.2 The 2715 as a High-Speed Short Range Modem
2.3 Supported Applications
3.0 Configuration .........................................................................7
3.1 DIP Switch Configuration
3.2 Software Configuration
3.2.1 Introduction to Main Menu
3.2.2 System Configuration
3.2.3 System Diagnostics
3.2.4 Unit Options
4.0 Installation ..........................................................................26
4.1 DTE Interface Connection
4.2 Network Interface Connection
4.3 Power Connection
4.3.1 Using The AC Power Supply (100-240VAC)
4.3.2 Supplying DC Power
4.3.3 Supplying Power via pin KK
5.0 Operation.............................................................................28
5.1 LED Descriptions
5.2 Loop (V.54 & Telco) Diagnostics
5.2.1 Operating Local Loopback (LL)
5.2.2 Operating Remote Digital Loopback (RDL)
5.3 Bit Error Rate (V.52) Diagnostics
Appendix A - Specifications ........................................................33
Appendix B - Cable Recommendations......................................34
Appendix C - Factory Replacement Parts and Accessories ......35
Appendix D - Interface Pin Assignments ....................................36
Appendix E - Power Supply Interface.........................................38
1
1.0 GENERAL INFORMATION
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant­ed for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to con­tact Patton Electronics Technical Services at (301) 975-1007.
1.1 WARRANTY STATEMENT
Patton Electronics warrants all Model 2715 components to be
free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.This warran­ty is limited to defects in workmanship or materials, and does not cover customer damage, abuse, or unauthorized modification. This product contains no serviceable parts; therefore the user shall not attempt to modify the unit in any way. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These dam­ages include, but are not limited to, the following: lost profits, lost sav­ings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically dis- claims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.In the event the user detects intermittent or continuous prod­uct malfunction due to nearby high power transmitting radio frequency equipment, the user is strongly advised to use only data cables with an external outer shield bonded to a metal or metalized connector.
2
1.4 SERVICE INFORMATION
All warranty and non-warranty repairs must be returned freight pre­paid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping contain­er.This number may be obtained from Patton Electronics Technical Support at:
tel: (301) 975-1007;
email: support@patton.com
www: http://www.patton.com.
NOTE: Packages received without an RMA number will not be
accepted.
Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Patton Model 2715. Technical Services hours: 8AM to 5PM EST,
Monday through Friday.
4
1.2 RADIO AND TV INTERFERENCE
The Model 2715 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and tele­vision reception. The Model 2715 has been tested and found to com­ply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interfer­ence will not occur in a particular installation. If the Model 2715 does cause interference to radio or television reception, which can be deter­mined by disconnecting the cables, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
1.3 CE AND TELECOMMUNICATION APPROVALS
The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support.
The Model 2715 is in compliance with the Telecommunication technical requirements CRT-12; 2.048 Mbps digital unstructured leased line (D2048U) attachment requirements for terminal equipment interface.
The Model 2715 also meets the Telecommunication technical requirements CTR-13; 2.048 Mbps digital structured leased lines (D2048S) attachment requirements for terminal equipment interface.
3
2.0 GENERAL INFORMATION
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant­ed for One Year parts and labor. If any questions arise during installa­tion or use of the unit, contact Patton Electronics Technical Services at (301) 975-1007.
2.1 FEATURES
• Terminates E1/FE1 Circuits over a 4-Wire RJ-48C interface
• Connects to standard CPE Serial Interfaces
• Common Framed nx64 rates up to 1.984 Mbps
• Unstructured Rate of 2.048 Mbps
• G.703 or G.704 Framing (with or without CRC-4, CAS multi­frame)
• Selectable AMI or HDB3 Line Coding
• Configuration via Control Port or Internal DIP Switches
• Seven Easy-to-Read LED Indicators Monitor Data & Diagnostics
• Internal, External or Receive Recover Clocking
• Also Operates as a High-Speed Point-to-Point Modem
• Compact Size Plugs Directly into a Router, Switch or other DTE
• Made in USA
2.2 GENERAL PRODUCT DESCRIPTION
The Patton Model 2715 Network Termination Unit (NTU) terminates both 2.048 Mbps G.703 E1 (clear channel) and fractional E1 G.704 (n x 64) 4-wire circuit. housed in our MicroPak enclosure measuring only 9 x 5.3 x 2 cm (3.55 x 2.1 x 0.78 in.) the Model 2715 plugs directly into the V.35 DTE interface of a router, switvh, FRAD, multiplexer or other networking device.
The Model 2715 supports all necessary G.703/G.704 diagnostics, DTE local/remote loops, and V.54 loop up/loop down. Diagnostics are initiat­ed via the Model 2715's control port, or through the DTE or line inter­faces. Easily readable LED indicators include TD, RD, Loss of Sync (LOS), Alarm, Error, Test and Power. Configuration of the Model 2715 is done through the control port or using DIP switches.
The Model 2715 presents a RJ45 120 ohm interface to the line and a V.35 interface to the customer's device using a Male M/34 connector. An M/34 to DB-60 adapter cable is available for convenient connection to Cisco routers. The Model 2715 is powered by an external Universal Input 100-240VAC adapter.
5
2.3 SUPPORTED APPLICATIONS
The Model 2715 provides an E1 network termination between E1 and Fractional E1 equipment and customer premises equipment (CPE) such as a router. The Model 2715 can also be used as a high-speed short haul modem for campus applications.
2.3.1 The 2715 as the Interface between the Telco and CPE
The Model 2715 provides the interface between an E1/Fractional
E1 multiplexer and a router or switch (See below).
2.3.2 The 2715 as a High-Speed Short Range Modem
The Model 2715 can also be installed into high-speed campus applications. In this application, a pair of Model 2715 units operate as short range modems (See below).
6
Model 2715
Model 2715
Model 2715
Switch SW1: Line Coding
Use Switch SW1 to control the Network Line Coding options. Set these options to be the same as the Line Coding given to you by your Service Provider. If you are using two Model 2715s together as short range modems, set both units to HDB3.
SW4 Line Framing & Coding
Off HDB3 On AMI
Line Coding Options:
High Density Bipolar 3 (HDB3): In HDB3 coding, the transmitter
deliberately inserts a bipolar violation when excessive zeros in the data stream are detected.The receiver recognizes these special violations and decodes them as zeros.This method enables the network to meet minimum pulse density requirements. Use HDB3 unless AMI is required in your application .
Alternate Mark Inversion (AMI): AMI coding does not inherently
account for ones density. To meet this requirement, the user should ensure that the data inherently meets pulse density requirements.
8
3.0 CONFIGURATION
The Model 2715 features configuration capability via hardware switches or a software control port. This section describes all possible hardware and software switch configurations of the Model 2715.
3.1 DIP SWITCH CONFIGURATION
The Model 2715 has eight internal DIP switches that allow configu­ration for a wide range of applications. The eight switches are accessed by opening the plastic case with a small screwdriver. Figure 1 (below) shows the location of the DIP switches on the bottom of the printed circuit board.
The Model 2715 DIP switches (Switches SW1 - SW8) can be con­figured as either “On” or “Off”. Figure 2 (below) shows the orientation of the DIP switches with respect to ON/OFF positions.
Default positions for Switches SW1-SW8 are shown in the table on the following page. Descriptions of each switch follow the table.
7
Figure 1. Model 2715 bottom view, showing location of DIP switches
OFF
ON
Figure 2. Close up of DIP switches showing ON/OFF positions.
The switch is shown in the Off position.
SWITCH SET SUMMARY TABLE
Position Function Factory Default Selected Option
SW1 Line Coding Off HDB3 SW2 CAS Multiframe Off Disabled SW3 CRC-4 Multiframe Off Disabled SW4 Clock Mode Off Network SW5 DTE Rate Off SW6 DTE Rate Off SW7 DTE Rate Off SW8 DTE Rate Off
2.048 Mbps Clear
Channel
}
DIP Switches
ON
OFF
Software Configuration Port
Switch SW2: CAS Multiframe
The Channel Associated Signaling (CAS) multiframe uses Timeslot 16 (TS16) to send multiframe (MF) alignment data. In CAS MF, a multi­frame is defined as 16 frames, where a frame consists of 32 64kb/s timeslots, numbered 0 to 31.TS16 of the first frame in the MF contains the CAS MF alignment word in the upper four bits.The alignment word is always 0000 (binary).The 2715 does not perform any signaling in TS16 other than to insert the MF alignment word, in order to maintain MF alignment.When CAS MF disabled, the unit transmits user data in TS16; therefore, up to 31 channels are available for user data.When it is enabled, TS16 is not available to the user. In this case, the user can use up to 30 channels for data. CAS MF can be used with CRC-4 MF or by itself.When enabled, both units must employ CAS MF; if one unit is set for CAS MF, and the other is not, the one using CAS MF will detect a loss of sync.
SW2
Option Off Disabled On Enabled
Switch SW3 & SW4: CRC-4 Multiframe/Clock mode
In framed mode, SW3 is used for CRC-4 MF. CRC-4 Multiframe uses Time Slot zero to carry CRC-4 information. It operates independently of CAS MF. When CRC-4 is enabled, the unit monitors the incoming data stream for CRC-4 errors.It transmits CRC-4 error counts to the trans­mitting unit. Excessive errors may cause loss of frame or loss of sync. If CRC-4 MF is used, both units must be set for set for CRC-4 MF. Otherwise, the one using CRC-4 MF will detect loss of sync.
In unframed mode, SW3 is used to along with SW4 to determine the clock mode.In unframed mode, the model 2715 can be set to network, internal or external clock mode.This is done by setting both SW3 and SW4 to the on position.
In framed mode SW4 is used alone to determine the 2715 transmitter timing.The 2715 can be set to Network or Internal clock.
The following charts represent both cases.
9
CLOCK MODES Network Clock Transmitter timing is derived from the received line
signal.
Internal Clock Transmitter clock is derived from an internal clock
source.
External Clock Transmitter timing is derived from the local DTE
device.Valid only in unframed mode.
Note: When using the 2715 as a high-speed shor t range modem, one unit of the link must be configured in either internal or external clock, and the other end must be configured for network clock mode.
Switches SW5, SW6, SW7, and SW8
Use Switches SW5, SW6, SW7, and SW8 to set the DTE data rate.
SW5
SW6 SW7 SW8 Speed Off Off Off Off Clear Channel (2.048Mbps) On Off Off Off 64kbps Off On Off Off 128kbps On On Off Off 192kbps Off Off On Off 256kbps On Off On Off 384kbps Off On On Off 512kbps On On On Off 640kbps Off Off Off On 768kbps On Off Off On 1024kbps Off On Off On 1280kbps On On Off On 1536kbps Off Off On On 1600kbps On Off On On 1920kbps Off On On On 1984kbps On On On On invalid
10
MULTIFRAME(G.704)
SW3 CRC-4 MF SW4 Clock Mode
On On Off Network Off Off On Internal
UNFRAMED (G.703)
SW3 SW4 Clock Mode
Off Off Network (Default) Off On Internal On On External On Off Network
NOTE: When the data rate is set to 2.048Mb/s, then the unit is forced into G.703 mode, and it transmits user data on all 32 times­lots.There is no framing information; therefore, the CAS MF (SW2)and CRC-4 (SW3) switches are ignored. In all other rate settings, the unit employs G.704 framing;TS0 is reserved for sig­naling.
3.2 SOFTWARE CONFIGURATION
The Model 2715 features a menu-driven command system that allows you to monitor/configure its operating parameters. Follow the instructions below to configure the Model 2715 using the software switches:
1) Plug the 9-pin male end of the cable to your terminal or com­puter’s DB-9 serial port and start up the terminal emulator software if necessary. Plug the miniature stereo plug into the rear of the unit. The small recessed jack on the right side of the unit is the control port jack.
NOTE: If your terminal uses a DB-25 connector, please use a DB-9 to DB-25 Adapter to connect to the cable (See Model 18PC-M).
2) Power up the terminal and set its RS-232 por t as follows:
9600 Baud 8 data bits, 1 stop bit, no parity Local echo off ANSI or VT-100 emulation Xon/Xoff software flow control enabled
3) Here is an example of a terminal emulator setup session.In normal font are the various parameter types.In bold type are the values that should be used for best results. Your terminal program’s setup screen may differ from this one:
11
4) When the unit is first turned on, the terminal screen may appear blank. Press the [Enter] key. If your serial connection is good, then the unit will immediately display a password prompt.The following message will appear in the middle of the screen:
5) Type in the password and press [Enter].The factory default password for the unit is:
patton
NOTE: The password is case sensitive. If the entr y is incor­rect, the password screen will clear and prompt you again for the correct password.The password you enter will not be shown. For security, asterisks will be displayed for each letter you type.The maximum length of the password, which can include any character the terminal can generate, is 16 charac­ters.
6) The Model 2715 will then display the Main Menu screen.
12
Baud rate: 9600 Parity: None Data Length: 8 Stop Bits: 1
Default terminal type: VT100
Local Echo: Off Add Line Feeds after CRs: Off Received Backspace Destructive: On Backspace key sends: BS XON/XOFF software flow control: On CTS/RTS hardware flow control: Off DSR/DTR hardware flow control: Off
Patton Electronics Menu Management
Enter Password: _
3.2.1 Introduction to Main Menu
After entering the password, you may access all of the system’s
functions and parameters.The Main Menu looks like this:
HELPFUL HINTS
1. To make a selection, key the highlighted letter that corre­sponds to a menu selection.
2. To execute the selection, type [Enter/CR].
3. To toggle between options on a highlighted selection, Press [space].
4. Select g Save Changes from Main Menu after making modi­fications to any Model 2715 parameter. Otherwise, changes will be lost when the Model 2715 is turned off.
13
The Main Menu options are briefly described below.
System Configuration options allow you to change various aspects of the Model 2715’s operation, e.g., framing, line cod­ing, and aggregate bandwidth.
System Diagnostics/Statistics options allow you to monitor the network performance, initiate V.54 loops, local loops, and send test patterns. Network performance parameters are updated once a second, giving you the ability to quickly deter­mine if there is a problem.
Unit Options allow you to customize the Model 2715 for your location.You can change the default header names to give each unit a unique name and password.Also, you can reset the unit to its default settings without the manual.It also has a Service Information screen in case you need technical assis­tance from Patton.
Save Changes Once you have configured the unit to your satisfaction, you can save the changes permanently by exe­cuting the Save Changes command.This will update the unit’s configuration and save all the parameters to permanent mem­ory.
Logoff For security, log off the control menu by executing the Logoff command. This will blank the screen until an [Enter] key is pressed.
14
d
a
b
c
d
e
3.2.2 System Configuration
The System Configuration menu looks like this:
The System Configuration options are described below:
Line Format: G.703
(default)
Options: G.703, G.704 G.703: G.703 is unframed, 2.048Mb/s. In this case, the DTE rate
is equal to the line rate at the network interface (NI).CAS MF and CRC-4 are disabled.
G.704: G.704 reserves TS0 for signaling and frame alignment.
Maximum data rate depends on whether CAS MF is enabled or not.
15
16
Line Coding: HDB3
(default)
Options: AMI, HDB3 HDB3: In this line coding, the transmitter substitutes a deliberate
bipolar violation when excessive zeros in the data stream are detected.The receiver recognizes these special violations and decodes them as zeros.This method enables the network to meet minimum pulse density requirements. Unless AMI is required in your application, HDB3 should be used whenever possible.
AMI: Alternate Mark Inversion defines a pulse as a "mark,” a
binary one, as opposed to a zero.In a E1 network connection, signals are transmitted as a sequence of ones and zeros. Ones are sent as pulses, and zeros are sent as spaces, i.e., no pulse. Every other pulse is inverted from the previous pulse in polarity, so that the signal can be effectively transmit­ted.This means, however, that a long sequence of zeros in the data stream will cause problems, since the NTU receiving the signal relies on the signal to recover the 2.048 Mb/s clock. If you must use AMI, you should ensure that the data terminal equipment connected to the unit provides a minimally accept­able pulse density. For this reason, there are advantages to using HDB3 instead.
a
b
Clocking: Network
(default)
Options: Network, Internal, External Network: This is the most commonly used setting when connect-
ing to a carrier’s network. In this mode, the unit recovers the clock from the received signal and uses it to transmit data.In this way the unit remains synchronized to a master clock. In campus applications, one of the units must be set to Internal clock, and the other end is set to Network clock.At all times, there must be only one clock source.Otherwise, clock slips and framing errors and bit errors may occur.
Internal: This is commonly used in campus applications, where
the unit is not connected to the public telephone network directly. In this mode, the unit uses the on-board oscillator as the transmit clock source.
External: This is a special mode that can only be used with the
Unframed format. In this mode, the unit requires a 2.048 Mhz clock signal from the DTE via the external clock pin on the DTE interface connector. Most applications will use Network or Internal clock modes.
CRC-4 Setting: Disabled
(default)
Options: Enabled, Disabled CRC-4 Multiframe: CRC-4 Multiframe uses TS0 to carry CRC-4
information. It operates independently of CAS MF. When CRC­4 is enabled, the unit monitors the incoming data stream for CRC-4 errors. It transmits CRC-4 error counts to the transmit­ting unit . Excessive errors may cause loss of frame or loss of sync. If CRC-4 MF is used, both units must be set for CRC-4 MF; otherwise, the one using CRC-4 MF will detect a loss of sync.
17
CAS MF Setting: Disabled
(default)
Options: Enabled, Disabled CAS MF: CAS multiframe uses Timeslot 16 (TS16) to send multi-
frame (MF) alignment data. In CAS MF, a MF is defined as 16 frames, where a frame consists of 32 64kb/s timeslots, num­bered 0 to 31.TS16 of the first frame in the MF contains the CAS MF alignment word in the upper four bits.The alignment word is always 0000 (binary).The 2715 does not perform any signaling in TS16 other than to insert the MF alignment word, in order to maintain MF alignment.When CAS MF disabled, the unit transmits user data in TS16;therefore, up to 31 chan­nels are available for user data. When it is enabled, TS16 is not available to the user. In this case, the user can use up to 30 channels for data. CAS MF can be used with CRC-4 MF or by itself.When enabled, both units must employ CAS MF; if one unit is set for CAS MF, and the other is not, the one using CAS MF will detect a loss of sync.
V.54 Loops: Enabled
(default)
Options: Enabled, Disabled
This is a special in-band loopback facility that sends a special pseudo­random pattern over the data stream.This is the only loopback that the unit can initiate.This is useful for campus applications when you need to put a remote unit in loopback.The unit responds to the V.54 loop­back command, and the whole process takes only a few seconds to complete. When V.54 Loopback is disabled, the unit will not be able to send or respond to V.54 loopback commands.The duration of the loop­back is limited by the loopback timeout setting. While V.54 is being activated, user data is overwritten.
Default Config Source: Switch (default) Options: EEPROM, Switch
The Model 2715 can be initialized via the configuration in the on-board permanent memory (EEPROM) or via the internal DIP switches (Switch). Once the unit is powered up, you may change the settings through the control port or the DIP switches. When you make changes through the control port, no changes will take place or be saved to per­manent memory until you Save Changes (Main Menu option "d" + [Enter]).When you make changes through the switches, all changes are made immediately.
18
d
f
i
j
g
3.2.3 System Diagnostics
The System Diagnostics/Statistics screen looks like this:
NOTE: This screen is updated once per second.
The System Diagnostics/Statistics options and functions are described below.
Local Loop Idle
(default)
The Local Loop is a bi-lateral loopback in which the data from the local DTE and the data from the remote unit are looped back to their respec­tive sources (See Section 5.3). Activate this loop to test the each of the DTE’s connection to the Model 2715.
The Local Loop test has four states:
Idle No user-controlled loopbacks are active. LL The Model 2715 is in local loopback mode. Off The Model 2715 is in remote loopback mode or sending a
pattern. Local loopback is disabled.
LocP The Model 2715 is in Local Loopback mode, and is send-
ing a test pattern.
20
If you do not have a terminal, you may force the unit to use the DIP switches as the default configuration source by turning off the unit, set­ting all the DIP switches to the ON position, then powering on the unit. This will cause the unit to enter a special mode.Then tur n off the unit and change the switch settings to the desired settings.When you turn the unit on again, the unit will be set up with the selected switch set­tings.
DS0 Channel Configuration Menu [ Bandwidth/# Channels = 2,048k/na]
(default)
The Channel Configuration Menu has a sub-menu that looks like this:
You may configure the Model 2715 to operate with any combination of active and inactive DS0 channels in this screen.When you execute the Save Changes command, the selected settings will be saved to perma­nent memory, and the system will be updated to operate with the new channel settings.
NOTE: In Unframed format, the Bandwidth Selected will display “2.048k,” and the Total Channels will display “na.” When using the DIP switches to set the bandwidth, the starting channel is always channel 1 or 0.
19
n
a
22
21
Remote Loop Idle
(default)
The Remote Digital Loopback (RDL) test checks the performance of both the local and remote Model 2715s, as well as the communica­tion link between them. Data from the local DTE is sent across the entire communication circuit and looped back to the local DTE.
The Model 2715 Initiating a RL can be in one of the following states:
Idle No user-controlled loopbacks are active.
TxPr The Model 2715 is sending the preparatory phase pattern
lasting for approximately 2 -5 seconds.
WtAk The Model 2715 is waiting for an acknowledgement from
the remote unit. If the remote unit does not respond, the WtAk message will remain on the screen.
RxAk The Model 2715 has received an acknowledgement from
the remote unit.
Tout The Model 2715 is waiting before entering the Remote
Loopback test mode.
TM The Model 2715 has successfully negotiated the Remote
Loopback test and is in control of the remote unit. You may send a test pattern at this point by pressing:
c <spacebar>
TxTr The Model 2715 is sending a Terminate Loopback mes-
sage to the remote unit. If the remote unit does not respond, the local unit will return to the Idle state.
Tx1s If the remote Model 2715 responds to the local Model
2715’s terminate loopback request, the local unit then sends an all ones pattern before returning to the Idle state
TxP The Model 2715 is sending a test pattern while in Test
Mode
IdlP The Model 2715 is sending a test pattern in place of data.
The Model 2715 is not in test mode.
The Model 2715 receiving a RL can be in one of the following states:
RxPr The Model 2715 is receiving a preparatory pattern. Sack The Model 2715, upon receiving a preparatory pattern,
sends an acknowledgement message.
RL The Model 2715 is in remote loopback mode. RxTr The Model 2715 is receiving a terminate loopback mes-
sage.
WE1s The Model 2715 is waiting for a sequence of all ones and
will time out if it does not receive it.
IdleP The Model 2715 is sending a QRSS, 511 or 2047 pat-
tern.
Off The Model 2715 is in local loopback. Test Pattern Idle
(default)
Options: Idle or Sending
To send a patter n, press the ‘c’ key and press <spacebar> to send the test pattern. The “OK” message indicates the received test pattern is error-free. The “BE” message indicates errors in the received pattern. You may also hear a beep (from your termainal) once a second as long as the unit detects a bit error in the pattern.
Idle Indicates that Model 2715 is not sending a pattern.
Sending
Indicates that Model 2715 is sending a pattern.
Error Insertion Off
(default)
Options: On, Off
You may inject intentional errors into the test pattern by turning Error Insertion ON. The Error (ERR) LED will blink once per second.
Selected Pattern Options: QRSS, 511, or 2047
b
d
c
e
23 24
Use this option to select the test pattern used to test the link.
NI STATUS
The Network interface (NI) status is shown in the middle of the Diagnostics/Statistics screen.The brackets are empty when the link is operating normally. Only one error message is provided
Receiver Carrier Loss [RCL] occurs when 255 consecutive zeros have been detected at the network interface. RCL clears when a pulse is detected.
Current DIP Switch Settings
The Switch settings are displayed here to facilitate troubleshooting your unit without opening up the unit first.
3.2.4 Unit Options
The Unit Options screen looks like this (factory default):
Header Line 1 & Header Line 2
Headers 1 and 2 are provided for easy identification of your unit after installation.You may want to give each unit a unique name via the header lines to help distinguish one unit from another.You can enter a header up to 40 letters long.Two lines provide 80 letters for your use. That’s a lot of flexibility!
Password
The Password facility provides security by allowing only those who know the correct password to configure the unit via the control port. You can still configure the unit via the DIP switches.The password can be up to 16 characters long, with no restriction on the combination of characters you can use, so be sure to remember the password. The password is case sensitive. If you lose your password, you will lose the ability to access the unit via the control port.
RCL
a
b
c
25 26
Loop Timeout
The Loop Timeout setting can be set to one of the following:
00:05 = five minutes
00:10 = ten minutes
00:15 = fifteen minutes
00:30 = thir ty minutes (default setting)
00:45 = forty-five minutes
01:00 = one hour
01:30 = 90 minutes
02:00 = two hours
03:00 = three hours
NEVER = forever—the unit will remain in loopback without user
intervention.
Set to Default Configuration
You may set the Model 2715 to its factory default configuration, except for the header lines and the password, by executing the Set to Default Configuration command.
Service Information
If you need to contact us for help, you can view the Service Information screen. Here is what it looks like:
4.0 INSTALLATION
The Model 2715 is equipped with DTE, network, and power interfaces. This section briefly describes connection to each.
4.1 DTE INTERFACE CONNECTION
The DTE interface is a V.35 DCE presented as an M/34 male connec­tor. This interface is designed to plug directly into a DTE interface (See Appendix D for V.35 interface pin assignments).
4.2 NETWORK INTERFACE CONNECTION
The Network Line Interface is an eight position keyed modular jack configured as a RJ-48C. This interface will need to be configured to match the line parameters (i.e. framing, line coding, etc.) supplied by the central office.
NOTE: If the Model 2715 is being used for private short range modem applications, the twisted pair cable connected to its port will need to be a cross-over cable. See Appendix D for Interface pin assignments.
d
f
g
Figure 3. Model 2715 twisted pair line interface.
1 RX Data (TIP) 2 RX Data (RING) 3 (no connection) 4 TX Data (TIP) 5 TX Data (RING) 6 (no connection) 7 (no connection) 8 (no connection)
1 2 3 4 5 6 7 8
27
28
4.3 POWER CONNECTION
The Model 2715 offers three ways to supply external power: AC
power, DC power and interface power.
4.3.1 Using the AC Power Supply (100-240VAC)
The Model 2715 uses a 5VDC, 2A universal input 100-240VAC, power supply (center pin is +5V). The universal input power supply is equipped with a male IEC-320 power entry connector. This power sup­ply connects to the Model 2715 by means of a barrel jack on the rear panel. There are a variety of international power cords available for the universal power supply. The Model 2715 powers up as soon as it is plugged into an AC outlet–there is no power switch.
4.3.2 Supplying DC Power
You may bypass the DC wall adapter and supply DC power directly to the NetLink E1™ power supply jack. DC power supplied must be +5VDC ±5%, 300mA minimum, center positive, and can be supplied via a barrel type plug with 2.1/5.5/10mm I.D./O.D./Shaft Length dimen­sions.
4.3.3 Supplying Power via pin KK
You may also supply DC power directly to pin KK of the V.35 inter­face. DC Power supplied to pin KK must be +5VDC ± 5%, 300mA min­imum.
NOTE: Model 2715 is factory configured to accept power from the enclosed DC wall adapter (See Sections 4.3.1 and 4.3.2 above). If you wish to supply power via pin KK on the interface, you must change the setting of the
power supply jumper
on the printed cir­cuit board See Appendix E. All power sources must be SELV (Circuit, Safety Extra Low Voltage) specified. (See CENELEC EN60950, Section 1.2.8.5)
5.0 OPERATION
Once the Model 2715 is installed and configured properly it is ready to place into operation. This section describes the function of the LED indicators, and the use of the loopback and pattern test modes.
5.1 LED DESCRIPTIONS
The Model 2715 is equipped with seven LED indicators that monitor the status of communication. Figure 4 (below) shows the location of the LEDs on the Model 2715 front panel.
TXD When the unit sends a one, the TXD LED is
turned on. When it sends a zero, the TXD LED is turned off. Moreover, the TXD LED is active only in active DS0 channels.In inac­tive channels, the TXD LED is off.
RXD When the unit receives a one, the RXD LED
is turned on. When it receives a zero, the RXD LED is turned off. Moreover, the RXD LED is active only in active DS0 channels. In inactive channels, the RXD LED is off.
Figure 4. Top of Model 2715, Showing LED Indicators
Model2715
29
30
LOS The Loss of Sync LED lights when the unit
loses synchronization with the incoming sig­nal.This may happen when there is a fram­ing mismatch or a loss of signal. In unframed mode, the LOS LED monitors the status of the transmit clock.
ALM The alarm LED indicates the presence of a
AIS or RAI, or Out of Frame condition.The ALM LED will blink on every half-second. Alarms may occur due to:
Loss of Synchronization
• Loss of Frame
• AIS (Blue Alarm)
• RAI (Yellow Alarm)
ERR The error LED indicates various error condi-
tions, including framing bit errors, excessive zeros, controlled slips, severe errors, or bit errors (when sending V.52 test patterns). When sending a test pattern, the LED will remain lit if the unit does not receive the identical pattern. When it receives the cor­rect pattern, the LED will turn off. If error insertion is on, the LED will blink once a second if everything is operating properly.
TST The test indicator LED blinks with a specific
pattern depending on the type of test mode. When the unit is in local analog loop, the LED will blink on briefly.When the unit is in remote loop, the TST LED will blink off briefly. When the unit is sending a test pat­tern or is putting the remote unit into V.54 loopback, the TST LED will stay on. These are the test modes:
• V.54 Loopback & V.52 Patterns
PWR The power indicator LED will remain lit while
the unit is powered. It turns off when the unit is not powered.
5.2 LOOP (V.54 & TELCO) DIAGNOSTICS
The Model 2715 offers three V.54 loop diagnostics. Use these diagnostics to test the NTU and any communication links. These tests can be activated via the software control port (See Section 3.2.3
System Diagnostics) or via signals on the serial port interface.
5.2.1 Operating Local Loopback (LL)
The Local Loopback (LL) test checks the operation of the local Model 2715, and is performed separately on each unit. Any data sent to the local Model 2715 in this test mode will be echoed (returned) back to the user device (i.e., characters typed on the keyboard of a ter­minal will appear on the terminal screen).
To perform a LL test, follow these steps:
1. Activate LL. This may be done in one of two ways: a. Enter Local Loop from the System
Diagnostics/Statistics menu and toggle the <Spacebar> until “LL” appears next to the Local Loop option.
b. Activate the “LL” signal on the DTE. If you are not sure
which lead is the “LL” signal, please refer to Appendix D.
2. Verify that the data terminal equipment is operating properly and can be used for a test.
3. Perform a V.52 BER (bit error rate) test as described in Section 5.3.3. If the BER test equipment indicates no faults, but the data terminal indicates a fault, follow the manufactur­er’s checkout procedures for the data terminal. Also, check the interface cable between the terminal and the Model 2715.
5.2.2 Operating Remote Digital Loopback (RDL)
The Remote Digital Loopback (RDL) test checks the performance of both the local and remote Model 2715, as well as the communica­tion link between them. Any characters sent to the remote Model 2715 in this test mode will be returned back to the originating device (i.e, characters typed on the keyboard of the local terminal will appear on the local terminal screen after having been passed to the remote Model 2715 and looped back).
a
a
31
32
To perform an RDL test, follow these steps:
1. Activate RDL. This may be done in two ways: a. Enter Remote Loop from the System
Diagnostics/Statistics menu and toggle the <Spacebar> until “TM” appears next to the Remote Loop option.;
b. Activate the “RL” signal on the DTE. If you are not sure
which lead is the “RL” signal, please refer to Appendix D.
2. Perform a bit error rate test (BERT) using the internal V.52 generator (as described in Section 5.3), or using a separate BER Tester. If the BER test indicates a fault, and the Local Line Loopback test was successful for both NetLink™s, you may have a problem with the twisted pair line connection.
5.3 BIT ERROR RATE (V.52) DIAGNOSTICS
The Model 2715 offers three V.52 Bit Error Rate (BER) test pat­terns. These test patter ns may be invoked along with the LAL and RDL tests to evaluate the unit(s) and the communication links.
When a 511, 2047, or QRSS test is invoked, the Model 2715 gen­erates a pseudo-random bit pattern of 511 bits, 2047 bits or 220bits, respectively, using a mathematical polynomial. The receiving NetLink­E1™ then decodes the received bits using the same polynomial. If the received bits match the agreed upon pseudo-random pattern, then the Model 2715(s) and the communication link(s) are functioning properly.
511 Initiates a built-in 511 bit pseudo-random
pattern generator and detector.
2047 Initiates a built-in 2047 bit pseudo-random
pattern generator and detector.
QRSS Initiates a built-in 2
20
bit pseudo-random
pattern generator and detector.
To perform a V.52 test, follow these steps:
1. Activate the local loopback or remote loopback diagnostic.
2. Activate the test pattern. This may be done in one of two ways:
a. Enter Selected Pattern from the System
Diagnostics/Statistics menu and toggle the <Spacebar> until the desired test pattern appears.
b. Enter Test Pattern and toggle the <Spacebar> to
send the selected pattern.
c. One of two result codes will appear to the right of the
Test Pattern listing: OK Indicates that the received test pattern is error-free. BE Indicates that there are errors in the test patter n (to
deliberately insert errors in the pattern, toggle
Error Insertion to ON).
b
b
e
d
c
c
33 34
APPENDIX A
PATTON MODEL 2715
SPECIFICATIONS
Network Data Rate: 2.048 Mbps Network Connector: RJ-48C Nominal Impedance: 120 ohm (75 ohm available when using
Patton Model 460 Balun)
DTE Interface: V.35 (DCE Orientation) on Male M/34 Line Coding: Selectable AMI or HDB3 Line Framing: G.703 (Unframed) or G.704/G.732
(Framed)
CAS Multiframing: Selectable On or Off CRC-4 Multiframing: Selectable On or Off Clocking: Internal, External, or Receive Recover DTE Data Rates: 64, 128, 192, 256, 384, 512, 640, 768,
1024, 1280, 1536, 1600, 1920, 1984, 2048 kbps
Time Slot Rate: 64 kbps DS0 Start Position: Arbitrary DS0 Mapping Position: Contiguous or Arbitrary Diagnostics: V.54 Loopback; V.52 Patterns: 511,
2047, and QRSS
Indicators: Power, Transmit Data, Receive Data,
Alarm, Loss of Sync, Test Mode, Error
Configuration: 8-Position DIP Switch and RS-232
Control Port
Power Supply: 100-240VAC, 50-60Hz, 0.4A Humidity: Up to 90% non-condensing Temperature: 0 to 70
o
C
Dimensions: 9.0 x 5.3 x 2.0 cm (3.5”L x 2.1”W x
0.78”H)
APPENDIX B
PATTON MODEL 2715
CABLE RECOMMENDATIONS
The Patton Model 2715 has been performance tested by Patton
technicians using twisted-pair cable with the following characteristics:
Wire Gaug
e Capacitance Resistance
19 AWG 83nf/mi or 15.72 pf/ft. .0163 Ohms/ft. 22 AWG 83nf/mi or 15.72 pf/ft. .0326 Ohms/ft. 24 AWG 83nf/mi or 15.72 pf/ft. .05165 Ohms/ft.
To gain optimum performance from the Model 2715 , please keep
the following guidelines in mind:
Always
use twisted pair wire—this is not an option.
• Use twisted pair wire with a capacitance of 20pf/ft or less.
• Avoid twisted pair wire thinner than 26 AWG (i.e. avoid AWG numbers higher than 26)
• Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance obtain­able. Functionality should not be affected.
• Many environmental factors can affect the maximum distance obtainable at a particular site. Use the above data rate/distance table as a
general guideline only.
Model 2703B Distance Table - Km (Miles)
Data Rate Wire Gauge
(kbps) .7mm (22) .5mm (24)
2048 1.2 (.76) 1.5 (.95)
35 36
APPENDIX C
PATTON MODEL 2715
FACTORY REPLACEMENT PARTS
AND ACCESSORIES
P
atton Model # Description
2715/CM/UI.....................V.35 to E1 Converter (V.35 M/34 Male,
UI)
10 - 09F ...........................6 Foot Control Port Cable, 25 mm to
DB9F
08055DCUI......................Universal Input Power Supply
10-CISCO-V35FT-1 .........Cable, V35 (M/34) Female To LFH60
Male
07M2715 .........................User Manual
APPENDIX D
PATTON MODEL 2715
INTERFACE PIN ASSIGNMENTS
RJ-48C E1 Network Interface
(RJ-48S Female Modular Jack)
Pin #
Signal 1 RX Data (TIP) 2 RX Data (RING) 4 TX Data (TIP) 5 TX Data (RING)
37
38
APPENDIX D
(continued)
PATTON MODEL 2715
INTERFACE PIN ASSIGNMENTS
M/34 Connector,Terminal Interface
Pin #
Signal A GND (Earth Ground/Shield) B SGND (Signal Ground) D CTS (DCE Source) E DSR (DCE Source, Always On) F CD (DCE Source) L LL (Local Loop, DTE Source)
M TM (Test Mode Indicator (DCE Source) N RL (Remote Loop, DTE Source)
P TD (Transmit Data +, DTE Source)
R RD (Receive Data +, DCE Source)
S TD/ (Transmit Data -, DTE Source) T RD/ (Receive Data -, DCE Source)
U SCTE (Transmit Clock+, DTE Source)
V RC (Receiver Clock +, DCE Source)
W SCTE/ (Transmit Clock-, DTE Source)
X RC/ (Receiver Clock -, DCE Source) Y TC (Transmitter Clock +, DCE Source)
AA TC/ (Transmitter Clock -, DCE Source) KK Aux. Power Input (+5VDC @ 300mA)
APPENDIX E
PATTON MODEL 2715
POWER SUPPLY INTERFACE
Via Main 5VDC power jack (J1) Center Pin: +5VDC @ 300 mA Outer Barrel: Ground
Jumper Position for Power via DC Power Jack (default):
Via Auxiliary Power Supplied to Pin KK on V.35 connector DC Power supplied to pin KK must be 5VDC ± 5%, 300mA minimum.
Jumper Position for Power via Pin KK:
NOTE: Model 2715 is factory configured to accept power from
the enclosed DC wall adapter (See Sections 4.3.1 and 4.3.2 above). If you wish to supply power via pin KK on the interface, you must change the setting of the
power supply jumper
on the printed circuit board. All power sources must be SELV (Circuit, Safety Extra Low Voltage) specified. (See CENELEC EN60950, Section 1.2.8.5)